I want to search for...

Permit #2023111154

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00110-0100
CONDITIONED SPACE: 3092 sqft
GARAGE: 896 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
OPENED PORCH (WITH ROOF) : 164 sqft
Total Square Footage: 4262 sqft
Block: 00110
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: 774-696-6541
Location Address: 40 FARMSWORTH DR
Type: DU - DUPLEX
Issue Date: 12/29/2023
NOC: RECORDED
Applicant name: JOHN DESMOND
Owner: CROFT GEORGE H JR

Address

11 CHESNEY CT

PALM COAST, FL 32167

Lot: 0100
Contracted Stated Job Value: ¤449,650.00
Job Description: Duplex
Type: CN

Contractor

COMPLETE BUILDERS LLC
Status Location Address State License Number Phone
INACTIVE

15 CHERRYTREE CT

PALM COAST, FL 32137

CGC1530956 (Exp: 08/31/2026) 774-696-6541

Sub Contractors

FRANK E SEVERINO
Status Location Address State License Number Phone Fax
ACTIVE

1360 N NOVA RD

DAYTONA BEACH, FL 32117

CBC060543 (Exp: 08/31/2026) 386-253-1943 386-238-0139
JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/13/2024 FINAL APPROVED JSTEWART
Note: 8/8/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/8/2024 11:20:12 AM *** previous notes not rectified.... Side B. 2. Please seal AHU stand all the way around (gaps and holes) R402.4 Energy calcs at time of inspection have been submitted but not approved, need aproval prior to final. 8/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/6/2024 3:06:01 PM *** Side A. 1. Outlet at ODU needs gfci protection. NEC 210.8 2. Seal exterior wall penetration at service grounds, and secure ...FBC EC TABLE R402.4.1.1 3. seal wall penetration at AHU closet power R402.4 4. Garage outlets require GFCI protection. NEC 210.8 5. Seal tub spout to wall FBCR P2705.1 6. Kitchen countertop receptacles each side of range require GFCI protection NEC 210.8 7. Breaker Panel is mis labled. NEC 408.4 8. Receptacle for dish washer is Hot/grd reversed 9. Please submit a energy calcs revision for equipment installed. Side B.......1. Outlet at ODU needs gfci protection. NEC 210.8 2. Please seal AHU stand all the way around (gaps and holes) 3. seal wall penetration at AHU closet power R402.4 4. Attic access requires functioning light (No bulb) 5. All Bathroom outlets require GFCI protection. NEC 210.8 6. No hot water P2705.1 – 4 7. seal Tub spout to wall FBCR P2705.1 8. Kitchen counter top receptacle in corner requires GFCI protection. NEC 210.8 9. Kitchen island end receptacle requires GFCI protection NEC 210.8 10. Dishwasher/disp receptacles require GFCI protection. NEC 210.8 11. Condensation discharge at ODU needs 12" from foundation wall FBCR 318.5 12. need Locking caps at ODU FBCR M1411.8
BLD - BUILDING FINAL 08/08/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/8/2024 11:20:12 AM *** previous notes not rectified.... Side B. 2. Please seal AHU stand all the way around (gaps and holes) R402.4 Energy calcs at time of inspection have been submitted but not approved, need aproval prior to final. 8/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/6/2024 3:06:01 PM *** Side A. 1. Outlet at ODU needs gfci protection. NEC 210.8 2. Seal exterior wall penetration at service grounds, and secure ...FBC EC TABLE R402.4.1.1 3. seal wall penetration at AHU closet power R402.4 4. Garage outlets require GFCI protection. NEC 210.8 5. Seal tub spout to wall FBCR P2705.1 6. Kitchen countertop receptacles each side of range require GFCI protection NEC 210.8 7. Breaker Panel is mis labled. NEC 408.4 8. Receptacle for dish washer is Hot/grd reversed 9. Please submit a energy calcs revision for equipment installed. Side B.......1. Outlet at ODU needs gfci protection. NEC 210.8 