Permit #2023120504

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00410-0020
CONDITIONED SPACE: 2586 sqft
GARAGE: 820 sqft
OPENED PORCH (WITH ROOF) : 300 sqft
OPENED PORCH (WITH ROOF) : 220 sqft
Total Square Footage: 3926 sqft
Block: 00410
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-569-7882
Location Address: 6 EASTON PL
Type: DU - DUPLEX
Issue Date: 02/14/2024
NOC: RECORDED
Applicant name: VLADIMIR V PEREPECHKIN
Owner: SHMAKOV ANDREY & LYUBOV H&W

Address

17 ZEPHYR LILY PLACE

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤485,000.00
Job Description: DUPLEX
Type: CN

Contractor

WISE CHOICE CUSTOM HOMES, INC.
Status Location Address State License Number Phone
ACTIVE

77 SOUTHLAKE DR

PALM COAST, FL 32137

CRC1328738 (Exp: 08/31/2026) 386-569-7882

Sub Contractors

ANDREW GONCALVES HOWARD
Status Location Address State License Number Phone
ACTIVE

2 RYALL LANE

PALM COAST, FL 32164

CCC1333989 (Exp: 08/31/2026) 386-347-0366
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 06/10/2026 APPROVED - AS NOTED BVEIGA
Note: NO/CC NO/IRR
BLD - BUILDING FINAL 06/04/2026 FINAL APPROVED KSANDOE
Note: 6/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next final inspection #1-NEC Article 230.67 mandates the use of a Surge-Protective Device (SPD) for (A)all services supplying specific occupancies (B)Location.the SPD shall be an integral part of the service equipment or shall be located inmediately adjacent thereto. ( Unit A & B Meter base ) #2-NEC 210.8. This includes receptacles and hard-wired equipment like HVAC units. Weather-resistant (WR-rated) receptacles and in-use weatherproof covers are also required. Exterior outlets #3-Required GFCI protected outlet Outside of share bathroom Unit A & B ) #4-Required breaker for range hook ( kitchen Unit A ) #5-Breaker #18 on panel have not marks or designation for ( Unit A) #6- Please removed plastic coverts for sinks over flow on all bathrooms #7-FBC-R . 302.6 seal all garage and laundry room penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) #8-Seal bottom of dryer freaming ( Unit A & B ) #9-Island , Peninsular , counter tops and work surfaces Recepticles outlets shall be installed in accordance with NEC-21052(C)(2)(A)and (C) (2) (B) ( Unit A & B ) #10-5. Seal up soffit penetrations for electrical mast Unit A & B on Meter base panel ) #11-ODU needs to be 3" from finished grade FBCR M1305.1.4.1 ( unit B ) #12- Breaker interior panel missing Screws on Front face ( Unit A )
BLD - BUILDING FINAL 06/03/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 6/3/2026 2:25:43 PM *** #13-UL.325.6/16 cfr part 1211-Garage door opener safaty eye - maximum oc height of 6" ( to low ) Please fix items before next final inspection #1-NEC Article 230.67 mandates the use of a Surge-Protective Device (SPD) for (A)all services supplying specific occupancies (B)Location.the SPD shall be an integral part of the service equipment or shall be located inmediately adjacent thereto. ( Unit A & B Meter base ) #2-NEC 210.8. This includes receptacles and hard-wired equipment like HVAC units. Weather-resistant (WR-rated) receptacles and in-use weatherproof covers are also required. Exterior outlets #3-Required GFCI protected outlet Outside of share bathroom Unit A & B ) #4-Required breaker for range hook ( kitchen Unit A ) #5-Breaker #18 on panel have not marks or designation for ( Unit A) #6- Please removed plastic coverts for sinks over flow on all bathrooms #7-FBC-R . 302.6 seal all garage and laundry room penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) #8-Seal bottom of dryer freaming ( Unit A & B ) #9-Island , Peninsular , counter tops and work surfaces Recepticles outlets shall be installed in accordance with NEC-21052(C)(2)(A)and (C) (2) (B) ( Unit A & B ) #10-5. Seal up soffit penetrations for electrical mast Unit A & B on Meter base panel ) #11-ODU needs to be 3" from finished grade FBCR M1305.1.4.1 ( unit B ) #12- Breaker interior panel missing Screws on Front face ( Unit A )
U -UTILITY RESIDENTIAL FINAL 06/01/2026 APPROVED BVEIGA
Note: 5/21/2026 - PREVIOUS INSPECTION NOTES Pep tanks are full no power to panel
ROW - STORMWATER FINAL 05/21/2026 APPROVED FSLADISH
Note: 5/21/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________________ ***INSPECTORS NOTE. BUILDER REQUIRED TO REMOVE HIGH SPOT ON LEFT SIDE FRONT SWALE BETWEEN CULVERTS TO ALLOW FOR POSITIVE SWALE DRAINAGE BEFOR ROW FINAL PASSAGE. ***
U -UTILITY RESIDENTIAL FINAL 05/21/2026 Disapproved - NO FEE BHAINES
Note: Pep tanks are full no power to panel
ROW - FINAL APRON (AFTER POUR) 03/10/2026 APPROVED FSLADISH
