Permit #2023120184
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-01240-0120 |
| CONDITIONED SPACE: 598 sqft |
| Total Square Footage: 598 sqft |
| Block: 01240 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-313-6922 |
| Location Address: 5 EDGAR LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 12/27/2023 |
| NOC: RECORDED |
| Applicant name: FRANK JOSEPH WHALEN |
| Owner: HOLBERT KIM LESLIE & KEITH WILLIAM |
|
Address 16048 BIRWOOD AVENUE BEVERLY HILL, MI 48025 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤189,300.00 |
| Job Description: Master Suite Addition |
| Type: CN |
Contractor
EAST COAST BUILDING CORP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
321 BRIARWOOD DRIVE BUNNELL, FL 32110 |
CGC057860 (Exp: 08/31/2026) | 386-313-6922 | 386-313-6922 |
Sub Contractors
MICHAEL MATTHEW SANKOSWSKI
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3 SEAMANSHIP TRAIL PALM COAST, FL 32164 |
CAC1818816 (Exp: 08/31/2026) | 386-316-4401 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TIMOTHY SCOTT CONLAN
| Status | Location Address | State License Number | Phone |
| INACTIVE |
800 BELLFORT PARKWAY #200 , FL 0 |
CCC1334753 (Exp: 08/31/2026) | 904-515-6889 |
ROBERT CARLTON LITTLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3050 EAST MOODY BLVD BUNNELL, FL 32110 |
EC13003740 (Exp: 08/31/2026) | 386-931-1708 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 11/13/2024 | APPROVED | FSLADISH |
| Note: 11/4/2024 - PREVIOUS INSPECTION NOTES 10/31/24 TPOLACEK*** INSPECTOR NOTE*** ROADSIDE SWALE MUST HAVE ALL BARE EARTH COVERED WITH SOD THAT MATCHES EXISTING ELEVATION BEFORE SCHEDULING ROW FINAL 4. The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage. | |||
| BLD - BUILDING FINAL | 11/06/2024 | FINAL APPROVED | PKNAPIK |
| Note: 11/4/2024 - PREVIOUS INSPECTION NOTES 11/04/24 please identified breakers on electrical panel for new AC & Heat unit / please mark old unit brakers for info | |||
| U -UTILITY RESIDENTIAL FINAL | 11/04/2024 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL INSPECTION | 11/04/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 10/31/24 TPOLACEK*** INSPECTOR NOTE*** ROADSIDE SWALE MUST HAVE ALL BARE EARTH COVERED WITH SOD THAT MATCHES EXISTING ELEVATION BEFORE SCHEDULING ROW FINAL 4. The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage. | |||
| BLD - BUILDING FINAL | 11/04/2024 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: 11/04/24 please identified breakers on electrical panel for new AC & Heat unit / please mark old unit brakers for info | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/31/2024 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/31/2024 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| INSULATION | 04/11/2024 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2420 4/8/24: Check at next inspection. Must be complete prior to Insualtion inspection. 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: 1). Plans missing electrical page. 2). No 5ft. head pressure 3). No gauge on water supplies. 4). Front window is missing one anchor. | |||
| ALL ROUGH | 04/08/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/8/24: 1). Plans missing electrical page. 2). No 5ft. head pressure 3). No gauge on water supplies. 4). Front window is missing one anchor. | |||
| ALL ROUGH | 04/08/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 4/8/24: Check at next inspection. Must be complete prior to Insualtion inspection. 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: 1). Plans missing electrical page. 2). No 5ft. head pressure 3). No gauge on water supplies. 4). Front window is missing one anchor. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/05/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 3/28/2024 - PREVIOUS INSPECTION NOTES 3/28/24: * Missing brackets at the top of the joists above the bathroom area as required on the plan. * Will need an engineer's letter submitted to and approved by the City for the four altered truss repairs. Inspector Notes from Inspection 2467 3/20/24: Inspection added to check RVM on existing roof replacement as well as new roof areas. Approved as noted for confirmation of resolution of previous note on 3/15/24: Repair * Note: Need to check that 5" x 5" flashing is sealed properly to the wall as required during the 2nd part of the 2460 RS/B/T/DC inspection. Approved as noted during RVM inspection so that contractor could get the existing & new roof water tight. Inspector Notes from Inspection 2465 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/05/2024 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection 3/28/2024 - PREVIOUS INSPECTION NOTES 3/28/24: * Missing brackets at the top of the joists above the bathroom area as required on the plan. * Will need an engineer's letter submitted to and approved by the City for the four altered truss repairs. Inspector Notes from Inspection 2467 3/20/24: Inspection added to check RVM on existing roof replacement as well as new roof areas. Approved as noted for confirmation of resolution of previous note on 3/15/24: Repair * Note: Need to check that 5" x 5" flashing is sealed properly to the wall as required during the 2nd part of the 2460 RS/B/T/DC inspection. Approved as noted during RVM inspection so that contractor could get the existing & new roof water tight. Inspector Notes from Inspection 2465 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/28/2024 | Disapproved - NO FEE | RSIMS |
| Note: 3/28/24: * Missing brackets at the top of the joists above the bathroom area as required on the plan. * Will need an engineer's letter submitted to and approved by the City for the four altered truss repairs. Inspector Notes from Inspection 2467 3/20/24: Inspection added to check RVM on existing roof replacement as well as new roof areas. Approved as noted for confirmation of resolution of previous note on 3/15/24: Repair * Note: Need to check that 5" x 5" flashing is sealed properly to the wall as required during the 2nd part of the 2460 RS/B/T/DC inspection. Approved as noted during RVM inspection so that contractor could get the existing & new roof water tight. Inspector Notes from Inspection 2465 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF VALLEY & METAL | 03/20/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 3/20/24: Inspection added to check RVM on existing roof replacement as well as new roof areas. Approved as noted for confirmation of resolution of previous note on 3/15/24: Repair * Note: Need to check that 5" x 5" flashing is sealed properly to the wall as required during the 2nd part of the 2460 RS/B/T/DC inspection. Approved as noted during RVM inspection so that contractor could get the existing & new roof water tight. Inspector Notes from Inspection 2465 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/20/2024 | PARTIALLY APPROVED | RSIMS |
