Permit #2023100831
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00090-0150 |
| CONDITIONED SPACE: 1298 sqft |
| CONDITIONED SPACE: 1298 sqft |
| GARAGE: 262 sqft |
| GARAGE: 262 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 3274 sqft |
| Block: 00090 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 863-647-5815 |
| Location Address: 43 PONY EXPRESS DR |
| Type: DU - DUPLEX |
| Issue Date: 12/01/2023 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address PO BOX 6254 LAKELAND, FL 33807 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤315,000.00 |
| Job Description: Duplex |
| Type: CN |
| Original Permit #: 2023031577 |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/29/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/29/2025 11:01:33 AM *** 9/25/2024 - PREVIOUS INSPECTION NOTES 9/25/24: 1). Temporary electric pole needs to be removed prior to Building Final Approval. 9/9/2024 - PREVIOUS INSPECTION NOTES NEC 210.30 (A) Whole house surge protector required for each unit FBCR M1305.1.4.1 ODU needs to be 3" above grade. 105.11 Notice of termite protection. A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel | |||
| ROW - STORMWATER FINAL | 10/18/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/18/24 WASHOUTS FILLED IN SODDED AND LEVEL AT THE TIME OF THIS INSPECTION. IT IS THE BUILDERS RESPONSIBILITY AFTER THIS INSPECTION FOR ANY FURTHER WASHOUTS. AT THE TIME OF THIS INSPECTION CORRECTIONS WERE MADE. APPROVING AS NOTED AT THIS INSPECTION NO WASHOUTS WERE OBSERVED. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ________________________________________________________________________________________________________________________ 9/25/2024 - PREVIOUS INSPECTION NOTES 09/25/24 TPOLACEK** WASHOUTS AROUND BOTH PEP TANKS NEEDS TO BE FILLED AND SOD NEEDS TO BE LEVEL WITH LID TO PREVENT FURTHER WASHOUTS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 NOTICED A WASHOUT AT THE PEP TANK AT THE TIME OF THIS INSPECTION. CM WAS WITH ME AND INDICATED HE WOULD TAKE CARE OF IT PROMPTLY. NOT GOING TO FEE HIM TODAY. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 7/17/24 Upon walking property determined that drainage will work as indicated. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - STORMWATER FINAL | 09/25/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09/25/24 TPOLACEK** WASHOUTS AROUND BOTH PEP TANKS NEEDS TO BE FILLED AND SOD NEEDS TO BE LEVEL WITH LID TO PREVENT FURTHER WASHOUTS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 NOTICED A WASHOUT AT THE PEP TANK AT THE TIME OF THIS INSPECTION. CM WAS WITH ME AND INDICATED HE WOULD TAKE CARE OF IT PROMPTLY. NOT GOING TO FEE HIM TODAY. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 7/17/24 Upon walking property determined that drainage will work as indicated. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| BLD - BUILDING FINAL | 09/25/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/25/2024 10:49:34 AM *** 9/25/24: 1). Temporary electric pole needs to be removed prior to Building Final Approval. 9/9/2024 - PREVIOUS INSPECTION NOTES NEC 210.30 (A) Whole house surge protector required for each unit FBCR M1305.1.4.1 ODU needs to be 3" above grade. 105.11 Notice of termite protection. A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel | |||
| BLD - BUILDING FINAL | 09/09/2024 | Disapproved - NO FEE | KSANDOE |
| Note: NEC 210.30 (A) Whole house surge protector required for each unit FBCR M1305.1.4.1 ODU needs to be 3" above grade. 105.11 Notice of termite protection. A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel | |||
| ROW - STORMWATER FINAL | 09/09/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 9/9/24 NOTICED A WASHOUT AT THE PEP TANK AT THE TIME OF THIS INSPECTION. CM WAS WITH ME AND INDICATED HE WOULD TAKE CARE OF IT PROMPTLY. NOT GOING TO FEE HIM TODAY. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 7/17/24 Upon walking property determined that drainage will work as indicated. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/09/2024 | APPROVED | FSLADISH |
| Note: 9/9/24 PIPE ELEVATION GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 7/17/24 Upon walking property determined that drainage will work as indicated. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U-CROSS CONNECTION | 08/19/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/19/2024 9:59:58 AM *** both units have potable irrigation with PVB each-no cross connection | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/17/2024 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/17/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/17/24 Upon walking property determined that drainage will work as indicated. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ELECTRIC - EARLY POWER | 07/08/2024 | APPROVED | LMILLER |
