I want to search for...
Permit #2023100219
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00090-0170 |
| CONDITIONED SPACE: 2712 sqft |
| GARAGE: 764 sqft |
| OPENED PORCH (WITH ROOF) : 91 sqft |
| PATIO/DECK (NO ROOF) : 442 sqft |
| Total Square Footage: 4009 sqft |
| Block: 00090 |
| Subdivision: - |
| Job Phone: 407-808-8155 |
| Location Address: 110 NEW LEATHERWOOD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/24/2023 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/18/2024 | FINAL APPROVED | BTAYLOR |
| Note: 9/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/20/2024 8:22:05 AM *** Cancelled per Mason, (not ready) | |||
| BLD - BUILDING FINAL | 09/20/2024 | CANCELLED BY APPLICANT | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 9/20/2024 8:22:05 AM *** Cancelled per Mason, (not ready) | |||
| U -UTILITY RESIDENTIAL FINAL | 08/26/2024 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 08/26/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/26/2024 10:08:31 AM *** relaim irr-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 08/23/2024 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9465 8/23/24 UPON WALKING PROPERTY DETERMINED THAT WHILE IT IS A BIT STEEP IN THE REAR OF THE PROPERTY THE SURVEY ELEVATION SHOW THAT FALL AND FLOW NUMBERS INDICATED POSITIVE DRAINAGE. APPROVING AS NOTED. Inspector Notes from Inspection 9463 8/23/24 FINAL SURVEY NOW REFLECTS REVISED SITE PLAN. APPROVING AS NOTED. _____________________________________________________________________________________________________________________________ 8/15/2024 - PREVIOUS INSPECTION NOTES | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/23/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/23/24 FINAL SURVEY NOW REFLECTS REVISED SITE PLAN. APPROVING AS NOTED. _____________________________________________________________________________________________________________________________ 8/15/2024 - PREVIOUS INSPECTION NOTES | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/23/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/23/24 UPON WALKING PROPERTY DETERMINED THAT WHILE IT IS A BIT STEEP IN THE REAR OF THE PROPERTY THE SURVEY ELEVATION SHOW THAT FALL AND FLOW NUMBERS INDICATED POSITIVE DRAINAGE. APPROVING AS NOTED. Inspector Notes from Inspection 9463 8/23/24 FINAL SURVEY NOW REFLECTS REVISED SITE PLAN. APPROVING AS NOTED. _____________________________________________________________________________________________________________________________ 8/15/2024 - PREVIOUS INSPECTION NOTES | |||
| ROW - STORMWATER FINAL | 08/23/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/23/24 UPON WALKING PROPERTY DETERMINED THAT WHILE IT IS A BIT STEEP IN THE REAR OF THE PROPERTY THE SURVEY ELEVATIONS SHOW THAT FALL AND FLOW NUMBERS INDICATE POSITIVE DRAINAGE. APPROVING AS NOTED At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. . | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/15/2024 | CANCELLED BY APPLICANT | FSLADISH |
| ROW- PRE-APRON (PRE-POUR) | 06/21/2024 | APPROVED | PFLANAGAN |
| Note: READY FOR PAVERS ---------------------------------------------------------------------- 6/12/2024 - PREVIOUS INSPECTION NOTES 06/12/24 TPOLACEK*** AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PAVER RESTRAINTS | 06/12/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 06/12/2024 | PARTIALLY APPROVED | TPOLACEK |
| Note: 06/12/24 TPOLACEK*** AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| TIE BEAM / LINTEL | 06/11/2024 | APPROVED | BTAYLOR |
| ELECTRIC - EARLY POWER | 05/29/2024 | APPROVED - AS NOTED | BTAYLOR |
| Note: 5-29-24 1. Emailed FPL at 8:56. | |||
| LATH/BRICK/ WATER BARRIER | 02/28/2024 | APPROVED | BTAYLOR |
| INSULATION | 02/23/2024 | APPROVED | BTAYLOR |
| GRAVITY SEWER TEST | 02/21/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 REMOVE ALL COQUINA FROM INTERIOR OF SLAB BEFORE BACKFILLING ONTO WASTE AND WATER LINES Inspector Notes from Inspection 2060 REMOVE ALL COQUINA FROM INTERIOR OF SLAB BEFORE BACKFILLING ONTO WASTE AND WATER LINES THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 02/21/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 REMOVE ALL COQUINA FROM INTERIOR OF SLAB BEFORE BACKFILLING ONTO WASTE AND WATER LINES Inspector Notes from Inspection 2060 REMOVE ALL COQUINA FROM INTERIOR OF SLAB BEFORE BACKFILLING ONTO WASTE AND WATER LINES THIS WAS A VIRTUAL INSPECTION | |||
| ALL ROUGH | 02/20/2024 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 01/23/2024 | APPROVED | BTAYLOR |
