I want to search for...
Permit #2023120504
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00410-0020 |
| CONDITIONED SPACE: 2586 sqft |
| GARAGE: 820 sqft |
| OPENED PORCH (WITH ROOF) : 300 sqft |
| OPENED PORCH (WITH ROOF) : 220 sqft |
| Total Square Footage: 3926 sqft |
| Block: 00410 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-569-7882 |
| Location Address: 6 EASTON PL |
| Type: DU - DUPLEX |
| Issue Date: 02/14/2024 |
| NOC: RECORDED |
| Applicant name: VLADIMIR V PEREPECHKIN |
| Owner: SHMAKOV ANDREY & LYUBOV H&W |
|
Address 17 ZEPHYR LILY PLACE PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤485,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
WISE CHOICE CUSTOM HOMES, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
77 SOUTHLAKE DR PALM COAST, FL 32137 |
CRC1328738 (Exp: 08/31/2026) | 386-569-7882 |
Sub Contractors
ANDREW GONCALVES HOWARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 RYALL LANE PALM COAST, FL 32164 |
CCC1333989 (Exp: 08/31/2026) | 386-347-0366 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 06/10/2026 | APPROVED - AS NOTED | BVEIGA |
| Note: NO/CC NO/IRR | |||
| BLD - BUILDING FINAL | 06/04/2026 | FINAL APPROVED | KSANDOE |
| Note: 6/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next final inspection #1-NEC Article 230.67 mandates the use of a Surge-Protective Device (SPD) for (A)all services supplying specific occupancies (B)Location.the SPD shall be an integral part of the service equipment or shall be located inmediately adjacent thereto. ( Unit A & B Meter base ) #2-NEC 210.8. This includes receptacles and hard-wired equipment like HVAC units. Weather-resistant (WR-rated) receptacles and in-use weatherproof covers are also required. Exterior outlets #3-Required GFCI protected outlet Outside of share bathroom Unit A & B ) #4-Required breaker for range hook ( kitchen Unit A ) #5-Breaker #18 on panel have not marks or designation for ( Unit A) #6- Please removed plastic coverts for sinks over flow on all bathrooms #7-FBC-R . 302.6 seal all garage and laundry room penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) #8-Seal bottom of dryer freaming ( Unit A & B ) #9-Island , Peninsular , counter tops and work surfaces Recepticles outlets shall be installed in accordance with NEC-21052(C)(2)(A)and (C) (2) (B) ( Unit A & B ) #10-5. Seal up soffit penetrations for electrical mast Unit A & B on Meter base panel ) #11-ODU needs to be 3" from finished grade FBCR M1305.1.4.1 ( unit B ) #12- Breaker interior panel missing Screws on Front face ( Unit A ) | |||
| BLD - BUILDING FINAL | 06/03/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 6/3/2026 2:25:43 PM *** #13-UL.325.6/16 cfr part 1211-Garage door opener safaty eye - maximum oc height of 6" ( to low ) Please fix items before next final inspection #1-NEC Article 230.67 mandates the use of a Surge-Protective Device (SPD) for (A)all services supplying specific occupancies (B)Location.the SPD shall be an integral part of the service equipment or shall be located inmediately adjacent thereto. ( Unit A & B Meter base ) #2-NEC 210.8. This includes receptacles and hard-wired equipment like HVAC units. Weather-resistant (WR-rated) receptacles and in-use weatherproof covers are also required. Exterior outlets #3-Required GFCI protected outlet Outside of share bathroom Unit A & B ) #4-Required breaker for range hook ( kitchen Unit A ) #5-Breaker #18 on panel have not marks or designation for ( Unit A) #6- Please removed plastic coverts for sinks over flow on all bathrooms #7-FBC-R . 302.6 seal all garage and laundry room penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) #8-Seal bottom of dryer freaming ( Unit A & B ) #9-Island , Peninsular , counter tops and work surfaces Recepticles outlets shall be installed in accordance with NEC-21052(C)(2)(A)and (C) (2) (B) ( Unit A & B ) #10-5. Seal up soffit penetrations for electrical mast Unit A & B on Meter base panel ) #11-ODU needs to be 3" from finished grade FBCR M1305.1.4.1 ( unit B ) #12- Breaker interior panel missing Screws on Front face ( Unit A ) | |||
| U -UTILITY RESIDENTIAL FINAL | 06/01/2026 | APPROVED | BVEIGA |
| Note: 5/21/2026 - PREVIOUS INSPECTION NOTES Pep tanks are full no power to panel | |||
| ROW - STORMWATER FINAL | 05/21/2026 | APPROVED | FSLADISH |
| Note: 5/21/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________________ ***INSPECTORS NOTE. BUILDER REQUIRED TO REMOVE HIGH SPOT ON LEFT SIDE FRONT SWALE BETWEEN CULVERTS TO ALLOW FOR POSITIVE SWALE DRAINAGE BEFOR ROW FINAL PASSAGE. *** | |||
