Permit #2023100037
Permit Details
Status: COED
| Parcel Id: 07-11-31-7063-00500-0060 |
| GARAGE: 466 sqft |
| OPENED PORCH (WITH ROOF) : 170 sqft |
| CONDITIONED SPACE: 2306 sqft |
| Total Square Footage: 2942 sqft |
| Block: 00500 |
| Subdivision: 7063 - |
| Job Phone: 407-209-9705 |
| Location Address: 61 ZAUN TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/19/2023 |
| NOC: RECORDED |
| Applicant name: ROBERT W PEEBLES |
| Owner: FLORIDA SUN PARTNERS II LLC |
|
Address PO BOX 770279 ORLANDO, FL 32877 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤253,716.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
7345 GREEN BRIAR PKWY ORLANDO, FL 32819 |
CGC1511452 (Exp: 08/31/2024) | 407-209-9705 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CFC1430061 (Exp: 08/31/2026) | 407-404-4000 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 07/31/2024 | FINAL APPROVED | BWRIGHT |
| Note: 7/25/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/2/2024 9:29:29 AM *** has potable irr with PVB-no cross connection No power is pep tank | |||
| BLD - BUILDING FINAL | 07/29/2024 | FINAL APPROVED | BTAYLOR |
| Note: 7/25/2024 - PREVIOUS INSPECTION NOTES 7/25/24: 1). Front entry exterior outlet is not GFCI protected. E3902.3 - Outdoor 2). AHU requires a locking breaker. (no disconnect installed). NEC422.31 3). Condensate drain line (left side). Needs to be protected from damage. M1411.3 4). Guest bathroom (on Right side) vanity has no hot water. P2722.2 5). ODU needs to be anchored using the 4 Florida Approved anchors and cannot be anchored using the shipping hold downs. M1307.2/M1401.1 6). Off ridge vent is not secured along the front flange as required by the manufacturer & FBC R806.4 | |||
| BLD - BUILDING FINAL | 07/25/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/25/24: 1). Front entry exterior outlet is not GFCI protected. E3902.3 - Outdoor 2). AHU requires a locking breaker. (no disconnect installed). NEC422.31 3). Condensate drain line (left side). Needs to be protected from damage. M1411.3 4). Guest bathroom (on Right side) vanity has no hot water. P2722.2 5). ODU needs to be anchored using the 4 Florida Approved anchors and cannot be anchored using the shipping hold downs. M1307.2/M1401.1 6). Off ridge vent is not secured along the front flange as required by the manufacturer & FBC R806.4 | |||
| ROW - STORMWATER FINAL | 07/25/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/25/24 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/25/2024 | Disapproved - NO FEE | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/2/2024 9:29:29 AM *** has potable irr with PVB-no cross connection No power is pep tank | |||
| ROW - FINAL APRON (AFTER POUR) | 07/09/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/09/2024 | APPROVED | PFLANAGAN |
| Note: FINAL SURVEY DOES WHAT THE NOTE STATES BELOW ----------------------------------------------------------------------------- 6/24/24 MEET WITH JASON ON SITE FOR THE GRADING OF THIS LOT. WE HAVE COME TO THE CONCLUSION THAT WE ARE GOING TO DO A SPLIT DRAINAGE ON THIS LOT. THE HIGH POINT IS GOING TO BE AT THE BACK CORNERS OF THE HOUSE. THEN ALL WATER WILL FLOW TO THE BACK TO THE WETLANDS LIKE BOTH ADJACENT LOT TO THE RIGHT AND LEFT. TOLD HIM DONT WORRY ABOUT A REVISE SITE PLAN . CONTACT PARREN IF ANY QUESTIONS | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/09/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ---------------------------------------------------------------------------- 6/24/24 MEET WITH JASON ON SITE FOR THE GRADING OF THIS LOT WE HAVE COME TO THE CONCLUSION THAT WE ARE GOING TO DO A SPLIT DRAINAGE ON THIS LOT. THE HIGH POINT IS GOING TO BE AT THE BACK CORNERS OF THE HOUSE. THEN ALL WATER WILL FLOW TO THE BACK TO THE WETLANDS LIKE BOTH ADJACENT LOT TO THE RIGHT AND LEFT. TOLD HIM DONT WORRY ABOUT A REVISE SITE PLAN . CONTACT PARREN IF ANY QUESTIONS | |||
| U-CROSS CONNECTION | 07/02/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 7/2/2024 9:29:29 AM *** has potable irr with PVB-no cross connection | |||
| GRAVITY SEWER TEST | 07/02/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED TO ADDRESS POSTED FOR''911''. THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 07/02/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED TO ADDRESS POSTED FOR''911'' THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC - EARLY POWER | 07/02/2024 | APPROVED | RMARTIN |
| ROW- PROJECT STATUS | 06/24/2024 | APPROVED | PFLANAGAN |
