I want to search for...

Permit #2023121078

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00180-0090
CONDITIONED SPACE: 1849 sqft
GARAGE: 540 sqft
OPENED PORCH (WITH ROOF) : 308 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 2729 sqft
Block: 00180
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 386-569-7882
Location Address: 18 PONCE DELEON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/19/2024
NOC: RECORDED
Applicant name: VLADIMIR V PEREPECHKIN
Owner: PEREPECHKIN MIKHAIL & SVETLANA PEREPECHKINA JTWROS

Address

20 PONCE DE LEON DRIVE

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WISE CHOICE CUSTOM HOMES, INC.
Status Location Address State License Number Phone
ACTIVE

77 SOUTHLAKE DR

PALM COAST, FL 32137

CRC1328738 (Exp: 08/31/2026) 386-569-7882

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
ANDREW GONCALVES HOWARD
Status Location Address State License Number Phone
ACTIVE

2 RYALL LANE

PALM COAST, FL 32164

CCC1333989 (Exp: 08/31/2026) 386-347-0366

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/20/2025 FINAL APPROVED KSANDOE
Note: 2/18/2025 - PREVIOUS INSPECTION NOTES 2/18/25 Previous notes not rectified 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. New inspection due to canceled inspection 2/7/2025 - PREVIOUS INSPECTION NOTES 2/7/25: 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. Also, previously listedn items 6 and 9 remain unresolved. Additional to below, A plan revision will be required from an Engineer detailing how the water will be properly disbursed from the back side of the parapet wall based on rainfall zone for this area. 1/15/2025 - PREVIOUS INSPECTION NOTES 1/15/25: 1). Downspouts are not in columns as required on plans. Also, scuppers will be required at parapet walls where hip roof areas dump into base of parapet wall. FBC [A]107.4/ FBC-1106.5 Parapet wall scuppers. 2). Range needs to be on a GFCI breaker due to being within 6ft. of water. NEC 210.8(A)(11). 3). Service feed sleeve is not into hub and not glued. NEC-110.3(B). 4). Dryer vent gooseneck needs screen removed (must have a self closing damper). FBC M1502.3 5). Stone facade at front entry is not fully sealed at the top alowwing water to penetrate behind stone. FBC [A]107.4 6). Hole in garage wall at AHU lineset needs to be sealed. FBC EC TABLE R402.4.1.1 7). Installed units model numbers do not match listed numbers on Energy Calcs. Highlighted. FBC [A]107.4 8). Heating coil model/breakers are not identified. FBCR M1303.1 9). Guest bathtub has insufficient hot water. FBC- P2808.1 12/20/2024 - PREVIOUS INSPECTION NOTES NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
BLD - BUILDING FINAL 02/18/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 2/18/25 Previous notes not rectified 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. New inspection due to canceled inspection 2/7/2025 - PREVIOUS INSPECTION NOTES 2/7/25: 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. Also, previously listedn items 6 and 9 remain unresolved. Additional to below, A plan revision will be required from an Engineer detailing how the water will be properly disbursed from the back side of the parapet wall based on rainfall zone for this area. 1/15/2025 - PREVIOUS INSPECTION NOTES 1/15/25: 1). Downspouts are not in columns as required on plans. Also, scuppers will be required at parapet walls where hip roof areas dump into base of parapet wall. FBC [A]107.4/ FBC-1106.5 Parapet wall scuppers. 2). Range needs to be on a GFCI breaker due to being within 6ft. of water. NEC 210.8(A)(11). 3). Service feed sleeve is not into hub and not glued. NEC-110.3(B). 4). Dryer vent gooseneck needs screen removed (must have a self closing damper). FBC M1502.3 5). Stone facade at front entry is not fully sealed at the top alowwing water to penetrate behind stone. FBC [A]107.4 6). Hole in garage wall at AHU lineset needs to be sealed. FBC EC TABLE R402.4.1.1 7). Installed units model numbers do not match listed numbers on Energy Calcs. Highlighted. FBC [A]107.4 8). Heating coil model/breakers are not identified. FBCR M1303.1 9). Guest bathtub has insufficient hot water. FBC- P2808.1 12/20/2024 - PREVIOUS INSPECTION NOTES NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
BLD - BUILDING FINAL 02/12/2025 CANCELLED BY APPLICANT WEB