Note: 3/10/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE. BUILDER REQUIRED TO REMOVE HIGH SPOT ON LEFT SIDE FRONT SWALE BETWEEN CULVERTS TO ALLOW FOR POSITIVE SWALE DRAINAGE BEFOR ROW FINAL PASSAGE. ***
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/25/2026 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 02/25/2026 APPROVED FSLADISH
Note: 2/25/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ELECTRIC - EARLY POWER 10/16/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 10/16/25 Email sent to FPL --Please attach pvc for ground wires to building by final 8/4/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection , incluid items from previous inspection #1-NEC 110.27-SAFE OFF ALL WIRING Unit A and B , garage AH unit wire , water heater, kitchen sink cabinet outlet wire , microwave wire #2-230.67-SURGE PROTECTOR INSTALLED in bough electrical exterior panels #3- Pep tanks not connected 7/30/2025 - PREVIOUS INSPECTION NOTES Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27
ELECTRIC - EARLY POWER 08/04/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection , incluid items from previous inspection #1-NEC 110.27-SAFE OFF ALL WIRING Unit A and B , garage AH unit wire , water heater, kitchen sink cabinet outlet wire , microwave wire #2-230.67-SURGE PROTECTOR INSTALLED in bough electrical exterior panels #3- Pep tanks not connected 7/30/2025 - PREVIOUS INSPECTION NOTES Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27
ELECTRIC - EARLY POWER 07/30/2025 Disapproved - NO FEE JSTEWART
Note: Right side: 1.Install faceplate front bedroom receptacle. NEC 110.27 2. Install face plate spare bath switch. NEC 110.27 3. safe off master closet Light outlet, Min cap wires. NEC 110.27
ELECTRIC - EARLY POWER 07/28/2025 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 05/16/2025 APPROVED FSLADISH
Note: 5/16/25 MET WITH CONCRETE SUB, MADE A FEW ADJUSTMENTS ON SITE AND HAVE ACHIEVES THE 5" OF CONCRETE OVER CULVERT PIPE. PIPE ELEVATION IS GOOD AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. FOR DRIVEWAYS WITHOUT CULVERT: PIPE ELEVATION GOOD. BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS. 5/14/2025 - PREVIOUS INSPECTION NOTES 05/14/25 TPOLACEK**** CULVERT PIPES IN CUL D SAC'S ARE TO BE 5' OFF EDGE OF ROAD. MITER END FLARE SHOULD BE 18" TO SIDE OF CULVERT AT EDGE OF DRIVEWAY AND 9" AND END OF CULVERT TO SIDE OF PIPE. THERE MUST BE 5" OVER THE TOP OF THE CULVERT ACROSS ENTIRE PIPE. PLEASE RESET ACCORDING TO SWALE PLAN DIAGRAM AND CUL D SAC REQUIRMENTS. 7 Pipe not 8 ft/5 ft from road edge or missing 22 degree Elbow Swale Plan #2 Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow.
ROW- PRE-APRON (PRE-POUR) 05/14/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 05/14/25 TPOLACEK**** CULVERT PIPES IN CUL D SAC'S ARE TO BE 5' OFF EDGE OF ROAD. MITER END FLARE SHOULD BE 18" TO SIDE OF CULVERT AT EDGE OF DRIVEWAY AND 9" AND END OF CULVERT TO SIDE OF PIPE. THERE MUST BE 5" OVER THE TOP OF THE CULVERT ACROSS ENTIRE PIPE. PLEASE RESET ACCORDING TO SWALE PLAN DIAGRAM AND CUL D SAC REQUIRMENTS. 7 Pipe not 8 ft/5 ft from road edge or missing 22 degree Elbow Swale Plan #2 Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow.
GRAVITY SEWER TEST 01/07/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION
SEWER TIE IN 01/07/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION
PEP TANK INSTALLATION REQUEST 12/02/2024 APPROVED BVITALE
LATH/BRICK/ WATER BARRIER 11/15/2024 APPROVED PKNAPIK
INSULATION 11/01/2024 APPROVED JSTEWART
ALL ROUGH 10/25/2024 APPROVED BTAYLOR
Note: New inspection due to canceled inspection 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up.
ALL ROUGH 10/14/2024 CANCELLED BY APPLICANT WEB
Note: 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up.
ALL ROUGH 09/06/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/6/2024 9:18:27 AM *** 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up.
ALL ROUGH 09/06/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 9/6/2024 9:53:04 AM *** 9/6/24: Needed to add the item below before re-inspection. 7). Both Units: Missing screws at joints/connections as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 9/6/2024 - PREVIOUS INSPECTION NOTES 9/6/24: Both Units: 1). Installed ductwork does not match what is required on the approved ECalcs. Highlighted. FBC[A] 107.4 2). No 5ft. head pressure. FBC-P312.2 3). Please install larger steel plates where service cables penetrate top plates to provide ample protection coverage. NEC-300.5) 4). Need a revision for an engineer's approval (from window/ door manufacturer) for the window installation application than what is approved through DBPR. Fin windows & doors are in rough openings designed for through the frame application. FBC[A] 107.4 5). Interior garage doors are not installed. (Need to be installed prior to insulation inspection). 6). Need a dumpster on site and piles of trash/debris cleaned up.
