I want to search for...

Permit #2023100654

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00310-0200
CONDITIONED SPACE: 1600 sqft
OPENED PORCH (WITH ROOF) : 63 sqft
OPENED PORCH (WITH ROOF) : 513 sqft
GARAGE: 499 sqft
Total Square Footage: 2675 sqft
Block: 00310
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 407-580-2657
Location Address: 33 RADFORD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/13/2023
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: YELIOSOF DMITRY & OLGA YELIOSOF TRUSTEES

Address

51 BIONIA AVE

STATEN ISLAND, NY 10305

Lot: 0200
Contracted Stated Job Value: ¤391,976.00
Job Description: Single Family Home
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

KERRY DWAIN AYLESWORTH II
Status Location Address Mailing Address State License Number Phone
ACTIVE

2820 LEWIS SPEEDWAY

ST AUGUSTINE, FL 32084

STE B

ST AUGUSTINE, FL 32084

CAC1820713 (Exp: 08/31/2026) 904-342-5709
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/10/2025 APPROVED CVANSTRAHLEN
Note:
BLD - BUILDING FINAL 03/07/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: please fix items before next inspection seal all penetration on mechanical room #7-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) around boxes
BLD - BUILDING FINAL 02/12/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: 2 items reamin on the past inspection that need to be resolved *** NOTES ADDED BY CVANSTRAHLEN 2/7/2025 9:16:32 AM *** #7-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) around boxes #3- Need insulation certificate , insulation certificade need to show that the attic about garage , the foam roof joins is been fire rate proof by code
BLD - BUILDING FINAL 02/07/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 2/7/2025 9:16:32 AM *** #7-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) around boxes #1- refrigerator electrical outlet need to be o a GFCI breaker #2-range hood electrical outlet need to be on a GFCI breaker #3- Need insulation certificate #4- Exterior outlet , next to AC unit have some burn marks , ( replacement need it ) #5- E-cals call for unvented sotfit , ( vent sotfit is install on property #6- MIssing one anker bold on each of the garage door jamb
U -UTILITY RESIDENTIAL FINAL 02/07/2025 FINAL APPROVED LFITZGERALD
Note: 11/4/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 11/4/2024 10:41:57 AM *** lower both sewer clean outs-install correct cap on C/O at pep tank Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:06:41 AM *** no irrigation-no cross connection
ROW - STORMWATER FINAL 11/20/2024 APPROVED FSLADISH
Note: 11/20/24AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________ 11/4/2024 - PREVIOUS INSPECTION NOTES 11/04/24 TPOLACEK*** ALL BARE EARTH ALONG VACANT LOT MUST HAVE SEED AND STRAW
ROW - FINAL APRON (AFTER POUR) 11/20/2024 APPROVED - AS NOTED FSLADISH
Note: 11/20/24 HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION.. PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 11/4/2024 - PREVIOUS INSPECTION NOTES 11/04/24 TPOLACEK*** BUILDER MUST COMPLETE THE ROADSIDE HOT PATCH REPAIR. ALL DAMAGED ASPHALT MUST BE CUT OUT AND REPLACED A MINIMUM OF 12" FROM EXISTING EDGE.
ROW - FINAL APRON (AFTER POUR) 11/04/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 11/04/24 TPOLACEK*** BUILDER MUST COMPLETE THE ROADSIDE HOT PATCH REPAIR. ALL DAMAGED ASPHALT MUST BE CUT OUT AND REPLACED A MINIMUM OF 12" FROM EXISTING EDGE.
ROW - STORMWATER FINAL 11/04/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 11/04/24 TPOLACEK*** ALL BARE EARTH ALONG VACANT LOT MUST HAVE SEED AND STRAW
U -UTILITY RESIDENTIAL FINAL 11/04/2024 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 11/4/2024 10:41:57 AM *** lower both sewer clean outs-install correct cap on C/O at pep tank Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:06:41 AM *** no irrigation-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/31/2024 APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9270 05/23/24 TPOLACEK*** NOTE TO BUILDER. REBAR MAY NOT BE BENT MUST BE A MINIMUM OF THE WIDTH OF THE PIPE BUT NEEDS TO A STRAIGHT CUT PIECE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ROW FIELD SURVEY /GRADING CERTIFICATION 10/31/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ELECTRIC - EARLY POWER 08/20/2024 APPROVED AGAETANO
GRAVITY SEWER TEST 07/29/2024 APPROVED MGIBSON
Note: 12/14/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET
SEWER TIE IN 07/29/2024 APPROVED MGIBSON
U-CROSS CONNECTION 07/29/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:06:41 AM *** no irrigation-no cross connection