Note: 2/7/2025 - PREVIOUS INSPECTION NOTES 2/7/25: 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. Also, previously listedn items 6 and 9 remain unresolved. Additional to below, A plan revision will be required from an Engineer detailing how the water will be properly disbursed from the back side of the parapet wall based on rainfall zone for this area. 1/15/2025 - PREVIOUS INSPECTION NOTES 1/15/25: 1). Downspouts are not in columns as required on plans. Also, scuppers will be required at parapet walls where hip roof areas dump into base of parapet wall. FBC [A]107.4/ FBC-1106.5 Parapet wall scuppers. 2). Range needs to be on a GFCI breaker due to being within 6ft. of water. NEC 210.8(A)(11). 3). Service feed sleeve is not into hub and not glued. NEC-110.3(B). 4). Dryer vent gooseneck needs screen removed (must have a self closing damper). FBC M1502.3 5). Stone facade at front entry is not fully sealed at the top alowwing water to penetrate behind stone. FBC [A]107.4 6). Hole in garage wall at AHU lineset needs to be sealed. FBC EC TABLE R402.4.1.1 7). Installed units model numbers do not match listed numbers on Energy Calcs. Highlighted. FBC [A]107.4 8). Heating coil model/breakers are not identified. FBCR M1303.1 9). Guest bathtub has insufficient hot water. FBC- P2808.1 12/20/2024 - PREVIOUS INSPECTION NOTES NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
BLD - BUILDING FINAL 02/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/7/2025 4:31:00 PM *** 2/7/25: 1). Revision is missing information pertaining to dimensions, direction, elevation of 'Crickets' drawn on the print submitted. Also, the proposed does not match the code definition and requirement for 'Crickets' ***** FBC- R903.2.2 Crickets and saddles. A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covering. Exception: Unit skylights installed in accordance with Section R308.6 and flashed in accordance with the manufacturer’s instructions shall be permitted to be installed without a cricket or saddle. ***** 2). Scuppers are required by code for overflow water that will accumulate on the back side of the parapet wall. ***** R903.4 Roof drainage. Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. R903.4.1 Overflow drains and scuppers. When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. 3). Down spouts (3" x 4" with 6" gutters) at the front of the house along with gutters do not meet the size requirements to affectively disperse water as required by Florida Plumbing Code for the Rainfall zone and parapet wall layout that this house falls under. Also, previously listedn items 6 and 9 remain unresolved. Additional to below, A plan revision will be required from an Engineer detailing how the water will be properly disbursed from the back side of the parapet wall based on rainfall zone for this area. 1/15/2025 - PREVIOUS INSPECTION NOTES 1/15/25: 1). Downspouts are not in columns as required on plans. Also, scuppers will be required at parapet walls where hip roof areas dump into base of parapet wall. FBC [A]107.4/ FBC-1106.5 Parapet wall scuppers. 2). Range needs to be on a GFCI breaker due to being within 6ft. of water. NEC 210.8(A)(11). 3). Service feed sleeve is not into hub and not glued. NEC-110.3(B). 4). Dryer vent gooseneck needs screen removed (must have a self closing damper). FBC M1502.3 5). Stone facade at front entry is not fully sealed at the top alowwing water to penetrate behind stone. FBC [A]107.4 6). Hole in garage wall at AHU lineset needs to be sealed. FBC EC TABLE R402.4.1.1 7). Installed units model numbers do not match listed numbers on Energy Calcs. Highlighted. FBC [A]107.4 8). Heating coil model/breakers are not identified. FBCR M1303.1 9). Guest bathtub has insufficient hot water. FBC- P2808.1 12/20/2024 - PREVIOUS INSPECTION NOTES NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
