I want to search for...

Permit #2023110699

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00480-0050
CONDITIONED SPACE: 1983 sqft
GARAGE: 516 sqft
OPENED PORCH (WITH ROOF) : 154 sqft
Total Square Footage: 2653 sqft
Block: 00480
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 831-383-2883
Location Address: 12 LANSING LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/12/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: AD HOMES & CONSULTING LLC

Address

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

Lot: 0050
Contracted Stated Job Value: ¤225,000.00
Job Description: Single Family Residence
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CFC1430061 (Exp: 08/31/2026) 407-404-4000
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/14/2024 FINAL APPROVED JSTEWART
Note: 8/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/13/2024 11:11:50 AM *** 1. Please install set screws and shear off at all hose bibb vaccum breakers. P2902.4 2. Please raise HW Condensation line min 6" from grade. 3. Please clear all debri/material from garage (excessive).
BLD - BUILDING FINAL 08/13/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/13/2024 11:11:50 AM *** 1. Please install set screws and shear off at all hose bibb vaccum breakers. P2902.4 2. Please raise HW Condensation line min 6" from grade. 3. Please clear all debri/material from garage (excessive).
ROW - STORMWATER FINAL 08/13/2024 APPROVED EMADISON
ROW - STORMWATER FINAL 08/02/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) STILL NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS FROM YOUR LOT AND ALONG PROPERTY LINE. 2) STILL NEED TO CLEAN ALL DIRT FROM THE CULVERT PIPE. -------------------------------------------------------- **07/31/24 CLEAN CULVERT ** TRASH AND CONSTRUCTION DEBRIS ACROSS REAR PROPERTY LINE
U -UTILITY RESIDENTIAL FINAL 08/02/2024 FINAL APPROVED DHANEY
Note: 8/1/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY DHANEY 8/1/2024 8:57:46 AM *** No electric power to Pep tank - Pep panel is wired in and on ?
U -UTILITY RESIDENTIAL FINAL 08/01/2024 Disapproved - NO FEE DHANEY
Note: *** NOTES ADDED BY DHANEY 8/1/2024 9:24:54 AM *** No Electric from house . *** NOTES ADDED BY DHANEY 8/1/2024 8:57:46 AM *** No electric power to Pep tank - Pep panel is wired in and on ?
ROW - FINAL APRON (AFTER POUR) 08/01/2024 APPROVED EMADISON
Note:
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/31/2024 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 07/31/2024 APPROVED - AS NOTED EMADISON
Note: **07/31/24 CLEAN CULVERT ** TRASH AND CONSTRUCTION DEBRIS ACROSS REAR PROPERTY LINE
ELECTRIC - EARLY POWER 07/22/2024 APPROVED JSTEWART
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 12:27:14 PM *** Please encase HW wires into a covered holding box. per NEC 110.27 Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 5/3/2024 12:07:33 PM *** 5/3/24- Authorize release of email to FPL @ 12:07p
ELECTRIC - EARLY POWER 07/18/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 7/18/2024 12:27:14 PM *** Please encase HW wires into a covered holding box. per NEC 110.27 Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 5/3/2024 12:07:33 PM *** 5/3/24- Authorize release of email to FPL @ 12:07p
U-CROSS CONNECTION 07/18/2024 APPROVED DHANEY
ROW- PRE-APRON (PRE-POUR) 07/02/2024 APPROVED - AS NOTED EMADISON
Note: ** 07/02/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
GRAVITY SEWER TEST 06/24/2024 APPROVED - AS NOTED MGIBSON
Note: this was a virtual inspection
SEWER TIE IN 06/24/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 06/05/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 5/29/2024 12:47:50 PM *** Please submit a revision of energy calcs and Product approval for windows installed...Dont match. will check at insulation.
PEP TANK INSTALLATION REQUEST 05/31/2024 APPROVED CBOWERMASTER
ALL ROUGH 05/29/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 5/29/2024 12:47:50 PM *** Please submit a revision of energy calcs and Product approval for windows installed...Dont match. will check at insulation.
LATH/BRICK/ WATER BARRIER 05/24/2024 APPROVED FWILLIS
ROOF VALLEY & METAL 05/15/2024 APPROVED KSANDOE
WALL SHEATHING 05/10/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/10/2024 APPROVED FWILLIS
