Permit #2023110238

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00640-0040
GARAGE: 888 sqft
CONDITIONED SPACE: 2956 sqft
OPENED PORCH (WITH ROOF) : 270 sqft
Total Square Footage: 4114 sqft
Block: 00640
Subdivision: -
Job Phone: 386-237-5837
Location Address: 87 WHEATFIELD DR
Type: DU - DUPLEX
Issue Date: 01/05/2024
NOC: RECORDED
Applicant name: MARSEL GILMANSHIN
Owner: IOURI SINKEVITCH

Address

412 OCEAN VIEW AVENUE APT 5C

BROOKLYN, NY 11235

Lot: 0040
Contracted Stated Job Value: ¤495,000.00
Job Description: Duplex
Type: CN

Contractor

GILMANS DEVELOPMENT CORP
Status Location Address State License Number Phone
ACTIVE

4873 PALM COAST PARKWAY NW #4

PALM COAST, FL 32137

CBC1263180 (Exp: 08/31/2026) 386-237-5837

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
SERGEY A VORONIN
Status Location Address State License Number Phone
ACTIVE

7631 SEVERN

JACKSONVILLE, FL 32224

EC13011326 (Exp: 08/31/2026) 360-798-2819

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/13/2025 FINAL APPROVED MKRASKI
ROW - FINAL INSPECTION 03/12/2025 APPROVED TPOLACEK
Note: 03/12/25 TPOLACEK*** CORRECTION MADE TO SWALE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/11/2025 - PREVIOUS INSPECTION NOTES 03/11/25 TPOLACEK*** ALL CORRECTIONS EXCEPT THE LEFT SIDE SWALE ARE COMPLETED. SPOKE WITH BUILDER THEY ARE GOING TO SOD TODAY AND RESUBMIT INSPECTION FOR TOMORROW. Inspector Notes from Inspection 9465 03/10/25 TPOLACEK*** AFTER HEAVY RAIN THIS MORNING THERE IS A SMALL AMOUNT OF STANDING WATER IN BOTH REAR CORNERS. , IN BACK RIGHT WHERE DIRT WAS PUSHED INTO ADJOINING PROPERTY BEHING FENCE THIS MUST BE GRADED AND SEED AND STRAW, ENTIRE LEFT SIDE OF PROPERTY WHERE MACHINE MADE ENTRY AND BARE EARTH IS MUST BE SEEDED AND STRAW, LEFT SIDE SWALE MUST BE REPAIRED AND SODDED WITH BAHIA TO AS GOOD OR BETTER THAN BEFORE CONSTRUCTION. ALL MUST BE DONE BEFORE FINAL STORMWATER INSPECTION. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 03/10/25TPOLACEK*** ALTHOUGH A COMMON WAS PROPOSED NEIGHBOR ON RIGHT HAS SINCE INSTALLED A FENCE AND MADE COMMON IMPOSSIBLE. BUILDER HAS SMALL INSIDE SWALE THAT WILL WORK. SPOKE WITH BUILDER AND EXPLAINED SMALL SHRUB BY AC WILL NEED TO BE REMOVED OUT OF CONVEYENCE AND i WILL APPROVE THE FINAL SURVEY AS NOTED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
U -UTILITY RESIDENTIAL FINAL 03/11/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection
ROW - FINAL INSPECTION 03/11/2025 Disapproved - NO FEE TPOLACEK
Note: 03/11/25 TPOLACEK*** ALL CORRECTIONS EXCEPT THE LEFT SIDE SWALE ARE COMPLETED. SPOKE WITH BUILDER THEY ARE GOING TO SOD TODAY AND RESUBMIT INSPECTION FOR TOMORROW. Inspector Notes from Inspection 9465 03/10/25 TPOLACEK*** AFTER HEAVY RAIN THIS MORNING THERE IS A SMALL AMOUNT OF STANDING WATER IN BOTH REAR CORNERS. , IN BACK RIGHT WHERE DIRT WAS PUSHED INTO ADJOINING PROPERTY BEHING FENCE THIS MUST BE GRADED AND SEED AND STRAW, ENTIRE LEFT SIDE OF PROPERTY WHERE MACHINE MADE ENTRY AND BARE EARTH IS MUST BE SEEDED AND STRAW, LEFT SIDE SWALE MUST BE REPAIRED AND SODDED WITH BAHIA TO AS GOOD OR BETTER THAN BEFORE CONSTRUCTION. ALL MUST BE DONE BEFORE FINAL STORMWATER INSPECTION. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 03/10/25TPOLACEK*** ALTHOUGH A COMMON WAS PROPOSED NEIGHBOR ON RIGHT HAS SINCE INSTALLED A FENCE AND MADE COMMON IMPOSSIBLE. BUILDER HAS SMALL INSIDE SWALE THAT WILL WORK. SPOKE WITH BUILDER AND EXPLAINED SMALL SHRUB BY AC WILL NEED TO BE REMOVED OUT OF CONVEYENCE AND i WILL APPROVE THE FINAL SURVEY AS NOTED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW - FINAL APRON (AFTER POUR) 03/11/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 03/10/25 TPOLACEK*** AFTER HEAVY RAIN THIS MORNING THERE IS A SMALL AMOUNT OF STANDING WATER IN BOTH REAR CORNERS. , IN BACK RIGHT WHERE DIRT WAS PUSHED INTO ADJOINING PROPERTY BEHING FENCE THIS MUST BE GRADED AND SEED AND STRAW, ENTIRE LEFT SIDE OF PROPERTY WHERE MACHINE MADE ENTRY AND BARE EARTH IS MUST BE SEEDED AND STRAW, LEFT SIDE SWALE MUST BE REPAIRED AND SODDED WITH BAHIA TO AS GOOD OR BETTER THAN BEFORE CONSTRUCTION. ALL MUST BE DONE BEFORE FINAL STORMWATER INSPECTION. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 03/10/25TPOLACEK*** ALTHOUGH A COMMON WAS PROPOSED NEIGHBOR ON RIGHT HAS SINCE INSTALLED A FENCE AND MADE COMMON IMPOSSIBLE. BUILDER HAS SMALL INSIDE SWALE THAT WILL WORK. SPOKE WITH BUILDER AND EXPLAINED SMALL SHRUB BY AC WILL NEED TO BE REMOVED OUT OF CONVEYENCE AND i WILL APPROVE THE FINAL SURVEY AS NOTED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
BLD - BUILDING FINAL 03/11/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. ODU breakers are over sized FBC (A)107.4 2. E-cals onsite are missing Building Dept. stamp of approval FBC 107.3.1 3. All garage penitrations in walls and ceiling must be sealed FBC R302.6 4. Breaker lock for AHU not installed properly NEC 424.19 5. No heater sticker on AHU FBCR M1303.1 6. Remove all trash and extra building materials before final can be approved FBC 1501.4 7. Range is required to be GFCI protected NEC 210.8 8. Penisula missing outlet @ end NEC 210.52 9. Termite sticker not posted FBC R 319 10. Pep tanks require GFCI protection NEC 210.8 Not ready, stopped inspection
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/10/2025 APPROVED - AS NOTED TPOLACEK
Note: 03/10/25TPOLACEK*** ALTHOUGH A COMMON WAS PROPOSED NEIGHBOR ON RIGHT HAS SINCE INSTALLED A FENCE AND MADE COMMON IMPOSSIBLE. BUILDER HAS SMALL INSIDE SWALE THAT WILL WORK. SPOKE WITH BUILDER AND EXPLAINED SMALL SHRUB BY AC WILL NEED TO BE REMOVED OUT OF CONVEYENCE AND i WILL APPROVE THE FINAL SURVEY AS NOTED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/10/2025 APPROVED - AS NOTED TPOLACEK
Note: 03/10/25 TPOLACEK*** AFTER HEAVY RAIN THIS MORNING THERE IS A SMALL AMOUNT OF STANDING WATER IN BOTH REAR CORNERS. , IN BACK RIGHT WHERE DIRT WAS PUSHED INTO ADJOINING PROPERTY BEHING FENCE THIS MUST BE GRADED AND SEED AND STRAW, ENTIRE LEFT SIDE OF PROPERTY WHERE MACHINE MADE ENTRY AND BARE EARTH IS MUST BE SEEDED AND STRAW, LEFT SIDE SWALE MUST BE REPAIRED AND SODDED WITH BAHIA TO AS GOOD OR BETTER THAN BEFORE CONSTRUCTION. ALL MUST BE DONE BEFORE FINAL STORMWATER INSPECTION. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 03/10/25TPOLACEK*** ALTHOUGH A COMMON WAS PROPOSED NEIGHBOR ON RIGHT HAS SINCE INSTALLED A FENCE AND MADE COMMON IMPOSSIBLE. BUILDER HAS SMALL INSIDE SWALE THAT WILL WORK. SPOKE WITH BUILDER AND EXPLAINED SMALL SHRUB BY AC WILL NEED TO BE REMOVED OUT OF CONVEYENCE AND i WILL APPROVE THE FINAL SURVEY AS NOTED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
U-CROSS CONNECTION 03/10/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/04/2025 Disapproved - NO FEE EMADISON