ALL ROUGH 09/05/2024 CANCELLED BY APPLICANT WEB
FIREWALL FINAL 08/23/2024 APPROVED AGAETANO
FIREWALL DRYWALL NAILING 08/16/2024 APPROVED AGAETANO
ROOF VALLEY & METAL 08/09/2024 APPROVED AGAETANO
WALL SHEATHING 08/02/2024 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2024 APPROVED BTAYLOR
TIE BEAM / LINTEL 06/21/2024 APPROVED RSIMS
Note: 6/20/2024 - PREVIOUS INSPECTION NOTES 6/20/24: 1). Dumpster needs to be on site. Also, please clean up site of any trash, debris and excess piles of dirt to make site safe for inspection. 2). @ dowels at the back lanai area do not have the minimum 2 " clearance from the face of the CMU as required. FBC-R606.3.4 NOTE: please make sure that silt fence is maintained throughout the entire build.
TIE BEAM / LINTEL 06/20/2024 Disapproved - NO FEE RSIMS
Note: 6/20/24: 1). Dumpster needs to be on site. Also, please clean up site of any trash, debris and excess piles of dirt to make site safe for inspection. 2). @ dowels at the back lanai area do not have the minimum 2 " clearance from the face of the CMU as required. FBC-R606.3.4 NOTE: please make sure that silt fence is maintained throughout the entire build.
FOUND SURVEY APPROVED (OFFICE) 06/07/2024 APPROVED TDOAK
MONOLITHIC SLAB 05/22/2024 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 05/10/2024 APPROVED - AS NOTED MGIBSON
Note: 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BY SLAB INSPECTION
WATER METER INSTALLATION REQUEST 03/12/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/13/2026 05/13/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/07/2024 06/07/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/07/2024 06/07/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 03/07/2024 03/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 01/09/2024 01/09/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC COMPLETE 01/09/2024 01/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 12/14/2023 01/30/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/13/2023 12/19/2023
Note: Released By: JPI
CUSVC COMPLETE 12/13/2023 12/20/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 12/13/2023 12/14/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electric load calcs submitted by max and engineer have the wrong living space. Correct both
ENGIN1 COMPLETE 12/13/2023 12/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 12/13/2023 12/14/2023
LOCATE COMPLETE 12/13/2023 12/14/2023
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/13/2023 12/14/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/13/2023 12/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 12/13/2023 12/14/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Ac mecanical missing from site plan. Driveway needs to be a min of 16' per side. driveway on site plan is proposed differently from landscape plan. Color sheet: materials of exterior walls isn missing Check one of the boxes for the Accent Colors.
BADMIN COMPLETE 12/13/2023 12/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/07/2026
REINSPECTION RESIDENTIAL ¤40.00 06/07/2026
REINSPECTION RESIDENTIAL ¤40.00 06/07/2026
REINSPECTION RESIDENTIAL ¤40.00 06/07/2026
SW ENG REINSPECTION 30 ¤30.00 06/07/2026
SW ENG - REVIEW 20 ¤20.00 02/14/2024
SW ENG RES REVIEW 200 ¤200.00 02/14/2024
SEWER CREDIT (¤4,782.75) 02/14/2024
SEWER INSPECTION ¤25.00 02/14/2024
SEWER CAPITAL FACILITY ¤10,882.06 02/14/2024
WATER CAPITAL FACILITY FEE ¤7,989.02 02/14/2024
SITE PLAN 30 ¤30.00 02/14/2024
WATER- TURN ON ¤50.00 02/14/2024
ADJUSTMENT 50% (¤923.98) 02/14/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/14/2024
INSPECTION - RESIDENTIAL ¤1,416.25 02/14/2024
PLAN REVIEW - RESIDENTIAL ¤401.70 02/14/2024
FC IMPACT FEE EMS ¤124.00 02/14/2024
IMPACT FEE FIRE ¤856.18 02/14/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/14/2024
FC IMPACT FEE LIBRARY ¤536.00 02/14/2024
IMPACT FEE PARKS ¤3,600.18 02/14/2024
IMPACT FEE SCHOOL ¤10,900.00 02/14/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 02/14/2024
WATER -IRRIGATION INSPECTION ¤50.00 02/14/2024
SURCHARGE FS 533.721 ¤5.22 02/14/2024
SURCHARGE - FS 468.631 ¤7.83 02/14/2024
SW ENG - FOUNDATION SURVEY ¤20.00 02/14/2024
SW ENG INSPECTION 80 ¤80.00 02/14/2024
SW ENG PRE APRON ¤30.00 02/14/2024
Fees Total Due: ¤0.00 Total Paid: ¤35,055.21