BLD - BUILDING FINAL 01/15/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/15/2025 11:47:35 AM *** 1/15/25: 1). Downspouts are not in columns as required on plans. Also, scuppers will be required at parapet walls where hip roof areas dump into base of parapet wall. FBC [A]107.4/ FBC-1106.5 Parapet wall scuppers. 2). Range needs to be on a GFCI breaker due to being within 6ft. of water. NEC 210.8(A)(11). 3). Service feed sleeve is not into hub and not glued. NEC-110.3(B). 4). Dryer vent gooseneck needs screen removed (must have a self closing damper). FBC M1502.3 5). Stone facade at front entry is not fully sealed at the top alowwing water to penetrate behind stone. FBC [A]107.4 6). Hole in garage wall at AHU lineset needs to be sealed. FBC EC TABLE R402.4.1.1 7). Installed units model numbers do not match listed numbers on Energy Calcs. Highlighted. FBC [A]107.4 8). Heating coil model/breakers are not identified. FBCR M1303.1 9). Guest bathtub has insufficient hot water. FBC- P2808.1 12/20/2024 - PREVIOUS INSPECTION NOTES NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
BLD - BUILDING FINAL 12/20/2024 Disapproved - NO FEE KSANDOE
Note: NEC 230.67 whole house surge protection required at main panel outside. Plumbing fixtures with contruction debris cannot be tested. Please remove all foreign material. Kitchen island outlet location Full inspection required do not see internal downspouts at Building front parapet walls as required on prints. Check at this inspection.
ROW - FINAL APRON (AFTER POUR) 11/15/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 11/15/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 11/14/2024 FINAL APPROVED LFITZGERALD
U-CROSS CONNECTION 11/14/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 11/14/2024 10:41:17 AM *** potable irrigation with PVB -no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/13/2024 APPROVED EMADISON
Note: ** 11/13/24 fFINAL GRADE WAS BUILT AND MATCHES THE APPROVED SITE PLAN
ROW FIELD SURVEY /GRADING CERTIFICATION 11/13/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ELECTRIC - EARLY POWER 09/23/2024 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/23/2024 9:06:39 AM *** 9/23/24: FPL emailed to release power.
ROW- PRE-APRON (PRE-POUR) 08/28/2024 APPROVED - AS NOTED FSLADISH
Note: 8/28/24 PIPE ELEVATION IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
GRAVITY SEWER TEST 08/09/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 2/15/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING PROTECTION OF PROPERTY 3307.1 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION
SEWER TIE IN 08/09/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 2/15/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING PROTECTION OF PROPERTY 3307.1 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION
PEP TANK INSTALLATION REQUEST 07/25/2024 APPROVED CBOWERMASTER
INSULATION 07/12/2024 APPROVED BTAYLOR
ALL ROUGH 07/08/2024 APPROVED LMILLER
Note: *** NOTES ADDED BY LMILLER 7/8/2024 8:29:50 AM *** prior notes resolved 7/1/2024 - PREVIOUS INSPECTION NOTES 7/1/24: Incomplete inspection because revised Energy Calcs still do not match installed ductwork. Full ductwork inspection required. * Previously listed item 2: exhausts are missing the mechanical seal as required and previously noted. 6/13/2024 - PREVIOUS INSPECTION NOTES 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). All Bathroom Exhaust Fans: Need 3" duct work changed to 4" as the 3" duct does not carry the minimum 50CFMs as required. If 3" fans remain you will need to intall a 4" x 3" adapter at the fan which will require 2 points of connection (1 mechanical & 1 seal - mastic or tape). 3). Slab trench for electric feed to Kitchen Island needs to be repaired with cement to bring it to slab finished height. 4). SGDs and Master Bedroom exterior door are missing the Florida Product Approved stickers as required for inspection. 5). Lineset is not installed through the sleeve and the sleeve sealed. (This will be hidden after drywall). 6). Need a dumpster on site. 7). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.)
ALL ROUGH 07/01/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/1/24: Incomplete inspection because revised Energy Calcs still do not match installed ductwork. Full ductwork inspection required. * Previously listed item 2: exhausts are missing the mechanical seal as required and previously noted. 6/13/2024 - PREVIOUS INSPECTION NOTES 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). All Bathroom Exhaust Fans: Need 3" duct work changed to 4" as the 3" duct does not carry the minimum 50CFMs as required. If 3" fans remain you will need to intall a 4" x 3" adapter at the fan which will require 2 points of connection (1 mechanical & 1 seal - mastic or tape). 3). Slab trench for electric feed to Kitchen Island needs to be repaired with cement to bring it to slab finished height. 4). SGDs and Master Bedroom exterior door are missing the Florida Product Approved stickers as required for inspection. 5). Lineset is not installed through the sleeve and the sleeve sealed. (This will be hidden after drywall). 6). Need a dumpster on site. 7). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.)
