Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00560-0050
CONDITIONED SPACE: 1480 sqft
CONDITIONED SPACE: 1480 sqft
GARAGE: 500 sqft
GARAGE: 500 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 4080 sqft
Block: 00560
Subdivision: -
Job Phone: 863-647-5815
Location Address: 39 KARAS TR
Type: DU - DUPLEX
Issue Date: 12/19/2023
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

PO BOX 6254

LAKELAND , FL 33807

Lot: 0050
Contracted Stated Job Value: ¤315,000.00
Job Description: Duplex The Opportunity II
Type: CN
Original Permit #: 2023110530

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

KYLE RODBOURN
Status Location Address State License Number Phone
ACTIVE

1325 W HWY 100

BUNNELL, FL 32110

CAC1821358 (Exp: 08/31/2026) 386-586-9039
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/23/2024 FINAL APPROVED AGAETANO
Note: 8/20/2024 - PREVIOUS INSPECTION NOTES 8/20/24: Both Units: 1). Exterior sleeve for lineset needs to be sealed at bottom & top as required. (M2301.2.9) 2). Exterior temporary electric covers in soffit need to be replaced with weathertight covers as required. NEC - 406.6 / 406.9(2E) 3). Dryer exhausts need to be capped & labeled as required. FBC-M1502.4.7 -- Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked "future use" 4). Condensate drains cannot terminate from the soffit in front of the garage. M1411.3 Condensate disposal. Condensate from cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than 1/8 unit vertical in 12 units horizontalm (1-percent slope). Condensate shall not discharge into a street, alley or other areas where it would cause a nuisance. Side A: 5). Service mast pipes need to be sealed where they enter soffit. (FBC-R806.1) 6). Plumbing vent pipe on roof is too short (6" min. above roof on top side - P3103.1.1) & too close to bathroom exhaust gooseneck. (FBCR P3103.5) Side B: 7). Guest bathroom shower head leaks from the threads at the shower arm connection. 8). AHU: 2 different heater stickers show different maximum breaker amperage. Model numbers on both match.
BLD - BUILDING FINAL 08/20/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/20/2024 5:25:44 PM *** 8/20/24: Both Units: 1). Exterior sleeve for lineset needs to be sealed at bottom & top as required. (M2301.2.9) 2). Exterior temporary electric covers in soffit need to be replaced with weathertight covers as required. NEC - 406.6 / 406.9(2E) 3). Dryer exhausts need to be capped & labeled as required. FBC-M1502.4.7 -- Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked "future use" 4). Condensate drains cannot terminate from the soffit in front of the garage. M1411.3 Condensate disposal. Condensate from cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than 1/8 unit vertical in 12 units horizontalm (1-percent slope). Condensate shall not discharge into a street, alley or other areas where it would cause a nuisance. Side A: 5). Service mast pipes need to be sealed where they enter soffit. (FBC-R806.1) 6). Plumbing vent pipe on roof is too short (6" min. above roof on top side - P3103.1.1) & too close to bathroom exhaust gooseneck. (FBCR P3103.5) Side B: 7). Guest bathroom shower head leaks from the threads at the shower arm connection. 8). AHU: 2 different heater stickers show different maximum breaker amperage. Model numbers on both match.
