Permit #2023110662

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7063-00530-0010
Block: 00530
Subdivision: -
Job Phone: 813-418-0830
Location Address: 67 ZAUN TR
Type: DR - DRIVEWAY
Issue Date: 12/08/2023
NOC: RECORDED
Applicant name: ELLA JOANN HEBBLEWHITE
Owner: LEWANDOWSKI JAMES

Address

67 ZAUN TRAIL

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤7,500.00
Job Description: Driveway
Type: CN

Contractor

A-TEAM EXTERIORS, INC
Status Location Address Mailing Address State License Number Phone
ACTIVE

3750 GUNN HWY

TAMPA, FL 33618

STE 103

TAMPA, FL 33618

CBC1254370 (Exp: 08/31/2026) 813-418-0830

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 04/30/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE --------------------------------------------------------------------------- 2/20/2024 - PREVIOUS INSPECTION NOTES 2/20/24 AS I NOTED ON MY LAST INSPECTION REPORT, SOD HAS TO BE LAID AND GRADED TO MATCH EXISTING GRADE ON ALL BARE AREAS. I WILL NOT FEE YOU, PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. PHOTO FOR REFERENCE. _________________________________________________________________________________________________________________________ 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24 CULVERTS WILL NEED TO BE CLEANED OUT OF DIRT AND CONCRETE OVERPOUR AND SOD WILL NEDD TO BE LAID ON BARE SPOTS AND GRADE MATCHED, BEFORE ROW FINAL INSPECTION WILL BE PASSED. PHOTO FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS ALREADY HERE TO DO THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS. ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
U -UTILITY RESIDENTIAL FINAL 04/30/2024 FINAL APPROVED JHARDING
ROW - FINAL INSPECTION 02/20/2024 Disapproved - NO FEE FSLADISH
Note: 2/20/24 AS I NOTED ON MY LAST INSPECTION REPORT, SOD HAS TO BE LAID AND GRADED TO MATCH EXISTING GRADE ON ALL BARE AREAS. I WILL NOT FEE YOU, PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. PHOTO FOR REFERENCE. _________________________________________________________________________________________________________________________ 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24 CULVERTS WILL NEED TO BE CLEANED OUT OF DIRT AND CONCRETE OVERPOUR AND SOD WILL NEDD TO BE LAID ON BARE SPOTS AND GRADE MATCHED, BEFORE ROW FINAL INSPECTION WILL BE PASSED. PHOTO FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS ALREADY HERE TO DO THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS. ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
ROW - FINAL APRON (AFTER POUR) 01/23/2024 APPROVED - AS NOTED FSLADISH
Note: 1/23/24 PIPE GOOD. CUTS MADE. APPROVING THIS AFTER POUR INSPECTION AS NOTED. CULVERTS WILL NEED TO BE CLEANED OUT OF DIRT AND CONCRETE OVERPOUR AND SOD WILL NEDD TO BE LAID ON BARE SPOTS AND GRADE MATCHED BEFORE ROW FINAL INSPECTION WILL BE PASSED. PHOTO FOR REFERENCE Inspector Notes from Inspection 9270 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment: 1/23/24 PIPE GOOD. CUTS MADE. APPROVING THIS AFTER POUR INSPECTION AS NOTED. CULVERTS WILL NEED TO BE CLEANED OUT OF DIRT AND CONCRETE OVERPOUR AND SOD WILL NEDD TO BE LAID ON BARE SPOTS AND GRADE MATCHED BEFORE ROW FINAL INSPECTION WILL BE PASSED. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
ROW - FINAL INSPECTION 01/23/2024 Disapproved - NO FEE FSLADISH
Note: 1/23/24 CULVERTS WILL NEED TO BE CLEANED OUT OF DIRT AND CONCRETE OVERPOUR AND SOD WILL NEDD TO BE LAID ON BARE SPOTS AND GRADE MATCHED, BEFORE ROW FINAL INSPECTION WILL BE PASSED. PHOTO FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS ALREADY HERE TO DO THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS. ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
ROW- PRE-APRON (PRE-POUR) 12/14/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/14/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 12/12/2023 12:21:42 PM- PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
ROW- PRE-APRON (PRE-POUR) 12/13/2023 Disapproved -FEE REQUIRED TPOLACEK
Note: 12/13/23 ** NOT READY TO POUR PIPE IS OUT OF TOLERENCE FORM BOARDS OUT OF TOLERENCE. CM WAS AGITATED WHEN INSPECTORS WERE EXPLAINING WHAT NEEDED TO BE DONE. INSPECTORS LEFT THE SITE AS TO AVOID CONFLICT. ALL CITY OF PALM COAST STANDARDS MUST BE MET BEFORE NEXT INSPECTION IS RERQUESTED. I HAVE ADDED A PHOTO OF THE TECH MANUAL FOR CULVERT PIPE MINUMUM STANDARDS. _______________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:
ROW- PRE-APRON (PRE-POUR) 12/12/2023 Disapproved -FEE REQUIRED TPOLACEK
Note: 12/12/23 ** SPOKE WITH HOMEOWNER AND BUILDER AND EXPLAINED THE CONCRETE ON MITERED ENDS NEEDS TO BE REMOVED, NEED TO HAVE FORM BOARD ALONG EDGE OF ROAD, PIPE IS EXPOSED 1/2 WAY WITH 12" ON EITHER SIDE, NEED TO HAVE 6" CONCRETE THROUGHOUT ROW 4" THE REST OF DRIVEWAY UP TO GARAGE. Culvert below driveway to be encased to half depth of theculvert and at least twelve (12) inches on each side (A)(B) Comment: ? Concrete Over Pipe: Concrete thickness over the top of the culvert shall be a minimum of five (5) inches, unless approved by the City. (A) Citation(s): Comment: A. Land Development Code Technical Manual, Drawing 300.E Section A-A B. Land Development Code Technical Manual, Drawing 300.E (6) C. Land Development Code Technical Manual, Drawing 300.E (9) D. Land Development Code Technical Manual, Drawing 300.E (14) Comment: A. Land Development Code Technical Manual, Drawing 300.E, Section A-A B. Land Development Code Technical Manual, Drawing 300.E, Section B-B ? Concrete Thickness: Driveway thickness on the ROW shall be either six (6) inches on firmly compacted subgrade of clear granular material or five (5) inches on three (3) inches of limerock or shell base. This concrete thickness can be reduced by one (1) inch by the additional of 6X6 mesh concrete reinforcing wire. (A) Citation(s): Citation(s): A. Land Development Code Technical Manual, Section 900.04 (A) Comment:

Review History

Department Status Date In Date Out
ZON COMPLETE 11/20/2023 11/20/2023
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/20/2023 11/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/15/2023 11/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 11/15/2023 11/17/2023
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON HOLD 11/15/2023 11/15/2023
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please provide type of material for driveway.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 30 ¤30.00 04/29/2024
SW ENG REINSPECTION 30 ¤30.00 04/29/2024
ADJUSTMENT 50% (¤15.00) 12/08/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/08/2023
SW ENG INSPECTION 40 ¤40.00 12/07/2023
SW ENG PRE APRON ¤30.00 12/07/2023
SW ENG RES REVIEW 200 ¤200.00 12/07/2023
SITE PLAN 15 ¤15.00 12/07/2023
Fees Total Due: ¤0.00 Total Paid: ¤360.00