I want to search for...
Permit #2023120469
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00100-0350 |
| CONDITIONED SPACE: 1867 sqft |
| GARAGE: 409 sqft |
| OPENED PORCH (WITH ROOF) : 28 sqft |
| Total Square Footage: 2304 sqft |
| Block: 00100 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 904-268-7730 |
| Location Address: 41 PEBBLE BEACH DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/22/2023 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES, LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
JAMES M GREENSLADE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
311 S BAY ST BUNNELL, FL 32110 |
EC13006083 (Exp: 08/31/2026) | 386-263-2960 | 386-263-2980 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
SCOTT CHRISTIAN HOWARD
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/21/2024 | FINAL APPROVED | MKRASKI |
| Note: | |||
| BLD - BUILDING FINAL | 05/20/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/20/24: 1). 1 of 3 Locking port caps is not locked. M1411.8 2). Range anti-tip device is missing 1 of 2 anchors into the wall base plate or concrete slab as required by the Manufacturer. M1307.1 2). Dishwasher drain is not installed as required. P2717.2 dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece. 3). Dryer gooseneck is missing the self closing damper. M1502.3 4). Shingle at Laundry vent stack is damaged and needs to be replaced. 5). Kitchen exhaust is missing the 3 screws at each joint as required. M1601.4.1 | |||
| U -UTILITY RESIDENTIAL FINAL | 05/20/2024 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/13/2024 11:31:19 AM *** no irrigation-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 05/17/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/17/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE TO SURVEY -------------------------------------------------------------- 5/16/2024 - PREVIOUS INSPECTION NOTES 05/16/24 TPOLACEK*** FFE IS NOW GOOD. HOWEVER, THERE IS STILL A CONFLICT WITH THE 10' OFFSET ON THE LEFT SIDE ADJACENT PROPERTY. SURVEY STILL INDICATES A 9' HIGH RISE IN ELEVATION BETWEEN THE TWO PROPERTIES. LEFT SIDE FFE IS 26.57 THE OFFSET STATES 35.84 (ALMOST10') SUBJECT LOT FFE IS 26.84. PLEASE MAKE CORRECTIONS TO SURVEY AS THE ENTIRE 10' OFFSET HAS EXTREME ELEVATION CHANGES AS NOTED IN PREVIOUS INSPECTION ________________________________________________________________________________________________________________________ 5/14/2024 - PREVIOUS INSPECTION NOTES 05/14/24 Site plan indicates a FFE of 26.66 final survey indicates a 26.96 which is .30 higher than proposed. The city tolerance is .20, The rear yard elevationson the site plan indicate a .50 or more difference tolerance is .40. 10' offset on the left indicates a 9' high berm betweeen the homes that will shed water back and neg impact the subject lot. I would have survey company verify all elevations and resubmit a new survey. Inspector Notes from Inspection 9270 4/25/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/17/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - STORMWATER FINAL | 05/17/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/16/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/16/24 TPOLACEK*** FFE IS NOW GOOD. HOWEVER, THERE IS STILL A CONFLICT WITH THE 10' OFFSET ON THE LEFT SIDE ADJACENT PROPERTY. SURVEY STILL INDICATES A 9' HIGH RISE IN ELEVATION BETWEEN THE TWO PROPERTIES. LEFT SIDE FFE IS 26.57 THE OFFSET STATES 35.84 (ALMOST10') SUBJECT LOT FFE IS 26.84. PLEASE MAKE CORRECTIONS TO SURVEY AS THE ENTIRE 10' OFFSET HAS EXTREME ELEVATION CHANGES AS NOTED IN PREVIOUS INSPECTION ________________________________________________________________________________________________________________________ 5/14/2024 - PREVIOUS INSPECTION NOTES 05/14/24 Site plan indicates a FFE of 26.66 final survey indicates a 26.96 which is .30 higher than proposed. The city tolerance is .20, The rear yard elevationson the site plan indicate a .50 or more difference tolerance is .40. 10' offset on the left indicates a 9' high berm betweeen the homes that will shed water back and neg impact the subject lot. I would have survey company verify all elevations and resubmit a new survey. Inspector Notes from Inspection 9270 4/25/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/14/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 05/14/24 Site plan indicates a FFE of 26.66 final survey indicates a 26.96 which is .30 higher than proposed. The city tolerance is .20, The rear yard elevationson the site plan indicate a .50 or more difference tolerance is .40. 10' offset on the left indicates a 9' high berm betweeen the homes that will shed water back and neg impact the subject lot. I would have survey company verify all elevations and resubmit a new survey. Inspector Notes from Inspection 9270 4/25/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U-CROSS CONNECTION | 05/13/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 5/13/2024 11:31:19 AM *** no irrigation-no cross connection | |||