ROW - FINAL APRON (AFTER POUR) 08/20/2024 APPROVED FSLADISH
Note: 8/20/24 PIPE ELEVATIONS ARE GOOD. CUTS MADE. CULVERTS CLEAR. HOT PATCHES COMPLETED AT THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. __________________________________________________________________________________________________________________________ 7/26/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW - STORMWATER FINAL 08/20/2024 APPROVED - AS NOTED FSLADISH
Note: 8/20/24 At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. _________________________________________________________________________________________________________________________ 7/26/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW - FINAL APRON (AFTER POUR) 07/26/2024 CANCELLED BY APPLICANT FSLADISH
Note: Inspector Notes from Inspection 9465 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW - STORMWATER FINAL 07/26/2024 CANCELLED BY APPLICANT FSLADISH
Note: Inspector Notes from Inspection 9465 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
U-CROSS CONNECTION 07/26/2024 APPROVED - AS NOTED BWRIGHT
Note: Has IRR. No CC
ROW- PROJECT STATUS 07/25/2024 APPROVED - AS NOTED FSLADISH
Note: 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/25/2024 APPROVED - AS NOTED FSLADISH
Note: 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW FIELD SURVEY /GRADING CERTIFICATION 07/25/2024 APPROVED - AS NOTED FSLADISH
Note: UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 7.25/24 AFTER RESHOOTING CULVERT PIPES FOUND THEY ARE STILL A SMALL BIT OUT OF TOLERANCE. I SPOKE TO MIKE CM FOR HULBERT HOMES AND LET HIM KNOW WHAT MY DECISION IS. THE DOWNSTREAM INVERT IS LOWER SO IN THIS SPECIFIC CASE I AM GOING TO APPROVE THIS SURVEY AS NOTED THAT DUE TO THE UPSTREAM CULVERT BEING HIGHER AND THE DOWNSTREAM CULVERT BEING LOWER WE WILL ALLOW A SLIGHT DEVEATION FROM NORMAL STANDARDS IN THIS PARTICULAR CASE. Inspector Notes from Inspection 9200 7/25/24 BUILER ASKED TO HAVE CULVERT PIPE ELEVATIONS CHECKED. 7/25/24 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/22/2024 Disapproved - NO FEE FSLADISH
Note: 7/22/24 CULVERT PIPES ARE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM ELEVATIONS 22.30-22.28 (22.45 SPD HIGH END), 22.27 FLAT (22.40 SPD LOW END). Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ELECTRIC - EARLY POWER 07/22/2024 APPROVED - AS NOTED KSANDOE
Note: Release Power 7/15/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2170 2/5/24: FPL emailed to release power at @ 08:42.
ELECTRIC - EARLY POWER 07/15/2024 CANCELLED BY APPLICANT RMARTIN
Note: Inspector Notes from Inspection 2170 2/5/24: FPL emailed to release power at @ 08:42.
ROW- PRE-APRON (PRE-POUR) 06/25/2024 APPROVED - AS NOTED PFLANAGAN
Note: CONTRACTOR WAS ON SITE FIXING FORMS ON THE MITER ENDS DO TO CULVERT PIPE MOVING PASSING AS NOTED THAT THIS IS BEING DONE AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. 6/24/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW- PRE-APRON (PRE-POUR) 06/24/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE RIGHT CULVERT PIPE ON THE LEFT SIDE IS TO FAR FROM EDGE OF PAVEMENT STILL. PLEASE SEE CITY OF PALM COAST RESIDENT SWALE PROFILE DRAWIN #300.D 2) WITH THE RAIN OVER THE WEEKEND THE SOIL IS TOO SOFT NEED TO COMPACT SOIL MORE. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------- 6/21/2024 - PREVIOUS INSPECTION NOTES THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW- PRE-APRON (PRE-POUR) 06/21/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE RIGHT CULVERT LEFT SIDE OF CULVERT IS TO FAR FROM THE EDGE OF PAVEMENT NEED TO BE NO MORE THAN 8' FROM THE EDGE OF ROAD
ROW- PRE-APRON (PRE-POUR) 06/20/2024 CANCELLED BY APPLICANT WEB
U - SEWER TIE IN 06/17/2024 APPROVED - AS NOTED MGIBSON
Note: 6/12/2024 - PREVIOUS INSPECTION NOTES PLUMBING CONTRACTOR NEEDS TO GETWITH UTILITY TO LOWER PEP TANK TO MAKE SEWER TIE IN FOR LEFT SIDE. THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 06/12/2024 Disapproved - NO FEE MGIBSON
Note: PLUMBING CONTRACTOR NEEDS TO GETWITH UTILITY TO LOWER PEP TANK TO MAKE SEWER TIE IN FOR LEFT SIDE