Note: ** 03/04/25 BUIDERS SITE PLAN WAS PROPOSED AS A COMMON DRAINAGE CONVEYANCE ON THE RIGHT SIDE NEED TO REMOVE BERM AND BUILD AS PROPOSED. SEE THE LETTER BELOW THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS DATED APRIL 9, 2024. ***CONTRACTORS NEWSFLASH*** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ELECTRIC - EARLY POWER 02/11/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Per manufacturer specs SPD is to be installed on a 20a breaker Check at final Emailed FPL for power release @ 2pm
ROW- PRE-APRON (PRE-POUR) 01/15/2025 APPROVED - AS NOTED TPOLACEK
Note: 01/15/25 TPOLACEK*** WORKED WITH CREW TO ACCOMPLISH LESS THAN 8% SLOPE IN APRON. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/14/2025 - PREVIOUS INSPECTION NOTES 01/14/25 TPOLACEK** DRIVEWAY APRON EXCEEDS THE MAXIMUM ALLOWED 8% SLOPE. PLEASE RESET FORM BOARDS TO ACHIEVE LESS THAN 8% SLOPE. 1/13/2025 - PREVIOUS INSPECTION NOTES 01/13/25 TPOLACEK** SPOKE WITH CREW ON SITE. ROADSIDE FORM BOARD CAN NOT BE MORE THAN 2" OVER EXISTING EDGE OF ROAD, MITER END FORM BOARD NEED TO BE AT EDGE OF DRIVEWAY 18" TO SIDE OF PIPE AND AT FOOTER END 9" TO SIDE OF PIPE, THEY WILL REFORM AND CALL IN FOR NEW INSPECTION
ROW- PRE-APRON (PRE-POUR) 01/14/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 01/14/25 TPOLACEK** DRIVEWAY APRON EXCEEDS THE MAXIMUM ALLOWED 8% SLOPE. PLEASE RESET FORM BOARDS TO ACHIEVE LESS THAN 8% SLOPE. 1/13/2025 - PREVIOUS INSPECTION NOTES 01/13/25 TPOLACEK** SPOKE WITH CREW ON SITE. ROADSIDE FORM BOARD CAN NOT BE MORE THAN 2" OVER EXISTING EDGE OF ROAD, MITER END FORM BOARD NEED TO BE AT EDGE OF DRIVEWAY 18" TO SIDE OF PIPE AND AT FOOTER END 9" TO SIDE OF PIPE, THEY WILL REFORM AND CALL IN FOR NEW INSPECTION
ROW- PRE-APRON (PRE-POUR) 01/13/2025 Disapproved - NO FEE TPOLACEK
Note: 01/13/25 TPOLACEK** SPOKE WITH CREW ON SITE. ROADSIDE FORM BOARD CAN NOT BE MORE THAN 2" OVER EXISTING EDGE OF ROAD, MITER END FORM BOARD NEED TO BE AT EDGE OF DRIVEWAY 18" TO SIDE OF PIPE AND AT FOOTER END 9" TO SIDE OF PIPE, THEY WILL REFORM AND CALL IN FOR NEW INSPECTION
FIREWALL DRYWALL NAILING 12/30/2024 CANCELLED BY INSPECTOR MKRASKI
Note: Duplicate inspection
GRAVITY SEWER TEST 12/11/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 1. Porta-jon must be on site 2. Job box needs to be up facing the road with the address visible Make repaires before next inspection
SEWER TIE IN 12/11/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 1. Porta-jon must be on site 2. Job box needs to be up facing the road with the address visible Make repaires before next inspection
PEP TANK INSTALLATION REQUEST 11/20/2024 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 10/29/2024 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 10/28/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Silt fence must be kept in orginal condition FBC 3307.1 2. All exterior penitrations and hole in block require water barrier and lath FBC R402.4.1.1
FIREWALL FINAL 10/07/2024 APPROVED MKRASKI
FIREWALL DRYWALL NAILING 10/07/2024 CANCELLED BY APPLICANT WEB
FIREWALL FINAL 09/25/2024 Disapproved - NO FEE MKRASKI
Note: Not ready, call in once 5/8'' type X board has been installed on ceiling and 1/2'' on wall per plans
WINDOW NAILING 09/25/2024 APPROVED MKRASKI
Note:
INSULATION 09/24/2024 APPROVED - AS NOTED MKRASKI
Note: Added window nailing inspection for B side garage entry gap exceeds a 1/4''
INSULATION 09/23/2024 Disapproved - NO FEE MKRASKI
Note: 1. Previous items not reapired from all rough (window/door gaps exceed 1/4'') FBCR 609.1
FIREWALL DRYWALL NAILING 09/23/2024 APPROVED MKRASKI
FIREWALL DRYWALL NAILING 09/12/2024 Disapproved - NO FEE MKRASKI
