I want to search for...

Permit #2023100609

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00960-0060
CONDITIONED SPACE: 2387 sqft
OPENED PORCH (WITH ROOF) : 371 sqft
OPENED PORCH (WITH ROOF) : 89 sqft
GARAGE: 707 sqft
Total Square Footage: 3554 sqft
Block: 00960
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 407-580-2657
Location Address: 3 EVANSTON PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/17/2023
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: VICARIO PAUL & YOLANDA Y H&W

Address

809 RENAISSANCE DR

WILLIAMSTOWN, NJ 08094

Lot: 0060
Contracted Stated Job Value: ¤790,000.00
Job Description: Single Family Home
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
KERRY DWAIN AYLESWORTH II
Status Location Address Mailing Address State License Number Phone
ACTIVE

2820 LEWIS SPEEDWAY

ST AUGUSTINE, FL 32084

STE B

ST AUGUSTINE, FL 32084

CAC1820713 (Exp: 08/31/2026) 904-342-5709
ERIC FRANCO
Status Location Address Mailing Address State License Number Phone
INACTIVE

840 DELTONA BLVD

DELTONA, FL 32725

STE F2

DELTONA, FL 32725

CCC1327280 (Exp: 08/31/2026) 386-575-4007
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 01/17/2025 APPROVED - AS NOTED LFITZGERALD
Note: potable irr with PVB -no cross connection 1/16/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 1/16/2025 10:12:07 AM *** has potable irrigation with no check valve installed
U-CROSS CONNECTION 01/16/2025 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/16/2025 10:12:07 AM *** has potable irrigation with no check valve installed
BLD - BUILDING FINAL 01/16/2025 APPROVED CVANSTRAHLEN
Note:
BLD - BUILDING FINAL 01/14/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Meter main door does not close properly and dead front appears not to be installed properly (gap above main) 2. Soffit lighting missing on front of home 3. Porta jon must be removed before final 4. Dishwasher/disposal required to be GFCI protected 5. Breaker locks required for built in kitchen appliances 6. ODU disconnect requires 3' of working space (behind unit) 7. Electrical panel needs proper labeling 8. 2'' PVC riser required to be secured 9. Romex exposed at meter main 10. Garage door bucks missing anchors per manufacter specs
ROW - FINAL APRON (AFTER POUR) 01/09/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 01/09/2025 APPROVED - AS NOTED PFLANAGAN
Note: TREE HAS BEEN MOVED OUT OF DRAINAGE PATTERN GRADE IS OK AT THIS TIME WHERE IT WAS PASSING AS NOTED. -------------------------------------------------------------------- 1/8/25 UPON WALKING PROPERTY DETERMINED THAT IN THE REAR LEFT CORNER YOU WILL NEED TO REMOVE/RELOCATE TREE AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE AD WILL HOLD/OBSTRUCT DRAINAGE FROM MOVING FROM THE REAR TO THE FRONT SWALE. Trees or clusters of vegetation that would restrict flow Sec 300.03 C-G. Sec 300.03 C-G. Show any trees or clusters of vegetation that would restrict flow along the sidelines to the front swale, drainage ditch, or other drainage conveyance. Flatwork, i.e., slabs, walkways, hardscaping Sec 300.03 C1F "Flatwork, i.e., slabs, walkways, hardscaping, patios, decking, or AC pads, are not allowed in any utility easements/ drainage conveyance. Additionally, decorative objects, columns, light poles, mulch, stones, plantings, or landscaping of any kind are not allowed in the Right of Way. I am approving this inspection as a courtesy and as noted that you will need to remove/relocate tree in rear left property corner before Row final passage. 12/13/2024 - PREVIOUS INSPECTION NOTES 12/13/24 You must first submit and pass a final survey before a field survey inspection can be completed. I am not going to fee you today as a courtesy. Please submit your final survey and schedule a final survey inspection.
U -UTILITY RESIDENTIAL FINAL 01/09/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/08/2025 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 01/08/2025 APPROVED - AS NOTED FSLADISH