Note: For your Reference, we do not give partial inspections on Residential.
ELECTRIC-TUG 05/03/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 5/3/2024 12:07:33 PM *** 5/3/24- Authorize release of email to FPL @ 12:07p
FOUND SURVEY APPROVED (OFFICE) 04/23/2024 APPROVED TBAKER
TIE BEAM / LINTEL 04/23/2024 APPROVED FWILLIS
MONOLITHIC SLAB 04/15/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 04/11/2024 APPROVED MGIBSON
Note: 4/10/2024 - PREVIOUS INSPECTION NOTES 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) NEED TO CHANGE PLUMBING SUB CONTRACTOR OF RECORD
PLUMBING 1ST ROUGH UNDERGROUND 04/10/2024 Disapproved - NO FEE LMILLER
Note: 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1)
WATER METER INSTALLATION REQUEST 02/22/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ZON COMPLETE 07/10/2024 07/10/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
BLD COMPLETE 06/10/2024 06/13/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide only numbers that have changed or highlight changes on Product approval worksheet
BLD HOLD 06/04/2024 06/10/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide only numbers that have changed or highlight changes on Product approval worksheet
MECH COMPLETE 05/06/2024 05/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/23/2024 04/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/23/2024 04/23/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 12/21/2023 01/02/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
ZON COMPLETE 12/21/2023 12/21/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 11/21/2023 11/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 11/16/2023 11/20/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 11/16/2023 11/17/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 11/16/2023 11/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/16/2023 11/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/16/2023 11/20/2023
LOCATE COMPLETE 11/16/2023 11/17/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/16/2023 11/20/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/16/2023 11/27/2023
Note: Held By: SINA VEDADI MOGHADAM - - SVEDADIMOGHADAM@PALMCOASTGOV.COM 1. The drainage from the structure must have a minimum slope of six inches for the first ten feet. Please include this information as well 2. Could you please clarify the location of the PEP tank lid, is it the "LID" on the site plan? 3. Could you please include the scale as well? I was not able to locate it.
ZON COMPLETE 11/16/2023 11/16/2023
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN COMPLETE 11/16/2023 11/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 11/16/2023 01/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 08/13/2024
CONTRACTOR CHANGE ¤20.00 08/13/2024
CONTRACTOR CHANGE ¤20.00 08/13/2024
SW ENG REINSPECTION 20 ¤20.00 08/13/2024
PLAN REVIEW - REVISION ¤32.50 08/13/2024
REINSPECTION RESIDENTIAL ¤40.00 08/13/2024
CONNECTION FEES ¤1,187.26 01/12/2024
WATER-METER ¤505.39 01/12/2024
WATER- TURN ON ¤25.00 01/12/2024
WATER- TURN ON ¤25.00 01/12/2024
ADJUSTMENT 50% (¤671.58) 01/12/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/12/2024
INSPECTION - RESIDENTIAL ¤1,023.00 01/12/2024
PLAN REVIEW - RESIDENTIAL ¤290.16 01/12/2024
SW ENG - REVIEW 20 ¤20.00 01/12/2024
SW ENG RES REVIEW 200 ¤200.00 01/12/2024
SEWER CREDIT (¤850.00) 01/12/2024
SEWER INSPECTION ¤25.00 01/12/2024
SEWER CAPITAL FACILITY ¤5,441.03 01/12/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 01/12/2024
SITE PLAN 30 ¤30.00 01/12/2024
CONTRACTOR CHANGE ¤20.00 01/12/2024
FC IMPACT FEE EMS ¤62.00 01/12/2024
IMPACT FEE FIRE ¤428.09 01/12/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/12/2024
FC IMPACT FEE LIBRARY ¤268.00 01/12/2024
IMPACT FEE PARKS ¤1,800.99 01/12/2024
IMPACT FEE SCHOOL ¤5,450.00 01/12/2024
IMPACT FEE TRANSPORTATION ¤1,812.00 01/12/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/12/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/12/2024
SURCHARGE FS 533.721 ¤6.72 01/12/2024
SURCHARGE - FS 468.631 ¤10.07 01/12/2024
SW ENG - FOUNDATION SURVEY ¤20.00 01/12/2024
SW ENG INSPECTION 80 ¤80.00 01/12/2024
SW ENG PRE APRON ¤30.00 01/12/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,683.14