Permit #2023120081
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00120-0090 |
| CONDITIONED SPACE: 1480 sqft |
| CONDITIONED SPACE: 1480 sqft |
| GARAGE: 500 sqft |
| GARAGE: 500 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 4080 sqft |
| Block: 00120 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 863-647-5815 |
| Location Address: 18 PONDEROSA LN |
| Type: DU - DUPLEX |
| Issue Date: 02/13/2024 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address 5116 SOUTH LAKELAND DRIVE LAKELAND, FL 33813 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤315,000.00 |
| Job Description: Duplex - The Opportunity II |
| Type: CN |
| Original Permit #: 2023110530 |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
KYLE RODBOURN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1325 W HWY 100 BUNNELL, FL 32110 |
CAC1821358 (Exp: 08/31/2026) | 386-586-9039 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/18/2024 | FINAL APPROVED | RSIMS |
| Note: 10/17/2024 - PREVIOUS INSPECTION NOTES 10/17/24: 1). Unit A: 1 of the three port caps is still not locking. M1411.8 (Showed CM). 2). Both Units: Screen is removed from Dryer Gooseneck which exposed the missing self-closing damper. FBC-M1502.3 - Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer’s installation instructions. If the manufacturer’s instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4 | |||
| BLD - BUILDING FINAL | 10/17/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/17/2024 10:57:19 AM *** 10/17/24: 1). Unit A: 1 of the three port caps is still not locking. M1411.8 (Showed CM). 2). Both Units: Screen is removed from Dryer Gooseneck which exposed the missing self-closing damper. FBC-M1502.3 - Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer’s installation instructions. If the manufacturer’s instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4 | |||
| BLD - BUILDING FINAL | 10/15/2024 | CANCELLED BY APPLICANT | CVANSTRAHLEN |
| Note: 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4 | |||
| BLD - BUILDING FINAL | 10/07/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/7/2024 11:24:15 AM *** 10/7/24: Unit A: 1). ODU: two of three locking caps are not installed. M1411.8 2). Large hole in the wall by the PEP Tank conduit needs to be repaired. FBCEC R402.4 3). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Unit B: 4). Master Bathroom: Toilet is not sealed fully at the base. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 5). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 6). Garage door opener is not operating. Could not test safety eyes, etc. FBC[A] 107.4 | |||
| ROW - FINAL APRON (AFTER POUR) | 10/07/2024 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES. | |||
| ROW - STORMWATER FINAL | 10/07/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/02/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/2/24 SOD CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. MET WITH LANDSCAPER AND SHOWED HIM WHERE A FEW MORE PIECES WERE REQUIRED. APPROVING AS NOTED THAT CORRECTIONS MADE. 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. New inspection due to canceled inspection 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES. | |||
| U-CROSS CONNECTION | 10/02/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/2/2024 10:34:58 AM *** both units with potable irrigation and PVB's-no crss conection | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/19/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 9/18/2024 - PREVIOUS INSPECTION NOTES 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/18/2024 | APPROVED | TPOLACEK |
| Note: 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** FINAL SURVEY MUST INDICATE TYPE OF CONSTRUCTION. THIS IS USED TO DETERMINE THE CORRECT ELEVATION OF SOD SURROUNDING STRUCTURE. REGARDLESS OF IF YOU HAVE THE ELEVATION IT IS REQUIRED ON ALL SURVEYS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2024 - PREVIOUS INSPECTION NOTES 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/18/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09/18/24 TPOLACEK** LEFT SIDE PROPERTY LINE MUST HAVE SOD IN PLACE AND REPAIR ALL WASHOUTS ALONG BACK FENCELINE ON BOTH SIDES. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/17/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 09/17/24 TPOLACEK*** FINAL SURVEY MUST INDICATE TYPE OF CONSTRUCTION. THIS IS USED TO DETERMINE THE CORRECT ELEVATION OF SOD SURROUNDING STRUCTURE. REGARDLESS OF IF YOU HAVE THE ELEVATION IT IS REQUIRED ON ALL SURVEYS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2024 - PREVIOUS INSPECTION NOTES 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/27/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE FINAL SURVEY SHOWS THAT YOU DONT HAVE THE MINIMUM AMOUNT OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) BOTH RIGHT AND LEFT DRAINAGE PATTERNS NEED TO HAVE POSITIVE FALL EVERY 20'. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/12/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/12/24 BOTH PIPE ELEVATIONS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/09/2024 | CANCELLED BY APPLICANT | WEB |
