I want to search for...
Permit #2023120538
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00010-0030 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 00010 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 904-268-7730 |
| Location Address: 7 PONCE DELEON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/04/2024 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES, LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
DANIEL GREGORY PUGLISI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13011195 (Exp: 08/31/2024) | 407-302-7800 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1165 SOUTH 5TH MACCLENNY, FL 32063 |
CCC1330709 (Exp: 08/31/2026) | 904-322-9409 |
CLINTON J HULSLANDER SR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CFC1430632 (Exp: 08/31/2026) | 407-321-0064 | 407-688-8534 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/22/2024 | FINAL APPROVED | RSIMS |
| Note: 5/21/2024 - PREVIOUS INSPECTION NOTES 5/21/24: 1). CM/SD detectors along with Smoke Detector in Master bedroom are not innerconnected when tested. R314.4 Interconnection. 2). Hole in garage ceiling needs to be sealed as required. (FBC-R302.11). | |||
| ROW - STORMWATER FINAL | 05/22/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 5/22/24 CORRECTIONS REQUIRED COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ 5/21/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 5/20 UPONWALKING THE PROPERTY DETERMINED IN THE REAR RIGHT CORNER THAT YOU WILL NEED TO MOVE THAT CORNER BACK A BIT TO GET A 4:1 SLOPE CLOSER TO THE FENCE, IT IS TOO FAR AWAY WITH TO MUCH FALL AREA CURRENTLY. APPROVING THIS AS NOTED THAT YOU HAVE CORRECTIONS TO MAKE. DEPENDING ON FIELD CONDITIONS ON ANY FUTURE INSPECTIONS ADDITIONAL CORRECTIONS MAY BE REQUIRED. | |||
| U -UTILITY RESIDENTIAL FINAL | 05/21/2024 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/13/2024 9:46:56 AM *** no irr-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 05/21/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 5/21/24 PIPE ELEVATION GOOD. CUTS MADE. CULVERT CLEAR HOT PATCH NOT COMPLETED (WILL BE HELD OUT FOR ROW FINAL) At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 5/20 UPONWALKING THE PROPERTY DETERMINED IN THE REAR RIGHT CORNER THAT YOU WILL NEED TO MOVE THAT CORNER BACK A BIT TO GET A 4:1 SLOPE CLOSER TO THE FENCE, IT IS TOO FAR AWAY WITH TO MUCH FALL AREA CURRENTLY. APPROVING THIS AS NOTED THAT YOU HAVE CORRECTIONS TO MAKE. DEPENDING ON FIELD CONDITIONS ON ANY FUTURE INSPECTIONS ADDITIONAL CORRECTIONS MAY BE REQUIRED. | |||
| BLD - BUILDING FINAL | 05/21/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/21/24: 1). CM/SD detectors along with Smoke Detector in Master bedroom are not innerconnected when tested. R314.4 Interconnection. 2). Hole in garage ceiling needs to be sealed as required. (FBC-R302.11). | |||
| ROW - STORMWATER FINAL | 05/21/2024 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 5/21/24 YOU WILL NEED TO BRING THE RIGHT SIDE FRONT SWALE UP TO MATCH GRADE AT THE ADJOINING PROPERTY LINE. OUTLINED IN WHITE PAINT BEFORE ROW FINAL. . Inspector Notes from Inspection 9465 5/20 UPONWALKING THE PROPERTY DETERMINED IN THE REAR RIGHT CORNER THAT YOU WILL NEED TO MOVE THAT CORNER BACK A BIT TO GET A 4:1 SLOPE CLOSER TO THE FENCE, IT IS TOO FAR AWAY WITH TO MUCH FALL AREA CURRENTLY. APPROVING THIS AS NOTED THAT YOU HAVE CORRECTIONS TO MAKE. DEPENDING ON FIELD CONDITIONS ON ANY FUTURE INSPECTIONS ADDITIONAL CORRECTIONS MAY BE REQUIRED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/20/2024 | APPROVED | FSLADISH |
| Note: 5/20/24 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/20/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 5/20 UPONWALKING THE PROPERTY DETERMINED IN THE REAR RIGHT CORNER THAT YOU WILL NEED TO MOVE THAT CORNER BACK A BIT TO GET A 4:1 SLOPE CLOSER TO THE FENCE, IT IS TOO FAR AWAY WITH TO MUCH FALL AREA CURRENTLY. APPROVING THIS AS NOTED THAT YOU HAVE CORRECTIONS TO MAKE. DEPENDING ON FIELD CONDITIONS ON ANY FUTURE INSPECTIONS ADDITIONAL CORRECTIONS MAY BE REQUIRED. | |||
| U-CROSS CONNECTION | 05/13/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 5/13/2024 9:46:56 AM *** no irr-no cross connection | |||
| ROW- PRE-APRON (PRE-POUR) | 05/06/2024 | APPROVED | PFLANAGAN |
| Note: *** NOTES ADDED BY PFLANAGAN 5/6/2024 8:48:38 AM *** IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ELECTRIC - EARLY POWER | 04/23/2024 | APPROVED | RSIMS |
| Note: 4/23/24: FPL emailed to release power. 4/22/2024 - PREVIOUS INSPECTION NOTES Supply for microwave must be safed off Inspector Notes from Inspection 2200 2/29/24- Authorize release of email to FPL @ 10:02a | |||
| ELECTRIC - EARLY POWER | 04/22/2024 | Disapproved - NO FEE | KSANDOE |
| Note: Supply for microwave must be safed off Inspector Notes from Inspection 2200 2/29/24- Authorize release of email to FPL @ 10:02a | |||
