I want to search for...
Permit #2023101057
Permit Details
Status: COED
| Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1 |
| Job Phone: 904-781-7060 |
| Location Address: 1 MAHOGANY RUN |
| Type: CFN - COMMERCIAL FENCE |
| Issue Date: 12/12/2023 |
| NOC: RECORDED |
| Applicant name: DANIEL WILLIAM BUTTERWORTH |
| Owner: TOLL SOUTHEAST LP CO INC |
|
Address 1140 VIRGINIA DRIVE FORT WASHINGTON, PA 19034 |
| Contracted Stated Job Value: ¤120,000.00 |
| Job Description: Rear Residence Entry Gates and Fence |
| Type: CN |
Contractor
ALL WEATHER CONTRACTORS INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1702 LINDSEY ROAD JACKSONVILLE, FL 32221 |
CGC1523954 (Exp: 08/31/2026) | 904-781-7060 | 904-619-5011 |
Sub Contractors
DEXTER GLENTON ALIE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
864 POYDRAS LN N JACKSONVILLE, FL 32219 |
EC13009280 (Exp: 08/31/2026) | 904-475-2961 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL | 08/20/2024 | FINAL APPROVED | FWILLIS |
| ELECTRIC FINAL | 08/19/2024 | APPROVED | RMARTIN |
| Note: 8/9/2024 - PREVIOUS INSPECTION NOTES 8/9/24 Contractor must meet onsite to test gates, control boxes are locked 7/19/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/19/2024 3:34:35 PM *** Need to call back in when power is on to test all equipment 7/16/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/16/2024 1:22:11 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES 7/8/2024 - PREVIOUS INSPECTION NOTES 1st rough elec. inspection was not done | |||
| ELECTRIC FINAL | 08/09/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 8/9/24 Contractor must meet onsite to test gates, control boxes are locked 7/19/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/19/2024 3:34:35 PM *** Need to call back in when power is on to test all equipment 7/16/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/16/2024 1:22:11 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES 7/8/2024 - PREVIOUS INSPECTION NOTES 1st rough elec. inspection was not done | |||
| LDSC- LANDSCAPE FINAL | 08/05/2024 | APPROVED | RPICATAGI |
| Note: 7/9/2024 2:05:09 PM- PREVIOUS INSPECTION NOTES 1. Excessive weeds in bed 2. Dead or dying plants - bird of paradise 3. Mulch is mixed with soil and does not offer proper cover, Irrigation pipe is exposed and not properly buried 4. Overall poor workmanship and poor attention to detail. 5. Not required but- owner should consider painting (white) vertical 2X4 behind center structure | |||
| ELECTRIC FINAL | 07/19/2024 | PARTIALLY APPROVED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 7/19/2024 3:34:35 PM *** Need to call back in when power is on to test all equipment 7/16/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/16/2024 1:22:11 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES 7/8/2024 - PREVIOUS INSPECTION NOTES 1st rough elec. inspection was not done | |||
| ELECTRIC 1ST ROUGH | 07/19/2024 | APPROVED | RMARTIN |
| Note: 7/16/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/16/2024 1:21:31 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/10/2024 10:50:22 AM *** MAY NEED CONTRACTOR OR REP. ON SITE TO VERIFY DEPTH OF CONDUIT PER NEC.300.5 TABLE AND PANEL CAN NOT BE ACCESSED DUE TO TREE BRACE 2X4 7/9/2024 - PREVIOUS INSPECTION NOTES Meter labeled 55 Not per plan - Has 4 gates, lights, outlet & intercom on legend (3 - 15A circuits) Please revise drawings. I think the permits were swapped. This is the main entry gate correct? | |||
| ELECTRIC FINAL | 07/16/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 7/16/2024 1:22:11 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES 7/8/2024 - PREVIOUS INSPECTION NOTES 1st rough elec. inspection was not done | |||
| ELECTRIC 1ST ROUGH | 07/16/2024 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 7/16/2024 1:21:31 PM *** NEED TOHAVE SITE STICKS FOR DEPTH, WE DO NOT ACCEPT PICTURES, BGOUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROTECTED AND ADDRESS ON METER CAN IS NOT THE CORRECT ADDRESS NEC 250.64, AND NEC 300.5 7/10/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/10/2024 10:50:22 AM *** MAY NEED CONTRACTOR OR REP. ON SITE TO VERIFY DEPTH OF CONDUIT PER NEC.300.5 TABLE AND PANEL CAN NOT BE ACCESSED DUE TO TREE BRACE 2X4 7/9/2024 - PREVIOUS INSPECTION NOTES Meter labeled 55 Not per plan - Has 4 gates, lights, outlet & intercom on legend (3 - 15A circuits) Please revise drawings. I think the permits were swapped. This is the main entry gate correct? | |||
| ELECTRIC 1ST ROUGH | 07/10/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 7/10/2024 10:50:22 AM *** MAY NEED CONTRACTOR OR REP. ON SITE TO VERIFY DEPTH OF CONDUIT PER NEC.300.5 TABLE AND PANEL CAN NOT BE ACCESSED DUE TO TREE BRACE 2X4 7/9/2024 - PREVIOUS INSPECTION NOTES Meter labeled 55 Not per plan - Has 4 gates, lights, outlet & intercom on legend (3 - 15A circuits) Please revise drawings. I think the permits were swapped. This is the main entry gate correct? | |||
| ELECTRIC 1ST ROUGH | 07/10/2024 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC FINAL | 07/10/2024 | CANCELLED BY APPLICANT | RMARTIN |
| Note: 7/8/2024 - PREVIOUS INSPECTION NOTES 1st rough elec. inspection was not done | |||
| ELECTRIC FINAL | 07/10/2024 | CANCELLED BY APPLICANT | WEB |
| FINAL | 07/10/2024 | CANCELLED BY APPLICANT | WEB |
| LDSC- LANDSCAPE FINAL | 07/10/2024 | CANCELLED BY APPLICANT | WEB |
| LDSC- LANDSCAPE FINAL | 07/09/2024 | Disapproved - NO FEE | RPICATAGI |