2. Please seal AHU stand all the way around (gaps and holes) 3. seal wall penetration at AHU closet power R402.4 4. Attic access requires functioning light (No bulb) 5. All Bathroom outlets require GFCI protection. NEC 210.8 6. No hot water P2705.1 – 4 7. seal Tub spout to wall FBCR P2705.1 8. Kitchen counter top receptacle in corner requires GFCI protection. NEC 210.8 9. Kitchen island end receptacle requires GFCI protection NEC 210.8 10. Dishwasher/disp receptacles require GFCI protection. NEC 210.8 11. Condensation discharge at ODU needs 12" from foundation wall FBCR 318.5 12. need Locking caps at ODU FBCR M1411.8
BLD - BUILDING FINAL 08/06/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/6/2024 3:06:01 PM *** Side A. 1. Outlet at ODU needs gfci protection. NEC 210.8 2. Seal exterior wall penetration at service grounds, and secure ...FBC EC TABLE R402.4.1.1 3. seal wall penetration at AHU closet power R402.4 4. Garage outlets require GFCI protection. NEC 210.8 5. Seal tub spout to wall FBCR P2705.1 6. Kitchen countertop receptacles each side of range require GFCI protection NEC 210.8 7. Breaker Panel is mis labled. NEC 408.4 8. Receptacle for dish washer is Hot/grd reversed 9. Please submit a energy calcs revision for equipment installed. Side B.......1. Outlet at ODU needs gfci protection. NEC 210.8 2. Please seal AHU stand all the way around (gaps and holes) 3. seal wall penetration at AHU closet power R402.4 4. Attic access requires functioning light (No bulb) 5. All Bathroom outlets require GFCI protection. NEC 210.8 6. No hot water P2705.1 – 4 7. seal Tub spout to wall FBCR P2705.1 8. Kitchen counter top receptacle in corner requires GFCI protection. NEC 210.8 9. Kitchen island end receptacle requires GFCI protection NEC 210.8 10. Dishwasher/disp receptacles require GFCI protection. NEC 210.8 11. Condensation discharge at ODU needs 12" from foundation wall FBCR 318.5 12. need Locking caps at ODU FBCR M1411.8
ROW - FINAL APRON (AFTER POUR) 08/06/2024 APPROVED EMADISON
ROW - FINAL INSPECTION 08/06/2024 APPROVED EMADISON
Note:
U -UTILITY RESIDENTIAL FINAL 08/06/2024 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/05/2024 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 08/05/2024 APPROVED - AS NOTED EMADISON
Note: ** 08/05/24 BEFORE ROW STORMWATER FINAL REMOVE ***ALL*** TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON RIGHT AD THE RESERVED PARCEL IN THE REAR
ELECTRIC - EARLY POWER 07/08/2024 APPROVED JWALKER
ELECTRIC - EARLY POWER 06/28/2024 CANCELLED BY APPLICANT RMARTIN
ROW- PRE-APRON (PRE-POUR) 06/11/2024 APPROVED - AS NOTED EMADISON
Note: ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/10/24 FORM BOARDS ON LEFT SIDE DRIVEWAY WERE RUN OVER AND BUSTED WHEN INSPECTOR ARRIVED ** SEE ATTACHED PHOTOS FROM TDAYS INSPECTION _______________________________________________________________________________________________________________________ 6/6/2024 - PREVIOUS INSPECTION NOTES ** 06/06/24 RIGHT SIDE DRIVEWAY NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY POUR AREA ABOVE THE ROW (RIGHT OF WAY) ** LEFT SIDE DRIVEWAY NEED A MINIMUM OF 2 INCHES OF CONCRETE OVER THE CULVERT AT MITERED ENDS LEFT SIDE MITERED FORMS ARE TOO LOW __________________________________________________________________________________________________________________ 6/3/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 INSPECTOR UNABLE TO ACCESS BENCH MARK ON POWER POLE DUE TO PERMIT BOC AND A 2X4 ATTACHED TO POLE ALONDSIDE THEBENCH MARK NAIL ** SEE ATTACHD PHOTOS
ROW- PRE-APRON (PRE-POUR) 06/10/2024 Disapproved - NO FEE EMADISON