| Note: Inspector Notes from Inspection 2170 2/13/24: FPL emailed to release power. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/24/2024 | APPROVED | TPOLACEK |
| Note: 06/24/24 TPOLACEK*** AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/20/2024 - PREVIOUS INSPECTION NOTES 06/20/24 TPOLACEK*** CULVERT IS OUT OF TOLERENCE PLEASE MAKE SURE YOU ARE USING CORRECT BENCHMARK AND RESET PIPE TO CORRECT ELEVATION. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place | |||
| ROW- PRE-APRON (PRE-POUR) | 06/20/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 06/20/24 TPOLACEK*** CULVERT IS OUT OF TOLERENCE PLEASE MAKE SURE YOU ARE USING CORRECT BENCHMARK AND RESET PIPE TO CORRECT ELEVATION. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place | |||
| U - SEWER TIE IN | 06/12/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 REMOVE ALL VEGITATION FROM FOOTER/SLAB AREAS BEFORE SCHEDUALING SLAB INSPECTION | |||
| GRAVITY SEWER TEST | 06/12/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 REMOVE ALL VEGITATION FROM FOOTER/SLAB AREAS BEFORE SCHEDUALING SLAB INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 05/15/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 05/02/2024 | APPROVED | RSIMS |
| Note: 5/1/2024 - PREVIOUS INSPECTION NOTES 5/1/24: 1). As previously noted the draft stop at the front & back overhangs was never confirmed due to soffit being installed. Please remove enough of the soffit in both areas to view the draft stop. Side A: 2). Overflow at bathtub seems to be leaking as the concrete in the area is saturated & the overflow pipe from the faceplate to the tub waste tee connection is wet around the joints. 3). Missing firestop/fireblocking at top plate connection of bathtub pack out wall above faucet. (see how side B is done if clarification is needed). Inspector Notes from Inspection 2443 4/17/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO THE NEXT INSPECTION. Check at next inspection. Previously noted item 1 remains unresolved / Item 2 slab is not fully repaired to meet finish surface as required / Item 4 still not resolved. Also, the roof shingle installation has broken the dryer exhaust seal at the roof deck in Unit B. Please reseal properly as required. Field nails are still covered as well as the soffit is installed so the tail end of the truss cannot be seen for the drywall nailing. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. | |||
| INSULATION | 05/01/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/1/24: 1). As previously noted the draft stop at the front & back overhangs was never confirmed due to soffit being installed. Please remove enough of the soffit in both areas to view the draft stop. Side A: 2). Overflow at bathtub seems to be leaking as the concrete in the area is saturated & the overflow pipe from the faceplate to the tub waste tee connection is wet around the joints. 3). Missing firestop/fireblocking at top plate connection of bathtub pack out wall above faucet. (see how side B is done if clarification is needed). Inspector Notes from Inspection 2443 4/17/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO THE NEXT INSPECTION. Check at next inspection. Previously noted item 1 remains unresolved / Item 2 slab is not fully repaired to meet finish surface as required / Item 4 still not resolved. Also, the roof shingle installation has broken the dryer exhaust seal at the roof deck in Unit B. Please reseal properly as required. Field nails are still covered as well as the soffit is installed so the tail end of the truss cannot be seen for the drywall nailing. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. | |||
| FIREWALL DRYWALL NAILING | 04/17/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/17/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO THE NEXT INSPECTION. Check at next inspection. Previously noted item 1 remains unresolved / Item 2 slab is not fully repaired to meet finish surface as required / Item 4 still not resolved. Also, the roof shingle installation has broken the dryer exhaust seal at the roof deck in Unit B. Please reseal properly as required. Field nails are still covered as well as the soffit is installed so the tail end of the truss cannot be seen for the drywall nailing. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. Inspector Notes from Inspection 2420 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Could not verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. | |||
| ALL ROUGH | 04/10/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/10/24: Approved as noted to keep the project moving. Check at next Inspection. Must be complete prior to next inspection. Both Units: 1). Bathtub needs to be filled to the overflow to test piping. 2). Slab at bathtub drain needs to be repaired with cement as required. Currently filled with water. 3). Dining room window: Copuld noy verify proper anchoring due to it being labeled "Do not open until 3/18/24" 4). 5ft head pressure pipe outside is short , so please make sure it is filled to the very top of the pipe. | |||
