I want to search for...

Permit #2023101429

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00270-0040
CONDITIONED SPACE: 1983 sqft
GARAGE: 516 sqft
OPENED PORCH (WITH ROOF) : 154 sqft
Total Square Footage: 2653 sqft
Block: 00270
Subdivision: -
Job Phone: 831-383-2883
Location Address: 27 SLOGANEER TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/05/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

PO BOX 770279

ORLANDO, FL 32877

Lot: 0040
Contracted Stated Job Value: ¤250,000.00
Job Description: Single Family Residence
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CFC1430061 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 09/17/2024 APPROVED FSLADISH
Note: 9/17/24 At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. Inspector Notes from Inspection 9272 9/16/24 PIPE ELEVATION IS GOOD. CUTS MADE. YOU HAVE A WASHOUT BEHIND RIGHT SIDE CULVERT END AND WHERE DRIVEWAY MEET. CULVERT IS FULL OF DIRT AND SILT AND WILL NEED TO BE COMPLETELY CLEANED OUT. THESE WILL NEED TO BE CORRECTED BEFORE ROW FINAL PASSAGE HOT PATCH COMPLETED. APPROVING AS NOTED THAT THESE AFTERPOUR ITEMS WILL NEE TO BE ADDRESSED. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 9/13/24 UPON WALKING PROPERTY DETERMINED THAT WHILE THE GROUND IS COMPLETLY STUATED FROM SEVERAL DAYS OF HAEVY RAIN THAT ACCORDING TO THE SURVEY ELEVATIONS AND VISUAL IN THE FIELD THE DRAINAGE SHOULD WORK AS INDICATED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. Inspector Notes from Inspection 9272 9/16/24 PIPE ELEVATION IS GOOD. CUTS MADE. YOU HAVE A WASHOUT BEHIND RIGHT SIDE CULVERT END AND WHERE DRIVEWAY MEET. CULVERT IS FULL OF DIRT AND SILT AND WILL NEED TO BE COMPLETELY CLEANED OUT. THESE WILL NEED TO BE CORRECTED BEFORE ROW FINAL PASSAGE HOT PATCH COMPLETED. APPROVING AS NOTED THAT THESE AFTERPOUR ITEMS WILL NEE TO BE ADDRESSED. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 9/13/24 UPON WALKING PROPERTY DETERMINED THAT WHILE THE GROUND IS COMPLETLY STUATED FROM SEVERAL DAYS OF HAEVY RAIN THAT ACCORDING TO THE SURVEY ELEVATIONS AND VISUAL IN THE FIELD THE DRAINAGE SHOULD WORK AS INDICATED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED.
U -UTILITY RESIDENTIAL FINAL 09/16/2024 FINAL APPROVED BWRIGHT
U-CROSS CONNECTION 09/16/2024 APPROVED - AS NOTED BWRIGHT
Note: IRR with potable water. PVB in place. No CC
ROW - FINAL APRON (AFTER POUR) 09/16/2024 APPROVED - AS NOTED FSLADISH
Note: 9/16/24 PIPE ELEVATION IS GOOD. CUTS MADE. YOU HAVE A WASHOUT BEHIND RIGHT SIDE CULVERT END AND WHERE DRIVEWAY MEET. CULVERT IS FULL OF DIRT AND SILT AND WILL NEED TO BE COMPLETELY CLEANED OUT. THESE WILL NEED TO BE CORRECTED BEFORE ROW FINAL PASSAGE HOT PATCH COMPLETED. APPROVING AS NOTED THAT THESE AFTERPOUR ITEMS WILL NEE TO BE ADDRESSED. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 9/13/24 UPON WALKING PROPERTY DETERMINED THAT WHILE THE GROUND IS COMPLETLY STUATED FROM SEVERAL DAYS OF HAEVY RAIN THAT ACCORDING TO THE SURVEY ELEVATIONS AND VISUAL IN THE FIELD THE DRAINAGE SHOULD WORK AS INDICATED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED.
BLD - BUILDING FINAL 09/16/2024 FINAL APPROVED BTAYLOR
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/13/2024 APPROVED FSLADISH
Note: 9/13/24 ELEVATION SHOTS REQUIRED HAVE BEEN ADDED AT THE TIME OF THIS INSPECTION. At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 YOU ARE REQUIRED TO HAVE PROPERTY LINE ELEVATION SHOTS EVERY 20 FT IN A GRID PATTERN. ON THE RIGHT SIDE YOU HAVE NONE, ON THE LEFT YOU ARE MISSING A FEW. PLEASE INDICATE IF CONSTRUCTION IS BLOCK OR WOOD. YOU ARE REQUIRED TO HAVE AN ELEVATION SHOT ON THE RIGHT FRONT CORNER OF THE STRUCTURE. THER IS ONLY 3 TENTHS OF FALL OFF THE REAR OF THE STRUCTURE. COPC STANDARDS CALL FOR 6" IN THE FIRST 10 FT. WE REQUIRE THE INVERT ELEVATIONS OF ANY CULVERT UP OR DOWNSTREAM WITHIN 100 FT OF PROPERTY LINES. THER IS NONE FOR THE RIGHT SIDE IMPROVED PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 7 Drainage structure within 100 ft must be shown Sec 300.01A8 "Sec 300.01A8 The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including, culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property." 1Bldg Code R401.3 Bldg Code R401.3 Lots shall be graded to drain surface water away from foundations walls. The grade shall fall a minimum of 6" (125 mm) within the first 10 ft (3048 mm) Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures
ROW FIELD SURVEY /GRADING CERTIFICATION 09/13/2024 APPROVED - AS NOTED FSLADISH
Note: 9/13/24 UPON WALKING PROPERTY DETERMINED THAT WHILE THE GROUND IS COMPLETLY STUATED FROM SEVERAL DAYS OF HAEVY RAIN THAT ACCORDING TO THE SURVEY ELEVATIONS AND VISUAL IN THE FIELD THE DRAINAGE SHOULD WORK AS INDICATED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/09/2024 Disapproved - NO FEE FSLADISH
Note: 9/9/24 YOU ARE REQUIRED TO HAVE PROPERTY LINE ELEVATION SHOTS EVERY 20 FT IN A GRID PATTERN. ON THE RIGHT SIDE YOU HAVE NONE, ON THE LEFT YOU ARE MISSING A FEW. PLEASE INDICATE IF CONSTRUCTION IS BLOCK OR WOOD. YOU ARE REQUIRED TO HAVE AN ELEVATION SHOT ON THE RIGHT FRONT CORNER OF THE STRUCTURE. THER IS ONLY 3 TENTHS OF FALL OFF THE REAR OF THE STRUCTURE. COPC STANDARDS CALL FOR 6" IN THE FIRST 10 FT. WE REQUIRE THE INVERT ELEVATIONS OF ANY CULVERT UP OR DOWNSTREAM WITHIN 100 FT OF PROPERTY LINES. THER IS NONE FOR THE RIGHT SIDE IMPROVED PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 7 Drainage structure within 100 ft must be shown Sec 300.01A8 "Sec 300.01A8 The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including, culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property." 1Bldg Code R401.3 Bldg Code R401.3 Lots shall be graded to drain surface water away from foundations walls. The grade shall fall a minimum of 6" (125 mm) within the first 10 ft (3048 mm) Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/05/2024 Disapproved - NO FEE FSLADISH
Note: 9/5/24 PLEASE PROVIDE THE FFE, CULVERT ELEVATIONS AND SWALE ELEVATION AT PROPERTY LINE ON IMPROVED LOT ON THE RIGHT. YOUR SURVEY IS SHOWING THE CULVERT PIPE YOU HAVE INSTALLED AS 12" STMP. WE REQUIRE 13' X 17" CMP OR 15" HDPE PIPE. Culvert not the right size. / 12 inch pipe nor pre approved. Swale Plan Details #1 Swale Plan Details #1. The driveway culvert is to be a 17x13 (15" diameter equivalent) helical corrugated metal pipe with mitered ends...Substitutes require prior approval by the City Stormwater Engineer. 7 Drainage structure within 100 ft must be shown Sec 300.01A8 "Sec 300.01A8 The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including, culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property." Inspector Notes from Inspection 9270 8/2/24 PIPE ELEVATION IS OK. READY TO POUR AT THE TIME OF THIS INSPECTION. WITH A POSSIBLE STORM IN THE FORECAST IT IS BUILERS RESPONSIBILITY TO MAKE SURE TO RECHECK ELEVATIONS BEFORE POURING. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/1/2024 - PREVIOUS INSPECTION NOTES 8/1/24 CA NNOT LOCATE BM IN THE ROAD EDGE. THERE IS TO MUCH DIRT DEBRIS AND I AM UNABE TO LOCATE IT. BUILDER PLEASE REESTABLISH WITH CLEARLY MARKED DISCIN ASPHALT. PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY. PLEASE CLEARLY MARK BM.
FLOOR / WALL PENETRATION 08/20/2024 APPROVED BTAYLOR
ELECTRIC - EARLY POWER 08/20/2024 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2200 6-13-24 1. Emailed FPL at 12:15. 8-20-24 1. Emailed FPL at 1:58.
GRAVITY SEWER TEST 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 08/02/2024 APPROVED - AS NOTED FSLADISH
Note: 8/2/24 PIPE ELEVATION IS OK. READY TO POUR AT THE TIME OF THIS INSPECTION. WITH A POSSIBLE STORM IN THE FORECAST IT IS BUILERS RESPONSIBILITY TO MAKE SURE TO RECHECK ELEVATIONS BEFORE POURING. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/1/2024 - PREVIOUS INSPECTION NOTES 8/1/24 CA NNOT LOCATE BM IN THE ROAD EDGE. THERE IS TO MUCH DIRT DEBRIS AND I AM UNABE TO LOCATE IT. BUILDER PLEASE REESTABLISH WITH CLEARLY MARKED DISCIN ASPHALT. PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY. PLEASE CLEARLY MARK BM.
ROW- PRE-APRON (PRE-POUR) 08/01/2024 Disapproved - NO FEE FSLADISH