Note: ** 06/10/24 FORM BOARDS ON LEFT SIDE DRIVEWAY WERE RUN OVER AND BUSTED WHEN INSPECTOR ARRIVED ** SEE ATTACHED PHOTOS FROM TDAYS INSPECTION _______________________________________________________________________________________________________________________ 6/6/2024 - PREVIOUS INSPECTION NOTES ** 06/06/24 RIGHT SIDE DRIVEWAY NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY POUR AREA ABOVE THE ROW (RIGHT OF WAY) ** LEFT SIDE DRIVEWAY NEED A MINIMUM OF 2 INCHES OF CONCRETE OVER THE CULVERT AT MITERED ENDS LEFT SIDE MITERED FORMS ARE TOO LOW __________________________________________________________________________________________________________________ 6/3/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 INSPECTOR UNABLE TO ACCESS BENCH MARK ON POWER POLE DUE TO PERMIT BOC AND A 2X4 ATTACHED TO POLE ALONDSIDE THEBENCH MARK NAIL ** SEE ATTACHD PHOTOS
ROW- PRE-APRON (PRE-POUR) 06/06/2024 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/06/24 RIGHT SIDE DRIVEWAY NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY POUR AREA ABOVE THE ROW (RIGHT OF WAY) ** LEFT SIDE DRIVEWAY NEED A MINIMUM OF 2 INCHES OF CONCRETE OVER THE CULVERT AT MITERED ENDS LEFT SIDE MITERED FORMS ARE TOO LOW __________________________________________________________________________________________________________________ 6/3/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 INSPECTOR UNABLE TO ACCESS BENCH MARK ON POWER POLE DUE TO PERMIT BOC AND A 2X4 ATTACHED TO POLE ALONDSIDE THEBENCH MARK NAIL ** SEE ATTACHD PHOTOS
ROW- PRE-APRON (PRE-POUR) 06/03/2024 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/03/24 INSPECTOR UNABLE TO ACCESS BENCH MARK ON POWER POLE DUE TO PERMIT BOC AND A 2X4 ATTACHED TO POLE ALONDSIDE THEBENCH MARK NAIL ** SEE ATTACHD PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/30/2024 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 05/15/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 05/15/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 04/10/2024 APPROVED FWILLIS
Note: 4/9/2024 - PREVIOUS INSPECTION NOTES 4/9/24- Both sides. Please firestop all miss drilled holes in top plate, and all Plumbing line top plate penetrations. Please check all.
INSULATION 04/09/2024 Disapproved - NO FEE JSTEWART
Note: 4/9/24- Both sides. Please firestop all miss drilled holes in top plate, and all Plumbing line top plate penetrations. Please check all.
LATH/BRICK/ WATER BARRIER 04/05/2024 APPROVED JWALKER
ALL ROUGH 04/04/2024 APPROVED - AS NOTED JWALKER
Note: 1. Unit B 5' DWV head test is not holding water. 2. Units A and B seal the dryer ducts and microwave ducts mechanical joints completely. Check for corrections at Insulation insp.
FIREWALL FINAL 03/22/2024 FINAL APPROVED JSTEWART
Note: 3/14/2024 - PREVIOUS INSPECTION NOTES 03-14-2024 CMU at refrigerator box has been damaged on both sides. Please submit an engineering letter for the repair to be made. A detail is also needed as to how reinstall the refrigerator box. Fire rated assembly with a one hour rated wall.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2024 APPROVED AGAETANO
Note: 3/20/2024 - PREVIOUS INSPECTION NOTES 3/19/2024 - PREVIOUS INSPECTION NOTES 03-19-2024 Engineering packet not on site. Firewall final not approved. 03-20-2024 1. Firewall final not approved only Accepted.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/20/2024 Disapproved - NO FEE AGAETANO
Note: 3/19/2024 - PREVIOUS INSPECTION NOTES 03-19-2024 Engineering packet not on site. Firewall final not approved. 03-20-2024 1. Firewall final not approved only Accepted. Engineering repair has not been attached or submitted. Repair not on site.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/19/2024 Disapproved - NO FEE AGAETANO