| GRAVITY SEWER TEST | 08/08/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY. THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 08/08/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY Inspector Notes from Inspection 2060 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY. THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC - EARLY POWER | 07/17/2024 | APPROVED | RSIMS |
| Note: 7/17/24: FPL emailed to release power. 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Service feeds need to be landed at main panels for overhead power at this inspection. Inspector Notes from Inspection 2170 2/23/24: FPL emailed - approved for Temp Pole. | |||
| ELECTRIC - EARLY POWER | 07/16/2024 | Disapproved - NO FEE | RSIMS |
| Note: 7/16/24: 1). Service feeds need to be landed at main panels for overhead power at this inspection. Inspector Notes from Inspection 2170 2/23/24: FPL emailed - approved for Temp Pole. | |||
| INSULATION | 05/22/2024 | APPROVED | RSIMS |
| Note: 5/20/2024 - PREVIOUS INSPECTION NOTES 5/16/2024 - PREVIOUS INSPECTION NOTES 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking (above bathtub faucet wall). does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. 05-20-2024 Above issues not resolved. 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. Paint not complete over spray foam. Contractor was on site at last inspection and was aware of issues when he was spray foaming the window jambs. | |||
| INSULATION | 05/20/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 5/16/2024 - PREVIOUS INSPECTION NOTES 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. 05-20-2024 Above issues not resolved. 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. Paint not complete over spray foam. Contractor was on site at last inspection and was aware of issues when he was spray foaming the window jambs. | |||
| INSULATION | 05/16/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/16/24: 1). Both Units: Missing firestop in center walls (behind drywall stacks) at horizontal wire runs. FBC-R302.11 - 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). Also, at top plate separation above bathtub pack out walls. 2). Unit A (Left side): Fireblocking does not meet the minimum thickness (1.5") as required by FBC-R302.11.1 Previously listed item 2 remains unresolved. 5/15/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. | |||
| PEP TANK INSTALLATION REQUEST | 05/16/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 05/15/2024 | Disapproved - NO FEE | AGAETANO |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. 05-15-2024 1. Please leave spray can on site to confirm proper sealant over spray foam. 2. All window jambs are not spray foamed. 3. Spray foam is not completely sealed at both garage unit entries. 4. Please label the Meter cans as required. Check meter can labeling at final. | |||
| INSULATION | 05/14/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2420 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. | |||
| ALL ROUGH | 05/09/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 5/9/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All bathroom metal exhaust ducts must either be crimped evenly using the Manufacturer approved crimping tool or must have a reducer installed at the fan dampered outlet. 2). Please label the Meter cans as required 4/23/2024 - PREVIOUS INSPECTION NOTES 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. | |||
| ALL ROUGH | 04/23/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/23/24: INSPECTION STOPPED AGAIN. PLEASE DO NOT SCHEDULE RE-INSPECTION UNTIL FULLY READY. Examples Only Again: Bathtubs are not filled to the OVERFLOW so that overflow piping can be tested, slab at bathtub is not fully repaired, water heater feeds are still not phased out, B side dryer exhaust is damaged and not connected/sealed properly above the top plate, most of the windows & doors cannot be checked due to stucco process having windows taped/sealed with plastic. Silt fence needs repair. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. | |||
| LATH/BRICK/ WATER BARRIER | 04/22/2024 | APPROVED | KSANDOE |
| LATH/BRICK/ WATER BARRIER | 04/19/2024 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 04/10/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/10/24: Inspection stopped! Not Ready! Incomplete plans in box/on-site (only 2 pages, no framing, electrical, etc.) Examples Only: Bathtubs not filled to overflow, wires not phased out, framing not complete above breaker box, service feeds not anchored as required, right side slab not repaired at tub drain, etc. | |||
| FIREWALL DRYWALL NAILING | 04/08/2024 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 03/22/2024 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/15/2024 | APPROVED | BTAYLOR |
| Note: 3/11/2024 - PREVIOUS INSPECTION NOTES BEARING WALL NOT AS PER PLAN. | |||
| WALL SHEATHING | 03/11/2024 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/11/2024 | Disapproved - NO FEE | FWILLIS |