| Note: 3/20/24: Partial approval for confirmation of resolution of previous note on 3/15/24: Repair Approved. * Note: Need to check that 5" x 5" flashing is sealed properly to the wall as required during the 2nd part of this inspection. Approved as noted during RVM inspection so that contractor could get the existing & new roof water tight. Inspector Notes from Inspection 2465 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF SHEATHING | 03/15/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at Inspection 2460 (RS/B/T/DC). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/15/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 2/27/2024 - PREVIOUS INSPECTION NOTES 2/27/24: Wrong inspection called in. Added tie beam/lintel inspection as required and scheduled/resulted today. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/15/2024 | Disapproved - NO FEE | RSIMS |
| Note: 3/15/24: Gable on right side of entry above existing window: Need to replace a small section of rotted plywood along with the sub-fascia (2x) that has some rotted sections. Check at re-inspection. * All of the new roof sheathing inspected and approved during inspection 2465 (Roof Sheathing) Contractor approved to cover all but the small existing area noted above. New inspection due to canceled inspection 2/27/2024 - PREVIOUS INSPECTION NOTES 2/27/24: Wrong inspection called in. Added tie beam/lintel inspection as required and scheduled/resulted today. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/27/2024 | Disapproved - NO FEE | RSIMS |
| Note: 2/27/24: Wrong inspection called in. Added tie beam/lintel inspection as required and scheduled/resulted today. | |||
| TIE BEAM / LINTEL | 02/27/2024 | APPROVED | RSIMS |
| MONOLITHIC SLAB | 02/12/2024 | APPROVED | RSIMS |
| Note: 2/9/2024 - PREVIOUS INSPECTION NOTES 2-9-24 Still need releieving arch or sleeve per prior notes and P2603.4 2/8/2024 - PREVIOUS INSPECTION NOTES 1. Water line going through footing requires a sleeve thats 2 trade sizes larger or releaving archs 2. Footing is not per detail 3. Must have approved plans with stamp from Building Dept. before reinspection | |||
| MONOLITHIC SLAB | 02/09/2024 | Disapproved - NO FEE | LMILLER |
| Note: 2-9-24 Still need releieving arch or sleeve per prior notes and P2603.4 2/8/2024 - PREVIOUS INSPECTION NOTES 1. Water line going through footing requires a sleeve thats 2 trade sizes larger or releaving archs 2. Footing is not per detail 3. Must have approved plans with stamp from Building Dept. before reinspection | |||
| MONOLITHIC SLAB | 02/08/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Water line going through footing requires a sleeve thats 2 trade sizes larger or releaving archs 2. Footing is not per detail 3. Must have approved plans with stamp from Building Dept. before reinspection | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/05/2024 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/03/2024 | 04/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/03/2024 | 04/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/01/2024 | 04/02/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter needs to be digitally signed and sealed. | |||
| ENGIN1 | COMPLETE | 02/20/2024 | 02/20/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/20/2024 | 02/20/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/19/2023 | 12/19/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/19/2023 | 12/27/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/19/2023 | 12/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/19/2023 | 12/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/06/2023 | 12/13/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 12/06/2023 | 12/11/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit manufacture specs for generator. 2. Submit a riser diagram that includes all wire sizes and breaker sizes for the generator. 3. Electrical page shows new panel in shed. Need to show wire sizes and what the panel is for and now house circuits can be located in the panel. | |||
| GAS | CANCEL | 12/06/2023 | 12/06/2023 |
| MECH | HOLD | 12/06/2023 | 12/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| PLUM | COMPLETE | 12/06/2023 | 12/13/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/06/2023 | 12/14/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM BUILDER NEED The subject lots drainage must not negatively impact any adjacent property. (B) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)?Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) FINAL SURVEY NEED IT AFTER THE CONSTRUCTION | |||
| ZON | HOLD | 12/06/2023 | 12/06/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Plans need to be consistant. Color sheet: Proposes a shingle roof but the elevation page and roofing work sheet proposes metal roof. Please make all plans match. Floor plan: Office not allowed as per LDC please rename the room to study or den. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 11/01/2024 |
| ADJUSTMENT 50% | (¤350.35) | 12/27/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/27/2023 |
| INSPECTION - RESIDENTIAL | ¤522.50 | 12/27/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤148.20 | 12/27/2023 |
| SURCHARGE FS 533.721 | ¤3.50 | 12/27/2023 |
| SURCHARGE - FS 468.631 | ¤5.26 | 12/27/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/27/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/27/2023 |
| SITE PLAN 30 | ¤30.00 | 12/27/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤469.11 |