Permit #2023120744
Permit Details
Status: FINAL
| Parcel Id: 10-11-30-5115-00000-0100 |
| Block: 01020 |
| Subdivision: - |
| Job Phone: 386-252-7407 |
| Location Address: 1 PINE LAKES PKWY N |
| Type: FS - FIRE SPRINKLER WET COMMERCIAL |
| Issue Date: 04/26/2024 |
| NOC: Unknown |
| Applicant name: ANDY JOHNSTON |
| Owner: FIRST BAPTIST CHURCH OF PALM COAST FLORIDA INC |
|
Address 6050 PALM COAST PARKWAY NW PALM COAST, FL 32137 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤103,033.00 |
| Job Description: FIRE SPINKLER HEADS |
| Type: CN |
Contractor
MASTER CRAFT PLUMBING CONTRACTORS, INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
887 BRENTWOOD DRIVE DAYTONA BEACH, FL 32117 |
1944870002010 (Exp: 06/30/2026) | 386-252-7407 | 386-898-0322 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE SYSTEM FLUSH | 08/08/2024 | APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 8/8/2024 3:05:32 PM *** system was tagged and flushed | |||
| FIRE SPRINKLER FINAL | 08/08/2024 | FINAL APPROVED | LMILLER |
| Note: 8/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 8/6/2024 3:51:07 PM *** 1. Need FDC Signage per NFPA 13 2. Need Riser Room Signage (exrtrerior door neer riser room needs to read FIRE SPRINKLER RISER ROOM INSIDE, and need additional signage on interior riser room reading FIRE SPRINKLER RISER ROOM) 13: 16.12.5.8.1 3. Sprinkler system Anual is out of date per NFPA1 and NFPA 13 4. Need a minimum of 12 spare sprinkler heads for systems with between 300 - 1000 heads per NFPA 13 5. Missing caps for FDCper AHJ | |||
| FIRE SPRINKLER FINAL | 08/06/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 8/6/2024 3:51:07 PM *** 1. Need FDC Signage per NFPA 13 2. Need Riser Room Signage (exrtrerior door neer riser room needs to read FIRE SPRINKLER RISER ROOM INSIDE, and need additional signage on interior riser room reading FIRE SPRINKLER RISER ROOM) 13: 16.12.5.8.1 3. Sprinkler system Anual is out of date per NFPA1 and NFPA 13 4. Need a minimum of 12 spare sprinkler heads for systems with between 300 - 1000 heads per NFPA 13 5. Missing caps for FDCper AHJ | |||
| FIRE SPRINKLER 1ST ROUGH | 08/02/2024 | APPROVED | RMARTIN |
| Note: Inspector Notes from Inspection 5100 *** NOTES ADDED BY RMARTIN 8/1/2024 2:58:49 PM *** The NOC needs to be updated to schedule rough | |||
| FIRE SPRINKLER HYDROSTATIC TEST | 08/02/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 8/1/2024 2:58:49 PM *** The NOC needs to be updated to schedule rough |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 08/01/2024 | 08/01/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM licensed contractor needs to sign the affadavit | |||
| FI1 | COMPLETE | 04/26/2024 | 04/26/2024 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 12/19/2023 | 01/02/2024 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM We do not currently have an approved permit for the changes represented here. Please resubmit after approval for the proposed changes. | |||
| UD1 | COMPLETE | 12/19/2023 | 12/28/2023 |
| Note: Released By: GREG DEGLER - - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 08/07/2024 |
| SURCHARGE FS 533.721 | ¤6.97 | 04/26/2024 |
| SURCHARGE - FS 468.631 | ¤10.45 | 04/26/2024 |
| ADJUSTMENT 50% | (¤696.70) | 04/26/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 04/26/2024 |
| INSPECTION - FIRE COMMERCIAL | ¤122.40 | 04/26/2024 |
| PLAN REVIEW - COMMERCIAL | ¤1,196.00 | 04/26/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤774.12 |