LATH/BRICK/ WATER BARRIER 06/20/2024 APPROVED KSANDOE
ALL ROUGH 06/13/2024 Disapproved -FEE REQUIRED RSIMS
Note: 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). All Bathroom Exhaust Fans: Need 3" duct work changed to 4" as the 3" duct does not carry the minimum 50CFMs as required. If 3" fans remain you will need to intall a 4" x 3" adapter at the fan which will require 2 points of connection (1 mechanical & 1 seal - mastic or tape). 3). Slab trench for electric feed to Kitchen Island needs to be repaired with cement to bring it to slab finished height. 4). SGDs and Master Bedroom exterior door are missing the Florida Product Approved stickers as required for inspection. 5). Lineset is not installed through the sleeve and the sleeve sealed. (This will be hidden after drywall). 6). Need a dumpster on site. 7). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.)
ROOF VALLEY & METAL 05/24/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2450 5/10/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. (FBC-3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) ___
WALL SHEATHING 05/10/2024 APPROVED - AS NOTED RSIMS
Note: 5/10/24: Approved as noted to keep project moving. MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. (FBC-3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) ___
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/30/2024 APPROVED BTAYLOR
Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 4/16/24: Inspection stopped! * Parapet wall does not match detail on page 1A which list smooth stucco over CMU. The built wall is wood framed and the plans do not have any details for wood framed parapet wall. Revision needed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/16/2024 Disapproved - NO FEE RSIMS
Note: 4/16/24: Inspection stopped! * Parapet wall does not match detail on page 1A which list smooth stucco over CMU. The built wall is wood framed and the plans do not have any details for wood framed parapet wall. Revision needed.
TIE BEAM / LINTEL 03/05/2024 APPROVED MKRASKI
TIE BEAM / LINTEL 03/04/2024 Disapproved - NO FEE MKRASKI
Note: dowel not tied to down rod, front left corner of garage marked on print
FOUND SURVEY APPROVED (OFFICE) 03/01/2024 APPROVED TBAKER
MONOLITHIC SLAB 02/21/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 02/16/2024 APPROVED - AS NOTED MGIBSON
Note: 2/15/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING PROTECTION OF PROPERTY 3307.1 NEED TO HAVE SILT FENCE IN PLACE BEFORE SLAB INSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 02/15/2024 Disapproved -FEE REQUIRED MGIBSON
Note: PLUMBERS STILL WORKING
WATER METER INSTALLATION REQUEST 02/02/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
BLD COMPLETE 05/14/2025 05/14/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD HOLD 05/08/2025 05/14/2025
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-RESIDENTIAL. 1. OK 2. OK 3. OK 4. OK 5. OK 6. 3RD REPEAT COMMENT. THIS TIME NO CITY OF PALM COAST ROOFING WORKSHEET WAS UPLOADED AS REQUESTED TWO TIMES BEFORE: REPEAT COMMENT. THE ROOFING WORKSHEET UPLOADED TO THE PERMIT INCLUDES A FLORIDA PRODUCT APPROVAL NUMBER FOR THE ASPHALT SHINGLES BUT NO APPROVAL NUMBER OR MANUFACTURER FOR THE ROOFING INSTALLED ON THE LOW SLOPE PORTIONS OF THE ROOF. Upload City of Palm Coast Roofing Worksheet. Provide Florida Product Approval Numbers or Miami-Dade County NOA numbers for all roofing material types and all roofing underlayment material types. A roofing worksheet was not provided when the permit was applied for. We have no record of roofing materials used. We need approval numbers for all roofing types. For the NOA Flintastic product there are about five different types shown. Circle the one you used.
BADMIN INFORMATION 05/08/2025 05/08/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME FILE NAMES TO 1A.PDF, 2.PDF, ...
BLD HOLD 04/25/2025 04/25/2025
