Permit #2023100572
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00420-0200 |
| CONDITIONED SPACE: 2000 sqft |
| GARAGE: 476 sqft |
| OPENED PORCH (WITH ROOF) : 197 sqft |
| OPENED PORCH (WITH ROOF) : 144 sqft |
| Total Square Footage: 2817 sqft |
| Block: 00420 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 912-258-2201 |
| Location Address: 32 PILLORY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/28/2024 |
| NOC: RECORDED |
| Applicant name: JAMES FUCETOLA III |
| Owner: PALM COAST COMMUNITIES LLC |
|
Address PO BOX 22547 ST SIMONS ISLAND, GA 31522 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤215,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
PALM COAST COMMUNITIES LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 22547 PALM COAST, FL 32164 |
CBC1262878 (Exp: 08/31/2026) | 321-501-4617 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/25/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/25/2024 10:16:47 AM *** 10/25/24: 1). Counter outlet to the left of the Range (two away on left side) is not secured at the bottom as required. (NEC-406.6) | |||
| BLD - BUILDING FINAL | 10/25/2024 | FINAL APPROVED | RSIMS |
| Note: 10/25/24: Repair confirmed via FaceTime video/audio phone app at @ 10:37. 10/25/2024 - PREVIOUS INSPECTION NOTES 10/25/24: 1). Counter outlet to the left of the Range (two away on left side) is not secured at the bottom as required. (NEC-406.6) | |||
| U -UTILITY RESIDENTIAL FINAL | 10/25/2024 | FINAL APPROVED | DHANEY |
| Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 10/24/2024 11:33:09 AM *** has potable irr with DBL CHECK-no cross connection | |||
| U-CROSS CONNECTION | 10/24/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/24/2024 11:33:09 AM *** has potable irr with DBL CHECK-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 10/24/2024 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/24/2024 | APPROVED | TPOLACEK |
| Note: 10/22/2024 - PREVIOUS INSPECTION NOTES 10/22/24 YOU ARE REQUIRED TO HAVE 10' OFFSET ELEVATION SHOTS ON ALL ADJOINING PROPERTIES. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. YOU ARE SHOWING 24.00 FOR THREE CONSECUTIVE SHOTS ON THE LEFT SIDE PROPERTY LINE. Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/24/2024 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 10/24/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/22/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 10/22/24 YOU ARE REQUIRED TO HAVE 10' OFFSET ELEVATION SHOTS ON ALL ADJOINING PROPERTIES. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. YOU ARE SHOWING 24.00 FOR THREE CONSECUTIVE SHOTS ON THE LEFT SIDE PROPERTY LINE. Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." | |||
| ROW- PRE-APRON (PRE-POUR) | 08/15/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ELECTRIC - EARLY POWER | 08/08/2024 | APPROVED | LMILLER |
| GRAVITY SEWER TEST | 07/24/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY. NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION | |||
| SEWER TIE IN | 07/24/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY. NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 07/15/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 06/25/2024 | APPROVED | KSANDOE |
| LATH/BRICK/ WATER BARRIER | 06/20/2024 | APPROVED | KSANDOE |
| ALL ROUGH | 06/18/2024 | APPROVED | KSANDOE |
| Note: 6/14/2024 - PREVIOUS INSPECTION NOTES Electrician still working. Not ready for inspection | |||
| ALL ROUGH | 06/14/2024 | Disapproved - NO FEE | KSANDOE |
| Note: Electrician still working. Not ready for inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/29/2024 | APPROVED | RSIMS |
| Note: 5/24/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/24/2024 2:36:18 PM *** Portolet has not been moved. Silt fence has not been repaired. Address must be posted clearly on contrasting background, minimum 4" tall and visible from street. R319.1 Inspector Notes from Inspection 2467 5/15/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. NOTE: Inspection 2460 still needs to be completed as only the Roof Sheathing was approved during the initial RS/B/T/DC Inspection. 1) Please repair your silt fence on the right side and keep it maintained throughout the build as required. FBC 3307.1 2). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. Inspector Notes from Inspection 2460 05-07-2024 THIS IS FOR ROOF SHEATHING ONLY. APPROVED. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/24/2024 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: *** NOTES ADDED BY KSANDOE 5/24/2024 2:36:18 PM *** Portolet has not been moved. Silt fence has not been repaired. Address must be posted clearly on contrasting background, minimum 4" tall and visible from street. R319.1 Inspector Notes from Inspection 2467 5/15/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. NOTE: Inspection 2460 still needs to be completed as only the Roof Sheathing was approved during the initial RS/B/T/DC Inspection. 1) Please repair your silt fence on the right side and keep it maintained throughout the build as required. FBC 3307.1 2). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. Inspector Notes from Inspection 2460 05-07-2024 THIS IS FOR ROOF SHEATHING ONLY. APPROVED. | |||