ROW- PRE-APRON (PRE-POUR) 05/23/2024 APPROVED - AS NOTED TPOLACEK
Note: 05/23/24 TPOLACEK*** NOTE TO BUILDER. REBAR MAY NOT BE BENT MUST BE A MINIMUM OF THE WIDTH OF THE PIPE BUT NEEDS TO A STRAIGHT CUT PIECE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
PEP TANK INSTALLATION REQUEST 05/06/2024 APPROVED CBOWERMASTER
INSULATION 04/16/2024 APPROVED AGAETANO
LATH/BRICK/ WATER BARRIER 04/08/2024 APPROVED AGAETANO
Note: 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Holes in exterior block need moisture barrier and lath check all 4/1/2024 - PREVIOUS INSPECTION NOTES 04-01-2024 1. Approved drawings not on site. 2. Back two exterior doors and front entry doors not installed.
ALL ROUGH 04/05/2024 APPROVED - AS NOTED AGAETANO
Note: 4/4/2024 - PREVIOUS INSPECTION NOTES 04-04-2024 1. Head test failed. 2. Energy calcs and mechanical layout not on site. 3. P.A.S. not on site. 4. Please seal holes at M.Bedroom at left of entry electrical wire to the outside. 04-05-2024 1. Shield plate not installed correctly at garage water lines at slab. Check at next inspection. 2. Mechanical layout is blurry and unable to resd. Please have a large, readable, approved layout on site. Check at next inspction.
ALL ROUGH 04/04/2024 Disapproved - NO FEE AGAETANO
Note: 04-04-2024 1. Head test failed. 2. Energy calcs and mechanical layout not on site. 3. P.A.S. not on site. 4. Please seal holes at M.Bedroom at left of entry electrical wire to the outside.
LATH/BRICK/ WATER BARRIER 04/03/2024 Disapproved - NO FEE MKRASKI
Note: 4/3/24 Holes in exterior block need moisture barrier and lath check all 4/1/2024 - PREVIOUS INSPECTION NOTES 04-01-2024 1. Approved drawings not on site. 2. Back two exterior doors and front entry doors not installed.
ALL ROUGH 04/03/2024 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 04/01/2024 Disapproved - NO FEE AGAETANO
Note: 04-01-2024 1. Approved drawings not on site. 2. Back two exterior doors and front entry doors not installed.
ROOF VALLEY & METAL 03/12/2024 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/11/2024 APPROVED JWALKER
Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 3/7/24 Make ALL repairs before calling in re-inspection,stopped inspection items not repaired per previous notes 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24: All previously listed deficiencies are not resolved. * Item 2: Approved repair letter is not in plan documents as required. Also, the repair does not meet the Engineer's requirements. * Item 3 - Truss (3) 2 of 2 is not repaired at all. * Item 9 - Still missing truss plates / moisture barrier on some trusses. Re-check all. * Item 10 - Still missing braces at top convential framing as required. * Item 11 - Truss 21 will need to be braced to parrallel truss where is bowed on the right side to maintain 24" OC separation. 2/26/2024 - PREVIOUS INSPECTION NOTES 1. Trusses 17 and 10 missing 1 of 2 required heta 20 anchors. 2. Truss (3) 1 of 2, Has a missing a web member. Please have the engineer submit a repair to the building department to correct the missing web. 3. Truss (3) 2 of 2 and truss (6) have broken web members. Please see the Mitek repair page for correct repair methods. 4. Truss PG7 and 2 PC1's Rear proch right corner are missing heta hold down anchors. 5. The piggy back trusses have not been anchored down to the base trusses. See the mitek piggy back anchoring method in the engineering packet. 6. Front proch 2x beam support above the front entry needs to be anchored to the CMU wall below. 7. Bearing wall SP achor top and bottom missing fasteners. All nail holes are to be filled. Check all. 8. Fornt entry 6x6 post base ABU anchor is missing fasteners. 9. Multiple trusses are missing truss plates or a moisture barrier. Check all. 10. The over framing at the front entry is missing hold down anchors. The ridge beam needs to be supported and anchored to the trusses below. 11. Trusses in the garage right side bearing wall are out of plumb tolerance. 9.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/07/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 3/7/24 Make ALL repairs before calling in re-inspection,stopped inspection items not repaired per previous notes 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24: All previously listed deficiencies are not resolved. * Item 2: Approved repair letter is not in plan documents as required. Also, the repair does not meet the Engineer's requirements. * Item 3 - Truss (3) 2 of 2 is not repaired at all. * Item 9 - Still missing truss plates / moisture barrier on some trusses. Re-check all. * Item 10 - Still missing braces at top convential framing as required. * Item 11 - Truss 21 will need to be braced to parrallel truss where is bowed on the right side to maintain 24" OC separation. 