GRAVITY SEWER TEST 06/12/2024 APPROVED - AS NOTED MGIBSON
Note: BOTH SIDES OF DUPLEX GRAVITY SEWER ARE APPROVED AND SEWER TIE IN ON RIDE SIDE OF DUPLEX, HOWEVER RIGHT SIDE NEEDS TO BE CONNECTED. SPOKETO PLUMBING CONTRACTOR ABOUT UTILITY LOWERING LEFT SIDE TO MAKE TIE IN
PEP TANK INSTALLATION REQUEST 05/16/2024 APPROVED CBOWERMASTER
INSULATION 05/16/2024 APPROVED BTAYLOR
Note: 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24: * Previously listed item 1 is not fully resolved. Plumbing stacks still have incomplete firestop at top plate penetration. ** Previously listed item 2 remains unresolved. Still marked on the stud with FS from previous inspection. 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: Both Units: 1). Incomplete firestop at Dryer exhaust pipes and plumbing stacks in garage 2). Missing firestop at top plate penetration next to dryer exhaust in Unit A. Inspector Notes from Inspection 2420 4/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS 4-23-24 1. Windows installed are not windows on product approval sheet. Need revision for windows installed. 2. Doors do not have approval numbers on them. Therefor can not verify if they are the proper doors on approval sheet. 3. Some windows do not open. 4. Windows missing screws. All will need to be checked. 5. Dryer duct is not sealed all the up to roof. 6. Missing nail plates for vents and dryer ducts. 7. A/C layout does not match energy cals. 5-9-24 1. Both units still missing screws in windows.
INSULATION 05/15/2024 Disapproved -FEE REQUIRED RSIMS
Note: 5/15/24: * Previously listed item 1 is not fully resolved. Plumbing stacks still have incomplete firestop at top plate penetration. ** Previously listed item 2 remains unresolved. Still marked on the stud with FS from previous inspection. 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: Both Units: 1). Incomplete firestop at Dryer exhaust pipes and plumbing stacks in garage 2). Missing firestop at top plate penetration next to dryer exhaust in Unit A. Inspector Notes from Inspection 2420 4/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS 4-23-24 1. Windows installed are not windows on product approval sheet. Need revision for windows installed. 2. Doors do not have approval numbers on them. Therefor can not verify if they are the proper doors on approval sheet. 3. Some windows do not open. 4. Windows missing screws. All will need to be checked. 5. Dryer duct is not sealed all the up to roof. 6. Missing nail plates for vents and dryer ducts. 7. A/C layout does not match energy cals. 5-9-24 1. Both units still missing screws in windows.
INSULATION 05/14/2024 Disapproved - NO FEE RSIMS
Note: 5/14/24: Both Units: 1). Incomplete firestop at Dryer exhaust pipes and plumbing stacks in garage 2). Missing firestop at top plate penetration next to dryer exhaust in Unit A. Inspector Notes from Inspection 2420 4/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS 4-23-24 1. Windows installed are not windows on product approval sheet. Need revision for windows installed. 2. Doors do not have approval numbers on them. Therefor can not verify if they are the proper doors on approval sheet. 3. Some windows do not open. 4. Windows missing screws. All will need to be checked. 5. Dryer duct is not sealed all the up to roof. 6. Missing nail plates for vents and dryer ducts. 7. A/C layout does not match energy cals. 5-9-24 1. Both units still missing screws in windows.
ALL ROUGH 05/09/2024 APPROVED - AS NOTED BTAYLOR
Note: 4/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS 4-23-24 1. Windows installed are not windows on product approval sheet. Need revision for windows installed. 2. Doors do not have approval numbers on them. Therefor can not verify if they are the proper doors on approval sheet. 3. Some windows do not open. 4. Windows missing screws. All will need to be checked. 5. Dryer duct is not sealed all the up to roof. 6. Missing nail plates for vents and dryer ducts. 7. A/C layout does not match energy cals. 5-9-24 1. Both units still missing screws in windows.
