Permit #2023111147

Permit Details

Status: COED

Parcel Id: 07-11-31-7011-00080-0250
CONDITIONED SPACE: 1801 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 18 sqft
OPENED PORCH (WITH ROOF) : 70 sqft
Total Square Footage: 2299 sqft
Block: 00080
Subdivision: 2193 - SECTION 11-BELLE TERRE
Job Phone: 202-494-2019
Location Address: 11 BECKNER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/09/2024
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: INB FUND 2 LLC

Address

11 BECKNER LANE

PALM COAST , FL 32137

Lot: 0250
Contracted Stated Job Value: ¤220,000.00
Job Description: Single Family Residence
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/04/2024 FINAL APPROVED MCONTRYMAN
U -UTILITY RESIDENTIAL FINAL 10/04/2024 FINAL APPROVED DHANEY
Note: 10/2/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY DHANEY 10/2/2024 7:38:02 AM *** Top of sewer clean out is broke - needs repaired .
ROW - STORMWATER FINAL 10/02/2024 APPROVED TPOLACEK
Note: STRAW IS IN PLACE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 ** 09/30/24 LEFT REAR CORNER NEEDS SEED AND STRAW ON BARE EARTH (VACANT LOT) ** CLEAN CULVERT
U -UTILITY RESIDENTIAL FINAL 10/02/2024 Disapproved - NO FEE DHANEY
Note: *** NOTES ADDED BY DHANEY 10/2/2024 7:38:02 AM *** Top of sewer clean out is broke - needs repaired .
ROW - FINAL APRON (AFTER POUR) 10/02/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 ** 09/30/24 LEFT REAR CORNER NEEDS SEED AND STRAW ON BARE EARTH (VACANT LOT) ** CLEAN CULVERT
U-CROSS CONNECTION 10/01/2024 APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/30/2024 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 09/30/2024 APPROVED - AS NOTED EMADISON
Note: ** 09/30/24 LEFT REAR CORNER NEEDS SEED AND STRAW ON BARE EARTH (VACANT LOT) ** CLEAN CULVERT
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/27/2024 Disapproved - NO FEE TPOLACEK
Note: 09/.27/24 TPOLACEK*** FINAL SURVEY INDICATES CULVERT IS OUT OF TOLERENCE BY ALMOST 1' PLEASE MAKE CORRECTION. ON THE RIGHT SIDE OF STRUCTURE 1/2 WAY TO THE REAR THE ELEVATION IS 24.75 THE NEXT ELEVATION SHOT IS THE PROPERTY LINE AT 24.75. THIS INDICATES FLAT AND YOU ARE REQUIRED TO HAVE 6" FALL OFF THE STRUCTURE IN THE FIRST 10'. IF THERE IS A DRSAINAGE CONVEYANCE BETWEEN THESE TWO SHOTS YOU ARE REQUIRED TO CAPTURE IT. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ 3. The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern.
ROW- PRE-APRON (PRE-POUR) 08/28/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------------- 8/23/2024 11:40:55 AM- PREVIOUS INSPECTION NOTES ** 08/23/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA ** MATERIAL AROUND CUVERT IS TOO SOFT FOOT SINKS 4 INCHES HOLE FILLS WITH WATER ** CULVERT NEEDS TO BE BURIED 1/2 UP _________________________________________________________________________________________________________________ 8/22/2024 - PREVIOUS INSPECTION NOTES ** 08/22/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA _________________________________________________________________________________________________________________ 8/21/2024 - PREVIOUS INSPECTION NOTES 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ROW- PRE-APRON (PRE-POUR) 08/28/2024 APPROVED PFLANAGAN
Note: New inspection due to canceled inspection 8/23/2024 - PREVIOUS INSPECTION NOTES ** 08/23/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA ** MATERIAL AROUND CUVERT IS TOO SOFT FOOT SINKS 4 INCHES HOLE FILLS WITH WATER ** CULVERT NEEDS TO BE BURIED 1/2 UP _________________________________________________________________________________________________________________ 8/22/2024 - PREVIOUS INSPECTION NOTES ** 08/22/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA _________________________________________________________________________________________________________________ 8/21/2024 - PREVIOUS INSPECTION NOTES 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ROW- PRE-APRON (PRE-POUR) 08/27/2024 CANCELLED BY APPLICANT WEB