| ROOF VALLEY & METAL | 05/15/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 5/15/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. NOTE: Inspection 2460 still needs to be completed as only the Roof Sheathing was approved during the initial RS/B/T/DC Inspection. 1) Please repair your silt fence on the right side and keep it maintained throughout the build as required. FBC 3307.1 2). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. Inspector Notes from Inspection 2460 05-07-2024 THIS IS FOR ROOF SHEATHING ONLY. APPROVED. | |||
| WALL SHEATHING | 05/07/2024 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/07/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: 05-07-2024 THIS IS FOR ROOF SHEATHING ONLY. APPROVED. | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/06/2024 | APPROVED | TDOAK |
| TIE BEAM / LINTEL | 04/25/2024 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2250 4/16/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in complete compliance. | |||
| MONOLITHIC SLAB | 04/16/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/16/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in complete compliance. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/11/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: 3307.1 PROTECTION OF PROPERTY. NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 03/26/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 05/06/2024 | 05/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/06/2024 | 05/06/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/02/2023 | 11/02/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/02/2023 | 11/02/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/02/2023 | 11/15/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/02/2023 | 11/02/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/13/2023 | 10/14/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 10/13/2023 | 10/17/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 10/13/2023 | 10/13/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 4. NEC 2017 210.52 | |||
| ENGIN1 | COMPLETE | 10/13/2023 | 10/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/13/2023 | 10/16/2023 |
| LOCATE | COMPLETE | 10/13/2023 | 10/17/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/13/2023 | 10/16/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/13/2023 | 10/24/2023 |
| Note: Held By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM NEED TO HAVE PROPOSED ELEVETIONS AT ALL CORNERS OF THE PROPOSED STRUCTURE. THER ARE NONE ON THE FRONT TWO CORNERS. | |||
| ZON | HOLD | 10/13/2023 | 10/13/2023 |
| Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM ON LANDSCAPE PLAN: 1. ALL trees must be labeled. 2. The plantings around the A/C must be 7 gal size. | |||
| BADMIN | COMPLETE | 10/13/2023 | 10/16/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/13/2023 | 12/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 10/25/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/25/2024 |
| CONNECTION FEES | ¤1,166.26 | 02/28/2024 |
| WATER- TURN ON | ¤25.00 | 02/28/2024 |
| ADJUSTMENT 50% | (¤465.08) | 02/28/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/28/2024 |
| INSPECTION - RESIDENTIAL | ¤701.25 | 02/28/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤198.90 | 02/28/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 02/28/2024 |
| IMPACT FEE FIRE | ¤428.09 | 02/28/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/28/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/28/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 02/28/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 02/28/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 02/28/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/28/2024 |
| SURCHARGE FS 533.721 | ¤4.65 | 02/28/2024 |
| SURCHARGE - FS 468.631 | ¤6.98 | 02/28/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/28/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/28/2024 |
| SW ENG PRE APRON | ¤30.00 | 02/28/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/28/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/28/2024 |
| SEWER CREDIT | (¤1,147.00) | 02/28/2024 |
| SEWER INSPECTION | ¤25.00 | 02/28/2024 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 02/28/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 02/28/2024 |
| SITE PLAN 30 | ¤30.00 | 02/28/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,318.74 |