I want to search for...

Permit #2023101205

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00770-0110
CONDITIONED SPACE: 1243 sqft
GARAGE: 425 sqft
OPENED PORCH (WITH ROOF) : 31 sqft
Total Square Footage: 1699 sqft
Block: 00770
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 202-494-2019
Location Address: 15 RAMBLING LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/27/2023
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: INB FUND 2 LLC

Address

3670 MAGUIRE BOULEVARD SUITE 220

ORLANDO, FL 32803

Lot: 0110
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/23/2024 FINAL APPROVED AGAETANO
ROW - FINAL APRON (AFTER POUR) 07/23/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 07/23/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 07/23/2024 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 7/23/2024 8:26:47 AM *** water meter box not located Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:10:46 PM *** no irr-nocross connection
U -UTILITY RESIDENTIAL FINAL 07/23/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 7/23/2024 9:48:57 AM *** please if you see water meter box going to be low=trip hazard-then contact city to raise it at customer-service@palmcoastgov.com 7/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 7/23/2024 8:26:47 AM *** water meter box not located Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:10:46 PM *** no irr-nocross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/22/2024 APPROVED TPOLACEK
Note: 7/3/2024 - PREVIOUS INSPECTION NOTES 07/03/24 TPOLACEK*** SURVEY INDICATES BACK LEFT SIDE OF PROPERTY WILL NEGATIVELY IMPACT THE ADJOINING PROPERTY TO THE LEFT. IF THERE IS A DRAINAGE CONVEYANCE ALONG THE PROPERTY THAT WILL HOLD BACK THE WATER SURVEY MUST INDICATE SO. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) 18 Propose Drainage Pattern Sec 300.01c(5) Sec 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. 8 Rear yard will be drained Sec 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Flooding or draining onto adjacent properties will not be allowed.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/22/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- PROJECT STATUS 07/22/2024 APPROVED TPOLACEK
Note: FINAL SURVEY PASSED THERE IS NO NEED FOR PROJECT STATUS 1PM SITE MEET
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/03/2024 Disapproved - NO FEE TPOLACEK
Note: 07/03/24 TPOLACEK*** SURVEY INDICATES BACK LEFT SIDE OF PROPERTY WILL NEGATIVELY IMPACT THE ADJOINING PROPERTY TO THE LEFT. IF THERE IS A DRAINAGE CONVEYANCE ALONG THE PROPERTY THAT WILL HOLD BACK THE WATER SURVEY MUST INDICATE SO. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) 18 Propose Drainage Pattern Sec 300.01c(5) Sec 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. 8 Rear yard will be drained Sec 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Flooding or draining onto adjacent properties will not be allowed.
ROW- PRE-APRON (PRE-POUR) 05/31/2024 APPROVED TPOLACEK
Note: 05/31/24 TPOLACEK*** MET ISITE CONSTRUCTION AND THEY WERE IN PROCESS OF RESETTING PIPE. I WAITED FOR THEM TO COMPLETE THE JOB AND CULVERT IS WITHEN TOLERANCE THIS TIME. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/30/2024 - PREVIOUS INSPECTION NOTES THE CULVERT IS STILL OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan. ----------------------------------------------------------------------- 5/22/2024 - PREVIOUS INSPECTION NOTES 05/22/24 TPOLACEK*** CULVERT IS OUT OF TOLERANCE BY OVER THE .10 ALLOWANCE. i HAVE ALSO ATTACHED A COPY OF THE CULVERT DIAGRAM. PIPE SHOULD BE BURIED 1/2 WAY. YOUR PIPE IS NOT BURIED ENOUGH. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
U-CROSS CONNECTION 05/31/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:10:46 PM *** no irr-nocross connection
ROW- PRE-APRON (PRE-POUR) 05/30/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE CULVERT IS STILL OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan. ----------------------------------------------------------------------- 5/22/2024 - PREVIOUS INSPECTION NOTES 05/22/24 TPOLACEK*** CULVERT IS OUT OF TOLERANCE BY OVER THE .10 ALLOWANCE. i HAVE ALSO ATTACHED A COPY OF THE CULVERT DIAGRAM. PIPE SHOULD BE BURIED 1/2 WAY. YOUR PIPE IS NOT BURIED ENOUGH. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 05/22/2024 Disapproved - NO FEE TPOLACEK
Note: 05/22/24 TPOLACEK*** CULVERT IS OUT OF TOLERANCE BY OVER THE .10 ALLOWANCE. i HAVE ALSO ATTACHED A COPY OF THE CULVERT DIAGRAM. PIPE SHOULD BE BURIED 1/2 WAY. YOUR PIPE IS NOT BURIED ENOUGH. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
GRAVITY SEWER TEST 04/29/2024 APPROVED MGIBSON
SEWER TIE IN 04/29/2024 APPROVED MGIBSON
ELECTRIC - EARLY POWER 04/23/2024 APPROVED AGAETANO
PEP TANK INSTALLATION REQUEST 04/11/2024 APPROVED CBOWERMASTER
INSULATION 04/01/2024 APPROVED AGAETANO
Note: 3/27/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 03-22-2024 Dryer exhaust not complete and shield plates missing. Check at next inspection. 03-27-2024 Above issue not resolved. Dryer exhaust not complete and shield plates missing.
LATH/BRICK/ WATER BARRIER 03/28/2024 APPROVED AGAETANO