Note: 8/23/2024 - PREVIOUS INSPECTION NOTES ** 08/23/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA ** MATERIAL AROUND CUVERT IS TOO SOFT FOOT SINKS 4 INCHES HOLE FILLS WITH WATER ** CULVERT NEEDS TO BE BURIED 1/2 UP _________________________________________________________________________________________________________________ 8/22/2024 - PREVIOUS INSPECTION NOTES ** 08/22/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA _________________________________________________________________________________________________________________ 8/21/2024 - PREVIOUS INSPECTION NOTES 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ROW- PRE-APRON (PRE-POUR) 08/23/2024 CANCELLED BY APPLICANT EMADISON
Note: ** 08/23/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA ** MATERIAL AROUND CUVERT IS TOO SOFT FOOT SINKS 4 INCHES HOLE FILLS WITH WATER ** CULVERT NEEDS TO BE BURIED 1/2 UP _________________________________________________________________________________________________________________ 8/22/2024 - PREVIOUS INSPECTION NOTES ** 08/22/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA _________________________________________________________________________________________________________________ 8/21/2024 - PREVIOUS INSPECTION NOTES 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ROW- PRE-APRON (PRE-POUR) 08/22/2024 Disapproved -FEE REQUIRED EMADISON
Note: ** 08/22/24 CULVERT PIPE IS OUT OF TOLERANCE PITCHED IN THE WRONG DIRECTION WATER FLOWS FROM THE LEFT TO RIGHT. ** LEFT SIDE FOOTER UNDER MITERED END NEEDS TO BE DUG OUT ** NEED A MINIMUM OF 6 INCHES OF CONCRETE IN APRON OUT TO EDGE OF ROAD MEASURING LESS THAN 6 INCHES AT EDGE OF ROAD ** BACK FILL AROUND FORMS TO CONTAIN CONCRETE WITHIN THE POURING AREA _________________________________________________________________________________________________________________ 8/21/2024 - PREVIOUS INSPECTION NOTES 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ROW- PRE-APRON (PRE-POUR) 08/21/2024 Disapproved - NO FEE TPOLACEK
Note: 08/21/24 TPOLACEK*** CULVERT PIPE IS OUT OF TOLERENCE OVER THE .10 ALLOWENCE. PLEASE DOUBLE CHECK BM ELEVATION AND CENTERLINE ELEVATIONS ON SWALE PLAN DIAGRAM AND RESE THE CULVERT .
ELECTRIC - EARLY POWER 08/15/2024 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 7/16/2024 12:39:53 PM *** Authorize release of email to fpl.
INSULATION 07/17/2024 APPROVED FWILLIS
ELECTRIC-TUG 07/16/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 7/16/2024 12:39:53 PM *** Authorize release of email to fpl.
LATH/BRICK/ WATER BARRIER 07/16/2024 APPROVED FWILLIS
ALL ROUGH 07/12/2024 APPROVED JSTEWART
GRAVITY SEWER TEST 07/09/2024 APPROVED MGIBSON
SEWER TIE IN 07/09/2024 APPROVED MGIBSON
ROOF VALLEY & METAL 07/08/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2024 APPROVED FWILLIS
ROOF SHEATHING 06/25/2024 APPROVED FWILLIS
WALL SHEATHING 06/25/2024 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 06/24/2024 APPROVED TBAKER
TIE BEAM / LINTEL 03/12/2024 APPROVED FWILLIS
MONOLITHIC SLAB 03/01/2024 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 02/23/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/12/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
MECH CANCEL 10/03/2024 10/03/2024
Note: No review needed. Energy calcs already updated
SW1 COMPLETE 09/11/2024 06/24/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
MECH HOLD 09/11/2024 09/16/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM energy calcs match ones previously approved.
ENGIN1 COMPLETE 06/21/2024 06/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 HOLD 04/22/2024 04/23/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM COPC standards require that new slab elevation be within .2' of the elevation on the approved site plan AND be within .83' of any adjacent slab. Please contact Ms. Jordan Meyers for more information - 386-986-4789