Note: 1/8/25 UPON WALKING PROPERTY DETERMINED THAT IN THE REAR LEFT CORNER YOU WILL NEED TO REMOVE/RELOCATE TREE AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE AD WILL HOLD/OBSTRUCT DRAINAGE FROM MOVING FROM THE REAR TO THE FRONT SWALE. Trees or clusters of vegetation that would restrict flow Sec 300.03 C-G. Sec 300.03 C-G. Show any trees or clusters of vegetation that would restrict flow along the sidelines to the front swale, drainage ditch, or other drainage conveyance. Flatwork, i.e., slabs, walkways, hardscaping Sec 300.03 C1F "Flatwork, i.e., slabs, walkways, hardscaping, patios, decking, or AC pads, are not allowed in any utility easements/ drainage conveyance. Additionally, decorative objects, columns, light poles, mulch, stones, plantings, or landscaping of any kind are not allowed in the Right of Way. I am approving this inspection as a courtesy and as noted that you will need to remove/relocate tree in rear left property corner before Row final passage. 12/13/2024 - PREVIOUS INSPECTION NOTES 12/13/24 You must first submit and pass a final survey before a field survey inspection can be completed. I am not going to fee you today as a courtesy. Please submit your final survey and schedule a final survey inspection.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/13/2024 Disapproved - NO FEE FSLADISH
Note: 12/13/24 You must first submit and pass a final survey before a field survey inspection can be completed. I am not going to fee you today as a courtesy. Please submit your final survey and schedule a final survey inspection.
SEWER TIE IN 10/21/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2075 Inspector Notes from Inspection 2060 HAVE CORRECT PLUMBING SUB CONTRACTOR CHANGED TO CORRECT ONE BY NEXT INSPECTION BOTH GRAVITY SEWER AND SEWER TIE IN ARE APPROVED, C/M TO SHEDUAL SEWER TIE IN FOR 10/21/24
GRAVITY SEWER TEST 10/18/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 HAVE CORRECT PLUMBING SUB CONTRACTOR CHANGED TO CORRECT ONE BY NEXT INSPECTION BOTH GRAVITY SEWER AND SEWER TIE IN ARE APPROVED, C/M TO SHEDUAL SEWER TIE IN FOR 10/21/24
ROW- PRE-APRON (PRE-POUR) 10/04/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 9270 10/2/24 PIPE ELEVATION OK A COUPLE HUNDRETHS OUT ON THE DOWNSTREAM BUT ADJOINING CULVERT IS LOWER SO APPROVING THIS AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/1/2024 - PREVIOUS INSPECTION NOTES 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 SITE IS UNDER WATER UNABLE TO INSPECT AT THIS TIME. SEE PHOTO FOR REFERENCE. 8/19/2024 - PREVIOUS INSPECTION NOTES 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 10/04/2024 APPROVED FSLADISH
Note: 10/4/24 READY TO LAY PAVERS AT THE TIME OF THIS INSPECTION. _____________________________________________________________________________________________________________________ New inspection due to canceled inspection Inspector Notes from Inspection 9270 10/2/24 PIPE ELEVATION OK A COUPLE HUNDRETHS OUT ON THE DOWNSTREAM BUT ADJOINING CULVERT IS LOWER SO APPROVING THIS AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/1/2024 - PREVIOUS INSPECTION NOTES 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 SITE IS UNDER WATER UNABLE TO INSPECT AT THIS TIME. SEE PHOTO FOR REFERENCE. 8/19/2024 - PREVIOUS INSPECTION NOTES 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ROW- PAVER RESTRAINTS 10/04/2024 APPROVED FSLADISH
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 10/02/2024 APPROVED - AS NOTED FSLADISH
Note: 10/2/24 PIPE ELEVATION OK A COUPLE HUNDRETHS OUT ON THE DOWNSTREAM BUT ADJOINING CULVERT IS LOWER SO APPROVING THIS AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/1/2024 - PREVIOUS INSPECTION NOTES 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 SITE IS UNDER WATER UNABLE TO INSPECT AT THIS TIME. SEE PHOTO FOR REFERENCE. 8/19/2024 - PREVIOUS INSPECTION NOTES 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 10/01/2024 CANCELLED BY APPLICANT FSLADISH
Note: 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 SITE IS UNDER WATER UNABLE TO INSPECT AT THIS TIME. SEE PHOTO FOR REFERENCE. 8/19/2024 - PREVIOUS INSPECTION NOTES 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ELECTRIC - EARLY POWER 09/11/2024 APPROVED - AS NOTED KSANDOE
