I want to search for...

Permit #2023111063

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-5112-00000-0050
Block: 00000
Subdivision: 1164 - PINE LAKES INDUSTRIAL PARK
Job Phone: 386-795-3234
Location Address: 11 COMMERCE BLVD
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 08/01/2024
NOC: RECORDED
Applicant name: CHARLES ANDREW COLEMAN
Owner: PALM COAST INDUSTRIAL EQUITIES LLC

Address

24 CHURCH STREET

MONTCLAIR, NJ 07042

Address

ATTN SCOTT GLAUBERG

MONTCLAIR, NJ 07042

Lot: 0050
Contracted Stated Job Value: ¤1,500,000.00
Job Description: UNIT 1 COMBINE UNITS 1,2,3 INTO ONE TENANT SPACE.
Type: CN

Contractor

COLEMAN GOODEMOTE CONSTRUCTION COMPANY INC
Status Location Address State License Number Phone Fax
ACTIVE

619 N. BEACH ST.

DAYTONA BEACH, FL 32114

CGC057396 (Exp: 08/31/2026) 386-257-3570 386-253-6692

Sub Contractors

MICHAEL WAYNE LYNCH
Status Location Address Mailing Address State License Number Phone
ACTIVE

512 FENTRESS BLVD

DAYTONA BEACH, FL 32114

SUITE I

DAYTONA BEACH, FL 32114

EC13013629 (Exp: 08/31/2026) 386-529-4803
GARY S WELBORN
Status Location Address State License Number Phone Fax
ACTIVE

1709 North Nova Road

Holly Hill, 32117

CFC1426839 (Exp: 08/31/2026) (386) 257-1172 386-252-5979
SHAWN MICHAEL HISS
Status Location Address State License Number Phone
ACTIVE