2/26/2024 - PREVIOUS INSPECTION NOTES 1. Trusses 17 and 10 missing 1 of 2 required heta 20 anchors. 2. Truss (3) 1 of 2, Has a missing a web member. Please have the engineer submit a repair to the building department to correct the missing web. 3. Truss (3) 2 of 2 and truss (6) have broken web members. Please see the Mitek repair page for correct repair methods. 4. Truss PG7 and 2 PC1's Rear proch right corner are missing heta hold down anchors. 5. The piggy back trusses have not been anchored down to the base trusses. See the mitek piggy back anchoring method in the engineering packet. 6. Front proch 2x beam support above the front entry needs to be anchored to the CMU wall below. 7. Bearing wall SP achor top and bottom missing fasteners. All nail holes are to be filled. Check all. 8. Fornt entry 6x6 post base ABU anchor is missing fasteners. 9. Multiple trusses are missing truss plates or a moisture barrier. Check all. 10. The over framing at the front entry is missing hold down anchors. The ridge beam needs to be supported and anchored to the trusses below. 11. Trusses in the garage right side bearing wall are out of plumb tolerance. 9.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/01/2024 Disapproved -FEE REQUIRED RSIMS
Note: 3/1/24: All previously listed deficiencies are not resolved. * Item 2: Approved repair letter is not in plan documents as required. Also, the repair does not meet the Engineer's requirements. * Item 3 - Truss (3) 2 of 2 is not repaired at all. * Item 9 - Still missing truss plates / moisture barrier on some trusses. Re-check all. * Item 10 - Still missing braces at top convential framing as required. * Item 11 - Truss 21 will need to be braced to parrallel truss where is bowed on the right side to maintain 24" OC separation. 2/26/2024 - PREVIOUS INSPECTION NOTES 1. Trusses 17 and 10 missing 1 of 2 required heta 20 anchors. 2. Truss (3) 1 of 2, Has a missing a web member. Please have the engineer submit a repair to the building department to correct the missing web. 3. Truss (3) 2 of 2 and truss (6) have broken web members. Please see the Mitek repair page for correct repair methods. 4. Truss PG7 and 2 PC1's Rear proch right corner are missing heta hold down anchors. 5. The piggy back trusses have not been anchored down to the base trusses. See the mitek piggy back anchoring method in the engineering packet. 6. Front proch 2x beam support above the front entry needs to be anchored to the CMU wall below. 7. Bearing wall SP achor top and bottom missing fasteners. All nail holes are to be filled. Check all. 8. Fornt entry 6x6 post base ABU anchor is missing fasteners. 9. Multiple trusses are missing truss plates or a moisture barrier. Check all. 10. The over framing at the front entry is missing hold down anchors. The ridge beam needs to be supported and anchored to the trusses below. 11. Trusses in the garage right side bearing wall are out of plumb tolerance. 9.
WALL SHEATHING 02/26/2024 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/26/2024 Disapproved -FEE REQUIRED JWALKER
Note: 1. Trusses 17 and 10 missing 1 of 2 required heta 20 anchors. 2. Truss (3) 1 of 2, Has a missing a web member. Please have the engineer submit a repair to the building department to correct the missing web. 3. Truss (3) 2 of 2 and truss (6) have broken web members. Please see the Mitek repair page for correct repair methods. 4. Truss PG7 and 2 PC1's Rear proch right corner are missing heta hold down anchors. 5. The piggy back trusses have not been anchored down to the base trusses. See the mitek piggy back anchoring method in the engineering packet. 6. Front proch 2x beam support above the front entry needs to be anchored to the CMU wall below. 7. Bearing wall SP achor top and bottom missing fasteners. All nail holes are to be filled. Check all. 8. Fornt entry 6x6 post base ABU anchor is missing fasteners. 9. Multiple trusses are missing truss plates or a moisture barrier. Check all. 10. The over framing at the front entry is missing hold down anchors. The ridge beam needs to be supported and anchored to the trusses below. 11. Trusses in the garage right side bearing wall are out of plumb tolerance. 9.
FOUND SURVEY APPROVED (OFFICE) 02/22/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/02/2024 APPROVED JWALKER
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES Item 1 listed below has not been corrected. 1/30/2024 - PREVIOUS INSPECTION NOTES 1. Rear porch lintel at the right side and rear missing top rebar. 2. front left side garage top horizontal rebar is to have 3/4" minimum clearance off block.