| WALL SHEATHING | 01/05/2024 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 01-03-2024 1. Garage trusses straps not fastened completely. Check all. 2. A3 DetailA Copula- framing and straps not visible . Please remove a section for inspection. 3. S2 structural fascia screws not visible. 4. S4 Gable end detail not per plan. 5. Truss JO5KA hip at back left has been cut. Please provide engineering and submit to the building department. 6. Address not posted. Check at next inspection. Superintendent on site and will address shiners ASAP. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/03/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: 01-03-2024 1. Garage trusses straps not fastened completely. Check all. 2. A3 DetailA Copula- framing and straps not visible . Please remove a section for inspection. 3. S2 structural fascia screws not visible. 4. S4 Gable end detail not per plan. 5. Truss JO5KA hip at back left has been cut. Please provide engineering and submit to the building department. 6. Address not posted. Check at next inspection. Superintendent on site and will address shiners ASAP. | |||
| ELECTRIC-TUG | 12/21/2023 | APPROVED | RMARTIN |
| TIE BEAM / LINTEL | 12/20/2023 | APPROVED | BTAYLOR |
| FOUND SURVEY APPROVED (OFFICE) | 12/11/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 12/07/2023 | APPROVED | BTAYLOR |
| Note: 12/4/2023 - PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 12/04/2023 | CANCELLED BY APPLICANT | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/01/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: REMOVE ALL COQUINA FROM INTERIOR OF SLAB BEFORE BACKFILLING ONTO WASTE AND WATER LINES | |||
| FOOTER | 11/06/2023 | APPROVED | RSIMS |
| WATER METER INSTALLATION REQUEST | 10/27/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 08/19/2024 | 08/20/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/19/2024 | 08/20/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/19/2024 | 08/19/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/05/2024 | 01/05/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator | |||
| ENGIN1 | COMPLETE | 12/11/2023 | 12/11/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/11/2023 | 12/11/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/24/2023 | 10/24/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/24/2023 | 10/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/05/2023 | 10/13/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 10/05/2023 | 10/09/2023 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | COMPLETE | 10/05/2023 | 10/09/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/05/2023 | 10/05/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/05/2023 | 10/09/2023 |
| LOCATE | COMPLETE | 10/05/2023 | 10/06/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/05/2023 | 10/09/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition | |||
| SW1 | COMPLETE | 10/05/2023 | 10/05/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/05/2023 | 10/06/2023 |
| Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Provide banding for the window facing the public ROW (right side). | |||
| BADMIN | COMPLETE | 10/05/2023 | 10/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤505.39 | 10/24/2023 |
| WATER-METER | ¤419.86 | 10/24/2023 |
| ADJUSTMENT 50% | (¤639.81) | 10/24/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/24/2023 |
| INSPECTION - RESIDENTIAL | ¤973.50 | 10/24/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤276.12 | 10/24/2023 |
| CONNECTION FEES | ¤25.00 | 10/24/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 10/24/2023 |
| IMPACT FEE FIRE | ¤428.09 | 10/24/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 10/24/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 10/24/2023 |
| IMPACT FEE PARKS | ¤1,800.99 | 10/24/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 10/24/2023 |
| IMPACT FEE TRANSPORTATION | ¤3,311.00 | 10/24/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/24/2023 |
| SURCHARGE FS 533.721 | ¤6.40 | 10/24/2023 |
| SURCHARGE - FS 468.631 | ¤9.60 | 10/24/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/24/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/24/2023 |
| SW ENG PRE APRON | ¤30.00 | 10/24/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/24/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/24/2023 |
| SEWER INSPECTION | ¤25.00 | 10/24/2023 |
| SEWER CAPITAL FACILITY | ¤1,682.11 | 10/24/2023 |
| WATER CAPITAL FACILITY FEE | ¤1,398.48 | 10/24/2023 |
| SITE PLAN 30 | ¤30.00 | 10/24/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,654.73 |