Permit #2023120649
Permit Details
Status: COED
| Parcel Id: 07-11-31-7018-00010-0050 |
| CONDITIONED SPACE: 2177 sqft |
| GARAGE: 743 sqft |
| OPENED PORCH (WITH ROOF) : 180 sqft |
| OPENED PORCH (WITH ROOF) : 80 sqft |
| Total Square Footage: 3180 sqft |
| Block: 00010 |
| Subdivision: 2181 - SECTION 18-WYNNFIELD |
| Job Phone: (386)931-0785 |
| Location Address: 2 WAGNER PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/16/2024 |
| NOC: RECORDED |
| Applicant name: ROY CHARLES WALDHAUER |
| Owner: BY THE SHORE INC & BAV PROPERTIES |
|
Address 164 ULYSSES TRAIL PALM COAST, FL 32164 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤375,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
BY THE SHORE INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 09/11/2024 | FINAL APPROVED | MKRASKI |
| BLD - BUILDING FINAL | 09/09/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. No hot water in home FBCR P2722.2 2. Breaker in meter main must be labeled NEC 408.4 3. Spare bedrooms require alight or switched outlet NEC 210.70 | |||
| ROW - FINAL APRON (AFTER POUR) | 09/03/2024 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 8/30/2024 - PREVIOUS INSPECTION NOTES 08/30/24 TPOLACEK** CULVERT HAS TOO MUCH SEDIMENT IN PIPE. AS STATED IN NOTE LEFT ON INSPECTION ON 08/29/24 YOU MUST CLEAN OUT PIPE PRIOR TO SCHEDULING INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++ PLEASE MAKE AURE CULVERT IS CLEANED OUT BEFORE SCHEDULING AFTER POUR. | |||
| ROW - FINAL APRON (AFTER POUR) | 08/30/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 08/30/24 TPOLACEK** CULVERT HAS TOO MUCH SEDIMENT IN PIPE. AS STATED IN NOTE LEFT ON INSPECTION ON 08/29/24 YOU MUST CLEAN OUT PIPE PRIOR TO SCHEDULING INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++ PLEASE MAKE AURE CULVERT IS CLEANED OUT BEFORE SCHEDULING AFTER POUR. | |||
| U-CROSS CONNECTION | 08/30/2024 | APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 08/30/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 08/30/2024 | FINAL APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/29/2024 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/29/2024 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| SEWER TIE IN | 08/01/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 Inspector Notes from Inspection 2060 NEED TO HAVE ADDRESS POSTED FOR ''911'' ON POST OR PERMIT BOARD, ALSO NEED SILT FENCE IN PLACE BEFORE NEXT INSPECTION 3307.1 PROTECTION OF PROPERTY SEWER LINE RAN SEWER TIE -IN NOT MADE YET THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC - EARLY POWER | 07/12/2024 | APPROVED | RSIMS |
| Note: 7/12/24: FPL emailed to release power. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/28/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| GRAVITY SEWER TEST | 06/06/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED TO HAVE ADDRESS POSTED FOR ''911'' ON POST OR PERMIT BOARD, ALSO NEED SILT FENCE IN PLACE BEFORE NEXT INSPECTION 3307.1 PROTECTION OF PROPERTY SEWER LINE RAN SEWER TIE -IN NOT MADE YET | |||
| WINDOW NAILING | 05/09/2024 | APPROVED | MKRASKI |
| INSULATION | 05/08/2024 | APPROVED | MKRASKI |
| INSULATION | 05/07/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2320 1. Windows do not match product approval (added window nailing) 2. Load bearing wall in garage is not sittin 100% on slab, slab needs to be extended out to carry the weight of the load 3. Exhaust fan ducts need to have two points of connection (a mechanical connection and a seal) | |||
| LATH/BRICK/ WATER BARRIER | 05/02/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Windows do not match product approval (added window nailing) 2. Load bearing wall in garage is not sittin 100% on slab, slab needs to be extended out to carry the weight of the load 3. Exhaust fan ducts need to have two points of connection (a mechanical connection and a seal) | |||
| ALL ROUGH | 04/30/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Windows do not match product approval (added window nailing) 2. Load bearing wall in garage is not sittin 100% on slab, slab needs to be extended out to carry the weight of the load 3. Exhaust fan ducts need to have two points of connection (a mechanical connection and a seal) | |||
| ROOF VALLEY & METAL | 04/18/2024 | APPROVED | AGAETANO |
| Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 1. First run of underlayment , near drip edge is required to have two layers of synthetic 2. 5x5 wall flashing is required to be sealed to CMU @ entry | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/16/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 4/16/24 1. Missing girder strap that was installed but has been covered up by insulation board 2. Load bearing was is not 100% sitting on slab and needs to be repaired Check both items at all rough 4/9/2024 - PREVIOUS INSPECTION NOTES 1. CMU to load bearing wall not per detail 2. Load bearing was has stud cut short and not touching bottom plate 3. Anchor in bottom plate of load bearing wall must be on each side of the splice 4. Back right bedroom girder missing second truss strap 5. SP4 in load bearing wall missing nails | |||