Note: 9/12/24 1. Repair silt fence to original condition FBC 3307.1 2. Smoke barrier must extend to to of soffit ***Previous items not repaired*** 9/11/24 1. Windows and doors have to large of gaps around them, bucks required to fill gap FBCR 609.11/4'' max Check at insulation 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 Make ALL repairs before re-inspection 1. E-cals still do not match duct layout FBC [A]107.4 2. Address is not visible from road FBC 319.1 9/4/2024 - PREVIOUS INSPECTION NOTES 9/4/24 1. E-cals on site STILL do not match duct work that was installed, marked on E-cals 2. Silt fence shall be kept in orginal condition through out build FBC 3307.1 FBC [A]107.4 3. Address not visible from road per FBC 319.1 Make ALL repairs before calling in re-inspection 8/29/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection 08-29-2024 1. Framing not complete over doors. 2. Mechanical layout and energy calcs not on site.
ALL ROUGH 09/11/2024 APPROVED - AS NOTED MKRASKI
Note: 9/11/24 1. Windows and doors have to large of gaps around them, bucks required to fill gap FBCR 609.11/4'' max Check at insulation 9/9/2024 - PREVIOUS INSPECTION NOTES 9/9/24 Make ALL repairs before re-inspection 1. E-cals still do not match duct layout FBC [A]107.4 2. Address is not visible from road FBC 319.1 9/4/2024 - PREVIOUS INSPECTION NOTES 9/4/24 1. E-cals on site STILL do not match duct work that was installed, marked on E-cals 2. Silt fence shall be kept in orginal condition through out build FBC 3307.1 FBC [A]107.4 3. Address not visible from road per FBC 319.1 Make ALL repairs before calling in re-inspection 8/29/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection 08-29-2024 1. Framing not complete over doors. 2. Mechanical layout and energy calcs not on site.
ALL ROUGH 09/09/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 9/9/24 Make ALL repairs before re-inspection 1. E-cals still do not match duct layout FBC [A]107.4 2. Address is not visible from road FBC 319.1 9/4/2024 - PREVIOUS INSPECTION NOTES 9/4/24 1. E-cals on site STILL do not match duct work that was installed, marked on E-cals 2. Silt fence shall be kept in orginal condition through out build FBC 3307.1 FBC [A]107.4 3. Address not visible from road per FBC 319.1 Make ALL repairs before calling in re-inspection 8/29/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection 08-29-2024 1. Framing not complete over doors. 2. Mechanical layout and energy calcs not on site.
ALL ROUGH 09/04/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 9/4/24 1. E-cals on site STILL do not match duct work that was installed, marked on E-cals 2. Silt fence shall be kept in orginal condition through out build FBC 3307.1 FBC [A]107.4 3. Address not visible from road per FBC 319.1 Make ALL repairs before calling in re-inspection 8/29/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection 08-29-2024 1. Framing not complete over doors. 2. Mechanical layout and energy calcs not on site.
ALL ROUGH 08/29/2024 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2467 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection 08-29-2024 1. Framing not complete over doors. 2. Mechanical layout and energy calcs not on site.
ROOF VALLEY & METAL 04/01/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Repair silt fence to orginal condition 2. Clean up trash from site Check on next inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/27/2024 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/22/2024 Disapproved - NO FEE RSIMS