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-RESIDENTIAL. 1. REPEAT COMMENT. A DESCRIPTION OF THE FUNCTION AND INTENT OF THE PARAPET WALL AND LOW SLOPE ROOF HAS BEEN PROVIDED AND IS HELPFUL, BUT BY ITSELF, IT DOES NOT ADDRESS THIS COMMENT OR COMMENT NO. 2 AND NO.4 BELOW. SEE ADDED NOTES UNDER EACH OF THOSE COMMENTS. The Roof Plan Sheets 1A/6, 1/6 and truss layout plan does not match the as-built conditions of the roof. Plan does not depict change from high slope roofs to low slope roofs in close proximity to parapet wall. Plans do not show complete construction details how low slope roof sections were constructed. These plan sheets must be revised to show actual design / as-built conditions. 2. REPEAT COMMENT. DETAIL 1/F STILL DOES NOT SHOW COMPLETE CONSTRUCTION DETAILS OF PARAPET WALL, TRUSS AND / OR OVER-FRAMING DETAILS FOR THE LOW-SLOPE PORTIONS OF THE ROOF ADJACENT TO THE PARAPET WALL. YOU MUST SHOW ROOF TO WALL FLASHING DETAIL, PARAPET WALL COPING CAP AND COUNTER-FLASHING DETAIL USING NON-COMBUSTIBLE CAP AND COUNTER FLASHING MATERIALS ALONG WITH FASTENING SCHEDULE. YOU MUST SHOW ROOF TRUSS BEARING DETAIL ON CMU WALL IN RELATION TO THE PARAPET WALL. Plan Sheet 1/6 (Detail I/F) does not show complete construction details of parapet wall or truss or over-framing details for the low-slope portions of the roof adjacent to parapet wall. Show roof to wall flashing detail. Show parapet wall coping cap and counter-flashing detail including noncombustible cap and counter flashing materials and fastening schedule. Show roof truss bearing detail on CMU wall in relation to parapet wall. Truss layout plan calls out trusses to be held back 4 inches from outside face of block wall – show this in Detail 1/F. 3. THIS COMMENT APPEARS TO BE ADDRESSED BY WAY OF THE COMMENTARY PROVIDED ON PLAN SHEET 1A/6. Pictures and video of roof clearly indicate inside corners created by parapet walls with roof slopes in two directions converging in corners. How is stormwater going to transition directions and cross over roof hips and remain below bottom of stucco? Water will stack up in these corners until the water can change direction and continue flowing to the ends of the parapet wall. Roof coverings used on roof hips aren’t designed for slow roof drainage and ponding water. Your engineer will need to evaluate these conditions and provide design solutions to get water off the roof. 4. REPEAT COMMENT. LOW SLOPE ROOF CONSTRUCTION OVER-FRAMING DETAILS NOT PROVIDED IN PLAN VIEW. NO DETAILS PROVIDED FOR FRAMING MEMBERS, ON-CENTER SPACING, LUMBER SIZES, GRADES AND SPECIES OR SPANS. NO FASTENING DETAILS FOR OVER-FRAMING TO TRUSS AND PARAPET WALLS PROVIDED. NO DETAIL PROVIDED FOR FLASHING BETWEEN ASPHALT SHINGLE PORTION OF ROOF AND LOW SLOPE ROOF COVERING. NO DETAILS FOR ROOF COVERING OR UNDERLAYMENT. Truss profile drawings do not show any low slope truss sections for low slope roof section. How were the low slope sections constructed? Provide framing / over-framing details. Provide details in plan view and section views for a complete design. Show framing members, on-center spacing, lumber sizes, grades and species. Fastening details for over-framing to truss connections. Show roof slopes for low slope roof sections towards parapet wall and parallel to parapet wall. Slopes appear to change in different parts of the roof based on our site inspections. Show as-built slopes for each section. Show roof decking. Show transition flashing used between higher sloped roof sections and low slope roof sections Show flashing and sealant details at connection with parapet wall. Specify underlayment type. Specify roof covering type. These are very low slope roofs and you will need to specify roof covering types approved for less than 1/4 inch per foot slopes. 5. REPEAT COMMENT. GUTTERS AND DOWNSPOUTS STILL NOT SIZED AS REQUESTED. DUE TO THE PRESENCE OF THE PARAPET WALL, ROOF RUN-OFF IS CONCENTRATED AND DISCHARGED AT A NARROW POINT OFF EACH END OF THE ROOF AS OPPOSED TO SHEET FLOWING OFF THE ROOF INTO AN OPEN GUTTER. THIS CONCENTRATED FLOW WILL OVERFLOW THE GUTTER AND DOWNSPOUT AND THEY NEED TO BE ENLARGED TO CAPTURE AND CONTROL THE CONCENTRATED FLOW. Gutters and downspouts are not sized to accept concentrated roof run-off at ends of parapet walls. Gutters and downspouts will need to be increased in sizes to accommodate concentrated water flows. Engineer to provide design. 