Note: 03-19-2024 Engineering packet not on site. Firewall final not approved.
FIREWALL FINAL 03/14/2024 Disapproved - NO FEE AGAETANO
Note: 03-14-2024 CMU at refrigerator box has been damaged on both sides. Please submit an engineering letter for the repair to be made. A detail is also needed as to how reinstall the refrigerator box. Fire rated assembly with a one hour rated wall.
FIREWALL DRYWALL NAILING 03/13/2024 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2467 03-06-2024 Job box is a mess. Please organize.
FIREWALL FRAMING 03/06/2024 APPROVED - AS NOTED AGAETANO
Note: 2/27/2024 - PREVIOUS INSPECTION NOTES STRAPS COMING FROM CMU NOT FASTENED AT ALL. OTHERS NOT FASTENED VERTICALLY NOT WRAPPED AROUND BOTTOM CHORD. 03-06-2024 Job box is a mess. Please organize.
ROOF VALLEY & METAL 03/06/2024 APPROVED - AS NOTED AGAETANO
Note: 03-06-2024 Job box is a mess. Please organize.
WALL SHEATHING 02/27/2024 APPROVED FWILLIS
FIREWALL FRAMING 02/27/2024 Disapproved - NO FEE FWILLIS
Note: STRAPS COMING FROM CMU NOT FASTENED AT ALL. OTHERS NOT FASTENED VERTICALLY NOT WRAPPED AROUND BOTTOM CHORD.
FOUND SURVEY APPROVED (OFFICE) 02/20/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/16/2024 APPROVED AGAETANO
Note: 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/2024 - PREVIOUS INSPECTION NOTES 02-15-2024 1. Missed dowel. Check all. 2. Clearance from rebar. Ceck all. 3. Please remove trash from jobsite prior to next inspection. 4. Drawings are ripped and job box is disorganized. Please provide a clean. large set of approved drawings. Inspection stopped. 02-15-2024 Inspector returned to inspection as per contractor request. Dowels not epoxy. Noted on drawings.
TIE BEAM / LINTEL 02/15/2024 Disapproved - NO FEE AGAETANO
Note: 02-15-2024 1. Missed dowel. Check all. 2. Clearance from rebar. Check all. 3. Please remove trash from jobsite prior to next inspection. 4. Drawings are ripped and job box is disorganized. Please provide a clean. large set of approved drawings. Inspection stopped.
TIE BEAM / LINTEL 02/15/2024 Disapproved -FEE REQUIRED AGAETANO
Note: 2/15/2024 - PREVIOUS INSPECTION NOTES 02-15-2024 1. Missed dowel. Check all. 2. Clearance from rebar. Ceck all. 3. Please remove trash from jobsite prior to next inspection. 4. Drawings are ripped and job box is disorganized. Please provide a clean. large set of approved drawings. Inspection stopped. 02-15-2024 Inspector returned to inspection as per contractor request. Dowels not epoxy. Noted on drawings.
MONOLITHIC SLAB 02/02/2024 APPROVED AGAETANO
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES 1/31/24- 1/31/24- Interior bearing wall footing (Master Bedroom wall) Not to Plans per Detail 8 on both sides of Duplex. Please install sleaves 2 pipe sizes higher at 1" pipes going through foundation wall Both sides. P2603.4 Pipes through foundation walls. Please install relieving arch at Liquid line chase passing through foundation wall both sides. P2603.4 Pipes through foundation walls.
MONOLITHIC SLAB 01/31/2024 Disapproved -FEE REQUIRED JSTEWART
Note: 1/31/24- 1/31/24- Interior bearing wall footing (Master Bedroom wall) Not to Plans per Detail 8 on both sides of Duplex. Please install sleaves 2 pipe sizes higher at 1" pipes going through foundation wall Both sides. P2603.4 Pipes through foundation walls. Please install relieving arch at Liquid line chase passing through foundation wall both sides. P2603.4 Pipes through foundation walls.
U-CROSS CONNECTION 01/31/2024 APPROVED DHANEY
PLUMBING 1ST ROUGH UNDERGROUND 01/26/2024 APPROVED KSANDOE
WATER METER INSTALLATION REQUEST 01/05/2024 APPROVED TCHURCHILL
WILDLIFE CHECK - ENVIRONMENTAL 11/30/2023 APPROVED DRODRIGUEZ