Note: Release Power
ROW- PRE-APRON (PRE-POUR) 09/09/2024 Disapproved -FEE REQUIRED FSLADISH
Note: 9/9/24 SITE IS UNDER WATER UNABLE TO INSPECT AT THIS TIME. SEE PHOTO FOR REFERENCE. PLEASE REMOVE PALLETS OF PAVERS ONTO YOUR SITE OUT OF THE CITY STREET AS SOON AS POSSIBLE THIS IS A SAFETY HAZARD. ___________________________________________________________________________________________________________________________ 8/19/2024 - PREVIOUS INSPECTION NOTES 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 08/19/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) THERE IS NO PAVER DETAIL UPLOADED IN TO THE PERMIT NEED TO HAVE SO WE CAN INSPECT DRIVEWAY CORRECTLY. 2) THE SITE PLAN CALLS FOR A CONCRETE DRIVEWAY AND ON SITE IT IS NOT FORM FOR A CONCRETE DRIVEWAY. ---------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 08/14/2024 CANCELLED BY APPLICANT FSLADISH
ROW- PRE-APRON (PRE-POUR) 08/13/2024 CANCELLED BY APPLICANT WEB
PEP TANK INSTALLATION REQUEST 06/24/2024 APPROVED CBOWERMASTER
INSULATION 06/06/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 6/6/24 Nail plate still missing from previous inspection 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24: 1). Fireblocking (minimum 1-1/2" thick per FBC-R302.11.1) required in garage where dryer exhaust, vent stack & electric wires enter attic space. Also, will need firestopat any seams & perimeter. Also, you will need to expose the top plate where the nail plate was missing previously so we can verify that it was resolved. 5/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet. 5-28-24 1. Need fire blocking in master shower. 2. Need fire blocking at entry from garage to house on right side wall. 3. Need fire blocking/ foam at electrical panels, vent pipe and dryer duct. 4. Silt fence is still down.
INSULATION 06/06/2024 APPROVED MKRASKI
Note: 6/6/2024 - PREVIOUS INSPECTION NOTES 6/6/24 Nail plate still missing from previous inspection 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24: 1). Fireblocking (minimum 1-1/2" thick per FBC-R302.11.1) required in garage where dryer exhaust, vent stack & electric wires enter attic space. Also, will need firestopat any seams & perimeter. Also, you will need to expose the top plate where the nail plate was missing previously so we can verify that it was resolved. 5/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet. 5-28-24 1. Need fire blocking in master shower. 2. Need fire blocking at entry from garage to house on right side wall. 3. Need fire blocking/ foam at electrical panels, vent pipe and dryer duct. 4. Silt fence is still down.
INSULATION 06/05/2024 CANCELLED BY APPLICANT WEB
Note: 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24: 1). Fireblocking (minimum 1-1/2" thick per FBC-R302.11.1) required in garage where dryer exhaust, vent stack & electric wires enter attic space. Also, will need firestopat any seams & perimeter. Also, you will need to expose the top plate where the nail plate was missing previously so we can verify that it was resolved. 5/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet. 5-28-24 1. Need fire blocking in master shower. 2. Need fire blocking at entry from garage to house on right side wall. 3. Need fire blocking/ foam at electrical panels, vent pipe and dryer duct. 4. Silt fence is still down.
INSULATION 05/31/2024 Disapproved - NO FEE RSIMS
Note: 5/31/24: 1). Fireblocking (minimum 1-1/2" thick per FBC-R302.11.1) required in garage where dryer exhaust, vent stack & electric wires enter attic space. Also, will need firestopat any seams & perimeter. Also, you will need to expose the top plate where the nail plate was missing previously so we can verify that it was resolved. 5/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet. 5-28-24 1. Need fire blocking in master shower. 2. Need fire blocking at entry from garage to house on right side wall. 3. Need fire blocking/ foam at electrical panels, vent pipe and dryer duct. 4. Silt fence is still down.