6. REPEAT COMMENT. THE ROOFING WORKSHEET UPLOADED TO THE PERMIT INCLUDES A FLORIDA PRODUCT APPROVAL NUMBER FOR THE ASPHALT SHINGLES BUT NO APPROVAL NUMBER OR MANUFACTURER FOR THE ROOFING INSTALLED ON THE LOW SLOPE PORTIONS OF THE ROOF. Upload City of Palm Coast Roofing Worksheet. Provide Florida Product Approval Numbers or Miami-Dade County NOA numbers for all roofing material types and all roofing underlayment material types. A roofing worksheet was not provided when the permit was applied for. We have no record of roofing materials used. We need approval numbers for all roofing types. For the NOA Flintastic product there are about five different types shown. Circle the one you used.
BLD COMPLETE 04/09/2025 04/14/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 01/30/2025 02/04/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2025 01/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 12/10/2024 12/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 06/26/2024 06/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/23/2024 04/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 04/23/2024 04/29/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 03/22/2024 03/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/01/2024 03/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/01/2024 03/01/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ELEC COMPLETE 01/16/2024 01/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 01/09/2024 01/11/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 2. Need correct outlet spacing in master bedroom. NEC 2017 210.52
LOCATE COMPLETE 01/09/2024 01/09/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
SW1 COMPLETE 01/09/2024 01/17/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 01/09/2024 01/09/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 12/28/2023 02/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2023 12/28/2023
Note: Released By: JPI
CUSVC COMPLETE 12/27/2023 12/28/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 12/27/2023 12/28/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Outlets in laundry, garage need to be GFCI protected. NEC 2017 210.8 2. Need correct outlet spacing in master bedroom. NEC 2017 210.52 3. DW outlet can not be behind the DW. NEC 2017 422.16 4. Need light switch in master bedrom for exterior lights. NEC 2017 210.70 5. Need to add outlet in garage. NEC 2017 210.52 (G) (1)
ENGIN1 COMPLETE 12/27/2023 12/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 12/27/2023 01/04/2024
LOCATE REJECT 12/27/2023 12/31/2023
Note: Rejected By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM Need Locate
MECH COMPLETE 12/27/2023 01/04/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 COMPLETE 12/27/2023 01/04/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
ZON COMPLETE 12/27/2023 12/27/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 12/27/2023 12/29/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 05/20/2025
PLAN REVIEW - REVISION ¤32.50 04/09/2025
PLAN REVIEW - REVISION ¤32.50 04/09/2025
PLAN REVIEW - REVISION ¤32.50 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
REINSPECTION RESIDENTIAL ¤40.00 04/09/2025
CONTRACTOR CHANGE ¤40.00 04/09/2025
FC IMPACT FEE EMS ¤62.00 01/19/2024
IMPACT FEE FIRE ¤428.09 01/19/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/19/2024
FC IMPACT FEE LIBRARY ¤268.00 01/19/2024
IMPACT FEE PARKS ¤1,800.99 01/19/2024
IMPACT FEE SCHOOL ¤5,450.00 01/19/2024
IMPACT FEE TRANSPORTATION ¤1,812.00 01/19/2024
WATER -IRRIGATION INSPECTION ¤25.00 01/19/2024
SURCHARGE FS 533.721 ¤3.73 01/19/2024
SURCHARGE - FS 468.631 ¤5.59 01/19/2024
SW ENG - FOUNDATION SURVEY ¤20.00 01/19/2024
SW ENG INSPECTION 80 ¤80.00 01/19/2024
SW ENG PRE APRON ¤30.00 01/19/2024
SW ENG - REVIEW 20 ¤20.00 01/19/2024
SW ENG RES REVIEW 200 ¤200.00 01/19/2024
SEWER INSPECTION ¤25.00 01/19/2024
SEWER CAPITAL FACILITY ¤5,441.03 01/19/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 01/19/2024
SITE PLAN 30 ¤30.00 01/19/2024
CONNECTION FEES ¤1,187.26 01/19/2024
INSPECTION - RESIDENTIAL ¤998.25 01/19/2024
PLAN REVIEW - RESIDENTIAL ¤283.14 01/19/2024
WATER- TURN ON ¤25.00 01/19/2024
ADJUSTMENT 50% (¤655.70) 01/19/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/19/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,199.39