TIE BEAM / LINTEL 01/31/2024 Disapproved -FEE REQUIRED JWALKER
Note: Item 1 listed below has not been corrected. 1/30/2024 - PREVIOUS INSPECTION NOTES 1. Rear porch lintel at the right side and rear missing top rebar. 2. front left side garage top horizontal rebar is to have 3/4" minimum clearance off block.
TIE BEAM / LINTEL 01/30/2024 Disapproved - NO FEE JWALKER
Note: 1. Rear porch lintel at the right side and rear missing top rebar. 2. front left side garage top horizontal rebar is to have 3/4" minimum clearance off block.
MONOLITHIC SLAB 01/02/2024 APPROVED JWALKER
Note: 12/22/2023 - PREVIOUS INSPECTION NOTES 12/22/23 Item 2 listed below has not been completed. 12/21/2023 - PREVIOUS INSPECTION NOTES 1. Compaction test has not been posted. 2. Slab area including the rear porch needs to be tamped down. 3. Rear garage footing area has soil collapse under the plastic. Reabar is to have 3" clearance from the ground.
MONOLITHIC SLAB 12/22/2023 Disapproved - NO FEE JWALKER
Note: 12/22/23 Item 2 listed below has not been completed. 12/21/2023 - PREVIOUS INSPECTION NOTES 1. Compaction test has not been posted. 2. Slab area including the rear porch needs to be tamped down. 3. Rear garage footing area has soil collapse under the plastic. Reabar is to have 3" clearance from the ground.
MONOLITHIC SLAB 12/21/2023 Disapproved - NO FEE JWALKER
Note: 12/21/23 1. Compaction test has not been posted. 2. Slab area including the rear porch needs to be tamped down. 3. Rear garage footing area has soil collapse under the plastic. Reabar is to have 3" clearance from the ground.
MONOLITHIC SLAB 12/18/2023 CANCELLED BY APPLICANT JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 12/14/2023 APPROVED - AS NOTED MGIBSON
Note: NEED TO CHANGE PLUMBING SUB-CONTRACTOR TO CORRECT ONE
GRAVITY SEWER TEST 12/14/2023 Disapproved - NO FEE MGIBSON
Note: SEWER NOT RAN YET
WATER METER INSTALLATION REQUEST 12/04/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 11/07/2024 11/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 10/28/2024 10/28/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM invalid NOC
BADMIN INFORMATION 10/23/2024 10/23/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM can not process this as the NOC is expired.
BLD COMPLETE 02/27/2024 03/01/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/22/2024 02/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/22/2024 02/22/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ZON COMPLETE 02/22/2024 02/22/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 10/16/2023 10/17/2023
Note: Released By: JPI
CUSVC COMPLETE 10/16/2023 10/17/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/16/2023 10/17/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/16/2023 10/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 10/16/2023 10/17/2023
LOCATE COMPLETE 10/16/2023 10/18/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/16/2023 10/17/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/16/2023 10/24/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 10/16/2023 10/17/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 10/16/2023 12/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
REINSPECTION RESIDENTIAL ¤40.00 03/19/2025
CONTRACTOR CHANGE ¤20.00 03/19/2025
REINSPECTION FEE ¤40.00 03/19/2025
SW ENG REINSPECTION 20 ¤20.00 03/19/2025
SW ENG REINSPECTION 20 ¤20.00 03/19/2025
CONTRACTOR CHANGE ¤20.00 12/14/2023
FC IMPACT FEE EMS ¤62.00 11/13/2023
IMPACT FEE FIRE ¤428.09 11/13/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/13/2023
FC IMPACT FEE LIBRARY ¤268.00 11/13/2023
IMPACT FEE PARKS ¤1,800.99 11/13/2023
IMPACT FEE SCHOOL ¤5,450.00 11/13/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 11/13/2023
WATER -IRRIGATION INSPECTION ¤25.00 11/13/2023
CONNECTION FEES ¤1,166.26 11/13/2023
SW ENG - REVIEW 20 ¤20.00 11/13/2023
SW ENG RES REVIEW 200 ¤200.00 11/13/2023
SEWER CREDIT (¤1,733.75) 11/13/2023
SEWER INSPECTION ¤25.00 11/13/2023
SEWER CAPITAL FACILITY ¤5,344.82 11/13/2023
WATER CREDIT (¤1,390.00) 11/13/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 11/13/2023
SITE PLAN 30 ¤30.00 11/13/2023
SURCHARGE FS 533.721 ¤7.07 11/13/2023
SURCHARGE - FS 468.631 ¤10.60 11/13/2023
SW ENG - FOUNDATION SURVEY ¤20.00 11/13/2023
SW ENG INSPECTION 80 ¤80.00 11/13/2023
SW ENG PRE APRON ¤30.00 11/13/2023
WATER- TURN ON ¤25.00 11/13/2023
ADJUSTMENT 50% (¤706.88) 11/13/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/13/2023
INSPECTION - RESIDENTIAL ¤1,078.00 11/13/2023
PLAN REVIEW - RESIDENTIAL ¤305.76 11/13/2023
Fees Total Due: ¤0.00 Total Paid: ¤18,962.34