I want to search for...

Permit #2023120081

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00120-0090
CONDITIONED SPACE: 1480 sqft
CONDITIONED SPACE: 1480 sqft
GARAGE: 500 sqft
GARAGE: 500 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 4080 sqft
Block: 00120
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 863-647-5815
Location Address: 18 PONDEROSA LN
Type: DU - DUPLEX
Issue Date: 02/13/2024
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

5116 SOUTH LAKELAND DRIVE

LAKELAND, FL 33813

Lot: 0090
Contracted Stated Job Value: ¤315,000.00
Job Description: Duplex - The Opportunity II
Type: CN
Original Permit #: 2023110530

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

KYLE RODBOURN
Status Location Address State License Number Phone
ACTIVE

1325 W HWY 100

BUNNELL, FL 32110

CAC1821358 (Exp: 08/31/2026) 386-586-9039
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/18/2024 FINAL APPROVED RSIMS
Note: 10/17/2024 - PREVIOUS INSPECTION NOTES 10/17/24: 1). Unit A: 1 of the three port caps is still not locking. M1411.8 (Showed CM). 2). Both Units: Screen is removed from Dryer Gooseneck which exposed the missing self-closing damper. FBC-M1502.3 - Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer’s installation instructions. If the manufacturer’s instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4
BLD - BUILDING FINAL 10/17/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 10/17/2024 10:57:19 AM *** 10/17/24: 1). Unit A: 1 of the three port caps is still not locking. M1411.8 (Showed CM). 2). Both Units: Screen is removed from Dryer Gooseneck which exposed the missing self-closing damper. FBC-M1502.3 - Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer’s installation instructions. If the manufacturer’s instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4
BLD - BUILDING FINAL 10/15/2024 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4
BLD - BUILDING FINAL 10/07/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/7/2024 11:24:15 AM *** 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4
ROW - FINAL APRON (AFTER POUR) 10/07/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES.
ROW - STORMWATER FINAL 10/07/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/02/2024 APPROVED - AS NOTED FSLADISH
Note: 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES.
U-CROSS CONNECTION 10/02/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 10/2/2024 10:34:58 AM *** both units with potable irrigation and PVB's-no crss conection
ROW FIELD SURVEY /GRADING CERTIFICATION 09/19/2024 CANCELLED BY APPLICANT WEB
Note: 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/18/2024 APPROVED TPOLACEK
Note: 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** FINAL SURVEY MUST INDICATE TYPE OF CONSTRUCTION. THIS IS USED TO DETERMINE THE CORRECT ELEVATION OF SOD SURROUNDING STRUCTURE. REGARDLESS OF IF YOU HAVE THE ELEVATION IT IS REQUIRED ON ALL SURVEYS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2024 - PREVIOUS INSPECTION NOTES 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/18/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/17/2024 Disapproved - NO FEE TPOLACEK
Note: 09/17/24 TPOLACEK*** FINAL SURVEY MUST INDICATE TYPE OF CONSTRUCTION. THIS IS USED TO DETERMINE THE CORRECT ELEVATION OF SOD SURROUNDING STRUCTURE. REGARDLESS OF IF YOU HAVE THE ELEVATION IT IS REQUIRED ON ALL SURVEYS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2024 - PREVIOUS INSPECTION NOTES 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/27/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.
ROW- PRE-APRON (PRE-POUR) 08/12/2024 APPROVED - AS NOTED FSLADISH
Note: 8/12/24 BOTH PIPE ELEVATIONS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW- PRE-APRON (PRE-POUR) 08/09/2024 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY. THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY. THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 07/17/2024 APPROVED RSIMS
Note: 7/17/24: FPL emailed to release power. 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Service feeds need to be landed at main panels for overhead power at this inspection. Inspector Notes from Inspection 2170 2/23/24: FPL emailed - approved for Temp Pole.
ELECTRIC - EARLY POWER 07/16/2024 Disapproved - NO FEE RSIMS
Note: 7/16/24: 1). Service feeds need to be landed at main panels for overhead power at this inspection. Inspector Notes from Inspection 2170 2/23/24: FPL emailed - approved for Temp Pole.
INSULATION 05/22/2024 APPROVED RSIMS
Note: 5/20/2024 - PREVIOUS INSPECTION NOTES 5/16/2024 - PREVIOUS INSPECTION NOTES 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking (above bathtub faucet wall). does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. 05-20-2024 Above issues not resolved. 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. Paint not complete over spray foam. Contractor was on site at last inspection and was aware of issues when he was spray foaming the window jambs.
INSULATION 05/20/2024 Disapproved - NO FEE AGAETANO
Note: 5/16/2024 - PREVIOUS INSPECTION NOTES 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. 05-20-2024 Above issues not resolved. 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. Paint not complete over spray foam. Contractor was on site at last inspection and was aware of issues when he was spray foaming the window jambs.
INSULATION 05/16/2024 Disapproved - NO FEE RSIMS
Note: 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final.
PEP TANK INSTALLATION REQUEST 05/16/2024 APPROVED CBOWERMASTER
INSULATION 05/15/2024 Disapproved - NO FEE AGAETANO