| Note: MEET WITH JASON ON SITE FOR THE GRADING OF THIS LOT WE HAVE COME TO THE CONCLUSION THAT WE ARE GOING TO DO A SPLIT DRAINAGE ON THIS LOT. THE HIGH POINT IS GOING TO BE AT THE BACK CORNERS OF THE HOUSE. THEN ALL WATER WILL FLOW TO THE BACK TO THE WETLANDS LIKE BOTH ADJACENT LOT TO THE RIGHT AND LEFT. TOLD HIM DONT WORRY ABOUT A REVISE SITE PLAN . CONTACT PARREN IF ANY QUESTIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 06/07/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/7/24 PIPE ELEVATION IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| PEP TANK INSTALLATION REQUEST | 05/22/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 05/17/2024 | APPROVED | RSIMS |
| ELECTRIC-TUG | 05/16/2024 | APPROVED | RMARTIN |
| Note: 4/11/2024 - PREVIOUS INSPECTION NOTES 4/11/24: No change from previous inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES 4/5/24: * Electrical ground needs to be in a conduit from ground to panel. NEC 250-92 | |||
| LATH/BRICK/ WATER BARRIER | 05/08/2024 | APPROVED | BTAYLOR |
| ALL ROUGH | 05/08/2024 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 04/18/2024 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2460 4/15/2024 - PREVIOUS INSPECTION NOTES 4/15/24: Previously listed Item 1 remains unresolved and item 2 the pile of trash & debris needs to be put into the dumpster. 4/17/24: Please make sure there is a set of full plans in the permit box for Inspector Only as required. FBC 107.3.1 Thank you --- No plans in the box. Sub Contractors had them in the house and all dis-organized. 4/11/2024 - PREVIOUS INSPECTION NOTES 4/11/24: Inspection Complete / Previous deficiency remains unresolved. 1). Truss T25 _ web 5-10 is not connected as required on MiTek. Highlighted on MiTek 2). Need dumpster emptied & piles of trash/debris cleaned up to make site safe for inspections, etc. 3). Silt fence needs repair. Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. Inspector Notes from Inspection 2340 4/1/24: Previous item 2 still needs to be resolved (1/2" MAX thickness) Approved as noted to keep project moving. Must be resolved prior to next Inspection. 3/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/17/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/15/2024 - PREVIOUS INSPECTION NOTES 4/15/24: Previously listed Item 1 remains unresolved and item 2 the pile of trash & debris needs to be put into the dumpster. 4/17/24: Please make sure there is a set of full plans in the permit box for Inspector Only as required. FBC 107.3.1 Thank you --- No plans in the box. Sub Contractors had them in the house and all dis-organized. 4/11/2024 - PREVIOUS INSPECTION NOTES 4/11/24: Inspection Complete / Previous deficiency remains unresolved. 1). Truss T25 _ web 5-10 is not connected as required on MiTek. Highlighted on MiTek 2). Need dumpster emptied & piles of trash/debris cleaned up to make site safe for inspections, etc. 3). Silt fence needs repair. Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. Inspector Notes from Inspection 2340 4/1/24: Previous item 2 still needs to be resolved (1/2" MAX thickness) Approved as noted to keep project moving. Must be resolved prior to next Inspection. 3/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/15/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/15/24: Previously listed Item 1 remains unresolved and item 2 the pile of trash & debris needs to be put into the dumpster. 4/11/2024 - PREVIOUS INSPECTION NOTES 4/11/24: Inspection Complete / Previous deficiency remains unresolved. 1). Truss T25 _ web 5-10 is not connected as required on MiTek. Highlighted on MiTek 2). Need dumpster emptied & piles of trash/debris cleaned up to make site safe for inspections, etc. 3). Silt fence needs repair. Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. Inspector Notes from Inspection 2340 4/1/24: Previous item 2 still needs to be resolved (1/2" MAX thickness) Approved as noted to keep project moving. Must be resolved prior to next Inspection. 3/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| WALL SHEATHING | 04/15/2024 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/11/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/11/24: Inspection Complete / Previous deficiency remains unresolved. 1). Truss T25 _ web 5-10 is not connected as required on MiTek. Highlighted on MiTek 2). Need dumpster emptied & piles of trash/debris cleaned up to make site safe for inspections, etc. 3). Silt fence needs repair. Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. Inspector Notes from Inspection 2340 4/1/24: Previous item 2 still needs to be resolved (1/2" MAX thickness) Approved as noted to keep project moving. Must be resolved prior to next Inspection. 3/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| ELECTRIC-TUG | 04/11/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/11/24: No change from previous inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES 4/5/24: * Electrical ground needs to be in a conduit from ground to panel. NEC 250-92 | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/08/2024 | APPROVED | TBAKER |