1315 LPGA BLVD

HOLLY HILL, FL 32117

CAC1813585 (Exp: 08/31/2026) (386)672-8688

Inspection History

Type Request Date Result Inspector
BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS 05/14/2026 PARTIALLY APPROVED KSANDOE
Note: Pre pour south east parking lot exits and dust collector slab
ABOVE CEILING 05/04/2026 APPROVED - AS NOTED RMARTIN
Note: 5/4/26 All M.E.P met on site, need to schedule fire sprinkler rough inspection prior to closing celing. 1/23/26: Will check during above ceiling inspection. Plumbing: North side (south side) bathroom - Vent has a strap that needs to be raised one spot to straighten pipe and remove dip. Roof penetrations will be checked at above ceiling or Plumbing final.
ELECTRIC - EARLY POWER 04/27/2026 APPROVED - AS NOTED RMARTIN
Note: Released power to FPL, will need approved revision on all electrical riser/panel schedule changes by final inspection.
ELECTRIC OTHER 04/27/2026 CANCELLED BY INSPECTOR RMARTIN
HVAC ROUGH 03/24/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Remaining (2)Fresh Air ducts. 2. Fresh Air & Exhaust connected through the walls. 3. All exhaust ducts ran and seamed. 4. Fresh Air wrap done. (Marked on Plans) 3/5/2026 - PREVIOUS INSPECTION NOTES 1. 10 out of 12 Fresh Air ducts/seams looked. Ok to wrap. Marked on plans. 2. Still need to connect trought the wall. 3. Exhaust not done yet. 1/22/2026 - PREVIOUS INSPECTION NOTES 1. Contractor Added FD on Fire wall marked. 2. Looked at the remaining duct work to be insulated, and supply duct. 3. Contractor submitting revision for exhaust and fresh air outlets going out the side of the building instead of roof. Not done yet. 12/11/2025 - PREVIOUS INSPECTION NOTES 1. Looked at the ducts for seams and hanging in the office area, and in the factory side. See plans for Marked areas. 2. Looked at the installation of the fire dampers. Marked.
FIREWALL PENETRATIONS 03/19/2026 PARTIALLY APPROVED KSANDOE
Note: Stencils in place 12/23/2025 - PREVIOUS INSPECTION NOTES North wall. Fire dampers inspected north and south as well
HVAC ROUGH 03/05/2026 PARTIALLY APPROVED HCAMACHO
Note: 1. 10 out of 12 Fresh Air ducts/seams looked. Ok to wrap. Marked on plans. 2. Still need to connect trought the wall. 3. Exhaust not done yet. 1/22/2026 - PREVIOUS INSPECTION NOTES 1. Contractor Added FD on Fire wall marked. 2. Looked at the remaining duct work to be insulated, and supply duct. 3. Contractor submitting revision for exhaust and fresh air outlets going out the side of the building instead of roof. Not done yet. 12/11/2025 - PREVIOUS INSPECTION NOTES 1. Looked at the ducts for seams and hanging in the office area, and in the factory side. See plans for Marked areas. 2. Looked at the installation of the fire dampers. Marked.
FRAMING 02/19/2026 PARTIALLY APPROVED KSANDOE
Note: Doorways 1/23/2026 - PREVIOUS INSPECTION NOTES 12/12/2025 - PREVIOUS INSPECTION NOTES Non-rated partition wall. North end
INSULATION 02/19/2026 APPROVED KSANDOE
Note: 2/3/2026 - PREVIOUS INSPECTION NOTES 2 bathrooms at each end remain New inspection due to canceled inspection 1/30/2026 - PREVIOUS INSPECTION NOTES 1/23/2026 - PREVIOUS INSPECTION NOTES 12/19/2025 - PREVIOUS INSPECTION NOTES Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
INSULATION 02/03/2026 CANCELLED BY APPLICANT WEB
Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1/23/2026 - PREVIOUS INSPECTION NOTES 12/19/2025 - PREVIOUS INSPECTION NOTES Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
INSULATION 02/03/2026 PARTIALLY APPROVED KSANDOE
Note: 2 bathrooms at each end remain New inspection due to canceled inspection 1/30/2026 - PREVIOUS INSPECTION NOTES 1/23/2026 - PREVIOUS INSPECTION NOTES 12/19/2025 - PREVIOUS INSPECTION NOTES Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
INSULATION 01/30/2026 PARTIALLY APPROVED KSANDOE
Note: 1/23/2026 - PREVIOUS INSPECTION NOTES 12/19/2025 - PREVIOUS INSPECTION NOTES Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
FIREWALL DRYWALL NAILING 01/30/2026 PARTIALLY APPROVED KSANDOE
Note: 1/27/2026 - PREVIOUS INSPECTION NOTES 1/22/2026 - PREVIOUS INSPECTION NOTES One side garage door cover up