ALL ROUGH 04/23/2024 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS 4-23-24 1. Windows installed are not windows on product approval sheet. Need revision for windows installed. 2. Doors do not have approval numbers on them. Therefor can not verify if they are the proper doors on approval sheet. 3. Some windows do not open. 4. Windows missing screws. All will need to be checked. 5. Dryer duct is not sealed all the up to roof. 6. Missing nail plates for vents and dryer ducts. 7. A/C layout does not match energy cals.
LATH/BRICK/ WATER BARRIER 04/22/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2443 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
FIREWALL DRYWALL NAILING 04/16/2024 APPROVED - AS NOTED RSIMS
Note: 4/16/24: Please do not cover screws prior to this inspection. This includes the field screws. New inspection due to canceled inspection 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
FIREWALL DRYWALL NAILING 04/12/2024 CANCELLED BY APPLICANT WEB
Note: 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
FIREWALL DRYWALL NAILING 04/08/2024 CANCELLED BY APPLICANT RSIMS
Note: 4/8/24: Cancelled by Applicant via text at @ 09:53. Inspector Notes from Inspection 2467 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
ROOF VALLEY & METAL 03/28/2024 APPROVED - AS NOTED RSIMS
Note: 3/28/24: Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 3/22/2024 - PREVIOUS INSPECTION NOTES No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
ROOF VALLEY & METAL 03/22/2024 Disapproved -FEE REQUIRED KSANDOE
Note: No valley metal, drip edge or underlayment installed. WALK YOUR JOB PRIOR TO SCHEDULING INSPECTIONS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/14/2024 APPROVED BTAYLOR
Note: 3/11/2024 - PREVIOUS INSPECTION NOTES 3-11-24 1. Bearing wall is not strapped per detail. 2. Trusses to bearing wall have wrong straps. Either need revision for straps used or put correct straps on.
WALL SHEATHING 03/11/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/11/2024 Disapproved - NO FEE BTAYLOR
Note: 3-11-24 1. Bearing wall is not strapped per detail. 2. Trusses to bearing wall have wrong straps. Either need revision for straps used or put correct straps on.
MONOLITHIC SLAB 03/08/2024 APPROVED BTAYLOR
Note: 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24: The revision that was submitted on 3/4/24 has only been Accepted not Approved yet and it appears to be missing the revised prints. Also, the slab was poured previously and the house has the cinderblock walls & framing/trusses/roof deck are complete already. 2/2/2024 - PREVIOUS INSPECTION NOTES 2/2/24: * Need revision for Engineer's letter allowing for Fiberglass reinforced concrete in lieu of wire mesh as shown on plans. Along with continuous slab thickness. Slab thickness is only shown at the load bearing footers.
MONOLITHIC SLAB 03/05/2024 Disapproved - NO FEE RSIMS
Note: 3/5/24: The revision that was submitted on 3/4/24 has only been Accepted not Approved yet and it appears to be missing the revised prints. Also, the slab was poured previously and the house has the cinderblock walls & framing/trusses/roof deck are complete already. 2/2/2024 - PREVIOUS INSPECTION NOTES 2/2/24: * Need revision for Engineer's letter allowing for Fiberglass reinforced concrete in lieu of wire mesh as shown on plans. Along with continuous slab thickness. Slab thickness is only shown at the load bearing footers.
FOUND SURVEY APPROVED (OFFICE) 02/22/2024 APPROVED TBAKER
TIE BEAM / LINTEL 02/09/2024 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2250 Spoke with RMartin and DBO reguarding revisions noted below. Inspection resulted as noted 2/2/24: * Need revision for Engineer's letter allowing for Fiberglass reinforced concrete in lieu of wire mesh as shown on plans. Along with continuous slab thickness. Slab thickness is only shown at the load bearing footers.