INSULATION 03/27/2024 Disapproved -FEE REQUIRED AGAETANO
Note: Inspector Notes from Inspection 2420 03-22-2024 Dryer exhaust not complete and shield plates missing. Check at next inspection. 03-27-2024 Above issue not resolved. Dryer exhaust not complete and shield plates missing.
ALL ROUGH 03/22/2024 APPROVED - AS NOTED AGAETANO
Note: 03-22-2024 Dryer exhaust not complete and shield plates missing. Check at next inspection.
ELECTRIC-TUG 03/08/2024 APPROVED RMARTIN
ROOF VALLEY & METAL 03/07/2024 APPROVED BTAYLOR
WALL SHEATHING 03/06/2024 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/06/2024 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 02/23/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/21/2024 APPROVED JWALKER
MONOLITHIC SLAB 02/12/2024 APPROVED JWALKER
Note: 2/9/2024 - PREVIOUS INSPECTION NOTES 1. Termite certification. Or intent to treat letter has not been posted in the job box. 2. The slab depth is to be a minimum of 4" See page S 0.0. Areas measuring as litte as 2 3/4. Remove excess soil and tamp slab. Reinstall test sting lines for the reispection. 3. Pex pipe sleve's need to protect the entire pipe. P-2603
MONOLITHIC SLAB 02/09/2024 Disapproved - NO FEE JWALKER
Note: 1. Termite certification. Or intent to treat letter has not been posted in the job box. 2. The slab depth is to be a minimum of 4" See page S 0.0. Areas measuring as litte as 2 3/4. Remove excess soil and tamp slab. Reinstall test sting lines for the reispection. 3. Pex pipe sleve's need to protect the entire pipe. P-2603
PLUMBING 1ST ROUGH UNDERGROUND 02/06/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/09/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
MECH COMPLETE 06/05/2024 06/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/22/2024 02/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/22/2024 02/22/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 HOLD 02/12/2024 02/12/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab.
ZON COMPLETE 02/12/2024 02/12/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/24/2024 01/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 12/19/2023 12/27/2023
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
BADMIN INFORMATION 12/19/2023 12/19/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process payment for permit. Stormwater has a hold that needs to be addressed before we are able to process payment. They put on hold and this should have been in apply stage. Please address Stormwater hold. Thank you!
ENGIN1 COMPLETE 12/19/2023 12/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/19/2023 12/19/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 11/17/2023 11/17/2023
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM FF elv to be revised and change to B drain
SW1 COMPLETE 11/08/2023 11/17/2023
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/08/2023 11/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/08/2023 11/08/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM no zoning changes only for stormwater
BLD COMPLETE 10/26/2023 10/27/2023
Note: Released By: JPI
CUSVC COMPLETE 10/26/2023 10/27/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/26/2023 10/31/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/26/2023 10/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 10/26/2023 10/30/2023
LOCATE COMPLETE 10/26/2023 10/31/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/26/2023 10/30/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 10/26/2023 11/08/2023
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please add drainage flow arrows
ZON COMPLETE 10/26/2023 10/27/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 10/26/2023 10/30/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 10/26/2023 12/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/23/2024
SW ENG REINSPECTION 20 ¤20.00 07/23/2024
SW ENG REINSPECTION 30 ¤30.00 07/01/2024
PLAN REVIEW - REVISION ¤32.50 07/01/2024
REINSPECTION RESIDENTIAL ¤40.00 07/01/2024
CONNECTION FEES ¤1,166.26 12/27/2023
FC IMPACT FEE EMS ¤62.00 12/27/2023
IMPACT FEE FIRE ¤428.09 12/27/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/27/2023
FC IMPACT FEE LIBRARY ¤268.00 12/27/2023
IMPACT FEE PARKS ¤1,800.99 12/27/2023
IMPACT FEE SCHOOL ¤5,450.00 12/27/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 12/27/2023
WATER -IRRIGATION INSPECTION ¤25.00 12/27/2023
SURCHARGE FS 533.721 ¤2.92 12/27/2023
SURCHARGE - FS 468.631 ¤4.38 12/27/2023
SW ENG - FOUNDATION SURVEY ¤20.00 12/27/2023
SW ENG INSPECTION 80 ¤80.00 12/27/2023
SW ENG PRE APRON ¤30.00 12/27/2023
WATER- TURN ON ¤25.00 12/27/2023
ADJUSTMENT 50% (¤292.11) 12/27/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/27/2023
INSPECTION - RESIDENTIAL ¤431.75 12/27/2023
PLAN REVIEW - RESIDENTIAL ¤122.46 12/27/2023
SW ENG - REVIEW 20 ¤20.00 12/27/2023
SW ENG RES REVIEW 200 ¤200.00 12/27/2023
SEWER CREDIT (¤1,147.00) 12/27/2023
SEWER INSPECTION ¤25.00 12/27/2023
SEWER CAPITAL FACILITY ¤5,344.38 12/27/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 12/27/2023
SITE PLAN 30 ¤30.00 12/27/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,243.50