FIREWALL DRYWALL NAILING 01/27/2026 PARTIALLY APPROVED KSANDOE
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES One side garage door cover up
FIREWALL PENETRATIONS 01/27/2026 PARTIALLY APPROVED KSANDOE
INSULATION 01/23/2026 PARTIALLY APPROVED KSANDOE
Note: 12/19/2025 - PREVIOUS INSPECTION NOTES Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
PLUMBING 2ND ROUGH 01/23/2026 APPROVED RSIMS
Note: 1/23/26: Will check during above ceiling inspection. North side (south side) bathroom - Vent has a strap that needs to be raised one spot to straighten pipe and remove dip. Roof penetrations will be checked at above ceiling or Plumbing final. New inspection due to canceled inspection 12/31/2025 - PREVIOUS INSPECTION NOTES 12/31/25: Inspected South Side of Building (office areas) for in wall plumbing. Inspector Notes from Inspection 3070 *** NOTES ADDED BY RSIMS 12/30/2025 10:46:35 AM *** 12/29/25: Lift station inspected. A plan revision will need to be submitted for new Invert @ 37" BFF along with directional change of discharge piping and tie-in to main 3" sanitary drain. 12/23/2025 - PREVIOUS INSPECTION NOTES 12/23/25: Cancelled by Applicant at @ 1020. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
FRAMING 01/23/2026 PARTIALLY APPROVED KSANDOE
Note: 12/12/2025 - PREVIOUS INSPECTION NOTES Non-rated partition wall. North end
ELECTRIC 2ND ROUGH 01/22/2026 PARTIALLY APPROVED RMARTIN
Note: 1/22/25 offices and front rest rooms, walls good 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25 Marked on print remainder of walls to look at. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25 Office area fire wall 1/2 wall, contractor could not locate approved plans that were highlighted last inspection. Need to locate those plans and have on site for next inspection. 11/24/2025 - PREVIOUS INSPECTION NOTES Partial walls only marked on print.
HVAC ROUGH 01/22/2026 PARTIALLY APPROVED HCAMACHO
Note: 1. Contractor Added FD on Fire wall marked. 2. Looked at the remaining duct work to be insulated, and supply duct. 3. Contractor submitting revision for exhaust and fresh air outlets going out the side of the building instead of roof. Not done yet. 12/11/2025 - PREVIOUS INSPECTION NOTES 1. Looked at the ducts for seams and hanging in the office area, and in the factory side. See plans for Marked areas. 2. Looked at the installation of the fire dampers. Marked.
FIREWALL DRYWALL NAILING 01/22/2026 PARTIALLY APPROVED KSANDOE
Note: One side garage door cover up
FIREWALL FRAMING 01/22/2026 PARTIALLY APPROVED KSANDOE
Note: 11/24/2025 - PREVIOUS INSPECTION NOTES North side
ELECTRIC 2ND ROUGH 01/22/2026 APPROVED RMARTIN
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 1/22/25 offices and front rest rooms, walls good 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25 Marked on print remainder of walls to look at. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25 Office area fire wall 1/2 wall, contractor could not locate approved plans that were highlighted last inspection. Need to locate those plans and have on site for next inspection. 11/24/2025 - PREVIOUS INSPECTION NOTES Partial walls only marked on print.
FIREWALL NAILING 01/13/2026 APPROVED KSANDOE
Note: 1/6/2026 - PREVIOUS INSPECTION NOTES Call in when red board is ready 12/19/2025 - PREVIOUS INSPECTION NOTES South end, north side New inspection due to canceled inspection 12/10/2025 - PREVIOUS INSPECTION NOTES North wall 12/5/2025 - PREVIOUS INSPECTION NOTES 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
PLUMBING 2ND ROUGH 01/07/2026 CANCELLED BY APPLICANT WEB
Note: 12/31/2025 - PREVIOUS INSPECTION NOTES 12/31/25: Inspected South Side of Building (office areas) for in wall plumbing. Inspector Notes from Inspection 3070 *** NOTES ADDED BY RSIMS 12/30/2025 10:46:35 AM *** 12/29/25: Lift station inspected. A plan revision will need to be submitted for new Invert @ 37" BFF along with directional change of discharge piping and tie-in to main 3" sanitary drain. 12/23/2025 - PREVIOUS INSPECTION NOTES 12/23/25: Cancelled by Applicant at @ 1020. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
MONOLITHIC SLAB 01/07/2026 APPROVED KSANDOE