Note: 3/21/24: * You will still need a dumpster on site. Both Units: 1). 2 Ply trusses 01 are not connected as required. Highlighted on MiTek. 2). Trusses 02: are not strapped per the detail on plan page S2.1 (staggered each side). 3). Truss buckets attached to 01 truss need nails fully sunk. Check all brackets. Unit A: 4). 1st (2) - JG2 truss (just past garage back wall) - the replacement straps are covered on the bottom with foam board so we cannot visually inspect for proper anchoring. Unit B: 1st - JG2 truss (just past garage back wall on right) - the replacement straps are covered on the bottom with foam board so we cannot visually inspect for proper anchoring. 3/19/2024 - PREVIOUS INSPECTION NOTES 1. Must have clean set of plans bound together for inspector per FBC 107.3.1 2. Clean job box 3. Silt fence required around job site 4. No dumpster on site, Trash needs to be cleaned up and dumpster onsite Stopped inspection
WALL SHEATHING 03/22/2024 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/19/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Must have clean set of plans bound together for inspector per FBC 107.3.1 2. Clean job box 3. Silt fence required around job site 4. No dumpster on site, Trash needs to be cleaned up and dumpster onsite Stopped inspection
FOUND SURVEY APPROVED (OFFICE) 03/18/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/21/2024 APPROVED MKRASKI
TIE BEAM / LINTEL 02/20/2024 Disapproved - NO FEE MKRASKI
Note: No dowel layout on site stopped inspection, FBC 107.3.1
MONOLITHIC SLAB 02/07/2024 APPROVED RSIMS
Note: 2/6/2024 - PREVIOUS INSPECTION NOTES No ready contractor still on site installing rebar
MONOLITHIC SLAB 02/06/2024 Disapproved - NO FEE MKRASKI
Note: No ready contractor still on site installing rebar
PLUMBING 1ST ROUGH UNDERGROUND 01/26/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Porta-jon must be on site 2. Job box needs to be up facing the road with the address visible Make repaires before next inspection
WATER METER INSTALLATION REQUEST 01/26/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 03/15/2024 03/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/15/2024 03/15/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 11/21/2023 11/21/2023
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/21/2023 11/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/21/2023 11/30/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 11/21/2023 11/21/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
BLD COMPLETE 11/07/2023 11/08/2023
Note: Released By: JPI
CUSVC COMPLETE 11/07/2023 11/13/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 11/07/2023 11/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/07/2023 11/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/07/2023 11/07/2023
LOCATE COMPLETE 11/07/2023 11/13/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/07/2023 11/08/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/07/2023 11/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 11/07/2023 11/07/2023
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Survey / Site Plan wrong square footage.
BADMIN COMPLETE 11/07/2023 11/08/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 11/07/2023 01/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/13/2025
REINSPECTION RESIDENTIAL ¤40.00 03/13/2025
REINSPECTION RESIDENTIAL ¤40.00 03/13/2025
REINSPECTION RESIDENTIAL ¤40.00 03/13/2025
REINSPECTION RESIDENTIAL ¤40.00 03/13/2025