| SEWER TIE IN | 04/16/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO LIST CORRECT PLUMBING SUB CONTRACTOR | |||
| PEP TANK INSTALLATION REQUEST | 03/22/2024 | APPROVED | BVITALE |
| INSULATION | 03/18/2024 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 03/13/2024 | APPROVED | FWILLIS |
| ALL ROUGH | 03/13/2024 | APPROVED | KSANDOE |
| ROOF VALLEY & METAL | 03/05/2024 | APPROVED | MKRASKI |
| WALL SHEATHING | 02/29/2024 | APPROVED | JSTEWART |
| Note: 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: 1). Sheathing is not nailed at window and door headers including at garage as required on SD1 plan page. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/29/2024 | APPROVED | JSTEWART |
| Note: 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: Roof Sheathing Approved on Inspection 2465 Roof Sheathing. 1). 3-Ply Truss GP01is not connected together as required on the truss page & the outside is covered with plywood so it cannot be verified. Will need a revision from the engineer for the different connecting application applied. 2). Plans are missing tie down detail for the different application used. Plans RP5.0 and SD1 show still show straps, etc. and Plan page 5.1 Anchor Strapping Plan does not have any detail on it for locations, type of screw, etc. *** Truss engineering checked and approved except for the connecting of Truss GP01 as noted. | |||
| ELECTRIC-TUG | 02/29/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 2/29/24- Authorize release of email to FPL @ 10:02a | |||
| ROOF SHEATHING | 02/28/2024 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/28/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 2/28/24: Roof Sheathing Approved on Inspection 2465 Roof Sheathing. 1). 3-Ply Truss GP01is not connected together as required on the truss page & the outside is covered with plywood so it cannot be verified. Will need a revision from the engineer for the different connecting application applied. 2). Plans are missing tie down detail for the different application used. Plans RP5.0 and SD1 show still show straps, etc. and Plan page 5.1 Anchor Strapping Plan does not have any detail on it for locations, type of screw, etc. *** Truss engineering checked and approved except for the connecting of Truss GP01 as noted. | |||
| WALL SHEATHING | 02/28/2024 | Disapproved - NO FEE | RSIMS |
| Note: 2/28/24: 1). Sheathing is not nailed at window and door headers including at garage as required on SD1 plan page. | |||
| TIE BEAM / LINTEL | 02/26/2024 | CANCELLED BY INSPECTOR | RSIMS |
| Note: 2/26/24: This inspection is not required as this is a fully wood framed structure. Inspector Notes from Inspection 2250 2/16/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). Please clean out the dirt cave in at the front & right side of garage footers. 3). Footer at garage back wall does not meet the depth requirements consistently. 4). The wire mesh is laying directly on the slab in numerous places. You will need to add chairs throughout to mainatin clearance. 2/14/2024 - PREVIOUS INSPECTION NOTES 2/14/24 Prints are wet and out of order. Please have a full set of approved plans in order and onsite for all inspection. Inspection stopped. A full slab inspection will still need to be done. 2/13/2024 - PREVIOUS INSPECTION NOTES ON SITE AS REQUESTED, PLASTIC AND WIRE REMOVED IN AREA BEHIND THE GARAGE. LEFT SIDE IS CAVED IN. ALSO, ALL PLANS ARE ON THE GROUND THROWN ABOUT. | |||
| MONOLITHIC SLAB | 02/20/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 2/16/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). Please clean out the dirt cave in at the front & right side of garage footers. 3). Footer at garage back wall does not meet the depth requirements consistently. 4). The wire mesh is laying directly on the slab in numerous places. You will need to add chairs throughout to mainatin clearance. 2/14/2024 - PREVIOUS INSPECTION NOTES 2/14/24 Prints are wet and out of order. Please have a full set of approved plans in order and onsite for all inspection. Inspection stopped. A full slab inspection will still need to be done. 2/13/2024 - PREVIOUS INSPECTION NOTES ON SITE AS REQUESTED, PLASTIC AND WIRE REMOVED IN AREA BEHIND THE GARAGE. LEFT SIDE IS CAVED IN. ALSO, ALL PLANS ARE ON THE GROUND THROWN ABOUT. | |||
| MONOLITHIC SLAB | 02/15/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 2/15/24: 1). Please repair your silt fence barrier as soon as possible & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. 2). Please clean out the dirt cave in at the front & right side of garage footers. 3). Footer at garage back wall does not meet the depth requirements consistently. 4). The wire mesh is laying directly on the slab in numerous places. You will need to add chairs throughout to mainatin clearance. 2/14/2024 - PREVIOUS INSPECTION NOTES 2/14/24 Prints are wet and out of order. Please have a full set of approved plans in order and onsite for all inspection. Inspection stopped. A full slab inspection will still need to be done. 2/13/2024 - PREVIOUS INSPECTION NOTES ON SITE AS REQUESTED, PLASTIC AND WIRE REMOVED IN AREA BEHIND THE GARAGE. LEFT SIDE IS CAVED IN. ALSO, ALL PLANS ARE ON THE GROUND THROWN ABOUT. | |||