Note: 11/25/2025 - PREVIOUS INSPECTION NOTES North Wall
ELECTRIC 1ST ROUGH 01/05/2026 PARTIALLY APPROVED MKRASKI
Note: lift station conduit approved
FIREWALL NAILING 01/05/2026 PARTIALLY APPROVED KSANDOE
Note: Call in when red board is ready 12/19/2025 - PREVIOUS INSPECTION NOTES South end, north side New inspection due to canceled inspection 12/10/2025 - PREVIOUS INSPECTION NOTES North wall 12/5/2025 - PREVIOUS INSPECTION NOTES 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
PLUMBING 2ND ROUGH 12/31/2025 PARTIALLY APPROVED RSIMS
Note: 12/31/25: Inspected South Side of Building (office areas) for in wall plumbing. Inspector Notes from Inspection 3070 *** NOTES ADDED BY RSIMS 12/30/2025 10:46:35 AM *** 12/29/25: Lift station inspected. A plan revision will need to be submitted for new Invert @ 37" BFF along with directional change of discharge piping and tie-in to main 3" sanitary drain. 12/23/2025 - PREVIOUS INSPECTION NOTES 12/23/25: Cancelled by Applicant at @ 1020. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
PLUMBING 1ST ROUGH 12/30/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/30/2025 10:46:35 AM *** 12/29/25: Lift station inspected. A plan revision will need to be submitted for new Invert @ 37" BFF along with directional change of discharge piping and tie-in to main 3" sanitary drain. 12/23/2025 - PREVIOUS INSPECTION NOTES 12/23/25: Cancelled by Applicant at @ 1020. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
PLUMBING 1ST ROUGH 12/23/2025 CANCELLED BY APPLICANT RSIMS
Note: 12/23/25: Cancelled by Applicant at @ 1020. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
FIREWALL FINAL 12/23/2025 PARTIALLY APPROVED KSANDOE
FIREWALL PENETRATIONS 12/23/2025 PARTIALLY APPROVED KSANDOE
Note: North wall. Fire dampers inspected north and south as well
FIREWALL NAILING 12/19/2025 CANCELLED BY APPLICANT WEB
Note: 12/10/2025 - PREVIOUS INSPECTION NOTES North wall 12/5/2025 - PREVIOUS INSPECTION NOTES 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
FIREWALL NAILING 12/19/2025 PARTIALLY APPROVED KSANDOE
Note: South end, north side New inspection due to canceled inspection 12/10/2025 - PREVIOUS INSPECTION NOTES North wall 12/5/2025 - PREVIOUS INSPECTION NOTES 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
INSULATION 12/19/2025 PARTIALLY APPROVED KSANDOE
Note: Pending plumbing 12/8/2025 - PREVIOUS INSPECTION NOTES SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
FRAMING 12/12/2025 PARTIALLY APPROVED KSANDOE
Note: Non-rated partition wall. North end
ELECTRIC 2ND ROUGH 12/11/2025 PARTIALLY APPROVED RMARTIN
Note: 12/11/25 Marked on print remainder of walls to look at. 12/10/2025 - PREVIOUS INSPECTION NOTES 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25 Office area fire wall 1/2 wall, contractor could not locate approved plans that were highlighted last inspection. Need to locate those plans and have on site for next inspection. 11/24/2025 - PREVIOUS INSPECTION NOTES Partial walls only marked on print.
HVAC ROUGH 12/11/2025 PARTIALLY APPROVED HCAMACHO
Note: 1. Looked at the ducts for seams and hanging in the office area, and in the factory side. See plans for Marked areas. 2. Looked at the installation of the fire dampers. Marked.
PLUMBING 1ST ROUGH 12/10/2025 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/10/2025 1:54:28 PM *** 12/10/25: This is a partial inspection for water supplies and sanitary drain to be installedup to and into ceiling space for all fixtures on the North end of the building to allow drywall to be installed on framed walls, etc. This does not include the proposed tank and SE pump. THIS PARTIAL APPROVAL IS ALSO PENDING CITY APPROVAL OF THE MULTIPLE REVISIONS THAT WERE SUBMITTED. 11/10/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
ELECTRIC 2ND ROUGH 12/10/2025 CANCELLED BY APPLICANT MKRASKI
Note: 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25 Office area fire wall 1/2 wall, contractor could not locate approved plans that were highlighted last inspection. Need to locate those plans and have on site for next inspection. 11/24/2025 - PREVIOUS INSPECTION NOTES Partial walls only marked on print.