| Note: 1. Excessive weeds in bed 2. Dead or dying plants - bird of paradise 3. Mulch is mixed with soil and does not offer proper cover, Irrigation pipe is exposed and not properly buried 4. Overall poor workmanship and poor attention to detail. 5. Not required but- owner should consider painting (white) vertical 2X4 behind center structure | |||
| ELECTRIC 1ST ROUGH | 07/09/2024 | Disapproved - NO FEE | AWATERS |
| Note: Meter labeled 55 Not per plan - Has 4 gates, lights, outlet & intercom on legend (3 - 15A circuits) Please revise drawings. I think the permits were swapped. This is the main entry gate correct? | |||
| ELECTRIC FINAL | 07/08/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1st rough elec. inspection was not done | |||
| LDSC- LANDSCAPE FINAL | 07/08/2024 | CANCELLED BY APPLICANT | WEB |
| DOWN CELL | 01/16/2024 | APPROVED | FWILLIS |
| Note: 1/8/2024 - PREVIOUS INSPECTION NOTES CANNOT SEE REBAR INSIDE COLUMNS. APPEARS NOT TO HAVE REBAR LAPPED COMING OUT OF COLUMNS. ALSO, NEED TO SEE METAL POST WITH REBAR WELDED AT BOTTOM AS PER PLAN. | |||
| DOWN CELL | 01/08/2024 | Disapproved - NO FEE | FWILLIS |
| Note: CANNOT SEE REBAR INSIDE COLUMNS. APPEARS NOT TO HAVE REBAR LAPPED COMING OUT OF COLUMNS. ALSO, NEED TO SEE METAL POST WITH REBAR WELDED AT BOTTOM AS PER PLAN. | |||
| FOOTER | 01/03/2024 | APPROVED | FWILLIS |
| Note: 1/2/2024 - PREVIOUS INSPECTION NOTES 12/29/2023 - PREVIOUS INSPECTION NOTES 4"PVC pole missing as per plan. Spoke with Jose and corrections will be addressed. | |||
| FOOTER | 01/02/2024 | CANCELLED BY APPLICANT | FWILLIS |
| Note: 12/29/2023 - PREVIOUS INSPECTION NOTES 4"PVC pole missing as per plan. Spoke with Jose and corrections will be addressed. | |||
| FOOTER | 12/29/2023 | Disapproved - NO FEE | FWILLIS |
| Note: 4"PVC pole missing as per plan. Spoke with Jose and corrections will be addressed. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 07/15/2024 | 07/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/08/2024 | 07/08/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please resubmit under supporting documents (not landscape plan). Please be more descriptive the directions for these pictures and the intentions. We do not typically accept photos for inspections. If you were directed to do this, include this in your correction sheet details. You may upload altogether as one file, and name the file what the pictures are for. (example - photos of electric trench) | |||
| BLD | COMPLETE | 01/10/2024 | 01/12/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/12/2023 | 12/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 12/01/2023 | 12/04/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List electrical sub contractor. | |||
| BLD | COMPLETE | 12/01/2023 | 12/07/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLLA | COMPLETE | 12/01/2023 | 12/08/2023 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 10/31/2023 | 11/02/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/24/2023 | 11/06/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. A landing on the pull side of the gates measuring 60 inches in length (in the direction of forward approach) and extending 18 inches beyond the latch side of the gate is required. Re-draw showing dimensions. 2020 FBC-Accessibility Section 404.2.1, Table 404.2.1. 2. A landing on the push side of the gates measureing 48 inches in lenght (in the direction of foward approach) and extnding 12 inches beyond the latch side of the gate is required. Re-draw showing dimensions. 2020 FBC-Accessibility Section 404.2.1, Table 404.2.1. 3. Gates must have smooth surface to a point 10 inches above the ground on the push side of gates. 2020 FBC-Accessibility Section 404.2.10. Cavaties at the top of kick plates to recessed elements behind must be capped. 4. Provide gate latch detail or note on plans indicating latch to operate gates requires no grasping, pinching or turning of the wrist and is within the required reach ranges. List the reach ranges. FBC-Accessibility Section 308, 309. 5. Provide note on plans indicating gate in the open position not to extend beyond the face of the curb. Palm Coast Fire Department request is for full roadway width access without any obstruction into the roadway beyond the face of curb. | |||
| DSD | HOLD | 10/24/2023 | 10/24/2023 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Need to provide a letter from Town Center CDD that allow the proposed signs. Need to apply for a seperate permit for a Commercial Fence. Remove the plans that detail the fence and electrical mechanism for the gates. | |||
| ELEC | HOLD | 10/24/2023 | 11/02/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List electrical sub contractor. | |||
| PLLA | HOLD | 10/24/2023 | 11/06/2023 |
| Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM 1. Provide Landscape and Irrigation design 2. Provide paint colors, mfr & code # |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 07/23/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 07/05/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 12/12/2023 |
| SURCHARGE FS 533.721 | ¤4.74 | 12/12/2023 |
| SURCHARGE - FS 468.631 | ¤7.11 | 12/12/2023 |
| SW ENG REVIEW- 40 | ¤40.00 | 12/12/2023 |
| SITE PLAN 15 | ¤15.00 | 12/12/2023 |
| ADJUSTMENT 50% | (¤473.75) | 12/12/2023 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 12/12/2023 |
| INSPECTION COMMERCIAL | ¤840.00 | 12/12/2023 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 12/12/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤653.10 |