Review History

Department Status Date In Date Out
MECH COMPLETE 08/07/2024 08/12/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/18/2024 03/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/18/2024 03/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/18/2024 03/25/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 03/18/2024 03/18/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 03/12/2024 03/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/12/2024 03/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/12/2024 03/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/12/2024 03/12/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD HOLD 03/06/2024 03/11/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Approval stamped page is for wrong address.
BLD HOLD 03/05/2024 03/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
ENGIN1 COMPLETE 02/20/2024 02/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/20/2024 02/20/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/09/2024 01/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 01/09/2024 01/17/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 01/09/2024 01/09/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 12/14/2023 12/15/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/06/2023 12/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 12/06/2023 12/13/2023
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 12/06/2023 12/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC HOLD 12/06/2023 12/11/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 3. NEC 2017 210.52 2. Submit a duplex riser diagram.
BLD COMPLETE 12/04/2023 12/04/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLENV COMPLETE 11/30/2023 11/30/2023
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 11/30/23 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
CUSVC COMPLETE 11/29/2023 12/04/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 11/29/2023 11/30/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to upload electrical page. 2. Submit electrical load calcs 3. Submit electrical riser diagram.
ENGIN1 COMPLETE 11/29/2023 11/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/29/2023 11/30/2023
LOCATE COMPLETE 11/29/2023 12/05/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/29/2023 12/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/29/2023 11/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 11/29/2023 11/30/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Incorrect flood map number on site plan/survey
BADMIN COMPLETE 11/29/2023 12/04/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 11/29/2023 01/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 11/29/2023 12/01/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/13/2024
REINSPECTION RESIDENTIAL ¤40.00 08/13/2024
REINSPECTION RESIDENTIAL ¤40.00 08/13/2024
REINSPECTION RESIDENTIAL ¤40.00 08/13/2024
REINSPECTION RESIDENTIAL ¤40.00 08/13/2024
SW ENG REINSPECTION 30 ¤30.00 08/13/2024
SW ENG REINSPECTION 30 ¤30.00 08/13/2024
SW ENG - REVIEW 20 ¤20.00 12/29/2023
SW ENG RES REVIEW 200 ¤200.00 12/29/2023
SEWER CREDIT (¤1,147.00) 12/29/2023
SEWER INSPECTION ¤25.00 12/29/2023
SEWER CAPITAL FACILITY ¤10,882.06 12/29/2023
WATER CAPITAL FACILITY FEE ¤7,989.02 12/29/2023
SITE PLAN 30 ¤30.00 12/29/2023
WATER- TURN ON ¤50.00 12/29/2023
ADJUSTMENT 50% (¤1,052.82) 12/29/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/29/2023
INSPECTION - RESIDENTIAL ¤1,617.00 12/29/2023
PLAN REVIEW - RESIDENTIAL ¤458.64 12/29/2023
CONNECTION FEES ¤2,374.52 12/29/2023
FC IMPACT FEE EMS ¤124.00 12/29/2023
IMPACT FEE FIRE ¤856.18 12/29/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 12/29/2023
FC IMPACT FEE LIBRARY ¤536.00 12/29/2023
IMPACT FEE PARKS ¤3,600.18 12/29/2023
IMPACT FEE SCHOOL ¤10,900.00 12/29/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 12/29/2023
WATER -IRRIGATION INSPECTION ¤50.00 12/29/2023
SURCHARGE FS 533.721 ¤10.53 12/29/2023
SURCHARGE - FS 468.631 ¤15.79 12/29/2023
SW ENG - FOUNDATION SURVEY ¤20.00 12/29/2023
SW ENG INSPECTION 80 ¤80.00 12/29/2023
SW ENG PRE APRON ¤30.00 12/29/2023
Fees Total Due: ¤0.00 Total Paid: ¤41,199.60