| Note: BEARING WALL NOT AS PER PLAN. | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/08/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 02/29/2024 | APPROVED | KSANDOE |
| ELECTRIC TEMP POLE | 02/23/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 2/23/24: FPL emailed - approved for Temp Pole. | |||
| MONOLITHIC SLAB | 02/21/2024 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/16/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION 3307.1 PROTECTION OF PROPERTY | |||
| WATER METER INSTALLATION REQUEST | 02/16/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/06/2024 | 05/08/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/30/2024 | 05/03/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a master permit. Provide only duct layout and heatload as separate files | |||
| BLD | COMPLETE | 04/04/2024 | 04/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/07/2024 | 03/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/07/2024 | 03/07/2024 |
| Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/04/2024 | 03/04/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. This is a 2023 permit. So it falls under the 2020 FBC. 2. Why are you uploading this letter all inspections were approved? | |||
| BLD | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter was uploaded by accident | |||
| SW1 | COMPLETE | 01/23/2024 | 01/30/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/23/2024 | 01/24/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/23/2024 | 01/24/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/11/2024 | 01/11/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/08/2024 | 01/08/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring the originals paperwork for easment to our office. | |||
| SW1 | HOLD | 01/08/2024 | 01/19/2024 |
| Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Rear property line will hold water sent suggestions via email on 1/17/2024 | |||
| ENGIN1 | COMPLETE | 01/08/2024 | 01/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 01/08/2024 | 01/19/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/21/2023 | 01/02/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/21/2023 | 12/21/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Provide the sebacks from ac to the property line as they are only allowed 2 ft in the easement Please bring the originals paperwork for easment to our office. | |||
| SW1 | HOLD | 12/21/2023 | 01/02/2024 |
| Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please make a common property line swale on vacant lot side, It would be easier to grade and maintain with an 8' side tie. | |||
| CUSVC | COMPLETE | 12/04/2023 | 12/06/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/04/2023 | 12/04/2023 |
| LOCATE | COMPLETE | 12/04/2023 | 12/04/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/04/2023 | 12/04/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition | |||
| SW1 | HOLD | 12/04/2023 | 12/12/2023 |
| Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please show flow arrows to show drainage direction, In rear of lot you can not negatively impact adjioning lot ( berm to far away from property line ) see Tech Manual 300.01, also show next door culvert with inv elv on site plan | |||
| ZON | HOLD | 12/04/2023 | 12/04/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan : Provide width of walkways Ac appears to be in the easement on the left side. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 10/17/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 10/17/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 10/17/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/13/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/13/2024 |
| SEWER CREDIT | (¤1,300.00) | 02/13/2024 |
| SEWER INSPECTION | ¤25.00 | 02/13/2024 |
| SEWER CAPITAL FACILITY | ¤10,882.06 | 02/13/2024 |
| WATER CAPITAL FACILITY FEE | ¤7,989.02 | 02/13/2024 |
| SITE PLAN 30 | ¤30.00 | 02/13/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 02/13/2024 |
| IMPACT FEE FIRE | ¤856.18 | 02/13/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 02/13/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 02/13/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 02/13/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 02/13/2024 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 02/13/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 02/13/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 02/13/2024 |
| SURCHARGE FS 533.721 | ¤5.11 | 02/13/2024 |
| SURCHARGE - FS 468.631 | ¤7.67 | 02/13/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/13/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/13/2024 |
| SW ENG PRE APRON | ¤30.00 | 02/13/2024 |
| CONNECTION FEES | ¤2,374.52 | 02/13/2024 |
| WATER- TURN ON | ¤50.00 | 02/13/2024 |
| ADJUSTMENT 50% | (¤511.13) | 02/13/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/13/2024 |
| INSPECTION - RESIDENTIAL | ¤866.25 | 02/13/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤126.00 | 02/13/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤40,504.86 |