| ROOF VALLEY & METAL | 04/16/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. First run of underlayment , near drip edge is required to have two layers of synthetic 2. 5x5 wall flashing is required to be sealed to CMU @ entry | |||
| WALL SHEATHING | 04/09/2024 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/09/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. CMU to load bearing wall not per detail 2. Load bearing was has stud cut short and not touching bottom plate 3. Anchor in bottom plate of load bearing wall must be on each side of the splice 4. Back right bedroom girder missing second truss strap 5. SP4 in load bearing wall missing nails | |||
| TIE BEAM / LINTEL | 03/26/2024 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 03/21/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Bed joints can not be over 3/8'' FBC 606.3.1 Check all | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/12/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/27/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: Silt fence needs to be repaired by next inspection | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/22/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO HAVE ADDRESS POSTED FOR ''911'' ON POST OR PERMIT BOARD, ALSO NEED SILT FENCE IN PLACE BEFORE NEXT INSPECTION 3307.1 PROTECTION OF PROPERTY | |||
| WATER METER INSTALLATION REQUEST | 02/05/2024 | APPROVED | BVITALE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/03/2024 | 05/07/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/12/2024 | 03/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/12/2024 | 03/12/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/05/2024 | 01/05/2024 |
| Note: Released By: JPI | |||
| BADMIN | INFORMATION | 01/04/2024 | 01/04/2024 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM missing DIGITAL seal on truss layout | |||
| MECH | COMPLETE | 12/27/2023 | 01/04/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/27/2023 | 12/28/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/27/2023 | 12/27/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/27/2023 | 12/28/2023 |
| Note: Held By: JPI Repeating comment 1) Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| BLD | HOLD | 12/18/2023 | 12/21/2023 |
| Note: Held By: JPI 1) Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. 2) The conditioned space in the energy calculations vary from what is shown in the living space SF table on Sheet 2. Please cure. 107.2.6 | |||
| CUSVC | COMPLETE | 12/18/2023 | 12/19/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 12/18/2023 | 12/18/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Outlet located in laundry, garage, bathroom, kitchen, outsidemust be GFCI protected. NEC 2017 210.8 2. Need service outley by A/C unit. NEC 2017 210.63 3. Need correct outlet spacing on island. NEC 2017 210.52 (C) (2) | |||
| ENGIN1 | COMPLETE | 12/18/2023 | 12/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/18/2023 | 12/18/2023 |
| LOCATE | COMPLETE | 12/18/2023 | 12/20/2023 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/18/2023 | 12/18/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Square footage on Energy Calcs does not match the house plans | |||
| SW1 | COMPLETE | 12/18/2023 | 12/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/18/2023 | 12/18/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The size of this lot requires 5 trees. Please correct the exterior elevation page. Both side elevations are labeled the same - one should be left and the other right. | |||
| BADMIN | COMPLETE | 12/18/2023 | 12/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/18/2023 | 02/02/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 09/06/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/06/2024 |
| CONNECTION FEES | ¤1,187.26 | 01/16/2024 |
| WATER- TURN ON | ¤25.00 | 01/16/2024 |
| ADJUSTMENT 50% | (¤766.89) | 01/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/16/2024 |
| INSPECTION - RESIDENTIAL | ¤1,171.50 | 01/16/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤332.28 | 01/16/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 01/16/2024 |
| IMPACT FEE FIRE | ¤428.09 | 01/16/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/16/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/16/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 01/16/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/16/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 01/16/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/16/2024 |
| SURCHARGE FS 533.721 | ¤4.35 | 01/16/2024 |
| SURCHARGE - FS 468.631 | ¤6.52 | 01/16/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/16/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/16/2024 |
| SW ENG PRE APRON | ¤30.00 | 01/16/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/16/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/16/2024 |
| SEWER CREDIT | (¤1,147.00) | 01/16/2024 |
| SEWER INSPECTION | ¤25.00 | 01/16/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 01/16/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 01/16/2024 |
| SITE PLAN 30 | ¤30.00 | 01/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,827.64 |