| ELECTRIC-TUG | 04/05/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/5/24: * Electrical ground needs to be in a conduit from ground to panel. NEC 250-92 | |||
| TIE BEAM / LINTEL | 04/01/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/1/24: Previous item 2 still needs to be resolved (1/2" MAX thickness) Approved as noted to keep project moving. Must be resolved prior to next Inspection. 3/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| TIE BEAM / LINTEL | 03/28/2024 | Disapproved - NO FEE | RSIMS |
| Note: 2/28/24: 1). Down rod not tied to dowel at right front corner. Highlighted on plan. 2). Back right window sill mortar bed too thick 606.3.1. Highlighted on plan. | |||
| MONOLITHIC SLAB | 03/19/2024 | APPROVED | RSIMS |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/13/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO ADDRESS POSTED FOR''911'' | |||
| WATER METER INSTALLATION REQUEST | 02/28/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 07/24/2024 | 07/24/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM No zoning review for blower door test. | |||
| MECH | COMPLETE | 04/29/2024 | 05/02/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/12/2024 | 04/16/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition | |||
| ENGIN1 | COMPLETE | 04/08/2024 | 04/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/08/2024 | 04/08/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/26/2023 | 10/26/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/26/2023 | 11/07/2023 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/26/2023 | 10/27/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/09/2023 | 10/09/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/03/2023 | 11/15/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/02/2023 | 10/05/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| CUSVC | COMPLETE | 10/02/2023 | 10/05/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/02/2023 | 10/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/02/2023 | 10/03/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/02/2023 | 10/04/2023 |
| LOCATE | COMPLETE | 10/02/2023 | 10/04/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/02/2023 | 10/04/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| SW1 | HOLD | 10/02/2023 | 10/03/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE AT A MINIMUM OF 4" OF FALL IN THE BACK OFF THE HOUSE FOR THE FIRST 10' | |||
| ZON | HOLD | 10/02/2023 | 10/03/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM This lot has a typical 5ft easement. Please remove the 20ft mbsl/easement in the rear from site plan and survey | |||
| BADMIN | COMPLETE | 10/02/2023 | 10/09/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 07/29/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 07/29/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/29/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/29/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/29/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/29/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/19/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/19/2023 |
| SEWER CREDIT | (¤850.00) | 12/19/2023 |
| SEWER INSPECTION | ¤25.00 | 12/19/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 12/19/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 12/19/2023 |
| SITE PLAN 30 | ¤30.00 | 12/19/2023 |
| CONNECTION FEES | ¤1,166.26 | 12/19/2023 |
| WATER- TURN ON | ¤25.00 | 12/19/2023 |
| ADJUSTMENT 50% | (¤512.73) | 12/19/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/19/2023 |
| INSPECTION - RESIDENTIAL | ¤775.50 | 12/19/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤219.96 | 12/19/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 12/19/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 12/19/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 12/19/2023 |
| IMPACT FEE FIRE | ¤428.09 | 12/19/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/19/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/19/2023 |
| IMPACT FEE PARKS | ¤1,800.99 | 12/19/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 12/19/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 12/19/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/19/2023 |
| SURCHARGE FS 533.721 | ¤5.13 | 12/19/2023 |
| SURCHARGE - FS 468.631 | ¤7.69 | 12/19/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/19/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/19/2023 |
| SW ENG PRE APRON | ¤30.00 | 12/19/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,837.09 |