FIREWALL NAILING 12/10/2025 PARTIALLY APPROVED KSANDOE
Note: North wall 12/5/2025 - PREVIOUS INSPECTION NOTES 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
INSULATION 12/08/2025 PARTIALLY APPROVED KSANDOE
Note: SE to the corner 11/26/2025 - PREVIOUS INSPECTION NOTES North wall
FIREWALL NAILING 12/05/2025 PARTIALLY APPROVED KSANDOE
Note: 12/3/2025 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
ELECTRIC 2ND ROUGH 12/05/2025 PARTIALLY APPROVED RMARTIN
Note: 12/5/25 Office area fire wall 1/2 wall, contractor could not locate approved plans that were highlighted last inspection. Need to locate those plans and have on site for next inspection. 11/24/2025 - PREVIOUS INSPECTION NOTES Partial walls only marked on print.
ELECTRIC 1ST ROUGH 12/05/2025 CANCELLED BY APPLICANT WEB
FIREWALL NAILING 12/03/2025 PARTIALLY APPROVED KSANDOE
Note: 11/24/2025 - PREVIOUS INSPECTION NOTES North side, first layer, one side
INSULATION 11/26/2025 PARTIALLY APPROVED KSANDOE
Note: North wall
MONOLITHIC SLAB 11/25/2025 PARTIALLY APPROVED KSANDOE
Note: North Wall
ELECTRIC 2ND ROUGH 11/24/2025 PARTIALLY APPROVED RMARTIN
Note: Partial walls only marked on print.
ELECTRIC 1ST ROUGH 11/24/2025 APPROVED - AS NOTED RMARTIN
Note: Underground and some walls marked on print
FIREWALL FRAMING 11/24/2025 PARTIALLY APPROVED KSANDOE
Note: North side
FIREWALL NAILING 11/24/2025 PARTIALLY APPROVED KSANDOE
Note: North side, first layer, one side
PLUMBING 1ST ROUGH 11/10/2025 PARTIALLY APPROVED MGIBSON
Note: THIS WAS FOR AREA ON OUTSIDE OF BATHROOM GROUP ON NORTH SIDE OF BUILDING WHERE PROPOSED TANK IS GOING TO BE 11/3/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
PLUMBING 1ST ROUGH 11/03/2025 PARTIALLY APPROVED MGIBSON
Note: THIS WAS FOR BACK BATHROOMS 10/29/2025 - PREVIOUS INSPECTION NOTES THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
MONOLITHIC SLAB 11/03/2025 APPROVED FWILLIS
Note: 11/3/25 - INSPECTED SOUTH END MONO INSPECTION. New inspection due to canceled inspection 10/23/2025 - PREVIOUS INSPECTION NOTES UNIT #1 PARTIAL, NORTH SIDE.
PLUMBING 1ST ROUGH 10/29/2025 PARTIALLY APPROVED MGIBSON
Note: THIS WAS FOR THE FRONT OF BUILDING WITH BACK TO BACK BATHROOMS , L/T AT FAR EAST SIDE OF BUILDING
MONOLITHIC SLAB 10/24/2025 CANCELLED BY APPLICANT WEB
Note: 10/23/2025 - PREVIOUS INSPECTION NOTES UNIT #1 PARTIAL, NORTH SIDE.
MONOLITHIC SLAB 10/23/2025 PARTIALLY APPROVED FWILLIS
Note: UNIT #1 PARTIAL, NORTH SIDE.
PLUMBING 1ST ROUGH 10/20/2025 PARTIALLY APPROVED MGIBSON
Note: THIS WAS FOR NORTH SIDE OF ''OL PALMCOAST DATA'' ADDRESS IS CONFUSING. DWV ONL
BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS
Note: 5/14/2026 - PREVIOUS INSPECTION NOTES Pre pour south east parking lot exits and dust collector slab
HVAC FINAL
PLUMBING FINAL
Note: 12/29/25: Lift station inspected. A plan revision will need to be submitted for new Invert @ 37" BFF along with directional change of discharge piping and tie-in to main 3" sanitary drain. 1/23/26: Will check during above ceiling inspection. Plumbing: North side (south side) bathroom - Vent has a strap that needs to be raised one spot to straighten pipe and remove dip. Roof penetrations will be checked at above ceiling or Plumbing final.
ELECTRIC FINAL
ELECTRIC 1ST ROUGH
Note: 1/6/2026 - PREVIOUS INSPECTION NOTES lift station conduit approved
FIREWALL DRYWALL NAILING
Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1/27/2026 - PREVIOUS INSPECTION NOTES 1/22/2026 - PREVIOUS INSPECTION NOTES One side garage door cover up
FIREWALL PENETRATIONS
Note: 1/27/2026 - PREVIOUS INSPECTION NOTES
FIREWALL PENETRATIONS
Note: 3/19/2026 - PREVIOUS INSPECTION NOTES Stencils in place 12/23/2025 - PREVIOUS INSPECTION NOTES North wall. Fire dampers inspected north and south as well
FIREWALL FINAL
Note: 12/23/2025 - PREVIOUS INSPECTION NOTES
FIREWALL FRAMING
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 11/24/2025 - PREVIOUS INSPECTION NOTES North side
FRAMING
Note: 2/19/2026 - PREVIOUS INSPECTION NOTES Doorways 1/23/2026 - PREVIOUS INSPECTION NOTES 12/12/2025 - PREVIOUS INSPECTION NOTES Non-rated partition wall. North end
BUILDING FINAL
FIRE FINAL
U - UTILITY COMMERCIAL FINAL