INSULATION 05/28/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: Inspector Notes from Inspection 2420 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet. 5-28-24 1. Need fire blocking in master shower. 2. Need fire blocking at entry from garage to house on right side wall. 3. Need fire blocking/ foam at electrical panels, vent pipe and dryer duct. 4. Silt fence is still down.
ALL ROUGH 05/21/2024 APPROVED - AS NOTED RSIMS
Note: 5/21/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Nail plates in laundry room are incomplete. Only 1 installed at the double top plate. 2). Please repair your silt fence and keep it maintained throughout the build process to avoid failed inspections with fee. FBC 3307.1 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet.
ALL ROUGH 05/14/2024 Disapproved -FEE REQUIRED RSIMS
Note: 5/14/24: 1). Missing Nail Plates for wire protection: (Marked with NP where needed) - 2-laundry / 2-left side / 1-middle closet / 2-Master Bedroom / 1-garage. Please check all that are under 1-1/4" minimum from stud/plate face. 2). No water pressure. 3). Shower faucet plumbing is incomplete. 4). Wires for Mechanical equipment are not phased out. 5). Kitchen exhaust is missing the 3 screws at connections as required. M1601.4.1 Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 6). Shingles installed but dryer gooseneck & plumbing vent stack boots are not installed. 7). Need a revision for the different windows installed (5823.1) than what shows on the submitted product approval sheet.
LATH/BRICK/ WATER BARRIER 05/14/2024 APPROVED RSIMS
ROOF VALLEY & METAL 04/17/2024 APPROVED RSIMS
Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 4/16/24: Previously noted 2 ply truss 28 remains unresolved. (2 rows - 4"OC). Please look at highlighted information on plans as stated before. Previously listed item 1 below: The flashing needs to be mechanically fastened to the wall with drive pins, tapcons or similar. Roof cement alone is not a sufficient means of attaching. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: 1). 5" x 5" wall flashing needs to be sealed to the wall along the top leg as required by Manufacturer. 2). 5" x 5" flashing at left side of entry needs to be anchored to concrete wall and sealed as required. * Also, 2ply truss 28 still needs to be connected as required on MiTek along the bottom cord. Inspector Notes from Inspection 2460 3/28/24: Must be complete by next inspection. 1). 2ply trusses - 08, 22 and 28 are not connected as required. Highlighted on MiTek. Each row has to meet OC spacing individually. 2). 09 truss has a split web which will need repair per MiTek requirements. Inspector Notes from Inspection 2450 Check the following by next inspection 1. missing blocking at panel edges (paned edges cannot be properly nailed at collumns, missing blocking/backing) Peer manufacturer specs 2. Need repairs to silt fence by next inspection (right side fence is down)
ROOF VALLEY & METAL 04/16/2024 Disapproved -FEE REQUIRED RSIMS
Note: 4/16/24: Previously noted 2 ply truss 28 remains unresolved. (2 rows - 4"OC). Please look at highlighted information on plans as stated before. Previously listed item 1 below: The flashing needs to be mechanically fastened to the wall with drive pins, tapcons or similar. Roof cement alone is not a sufficient means of attaching. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: 1). 5" x 5" wall flashing needs to be sealed to the wall along the top leg as required by Manufacturer. 2). 5" x 5" flashing at left side of entry needs to be anchored to concrete wall and sealed as required. * Also, 2ply truss 28 still needs to be connected as required on MiTek along the bottom cord. Inspector Notes from Inspection 2460 3/28/24: Must be complete by next inspection. 1). 2ply trusses - 08, 22 and 28 are not connected as required. Highlighted on MiTek. Each row has to meet OC spacing individually. 2). 09 truss has a split web which will need repair per MiTek requirements. Inspector Notes from Inspection 2450 Check the following by next inspection 1. missing blocking at panel edges (paned edges cannot be properly nailed at collumns, missing blocking/backing) Peer manufacturer specs 2. Need repairs to silt fence by next inspection (right side fence is down)