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final.
INSULATION 05/14/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc.
ALL ROUGH 05/09/2024 APPROVED - AS NOTED RSIMS
Note: 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc.
ALL ROUGH 04/23/2024 Disapproved -FEE REQUIRED RSIMS
Note: 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc.
LATH/BRICK/ WATER BARRIER 04/22/2024 APPROVED KSANDOE
LATH/BRICK/ WATER BARRIER 04/19/2024 CANCELLED BY APPLICANT WEB
ALL ROUGH 04/10/2024 Disapproved - NO FEE RSIMS
Note: 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc.
FIREWALL DRYWALL NAILING 04/08/2024 APPROVED FWILLIS
ROOF VALLEY & METAL 03/22/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/15/2024 APPROVED BTAYLOR
Note: 3/11/2024 - PREVIOUS INSPECTION NOTES BEARING WALL NOT AS PER PLAN.
WALL SHEATHING 03/11/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/11/2024 Disapproved - NO FEE FWILLIS
Note: BEARING WALL NOT AS PER PLAN.
FOUND SURVEY APPROVED (OFFICE) 03/08/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/29/2024 APPROVED KSANDOE
ELECTRIC TEMP POLE 02/23/2024 APPROVED - AS NOTED RSIMS
Note: 2/23/24: FPL emailed - approved for Temp Pole.
MONOLITHIC SLAB 02/21/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 02/16/2024 APPROVED - AS NOTED MGIBSON
Note: NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY
WATER METER INSTALLATION REQUEST 02/16/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/06/2024 05/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/30/2024 05/03/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a master permit. Provide only duct layout and heatload as separate files
BLD COMPLETE 04/04/2024 04/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/07/2024 03/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/07/2024 03/07/2024
Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM
BLD HOLD 03/04/2024 03/04/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. This is a 2023 permit. So it falls under the 2020 FBC. 2. Why are you uploading this letter all inspections were approved?
BLD COMPLETE 03/04/2024 03/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter was uploaded by accident
SW1 COMPLETE 01/23/2024 01/30/2024
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/23/2024 01/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/23/2024 01/24/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 01/11/2024 01/11/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 01/08/2024 01/08/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring the originals paperwork for easment to our office.
SW1 HOLD 01/08/2024 01/19/2024
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Rear property line will hold water sent suggestions via email on 1/17/2024
ENGIN1 COMPLETE 01/08/2024 01/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SWALE COMPLETE 01/08/2024 01/19/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH COMPLETE 12/21/2023 01/02/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ZON HOLD 12/21/2023 12/21/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Provide the sebacks from ac to the property line as they are only allowed 2 ft in the easement Please bring the originals paperwork for easment to our office.
SW1 HOLD 12/21/2023 01/02/2024
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please make a common property line swale on vacant lot side, It would be easier to grade and maintain with an 8' side tie.
CUSVC COMPLETE 12/04/2023 12/06/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
GAS CANCEL 12/04/2023 12/04/2023
LOCATE COMPLETE 12/04/2023 12/04/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 12/04/2023 12/04/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
SW1 HOLD 12/04/2023 12/12/2023
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please show flow arrows to show drainage direction, In rear of lot you can not negatively impact adjioning lot ( berm to far away from property line ) see Tech Manual 300.01, also show next door culvert with inv elv on site plan
ZON HOLD 12/04/2023 12/04/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan : Provide width of walkways Ac appears to be in the easement on the left side.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/17/2024
REINSPECTION RESIDENTIAL ¤40.00 10/17/2024
REINSPECTION RESIDENTIAL ¤40.00 10/17/2024
CONTRACTOR CHANGE ¤20.00 10/17/2024
SW ENG REINSPECTION 20 ¤20.00 10/17/2024
SW ENG - REVIEW 20 ¤20.00 02/13/2024
SW ENG RES REVIEW 200 ¤200.00 02/13/2024
SEWER CREDIT (¤1,300.00) 02/13/2024
SEWER INSPECTION ¤25.00 02/13/2024
SEWER CAPITAL FACILITY ¤10,882.06 02/13/2024
WATER CAPITAL FACILITY FEE ¤7,989.02 02/13/2024
SITE PLAN 30 ¤30.00 02/13/2024
FC IMPACT FEE EMS ¤124.00 02/13/2024
IMPACT FEE FIRE ¤856.18 02/13/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/13/2024
FC IMPACT FEE LIBRARY ¤536.00 02/13/2024
IMPACT FEE PARKS ¤3,600.18 02/13/2024
IMPACT FEE SCHOOL ¤10,900.00 02/13/2024
RECORDING FEE REIMBURSE DOC ¤35.50 02/13/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 02/13/2024
WATER -IRRIGATION INSPECTION ¤50.00 02/13/2024
SURCHARGE FS 533.721 ¤5.11 02/13/2024
SURCHARGE - FS 468.631 ¤7.67 02/13/2024
SW ENG - FOUNDATION SURVEY ¤20.00 02/13/2024
SW ENG INSPECTION 80 ¤80.00 02/13/2024
SW ENG PRE APRON ¤30.00 02/13/2024
CONNECTION FEES ¤2,374.52 02/13/2024
WATER- TURN ON ¤50.00 02/13/2024
ADJUSTMENT 50% (¤511.13) 02/13/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/13/2024
INSPECTION - RESIDENTIAL ¤866.25 02/13/2024
PLAN REVIEW - APPROVED MASTER ¤126.00 02/13/2024
Fees Total Due: ¤0.00 Total Paid: ¤40,504.86