| ROW- PRE-APRON (PRE-POUR) | 04/25/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/25/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ELECTRIC - EARLY POWER | 04/11/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Inspector Notes from Inspection 2200 FPL emailed at @08:50 - approved for TUG outlet. | |||
| SEWER TIE IN | 04/05/2024 | CANCELLED BY APPLICANT | WEB |
| SEWER TIE IN | 04/02/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 03/07/2024 | APPROVED | JSTEWART |
| LATH/BRICK/ WATER BARRIER | 03/05/2024 | APPROVED | MKRASKI |
| Note: | |||
| ALL ROUGH | 03/04/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 3/4/24- All Inspection tags for windows and SGD have been removed, please adhere to the window for inspection. Will check at Insulation. Inspector Notes from Inspection 2467 2/23/24 - STILL NOT RESOLVED. ROOF VALLEY PASSED. CHECK OTHER ITEM AT ALL ROUGH. Inspector Notes from Inspection 2460 2/16/24: This inspection is approved pending the revision being submitted & approved by the City for the GP01 - 3 ply truss at garage entry. as previously noted. Must be resolved by All Rough. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). There is only 1- GP01- 3ply truss. Truss packet indicates 2. Truss nails are covered on both sides so we are unable to verify the connecting nailing pattern meets required as stated on Truss packet. 3). (2) 3Ply Truss HGR07F - back one nails on bottom chord are not staggered as required. Both web members 4-17 & 9-13 nailing pattern does not meet required. Highlighted. | |||
| LATH/BRICK/ WATER BARRIER | 03/04/2024 | Disapproved - NO FEE | JSTEWART |
| Note: 3/4/24- Please install Water barrier (flashing) at front entry door margins. R703.4 (1) Flashing Please tape any and all damged wall sheathing, per Manufacturer specs. Inspector Notes from Inspection 2467 2/23/24 - STILL NOT RESOLVED. ROOF VALLEY PASSED. CHECK OTHER ITEM AT ALL ROUGH. Inspector Notes from Inspection 2460 2/16/24: This inspection is approved pending the revision being submitted & approved by the City for the GP01 - 3 ply truss at garage entry. as previously noted. Must be resolved by All Rough. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). There is only 1- GP01- 3ply truss. Truss packet indicates 2. Truss nails are covered on both sides so we are unable to verify the connecting nailing pattern meets required as stated on Truss packet. 3). (2) 3Ply Truss HGR07F - back one nails on bottom chord are not staggered as required. Both web members 4-17 & 9-13 nailing pattern does not meet required. Highlighted. | |||
| ROOF VALLEY & METAL | 02/23/2024 | APPROVED - AS NOTED | FWILLIS |
| Note: 2/23/24 - STILL NOT RESOLVED. ROOF VALLEY PASSED. CHECK OTHER ITEM AT ALL ROUGH. Inspector Notes from Inspection 2460 2/16/24: This inspection is approved pending the revision being submitted & approved by the City for the GP01 - 3 ply truss at garage entry. as previously noted. Must be resolved by All Rough. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). There is only 1- GP01- 3ply truss. Truss packet indicates 2. Truss nails are covered on both sides so we are unable to verify the connecting nailing pattern meets required as stated on Truss packet. 3). (2) 3Ply Truss HGR07F - back one nails on bottom chord are not staggered as required. Both web members 4-17 & 9-13 nailing pattern does not meet required. Highlighted. | |||
| ELECTRIC-TUG | 02/20/2024 | APPROVED - AS NOTED | RSIMS |
| Note: FPL emailed at @08:50 - approved for TUG outlet. | |||
| WALL SHEATHING | 02/16/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/16/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/16/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 2/16/24: This inspection is approved pending the revision being submitted & approved by the City for the GP01 - 3 ply truss at garage entry. as previously noted. Must be resolved by All Rough. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). There is only 1- GP01- 3ply truss. Truss packet indicates 2. Truss nails are covered on both sides so we are unable to verify the connecting nailing pattern meets required as stated on Truss packet. 3). (2) 3Ply Truss HGR07F - back one nails on bottom chord are not staggered as required. Both web members 4-17 & 9-13 nailing pattern does not meet required. Highlighted. | |||