ROOF VALLEY & METAL 04/10/2024 Disapproved - NO FEE RSIMS
Note: 4/10/24: 1). 5" x 5" wall flashing needs to be sealed to the wall along the top leg as required by Manufacturer. 2). 5" x 5" flashing at left side of entry needs to be anchored to concrete wall and sealed as required. * Also, 2ply truss 28 still needs to be connected as required on MiTek along the bottom cord. Inspector Notes from Inspection 2460 3/28/24: Must be complete by next inspection. 1). 2ply trusses - 08, 22 and 28 are not connected as required. Highlighted on MiTek. Each row has to meet OC spacing individually. 2). 09 truss has a split web which will need repair per MiTek requirements. Inspector Notes from Inspection 2450 Check the following by next inspection 1. missing blocking at panel edges (paned edges cannot be properly nailed at collumns, missing blocking/backing) Peer manufacturer specs 2. Need repairs to silt fence by next inspection (right side fence is down)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/28/2024 APPROVED - AS NOTED RSIMS
Note: 3/28/24: Must be complete by next inspection. 1). 2ply trusses - 08, 22 and 28 are not connected as required. Highlighted on MiTek. Each row has to meet OC spacing individually. 2). 09 truss has a split web which will need repair per MiTek requirements. Inspector Notes from Inspection 2450 Check the following by next inspection 1. missing blocking at panel edges (paned edges cannot be properly nailed at collumns, missing blocking/backing) Peer manufacturer specs 2. Need repairs to silt fence by next inspection (right side fence is down)
WALL SHEATHING 03/25/2024 APPROVED - AS NOTED LMILLER
Note: Check the following by next inspection 1. missing blocking at panel edges (paned edges cannot be properly nailed at collumns, missing blocking/backing) Peer manufacturer specs 2. Need repairs to silt fence by next inspection (right side fence is down)
TIE BEAM / LINTEL 02/16/2024 APPROVED RSIMS
FOUND SURVEY APPROVED (OFFICE) 02/06/2024 APPROVED TBAKER
MONOLITHIC SLAB 01/25/2024 APPROVED RSIMS
Note: 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24: * 6 mil plastic has blown off of slab area. Please re-secure at seams thoroughly to prevent a re-occurrence. 1/19/2024 - PREVIOUS INSPECTION NOTES 1/19/24: 1). Rear Middle column footer has rebar that does not have the minimum 3" ground clearance as required. 2). Rear footer has roots that need to be removed. Highlighted on plan. * Please clean out minor washin dirt throughout a few areas of the footers to maintain 3" clearance for rebar.
MONOLITHIC SLAB 01/23/2024 Disapproved -FEE REQUIRED RSIMS
Note: 1/23/24: * 6 mil plastic has blown off of slab area. Please re-secure at seams thoroughly to prevent a re-occurrence. 1/19/2024 - PREVIOUS INSPECTION NOTES 1/19/24: 1). Rear Middle column footer has rebar that does not have the minimum 3" ground clearance as required. 2). Rear footer has roots that need to be removed. Highlighted on plan. * Please clean out minor washin dirt throughout a few areas of the footers to maintain 3" clearance for rebar.
MONOLITHIC SLAB 01/19/2024 Disapproved - NO FEE RSIMS
Note: 1/19/24: 1). Rear Middle column footer has rebar that does not have the minimum 3" ground clearance as required. 2). Rear footer has roots that need to be removed. Highlighted on plan. * Please clean out minor wash-in dirt throughout a few areas of the footers to maintain 3" clearance for rebar.
PLUMBING 1ST ROUGH UNDERGROUND 01/12/2024 APPROVED - AS NOTED MGIBSON
Note: HAVE CORRECT PLUMBING SUB CONTRACTOR CHANGED TO CORRECT ONE BY NEXT INSPECTION
WATER METER INSTALLATION REQUEST 12/04/2023 APPROVED CBOWERMASTER
Note: 11/22/2023 3:16:42 PM- PREVIOUS INSPECTION NOTES wooded lot
WATER METER INSTALLATION REQUEST 11/22/2023 Disapproved -FEE REQUIRED CBOWERMASTER
Note: wooded lot