| FIREWALL DRYWALL NAILING | 04/05/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/5/24: Screws are covered already. Unable to visually confirm spacing for draft stop. | |||
| LATH/BRICK/ WATER BARRIER | 04/05/2024 | APPROVED | RSIMS |
| ALL ROUGH | 04/03/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF VALLEY & METAL | 03/18/2024 | APPROVED | BTAYLOR |
| WALL SHEATHING | 03/11/2024 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/11/2024 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 03/08/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 02/20/2024 | APPROVED | FWILLIS |
| ELECTRIC TEMP POLE | 02/13/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 2/13/24: FPL emailed to release power. | |||
| MONOLITHIC SLAB | 02/12/2024 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: REMOVE ALL VEGITATION FROM FOOTER/SLAB AREAS BEFORE SCHEDUALING SLAB INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 01/24/2024 | APPROVED | BVITALE |
| Note: 1/17/2024 3:23:36 PM- PREVIOUS INSPECTION NOTES NCL | |||
| WATER METER INSTALLATION REQUEST | 01/17/2024 | Disapproved -FEE REQUIRED | BVITALE |
| Note: NCL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/07/2024 | 04/08/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/07/2024 | 04/08/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/28/2024 | 04/02/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide ductlayout complete(supply and return) for both sides of duplex. Also provide duct layout on floor plan or sheet other than electrical for readability | |||
| ENGIN1 | COMPLETE | 03/07/2024 | 03/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/07/2024 | 03/07/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/14/2023 | 11/22/2023 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/14/2023 | 11/14/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/02/2023 | 11/02/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 11/02/2023 | 11/13/2023 |
| Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D) You did the correction still need some information | |||
| ZON | COMPLETE | 11/02/2023 | 11/02/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/19/2023 | 12/07/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 10/18/2023 | 10/20/2023 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/18/2023 | 10/19/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/18/2023 | 10/23/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/18/2023 | 10/20/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/18/2023 | 10/25/2023 |
| Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM YOU NEED TO SIMPLIFY THE SITE PLAN BY REMOVING CONTOUR LINES AND ADD A SQUARE TO THE PROPOSED ELEVATION. | |||
| ZON | COMPLETE | 10/18/2023 | 10/19/2023 |
| Note: Released By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 01/30/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 01/30/2025 |
| REINSPECTION FEE | ¤40.00 | 01/30/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/30/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/30/2025 |
| CONNECTION FEES | ¤2,332.52 | 12/01/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/01/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/01/2023 |
| SEWER CREDIT | (¤6,229.13) | 12/01/2023 |
| SEWER INSPECTION | ¤25.00 | 12/01/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 12/01/2023 |
| WATER CREDIT | (¤25.71) | 12/01/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 12/01/2023 |
| SITE PLAN 30 | ¤30.00 | 12/01/2023 |
| SURCHARGE FS 533.721 | ¤5.11 | 12/01/2023 |
| SURCHARGE - FS 468.631 | ¤7.67 | 12/01/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/01/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/01/2023 |
| SW ENG PRE APRON | ¤30.00 | 12/01/2023 |
| WATER- TURN ON | ¤50.00 | 12/01/2023 |
| ADJUSTMENT 50% | (¤511.13) | 12/01/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/01/2023 |
| INSPECTION - RESIDENTIAL | ¤866.25 | 12/01/2023 |
| PLAN REVIEW - APPROVED MASTER | ¤126.00 | 12/01/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 12/01/2023 |
| IMPACT FEE FIRE | ¤856.18 | 12/01/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/01/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/01/2023 |
| IMPACT FEE PARKS | ¤3,600.18 | 12/01/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 12/01/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 12/01/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 12/01/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤34,492.84 |