CONNECTION FEES ¤42.00 03/13/2025
CONTRACTOR CHANGE ¤20.00 03/13/2025
SW ENG REINSPECTION 30 ¤30.00 03/13/2025
SEWER CAPITAL FACILITY ¤192.42 03/13/2025
WATER CAPITAL FACILITY FEE ¤141.26 03/13/2025
SEWER CAPITAL FACILITY ¤10,689.64 01/05/2024
SW ENG RES REVIEW 200 ¤200.00 01/05/2024
SEWER CREDIT (¤1,806.00) 01/05/2024
SEWER INSPECTION ¤25.00 01/05/2024
SITE PLAN 30 ¤30.00 01/05/2024
WATER CAPITAL FACILITY FEE ¤7,847.76 01/05/2024
PLAN REVIEW - RESIDENTIAL ¤440.70 01/05/2024
ADJUSTMENT 50% (¤1,012.23) 01/05/2024
INSPECTION - RESIDENTIAL ¤1,553.75 01/05/2024
IMPACT FEE FIRE ¤856.18 01/05/2024
FC IMPACT FEE EMS ¤124.00 01/05/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 01/05/2024
WATER- TURN ON ¤50.00 01/05/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/05/2024
FC IMPACT FEE LIBRARY ¤536.00 01/05/2024
IMPACT FEE SCHOOL ¤10,900.00 01/05/2024
IMPACT FEE PARKS ¤3,600.18 01/05/2024
IMPACT FEE TRANSPORTATION ¤2,812.00 01/05/2024
WATER -IRRIGATION INSPECTION ¤50.00 01/05/2024
SURCHARGE FS 533.721 ¤10.12 01/05/2024
SURCHARGE - FS 468.631 ¤15.18 01/05/2024
SW ENG INSPECTION 80 ¤80.00 01/05/2024
SW ENG - FOUNDATION SURVEY ¤20.00 01/05/2024
CONNECTION FEES ¤2,332.52 01/05/2024
SW ENG PRE APRON ¤30.00 01/05/2024
SW ENG - REVIEW 20 ¤20.00 01/05/2024
SW ENG - REVIEW 20 ¤20.00 12/05/2023
SW ENG RES REVIEW 200 ¤200.00 12/05/2023
SW ENG RES REVIEW 200 (¤200.00) 12/05/2023
SW ENG INSPECTION 80 (¤80.00) 12/05/2023
SW ENG INSPECTION 80 ¤80.00 12/05/2023
SW ENG PRE APRON ¤30.00 12/05/2023
SW ENG PRE APRON (¤30.00) 12/05/2023
SURCHARGE - FS 468.631 ¤15.18 12/05/2023
SW ENG - FOUNDATION SURVEY ¤20.00 12/05/2023
SW ENG - FOUNDATION SURVEY (¤20.00) 12/05/2023
SURCHARGE - FS 468.631 (¤15.18) 12/05/2023
SURCHARGE FS 533.721 ¤10.12 12/05/2023
SURCHARGE FS 533.721 (¤10.12) 12/05/2023
WATER -IRRIGATION INSPECTION ¤50.00 12/05/2023
WATER -IRRIGATION INSPECTION (¤50.00) 12/05/2023
IMPACT FEE SCHOOL (¤10,900.00) 12/05/2023
IMPACT FEE SCHOOL ¤10,900.00 12/05/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 12/05/2023
IMPACT FEE TRANSPORTATION (¤2,812.00) 12/05/2023
FC IMPACT FEE LIBRARY ¤536.00 12/05/2023
IMPACT FEE PARKS ¤3,600.18 12/05/2023
IMPACT FEE PARKS (¤3,600.18) 12/05/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/05/2023
INSPECTION - RESIDENTIAL ¤1,553.75 12/05/2023
INSPECTION - RESIDENTIAL (¤1,553.75) 12/05/2023
ADJUSTMENT 50% (¤1,012.23) 12/05/2023
ADJUSTMENT 50% ¤1,012.23 12/05/2023
WATER- TURN ON ¤50.00 12/05/2023
WATER- TURN ON (¤50.00) 12/05/2023
CONNECTION FEES ¤2,332.52 12/05/2023
CONNECTION FEES (¤2,332.52) 12/05/2023
FC IMPACT FEE LIBRARY (¤536.00) 12/05/2023
IMPACT FEE FIRE (¤856.18) 12/05/2023
IMPACT FEE FIRE ¤856.18 12/05/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 12/05/2023
FC IMPACT FEE LAW ENFORCEMENT (¤436.00) 12/05/2023
PLAN REVIEW - RESIDENTIAL (¤440.70) 12/05/2023
ADMINISTRATIVE RESIDENTIAL (¤30.00) 12/05/2023
PLAN REVIEW - RESIDENTIAL ¤440.70 12/05/2023
FC IMPACT FEE EMS ¤124.00 12/05/2023
FC IMPACT FEE EMS (¤124.00) 12/05/2023
SITE PLAN 30 ¤30.00 12/05/2023
SEWER INSPECTION ¤25.00 12/05/2023
SEWER CREDIT (¤1,806.00) 12/05/2023
SEWER INSPECTION (¤25.00) 12/05/2023
SEWER CREDIT ¤1,806.00 12/05/2023
SW ENG - REVIEW 20 (¤20.00) 12/05/2023
SEWER CAPITAL FACILITY ¤10,689.64 12/05/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 12/05/2023
WATER CAPITAL FACILITY FEE (¤7,847.76) 12/05/2023
SITE PLAN 30 (¤30.00) 12/05/2023
SEWER CAPITAL FACILITY (¤10,689.64) 12/05/2023
Fees Total Due: ¤0.00 Total Paid: ¤40,496.48