SW1 HOLD 04/22/2024 04/25/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) The main structure FFE is out of tolerance. Min. FFE must be no less than 12" above the road centerline. Max. FFE must be no more than 22" above the road centerline. Additionally, the FFE must be within 10" of adjoining improved lots FFE. The structure FFE may exceed the road centerline tolerance in order to match the FFE of adjoining improved lots, so as to avoind being significantly lower.
ZON COMPLETE 04/22/2024 04/22/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 HOLD 03/19/2024 03/19/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM COPC standards require that new slab elevation be within .2' of the elevation on the approved site plan AND be within .83' of any adjacent slab. Please contact Ms. Jordan Meyers for more information - 386-986-4789
BLD COMPLETE 03/19/2024 03/22/2024
Note: Released By: JIM WALKER - - JWALKER@PALMCOASTGOV.COM
MECH COMPLETE 03/19/2024 03/20/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 03/13/2024 03/13/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM COPC standards require that new slab elevation be within .2' of the elevation on the approved site plan AND be within .83' of any adjacent slab.
ZON COMPLETE 03/13/2024 03/13/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN INFORMATION 03/12/2024 03/12/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No survey submitted
ENGIN1 HOLD 02/22/2024 02/22/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab.
ZON COMPLETE 02/22/2024 02/22/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 01/24/2024 01/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 12/15/2023 12/15/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC COMPLETE 12/13/2023 12/14/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/13/2023 12/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 12/13/2023 12/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 HOLD 12/07/2023 12/07/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Survey elevations off from ITT as-builts and COPC GPS by 1'
BLD COMPLETE 11/29/2023 11/29/2023
Note: Released By: JPI
CUSVC COMPLETE 11/29/2023 12/04/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 11/29/2023 12/01/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 3.NEC 2017 210.52
ENGIN1 COMPLETE 11/29/2023 11/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/29/2023 11/30/2023
LOCATE COMPLETE 11/29/2023 12/05/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/29/2023 11/30/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/29/2023 11/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/29/2023 11/29/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 11/29/2023 12/04/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 11/29/2023 01/17/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 30 ¤30.00 10/04/2024
SW ENG - REVIEW 20 ¤20.00 01/09/2024
SW ENG RES REVIEW 200 ¤200.00 01/09/2024
SEWER CREDIT (¤1,146.88) 01/09/2024
SEWER INSPECTION ¤25.00 01/09/2024
SEWER CAPITAL FACILITY ¤5,441.03 01/09/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 01/09/2024
SITE PLAN 30 ¤30.00 01/09/2024
WATER- TURN ON ¤25.00 01/09/2024
ADJUSTMENT 50% (¤599.22) 01/09/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/09/2024
INSPECTION - RESIDENTIAL ¤910.25 01/09/2024
PLAN REVIEW - RESIDENTIAL ¤258.18 01/09/2024
CONNECTION FEES ¤1,187.26 01/09/2024
FC IMPACT FEE EMS ¤62.00 01/09/2024
IMPACT FEE FIRE ¤428.09 01/09/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/09/2024
FC IMPACT FEE LIBRARY ¤268.00 01/09/2024
IMPACT FEE PARKS ¤1,800.99 01/09/2024
IMPACT FEE SCHOOL ¤5,450.00 01/09/2024
IMPACT FEE TRANSPORTATION ¤1,812.00 01/09/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/09/2024
SURCHARGE FS 533.721 ¤5.99 01/09/2024
SURCHARGE - FS 468.631 ¤8.99 01/09/2024
SW ENG - FOUNDATION SURVEY ¤20.00 01/09/2024
SW ENG INSPECTION 80 ¤80.00 01/09/2024
SW ENG PRE APRON ¤30.00 01/09/2024
Fees Total Due: ¤0.00 Total Paid: ¤20,614.19