Review History

Department Status Date In Date Out
ELEC COMPLETE 05/11/2026 05/12/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH CANCEL 05/11/2026 05/12/2026
BLD COMPLETE 05/11/2026 05/12/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/09/2026 03/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 03/09/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 03/09/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 03/09/2026 03/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 03/09/2026 03/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/26/2026 02/27/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM COMPLETE 12/15/2025 12/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/25/2025 12/09/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 11/25/2025 12/04/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 11/25/2025 12/04/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/25/2025 12/09/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 11/25/2025 12/09/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Provide location of required check valve and fullopen valve on plans 712.2 FBC Plumbing THIS WAS A PREVIOUS COMMENT THAT WAS NOT ANSWERED IN PLAN REVIEW. PLEASE PROVIDE SO I CAN RELEASE THE PLUMBING INSPECTION HOLD. 1. Add backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, hot water dispenser, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee/tea maker with direct water supply connection).
MECH COMPLETE 07/30/2025 08/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/30/2025 08/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 07/30/2025 08/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 06/30/2025 07/08/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Revise occupant load maximum floor area for F1 occupancy. Table 1004.5 shows 100sqft per person. Also change number of occupants in code analysis. 1004/Table1004.5 FBC Building 2023
DSD COMPLETE 06/30/2025 07/03/2025
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
ELEC COMPLETE 06/30/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 06/30/2025 07/08/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-MECHANICAL (FBCM), FLORIDA BUILDING CODE-ENERGY CONSERVATION (FBCEC), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Design location on energy calcs has to be daytona beach or st. augustine. (not ocala). AHJ 2. Provide detail on plans and manufacturers specs on fire dampers per 607.3.1 FBC Mechanical 2023
PLUM HOLD 06/30/2025 07/08/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Add backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, hot water dispenser, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee/tea maker with direct water supply connection). 2. Provide note to indicate all backflow devices are subject to testing by an independent, third party, Florida licensed backflow testing agency and each backflow device will be tested and provided with an approved testing tag at time of installation. 312.10.2
UD1 COMPLETE 06/30/2025 07/03/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
FI1 COMPLETE 06/30/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/18/2024 01/30/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 01/05/2024 01/18/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Ok Repeat comment: 2. Provide note on plans for systems commissioning per C408.2 FBC Energy Conservation 2020 7Th edition Repeat Comment: 3. Provide note on plans stating documentation requirements per C408.2.5 Energy Conservation 2020 7Th edition 4. Ok
BLD COMPLETE 11/30/2023 12/12/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
DSD COMPLETE 11/30/2023 12/01/2023
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
ELEC COMPLETE 11/30/2023 12/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 11/30/2023 12/12/2023
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
MECH HOLD 11/30/2023 12/07/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 2. Provide note on plans for systems commissioning per C408.2 FBC Energy Conservation 2020 7Th edition 3. Provide note on plans stating documentation requirements per C408.2.5 Energy Conservation 2020 7Th edition 4. Plan sheet M300 Note #2. Revise to say the smoke detectors shall set off alarm indicating appliances a supervisory signal and activating a visable and audible signal inside the area per AHJ
PLUM COMPLETE 11/30/2023 12/12/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
UD1 COMPLETE 11/30/2023 12/12/2023
Note: Released By: ALEXANDER BLAKE - - ABLAKE@PALMCOASTGOV.COM
DSD HOLD 11/28/2023 11/28/2023
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Provide a layout plan to show all 3 units with connections and opening labeling each unit. What is the new purposed business occupying this space?

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤65.00 03/19/2026
PLAN REVIEW - REVISION ¤65.00 12/18/2025
CONTRACTOR CHANGE ¤20.00 09/11/2025
ADMINISTRATIVE - EXTENSION ¤40.00 08/04/2025
PLAN REVIEW - REVISION ¤130.00 08/04/2025
PLAN REVIEW - REVISION ¤130.00 08/04/2025
PLAN REVIEW - REVISION ¤130.00 08/04/2025
PLAN REVIEW - REVISION ¤130.00 08/04/2025
PLAN REVIEW - REVISION ¤130.00 08/04/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 08/01/2024
INSPECTION COMMERCIAL ¤10,500.00 08/01/2024
PLAN REVIEW - COMMERCIAL ¤1,725.00 08/01/2024
SURCHARGE FS 533.721 ¤61.50 08/01/2024
SURCHARGE - FS 468.631 ¤92.25 08/01/2024
SITE PLAN 30 ¤30.00 08/01/2024
ADJUSTMENT 50% (¤6,150.00) 08/01/2024
CONTRACTOR CHANGE ¤20.00 08/01/2024
Fees Total Due: ¤0.00 Total Paid: ¤7,193.75