| U -UTILITY RESIDENTIAL FINAL | 05/21/2026 | Disapproved - NO FEE | BHAINES |
| Note: Pep tanks are full no power to panel | |||
| ROW - FINAL APRON (AFTER POUR) | 03/10/2026 | APPROVED | FSLADISH |
| Note: 3/10/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE. BUILDER REQUIRED TO REMOVE HIGH SPOT ON LEFT SIDE FRONT SWALE BETWEEN CULVERTS TO ALLOW FOR POSITIVE SWALE DRAINAGE BEFOR ROW FINAL PASSAGE. *** | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/25/2026 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/25/2026 | APPROVED | FSLADISH |
| Note: 2/25/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ELECTRIC - EARLY POWER | 10/16/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 10/16/25 Email sent to FPL --Please attach pvc for ground wires to building by final 8/4/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection , incluid items from previous inspection #1-NEC 110.27-SAFE OFF ALL WIRING Unit A and B , garage AH unit wire , water heater, kitchen sink cabinet outlet wire , microwave wire #2-230.67-SURGE PROTECTOR INSTALLED in bough electrical exterior panels #3- Pep tanks not connected 7/30/2025 - PREVIOUS INSPECTION NOTES Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27 | |||
| ELECTRIC - EARLY POWER | 08/04/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection , incluid items from previous inspection #1-NEC 110.27-SAFE OFF ALL WIRING Unit A and B , garage AH unit wire , water heater, kitchen sink cabinet outlet wire , microwave wire #2-230.67-SURGE PROTECTOR INSTALLED in bough electrical exterior panels #3- Pep tanks not connected 7/30/2025 - PREVIOUS INSPECTION NOTES Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27 | |||
| ELECTRIC - EARLY POWER | 07/30/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27 | |||
| ELECTRIC - EARLY POWER | 07/28/2025 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 05/16/2025 | APPROVED | FSLADISH |
| Note: 5/16/25 MET WITH CONCRETE SUB, MADE A FEW ADJUSTMENTS ON SITE AND HAVE ACHIEVES THE 5" OF CONCRETE OVER CULVERT PIPE. PIPE ELEVATION IS GOOD AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. FOR DRIVEWAYS WITHOUT CULVERT: PIPE ELEVATION GOOD. BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS. 5/14/2025 - PREVIOUS INSPECTION NOTES 05/14/25 TPOLACEK**** CULVERT PIPES IN CUL D SAC'S ARE TO BE 5' OFF EDGE OF ROAD. MITER END FLARE SHOULD BE 18" TO SIDE OF CULVERT AT EDGE OF DRIVEWAY AND 9" AND END OF CULVERT TO SIDE OF PIPE. THERE MUST BE 5" OVER THE TOP OF THE CULVERT ACROSS ENTIRE PIPE. PLEASE RESET ACCORDING TO SWALE PLAN DIAGRAM AND CUL D SAC REQUIRMENTS. 7 Pipe not 8 ft/5 ft from road edge or missing 22 degree Elbow Swale Plan #2 Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| ROW- PRE-APRON (PRE-POUR) | 05/14/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/14/25 TPOLACEK**** CULVERT PIPES IN CUL D SAC'S ARE TO BE 5' OFF EDGE OF ROAD. MITER END FLARE SHOULD BE 18" TO SIDE OF CULVERT AT EDGE OF DRIVEWAY AND 9" AND END OF CULVERT TO SIDE OF PIPE. THERE MUST BE 5" OVER THE TOP OF THE CULVERT ACROSS ENTIRE PIPE. PLEASE RESET ACCORDING TO SWALE PLAN DIAGRAM AND CUL D SAC REQUIRMENTS. 7 Pipe not 8 ft/5 ft from road edge or missing 22 degree Elbow Swale Plan #2 Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| GRAVITY SEWER TEST | 01/07/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION | |||
| SEWER TIE IN | 01/07/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 12/02/2024 | APPROVED | BVITALE |
| LATH/BRICK/ WATER BARRIER | 11/15/2024 | APPROVED | PKNAPIK |
| INSULATION | 11/01/2024 | APPROVED | JSTEWART |
| ALL ROUGH | 10/25/2024 | APPROVED | BTAYLOR |
| Note: New inspection due to canceled inspection 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up. | |||
| ALL ROUGH | 10/14/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up. | |||
| ALL ROUGH | 09/06/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/6/2024 9:18:27 AM *** 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up. | |||
| ALL ROUGH | 09/06/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/6/2024 9:53:04 AM *** 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up. | |||
| ALL ROUGH | 09/05/2024 | CANCELLED BY APPLICANT | WEB |
| FIREWALL FINAL | 08/23/2024 | APPROVED | AGAETANO |
| FIREWALL DRYWALL NAILING | 08/16/2024 | APPROVED | AGAETANO |
| ROOF VALLEY & METAL | 08/09/2024 | APPROVED | AGAETANO |