ELECTRIC TEMP POLE 02/05/2024 APPROVED - AS NOTED RSIMS
Note: 2/5/24: FPL emailed to release power at @ 08:42.
MONOLITHIC SLAB 02/02/2024 APPROVED - AS NOTED RSIMS
Note: Spoke with RMartin and DBO reguarding revisions noted below. Inspection resulted as noted 2/2/24: * Need revision for Engineer's letter allowing for Fiberglass reinforced concrete in lieu of wire mesh as shown on plans. Along with continuous slab thickness. Slab thickness is only shown at the load bearing footers.
PLUMBING 1ST ROUGH UNDERGROUND 01/31/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/11/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
MECH COMPLETE 05/06/2024 05/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/30/2024 05/03/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a master permit. Provide only duct layout and heatload as separate files
BLD COMPLETE 04/04/2024 04/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/05/2024 03/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/22/2024 02/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/22/2024 02/22/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
MECH COMPLETE 12/14/2023 12/14/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/14/2023 12/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 12/14/2023 12/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/14/2023 12/14/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 12/14/2023 01/31/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
CUSVC COMPLETE 12/04/2023 12/07/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
GAS CANCEL 12/04/2023 12/05/2023
LOCATE COMPLETE 12/04/2023 12/05/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 12/04/2023 12/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
SW1 COMPLETE 12/04/2023 12/13/2023
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ZON HOLD 12/04/2023 12/05/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan : missing width of the walkway.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/23/2024
REINSPECTION RESIDENTIAL ¤40.00 08/23/2024
REINSPECTION RESIDENTIAL ¤40.00 08/23/2024
REINSPECTION RESIDENTIAL ¤40.00 08/23/2024
CONTRACTOR CHANGE ¤20.00 08/23/2024
SW ENG REINSPECTION 20 ¤20.00 08/23/2024
SW ENG REINSPECTION 30 ¤30.00 08/23/2024
SW ENG REINSPECTION 30 ¤30.00 08/23/2024
SW ENG - REVIEW 20 ¤20.00 12/19/2023
SW ENG RES REVIEW 200 ¤200.00 12/19/2023
SEWER CREDIT (¤1,700.00) 12/19/2023
SEWER INSPECTION ¤25.00 12/19/2023
SEWER CAPITAL FACILITY ¤10,882.06 12/19/2023
WATER CAPITAL FACILITY FEE ¤7,989.02 12/19/2023
SITE PLAN 30 ¤30.00 12/19/2023
FC IMPACT FEE EMS ¤124.00 12/19/2023
IMPACT FEE FIRE ¤856.18 12/19/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 12/19/2023
FC IMPACT FEE LIBRARY ¤536.00 12/19/2023
IMPACT FEE PARKS ¤3,600.18 12/19/2023
IMPACT FEE SCHOOL ¤10,900.00 12/19/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 12/19/2023
WATER -IRRIGATION INSPECTION ¤50.00 12/19/2023
SURCHARGE FS 533.721 ¤5.11 12/19/2023
SURCHARGE - FS 468.631 ¤7.67 12/19/2023
SW ENG - FOUNDATION SURVEY ¤20.00 12/19/2023
SW ENG INSPECTION 80 ¤80.00 12/19/2023
SW ENG PRE APRON ¤30.00 12/19/2023
CONNECTION FEES ¤2,374.52 12/19/2023
WATER- TURN ON ¤50.00 12/19/2023
ADJUSTMENT 50% (¤511.13) 12/19/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/19/2023
INSPECTION - RESIDENTIAL ¤866.25 12/19/2023
PLAN REVIEW - APPROVED MASTER ¤126.00 12/19/2023
Fees Total Due: ¤0.00 Total Paid: ¤40,091.36