| ROOF SHEATHING | 02/16/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/15/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). There is only 1- GP01- 3ply truss. Truss packet indicates 2. Truss nails are covered on both sides so we are unable to verify the connecting nailing pattern meets required as stated on Truss packet. 3). (2) 3Ply Truss HGR07F - back one nails on bottom chord are not staggered as required. Both web members 4-17 & 9-13 nailing pattern does not meet required. Highlighted. | |||
| ROOF SHEATHING | 02/13/2024 | APPROVED | FWILLIS |
| WALL SHEATHING | 02/13/2024 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 02/02/2024 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 02/01/2024 | APPROVED | JSTEWART |
| FOUND SURVEY APPROVED (OFFICE) | 01/30/2024 | APPROVED | TBAKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/30/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 01/30/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/11/2024 | APPROVED | BVITALE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/21/2024 | 02/27/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/15/2024 | 02/21/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Truss engineering page needs to have truss engineer's seal | |||
| ENGIN1 | COMPLETE | 01/30/2024 | 01/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/30/2024 | 01/30/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/08/2024 | 01/08/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/08/2024 | 01/08/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator | |||
| BADMIN | INFORMATION | 01/05/2024 | 01/05/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM a new permit application (signed and notarized) must be submitted with the new deed. | |||
| SWALE | COMPLETE | 12/13/2023 | 01/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/12/2023 | 12/19/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 12/12/2023 | 12/18/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/12/2023 | 12/14/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/12/2023 | 12/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/12/2023 | 12/13/2023 |
| LOCATE | COMPLETE | 12/12/2023 | 12/14/2023 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/12/2023 | 12/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/12/2023 | 12/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/12/2023 | 12/13/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 12/12/2023 | 12/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 05/21/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 05/21/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 05/21/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 05/21/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 05/21/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/21/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/21/2024 |
| CONNECTION FEES | ¤1,187.26 | 12/22/2023 |
| WATER- TURN ON | ¤25.00 | 12/22/2023 |
| ADJUSTMENT 50% | (¤611.57) | 12/22/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/22/2023 |
| INSPECTION - RESIDENTIAL | ¤929.50 | 12/22/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤263.64 | 12/22/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 12/22/2023 |
| IMPACT FEE FIRE | ¤428.09 | 12/22/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/22/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/22/2023 |
| IMPACT FEE PARKS | ¤1,800.99 | 12/22/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 12/22/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 12/22/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/22/2023 |
| SURCHARGE FS 533.721 | ¤6.12 | 12/22/2023 |
| SURCHARGE - FS 468.631 | ¤9.17 | 12/22/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/22/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/22/2023 |
| SW ENG PRE APRON | ¤30.00 | 12/22/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/22/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/22/2023 |
| SEWER CREDIT | (¤958.00) | 12/22/2023 |
| SEWER INSPECTION | ¤25.00 | 12/22/2023 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 12/22/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 12/22/2023 |
| SITE PLAN 30 | ¤30.00 | 12/22/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,965.74 |