I want to search for...
Permit #2023120164
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00650-0100 |
| Block: 00650 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-931-1183 |
| Location Address: 29 ELIAS LN |
| Type: PO - POOL |
| Issue Date: 12/21/2023 |
| NOC: RECORDED |
| Applicant name: JASON EUGENE SLESSER |
| Owner: WILTFONG KRISTOPHER & MEGAN WILTFONG H&W |
|
Address 29 ELIAS LANE PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤49,589.00 |
| Job Description: POOL AND SCREEN |
| Type: CN |
Contractor
SLESSER CUSTOM POOLS AND SPAS, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 2595 Bunnell, 32110 |
CPC1456546 (Exp: 08/31/2026) | 386-931-1183 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
RICHARD SWAN TOWNSEND II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3111 OPPORTUNITY CT SUITE D PORT ORANGE, FL 32129 |
CGC1515792 (Exp: 08/31/2026) | 386-756-8770 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 07/30/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 7/18/2024 - PREVIOUS INSPECTION NOTES 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required. 07-30-2024 Rang door bell and knocked on the door twice. Need access for inspection. If homeowner is not home please leave the gate and screen door in a propped open position. | |||
| POOL FINAL | 07/30/2024 | FINAL APPROVED | BTAYLOR |
| Note: 7/30/2024 - PREVIOUS INSPECTION NOTES 7/18/2024 - PREVIOUS INSPECTION NOTES 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required. 07-30-2024 Rang door bell and knocked on the door twice. Need access for inspection. If homeowner is not home please leave the gate and screen door in a propped open position. | |||
| POOL FINAL | 07/18/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/18/24: * Previously listed item 1 is still not resolved. It remains anchored at only 2 points in the front as shown in the picture left on top of the unit. M1401.1 requires anchoring at 4 points. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. M1401.1 2). Screen enclosure is not grounded as required. | |||
| POOL FINAL | 07/09/2024 | Disapproved - NO FEE | RSIMS |
| Note: 7/9/24: 1). Pool heater is not anchored to pad at four locations as required. 2). Screen enclosure is not grounded as required. | |||
| ROW - FINAL INSPECTION | 07/03/2024 | APPROVED - AS NOTED | PFLANAGAN |
| Note: POOL COMPANY PUT A UNDER DRIAN FOR THE WATER AND PIPED THE GUTTERS TO THE DRAIN. PASSING AS NOTED THAT THE RESIDENT WAS HAPPY WITH THE JOB. ITS IS BETWEEN THE HOMEOWNER AND THE POOL BUILDER IF ANYTHING AFTER THIS INSPECTION IS WRONG. CANT TELL IF THE DRAIN WILL WORK AT THIS TIME DO TO NO RAIN SINCE DRAIN PUT IN. ------------------------------------------------------------------------------- 6/27/2024 - PREVIOUS INSPECTION NOTES MEET WITH HOMEOWNER ON THE DRAINAGE OF THE LOT AND DECK PER PARREN AND GABE POOL COMPANY NEEDS TO PUT A SWALE AGAINST THE ROCK THAT IS 5" DEEP WITH NO SOD AND 3" WITH SOD THEN MAKE IT GO AROUND THE RIGHT SIDE OF THE HOUSE SO THE DECK DOESN'T FLOOD DURING RAIN. PLEASE SEE PHOTOS ON THIS INSPECTION. -------------------------------------------------------------------------------- 6/26/2024 - PREVIOUS INSPECTION NOTES ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM. | |||
| ROW - FINAL INSPECTION | 06/27/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: MEET WITH HOMEOWNER ON THE DRAINAGE OF THE LOT AND DECK PER PARREN AND GABE POOL COMPANY NEEDS TO PUT A SWALE AGAINST THE ROCK THAT IS 5" DEEP WITH NO SOD AND 3" WITH SOD THEN MAKE IT GO AROUND THE RIGHT SIDE OF THE HOUSE SO THE DECK DOESN'T FLOOD DURING RAIN. PLEASE SEE PHOTOS ON THIS INSPECTION. -------------------------------------------------------------------------------- 6/26/2024 - PREVIOUS INSPECTION NOTES ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM. | |||
| ROW - FINAL INSPECTION | 06/26/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: ALL SOD THAT WAS PUT IN THE RIGHT OF WAY / ROADSIDE SWALE IS HIGHER THAN THE SURROUNDING SOD. NEED TO LOWER SOD SO THE WATER WILL FLOW TO OUTFALL AND NOT HOLD WATER UP UPSTREAM. | |||
| U -UTILITY RESIDENTIAL FINAL | 06/26/2024 | FINAL APPROVED | BWRIGHT |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/25/2024 | APPROVED | PFLANAGAN |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/25/2024 | APPROVED | PFLANAGAN |
| ELECTRIC AND ALARM | 04/19/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/19/24: * Note: Pool gas heater will need the 4 Florida Approved anchors as required. (M1307.2/M1401.1) prior to Pool Final Inspection. | |||
| POOL DECK | 03/13/2024 | APPROVED | MKRASKI |
| POOL DECK | 03/06/2024 | Disapproved - NO FEE | RSIMS |
| Note: 3/6/24: * Footer does not match required details on Screen enclosure plans. | |||
| STEEL AND GROUND | 01/24/2024 | APPROVED | RSIMS |
| Note: 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24: * Pressure on replaced gauge was only at <25 PSI at the time of inspection. Please increase presure to 35PSI for inspection as required. 1/22/2024 - PREVIOUS INSPECTION NOTES Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35. | |||
| STEEL AND GROUND | 01/23/2024 | Disapproved - NO FEE | RSIMS |
| Note: 1/23/24: * Pressure on replaced gauge was only at <25 PSI at the time of inspection. Please increase presure to 35PSI for inspection as required. 1/22/2024 - PREVIOUS INSPECTION NOTES Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35. | |||
| STEEL AND GROUND | 01/22/2024 | Disapproved - NO FEE | JWALKER |
| Note: Deep end main drain piping not under test. Opened spigot valve to release pressure. The pressure guage did not move and is stuck in place at appx 50 psi. Please place the piping under static or pressure test. Ensure gauge is working correctly. Minimum PSI is to be 35. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 12/12/2023 | 12/19/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/12/2023 | 12/12/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2023 | 12/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/05/2023 | 12/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/05/2023 | 12/06/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/05/2023 | 12/07/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE FLOW ARROWS TO SHOW DRAINAGE OF THE LOT | |||
| ZON | COMPLETE | 12/05/2023 | 12/06/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/29/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/08/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/21/2023 |
| SITE PLAN 30 | ¤30.00 | 12/21/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/21/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/21/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 12/21/2023 |
| ADJUSTMENT 50% | (¤127.50) | 12/21/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/21/2023 |
| INSPECTION- POOL | ¤160.00 | 12/21/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 12/21/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤281.50 |