Note: 8/1/24 CA NNOT LOCATE BM IN THE ROAD EDGE. THERE IS TO MUCH DIRT DEBRIS AND I AM UNABE TO LOCATE IT. BUILDER PLEASE REESTABLISH WITH CLEARLY MARKED DISCIN ASPHALT. PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY. PLEASE CLEARLY MARK BM.
PEP TANK INSTALLATION REQUEST 07/03/2024 APPROVED CBOWERMASTER
INSULATION 07/01/2024 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 06/25/2024 APPROVED BTAYLOR
ALL ROUGH 06/25/2024 APPROVED BTAYLOR
ROOF VALLEY & METAL 06/13/2024 APPROVED BTAYLOR
ELECTRIC-TUG 06/13/2024 APPROVED - AS NOTED BTAYLOR
Note: 6-13-24 1. Emailed FPL at 12:15.
WALL SHEATHING 06/12/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/12/2024 APPROVED BTAYLOR
FOUND SURVEY APPROVED (OFFICE) 06/11/2024 APPROVED TBAKER
TIE BEAM / LINTEL 06/03/2024 APPROVED BTAYLOR
Note: 5/31/2024 - PREVIOUS INSPECTION NOTES
TIE BEAM / LINTEL 05/31/2024 CANCELLED BY APPLICANT BTAYLOR
MONOLITHIC SLAB 05/22/2024 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 05/17/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 04/25/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BADMIN COMPLETE 09/16/2024 09/16/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN HOLD 08/28/2024 08/28/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT SUBCONTRACTORS ON PERMIT APPLICATION
BADMIN HOLD 08/28/2024 08/28/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM APP WITH SUBCONTRACTORS NOT ATTACHED
BLD COMPLETE 07/10/2024 07/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2024 07/10/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/10/2024 06/11/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/10/2024 06/10/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 05/03/2024 05/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/30/2024 05/03/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Heatload needs to be Daytona Beach
BLD COMPLETE 11/15/2023 11/15/2023
Note: Released By: JPI
BLD HOLD 10/31/2023 11/06/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 10/31/2023 11/01/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 10/31/2023 11/02/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/31/2023 10/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 10/31/2023 11/03/2023
LOCATE COMPLETE 10/31/2023 11/06/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/31/2023 11/03/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/31/2023 11/15/2023
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ZON COMPLETE 10/31/2023 11/02/2023
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN COMPLETE 10/31/2023 11/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 10/31/2023 12/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 09/17/2024
CONTRACTOR CHANGE ¤20.00 09/17/2024
PLAN REVIEW - REVISION ¤32.50 09/17/2024
CONNECTION FEES ¤1,166.26 01/05/2024
CONTRACTOR CHANGE ¤20.00 01/05/2024
CONTRACTOR CHANGE ¤20.00 01/05/2024
WATER-METER ¤505.39 01/05/2024
WATER- TURN ON ¤25.00 01/05/2024
WATER- TURN ON ¤25.00 01/05/2024
ADJUSTMENT 50% (¤456.25) 01/05/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/05/2024
INSPECTION - RESIDENTIAL ¤687.50 01/05/2024
PLAN REVIEW - RESIDENTIAL ¤195.00 01/05/2024
FC IMPACT FEE EMS ¤62.00 01/05/2024
IMPACT FEE FIRE ¤428.09 01/05/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/05/2024
FC IMPACT FEE LIBRARY ¤268.00 01/05/2024
IMPACT FEE PARKS ¤1,800.99 01/05/2024
IMPACT FEE SCHOOL ¤5,450.00 01/05/2024
IMPACT FEE TRANSPORTATION ¤1,812.00 01/05/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/05/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/05/2024
SURCHARGE FS 533.721 ¤4.56 01/05/2024
SURCHARGE - FS 468.631 ¤6.84 01/05/2024
SW ENG - FOUNDATION SURVEY ¤20.00 01/05/2024
SW ENG INSPECTION 80 ¤80.00 01/05/2024
SW ENG PRE APRON ¤30.00 01/05/2024
SW ENG - REVIEW 20 ¤20.00 01/05/2024
SW ENG RES REVIEW 200 ¤200.00 01/05/2024
SEWER CREDIT (¤1,466.00) 01/05/2024
SEWER INSPECTION ¤25.00 01/05/2024
SEWER CAPITAL FACILITY ¤5,344.82 01/05/2024
WATER CAPITAL FACILITY FEE ¤3,923.88 01/05/2024
SITE PLAN 30 ¤30.00 01/05/2024
Fees Total Due: ¤0.00 Total Paid: ¤20,598.58