Permit #2023120164

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7034-00650-0100
Block: 00650
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-931-1183
Location Address: 29 ELIAS LN
Type: PO - POOL
Issue Date: 12/21/2023
NOC: RECORDED
Applicant name: JASON EUGENE SLESSER
Owner: WILTFONG KRISTOPHER & MEGAN WILTFONG H&W

Address

29 ELIAS LANE

PALM COAST, FL 32164

Lot: 0100
Contracted Stated Job Value: ¤49,589.00
Job Description: POOL AND SCREEN
Type: CN

Contractor

SLESSER CUSTOM POOLS AND SPAS, INC
Status Location Address State License Number Phone
ACTIVE

P. O. Box 2595

Bunnell, 32110

CPC1456546 (Exp: 08/31/2026) 386-931-1183

Sub Contractors

CHRISTOPHER I HALL
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 2413

Bunnell, FL 32110

EC13002161 (Exp: 08/31/2028) (386) 437-2966 386-437-5042
RICHARD SWAN TOWNSEND II
Status Location Address State License Number Phone
ACTIVE

3111 OPPORTUNITY CT SUITE D

PORT ORANGE, FL 32129

CGC1515792 (Exp: 08/31/2026) 386-756-8770

Inspection History

Type Request Date Result Inspector
POOL FINAL 07/30/2024 Disapproved - NO FEE AGAETANO
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required. 07-30-2024 Rang door bell and knocked on the door twice. Need access for inspection. If homeowner is not home please leave the gate and screen door in a propped open position.
POOL FINAL 07/30/2024 FINAL APPROVED BTAYLOR
Note: 7/30/2024 - PREVIOUS INSPECTION NOTES 7/18/2024 - PREVIOUS INSPECTION NOTES 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required. 07-30-2024 Rang door bell and knocked on the door twice. Need access for inspection. If homeowner is not home please leave the gate and screen door in a propped open position.
POOL FINAL 07/18/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required.
POOL FINAL 07/09/2024 Disapproved - NO FEE RSIMS
Note: 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. 2). Screen enclosure is not grounded as required.
ROW - FINAL INSPECTION 07/03/2024 APPROVED - AS NOTED PFLANAGAN
Note: POOL COMPANY PUT A UNDER DRIAN FOR THE WATER AND PIPED THE GUTTERS TO THE DRAIN. PASSING AS NOTED THAT THE RESIDENT WAS HAPPY WITH THE JOB. ITS IS BETWEEN THE HOMEOWNER AND THE POOL BUILDER IF ANYTHING AFTER THIS INSPECTION IS WRONG. CANT TELL IF THE DRAIN WILL WORK AT THIS TIME DO TO NO RAIN SINCE DRAIN PUT IN. ------------------------------------------------------------------------------- 6/27/2024 - PREVIOUS INSPECTION NOTES MEET WITH HOMEOWNER ON THE DRAINAGE OF THE LOT AND DECK PER PARREN AND GABE POOL COMPANY NEEDS TO PUT A SWALE AGAINST THE ROCK THAT IS 5" DEEP WITH NO SOD AND 3" WITH SOD THEN MAKE IT GO AROUND THE RIGHT SIDE OF THE HOUSE SO THE DECK DOESN'T FLOOD DURING RAIN. PLEASE SEE PHOTOS ON THIS INSPECTION. -------------------------------------------------------------------------------- 6/26/2024 - PREVIOUS INSPECTION NOTES ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM.
ROW - FINAL INSPECTION 06/27/2024 Disapproved - NO FEE PFLANAGAN
Note: MEET WITH HOMEOWNER ON THE DRAINAGE OF THE LOT AND DECK PER PARREN AND GABE POOL COMPANY NEEDS TO PUT A SWALE AGAINST THE ROCK THAT IS 5" DEEP WITH NO SOD AND 3" WITH SOD THEN MAKE IT GO AROUND THE RIGHT SIDE OF THE HOUSE SO THE DECK DOESN'T FLOOD DURING RAIN. PLEASE SEE PHOTOS ON THIS INSPECTION. -------------------------------------------------------------------------------- 6/26/2024 - PREVIOUS INSPECTION NOTES ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM.
ROW - FINAL INSPECTION 06/26/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM.
U -UTILITY RESIDENTIAL FINAL 06/26/2024 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/25/2024 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 06/25/2024 APPROVED PFLANAGAN
ELECTRIC AND ALARM 04/19/2024 APPROVED - AS NOTED RSIMS
Note: 4/19/24: * Note: Pool gas heater will need the 4 Florida Approved anchors as required. (M1307.2/M1401.1) prior to Pool Final Inspection.
POOL DECK 03/13/2024 APPROVED MKRASKI
POOL DECK 03/06/2024 Disapproved - NO FEE RSIMS
Note: 3/6/24: * Footer does not match required details on Screen enclosure plans.
STEEL AND GROUND 01/24/2024 APPROVED RSIMS
Note: 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24: * Pressure on replaced gauge was only at <25 PSI at the time of inspection. Please increase presure to 35PSI for inspection as required. 1/22/2024 - PREVIOUS INSPECTION NOTES Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35.
STEEL AND GROUND 01/23/2024 Disapproved - NO FEE RSIMS
Note: 1/23/24: * Pressure on replaced gauge was only at <25 PSI at the time of inspection. Please increase presure to 35PSI for inspection as required. 1/22/2024 - PREVIOUS INSPECTION NOTES Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35.
STEEL AND GROUND 01/22/2024 Disapproved - NO FEE JWALKER
Note: Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35.

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/12/2023 12/19/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 12/12/2023 12/12/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2023 12/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 12/05/2023 12/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/05/2023 12/06/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 12/05/2023 12/07/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE FLOW ARROWS TO SHOW DRAINAGE OF THE LOT
ZON COMPLETE 12/05/2023 12/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 07/29/2024
SW ENG REINSPECTION 20 ¤20.00 07/08/2024
SW ENG - REVIEW 20 ¤20.00 12/21/2023
SITE PLAN 30 ¤30.00 12/21/2023
SURCHARGE FS 533.721 ¤2.00 12/21/2023
SURCHARGE - FS 468.631 ¤2.00 12/21/2023
SW ENG INSPECTION 40 ¤40.00 12/21/2023
ADJUSTMENT 50% (¤127.50) 12/21/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/21/2023
INSPECTION- POOL ¤160.00 12/21/2023
PLAN REVIEW - RESIDENTIAL ¤65.00 12/21/2023
Fees Total Due: ¤0.00 Total Paid: ¤281.50