| MONOLITHIC SLAB | 02/14/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 2/14/24 Prints are wet and out of order. Please have a full set of approved plans in order and onsite for all inspection. Inspection stopped. A full slab inspection will still need to be done. 2/13/2024 - PREVIOUS INSPECTION NOTES ON SITE AS REQUESTED, PLASTIC AND WIRE REMOVED IN AREA BEHIND THE GARAGE. LEFT SIDE IS CAVED IN. ALSO, ALL PLANS ARE ON THE GROUND THROWN ABOUT. | |||
| MONOLITHIC SLAB | 02/13/2024 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: ON SITE AS REQUESTED, PLASTIC AND WIRE REMOVED IN AREA BEHIND THE GARAGE. LEFT SIDE IS CAVED IN. ALSO, ALL PLANS ARE ON THE GROUND THROWN ABOUT. | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/12/2024 | APPROVED | TBAKER |
| Note: CLEARING | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/08/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 02/08/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/26/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 1/23/2024 8:51:06 AM- PREVIOUS INSPECTION NOTES | |||
| WATER METER INSTALLATION REQUEST | 01/25/2024 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection 1/23/2024 8:51:06 AM- PREVIOUS INSPECTION NOTES | |||
| WATER METER INSTALLATION REQUEST | 01/24/2024 | APPROVED | BVITALE |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection 1/23/2024 8:51:06 AM- PREVIOUS INSPECTION NOTES | |||
| WATER METER INSTALLATION REQUEST | 01/19/2024 | Disapproved -FEE REQUIRED | BVITALE |
| WATER METER INSTALLATION REQUEST | 01/18/2024 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 02/09/2024 | 02/09/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/09/2024 | 02/09/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/05/2024 | 01/05/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM a new permit application (signed and notarized) must be submitted with the new deed | |||
| ZON | COMPLETE | 12/27/2023 | 12/27/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/27/2023 | 12/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/27/2023 | 01/04/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/14/2023 | 12/19/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 12/14/2023 | 12/20/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/14/2023 | 12/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/14/2023 | 12/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/14/2023 | 12/14/2023 |
| LOCATE | COMPLETE | 12/14/2023 | 12/14/2023 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/14/2023 | 12/14/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/14/2023 | 12/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/14/2023 | 12/14/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Setbacks covered up by other numbers. Please make sure all setbacks are visible to review | |||
| BADMIN | COMPLETE | 12/14/2023 | 12/21/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/14/2023 | 01/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/22/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/22/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/22/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/22/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 05/22/2024 |
| REINSPECTION FEE | ¤40.00 | 05/22/2024 |
| SURCHARGE FS 533.721 | ¤3.77 | 01/04/2024 |
| SURCHARGE - FS 468.631 | ¤5.66 | 01/04/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/04/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/04/2024 |
| SW ENG PRE APRON | ¤30.00 | 01/04/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/04/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/04/2024 |
| SEWER CREDIT | (¤650.00) | 01/04/2024 |
| SEWER INSPECTION | ¤25.00 | 01/04/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 01/04/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 01/04/2024 |
| SITE PLAN 30 | ¤30.00 | 01/04/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 01/04/2024 |
| IMPACT FEE FIRE | ¤428.09 | 01/04/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/04/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/04/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 01/04/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/04/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 01/04/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/04/2024 |
| CONNECTION FEES | ¤1,187.26 | 01/04/2024 |
| WATER- TURN ON | ¤25.00 | 01/04/2024 |
| ADJUSTMENT 50% | (¤664.52) | 01/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/04/2024 |
| INSPECTION - RESIDENTIAL | ¤1,012.00 | 01/04/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤287.04 | 01/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,360.83 |