| WALL SHEATHING | 08/02/2024 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/12/2024 | APPROVED | BTAYLOR |
| TIE BEAM / LINTEL | 06/21/2024 | APPROVED | RSIMS |
| Note: 6/20/2024 - PREVIOUS INSPECTION NOTES 6/20/24: 1). Dumpster needs to be on site. Also, please clean up site of any trash, debris and excess piles of dirt to make site safe for inspection. 2). @ dowels at the back lanai area do not have the minimum 2 " clearance from the face of the CMU as required. FBC-R606.3.4 NOTE: please make sure that silt fence is maintained throughout the entire build. | |||
| TIE BEAM / LINTEL | 06/20/2024 | Disapproved - NO FEE | RSIMS |
| Note: 6/20/24: 1). Dumpster needs to be on site. Also, please clean up site of any trash, debris and excess piles of dirt to make site safe for inspection. 2). @ dowels at the back lanai area do not have the minimum 2 " clearance from the face of the CMU as required. FBC-R606.3.4 NOTE: please make sure that silt fence is maintained throughout the entire build. | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/07/2024 | APPROVED | TDOAK |
| MONOLITHIC SLAB | 05/22/2024 | APPROVED | RSIMS |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/10/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 03/12/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/13/2026 | 05/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/07/2024 | 06/07/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/07/2024 | 06/07/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/07/2024 | 03/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/09/2024 | 01/09/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/09/2024 | 01/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/14/2023 | 01/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/13/2023 | 12/19/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 12/13/2023 | 12/20/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 12/13/2023 | 12/14/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electric load calcs submitted by max and engineer have the wrong living space. Correct both | |||
| ENGIN1 | COMPLETE | 12/13/2023 | 12/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/13/2023 | 12/14/2023 |
| LOCATE | COMPLETE | 12/13/2023 | 12/14/2023 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/13/2023 | 12/14/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/13/2023 | 12/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/13/2023 | 12/14/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Ac mecanical missing from site plan. Driveway needs to be a min of 16' per side. driveway on site plan is proposed differently from landscape plan. Color sheet: materials of exterior walls isn missing Check one of the boxes for the Accent Colors. | |||
| BADMIN | COMPLETE | 12/13/2023 | 12/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 06/07/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/07/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/07/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/07/2026 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/07/2026 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/14/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/14/2024 |
| SEWER CREDIT | (¤4,782.75) | 02/14/2024 |
| SEWER INSPECTION | ¤25.00 | 02/14/2024 |
| SEWER CAPITAL FACILITY | ¤10,882.06 | 02/14/2024 |
| WATER CAPITAL FACILITY FEE | ¤7,989.02 | 02/14/2024 |
| SITE PLAN 30 | ¤30.00 | 02/14/2024 |
| WATER- TURN ON | ¤50.00 | 02/14/2024 |
| ADJUSTMENT 50% | (¤923.98) | 02/14/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/14/2024 |
| INSPECTION - RESIDENTIAL | ¤1,416.25 | 02/14/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤401.70 | 02/14/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 02/14/2024 |
| IMPACT FEE FIRE | ¤856.18 | 02/14/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 02/14/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 02/14/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 02/14/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 02/14/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 02/14/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 02/14/2024 |
| SURCHARGE FS 533.721 | ¤5.22 | 02/14/2024 |
| SURCHARGE - FS 468.631 | ¤7.83 | 02/14/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/14/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/14/2024 |
| SW ENG PRE APRON | ¤30.00 | 02/14/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤35,055.21 |