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/17/2025 01/17/2025
Note: Marked INFORMATION By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Rename file name to match document.
MECH COMPLETE 01/08/2025 01/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 09/05/2024 09/05/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please bring in original right of way agreement
SW1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 approval valid with the following note: Final PEP location to be provided by the City of Palm Coast. The stormwater conveyance swales associated with the lot’s grading shall be diverted around the PEP lids/covers SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2024 09/06/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 09/03/2024 09/04/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Repeat Comment: 1) Please provide proposed sod elevations at the structure 4" below FFE for block, 6" below FFE for wood frame. 2) Please provide proposed elevations showing drainage within 10' from the structure A 5% slope for 10’ totaling 0.5’ elevation difference perpendicular to the structure is a requirement of the Florida Building Code Section 1804.4 3) Please provide driveway apron width at edge of pavement See revision clouds and notes on site plan
ENGIN1 COMPLETE 09/03/2024 09/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 09/03/2024 09/03/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Please submit an electronic copy of a completed Right of Way Utilization Agreement for Paver Driveway for staff review. This Agreement must be signed by all persons on the deed to the property and alll owner's signatures must be notarized.
ENGIN1 COMPLETE 08/27/2024 08/28/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 08/27/2024 08/27/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide proposed sod elevations at the structure 4" below FFE for block, 6" below FFE for wood frame. 2) Please provide proposed elevations showing drainage within 10' from the structure A 5% slope for 10’ totaling 0.5’ elevation difference perpendicular to the structure is a requirement of the Florida Building Code Section 1804.4 3) Please provide driveway apron width at edge of pavement
ZON HOLD 08/27/2024 08/27/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit an electronic copy of a completed Right of Way Utilization Agreement for Paver Driveway for staff review. This Agreement must be signed by all persons on the deed to the property and alll owner's signatures must be notarized.
BLD COMPLETE 05/14/2024 05/20/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM KS
ZON COMPLETE 02/06/2024 02/06/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/06/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/10/2024 01/10/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 11/06/2023 11/08/2023
Note: Released By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM
ELEC COMPLETE 11/06/2023 11/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 11/06/2023 11/17/2023
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/06/2023 11/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SWALE COMPLETE 10/16/2023 12/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 10/13/2023 10/14/2023
Note: Released By: JPI
CUSVC COMPLETE 10/13/2023 10/16/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 10/13/2023 10/16/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a 400 amp riser diagram.
ENGIN1 COMPLETE 10/13/2023 10/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 10/13/2023 10/16/2023
LOCATE COMPLETE 10/13/2023 10/17/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/13/2023 10/16/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 10/13/2023 10/24/2023
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM Sod elevations adjacent to the structure are 4” below the FFE for block and 6” forwood frame structures. (D) Culvert material and size to be depicted. Typical is 17X13 CMP (L)
ZON HOLD 10/13/2023 10/16/2023
Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Must have separation between front of home with walkway and additional foundation plantings. Provide NEW Site plan and Landscape plan showing the separation.
BADMIN COMPLETE 10/13/2023 10/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
REINSPECTION RESIDENTIAL ¤40.00 01/16/2025
SW ENG REINSPECTION 30 ¤30.00 01/16/2025
REINSPECTION FEE ¤40.00 01/16/2025
RECORDING FEE REIMBURSE DOC ¤44.00 01/16/2025
REINSPECTION FEE ¤40.00 01/15/2024
CONTRACTOR CHANGE ¤20.00 01/15/2024
FC IMPACT FEE EMS ¤62.00 11/17/2023
IMPACT FEE FIRE ¤428.09 11/17/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/17/2023
FC IMPACT FEE LIBRARY ¤268.00 11/17/2023
IMPACT FEE PARKS ¤1,800.99 11/17/2023
IMPACT FEE SCHOOL ¤5,450.00 11/17/2023
WATER- TURN ON ¤25.00 11/17/2023
ADJUSTMENT 50% (¤1,409.35) 11/17/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/17/2023
INSPECTION - RESIDENTIAL ¤2,172.50 11/17/2023
PLAN REVIEW - RESIDENTIAL ¤616.20 11/17/2023
CONNECTION FEES ¤1,166.26 11/17/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 11/17/2023
WATER -IRRIGATION INSPECTION ¤25.00 11/17/2023
SURCHARGE FS 533.721 ¤14.09 11/17/2023
SURCHARGE - FS 468.631 ¤21.14 11/17/2023
SW ENG - FOUNDATION SURVEY ¤20.00 11/17/2023
SW ENG INSPECTION 80 ¤80.00 11/17/2023
SW ENG PRE APRON ¤30.00 11/17/2023
SW ENG - REVIEW 20 ¤20.00 11/17/2023
SW ENG RES REVIEW 200 ¤200.00 11/17/2023
SEWER CREDIT (¤1,466.00) 11/17/2023
SEWER INSPECTION ¤25.00 11/17/2023
SEWER CAPITAL FACILITY ¤5,344.82 11/17/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 11/17/2023
SITE PLAN 30 ¤30.00 11/17/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,354.12