Permit #2023121092

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00350-0060
CONDITIONED SPACE: 2306 sqft
GARAGE: 466 sqft
OPENED PORCH (WITH ROOF) : 170 sqft
Total Square Footage: 2942 sqft
Block: 00350
Subdivision: -
Job Phone: 831-383-2883
Location Address: 48 KATHLEEN TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/16/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

PO BOX 770279

ORLANDO , FL 32877

Lot: 0060
Contracted Stated Job Value: ¤277,000.00
Job Description: Single Family Residence
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CFC1430061 (Exp: 08/31/2026) 407-404-4000
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/26/2024 FINAL APPROVED MKRASKI
U -UTILITY RESIDENTIAL FINAL 09/26/2024 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 IRR with potable water. PVB in place. No CC.
ROW - STORMWATER FINAL 09/25/2024 APPROVED - AS NOTED FSLADISH
Note: 9/25/24 WE HAVE HAD A LOT OF RAIN LATELY, SOD IN SWALE IS SATURATED AND BROWN BUT SURVEY SHOWS POSITIVE DRAINAGE. I WILL DEFER TO THE SIGNED AND SEALED LEGAL SURVEY DOCUMENT AS A INDICATION THAT SWALE HAS FLOW. AT THE TIME OF THIS THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 09/25/2024 APPROVED FSLADISH
Note: 9/25/24 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 09/23/2024 APPROVED - AS NOTED BWRIGHT
Note: IRR with potable water. PVB in place. No CC.
U -UTILITY RESIDENTIAL FINAL 09/23/2024 Disapproved - NO FEE BWRIGHT
Note: No Power to the PeP tank.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/19/2024 APPROVED FSLADISH
Note: 9/18/2024 - PREVIOUS INSPECTION NOTES 9/18/24 You must submit a new final survey now that you have submitted a revised site plan. Your revised site plan was approved on 9/16/24 Your latest final survey was submitted on 9/13/24. Inspector Notes from Inspection 9270 8/19/24 PIPE ELEVATION IS GOOD. SPOKE WITH DAN CM AND LET HIM KNOW WE WOULD NEED A REVISED SITE PLAN SHOWING THE NEW DRIVEWAY CONFIGURATION. LAYOUT WILL WORK AND CONFORMS TO COPC DRIVEWAY STANDARDS AT THE TIME OF THIS INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/19/2024 APPROVED FSLADISH
Note: 9/19/24 UPON WALKING PROPERTY DETERMINED THAT DRAINAGE WILL WORK AS INDICATED. THERE ARE A FEW WASHOUTS BY THE CULVERT PIPE WHICH IS FULL OF DIRT/SILT. THE CULVERT PIPE WILL NEED TO BE FULLY CLEANED OUT AND WASHOUTS FIXED BEFORE FOW FINAL.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/18/2024 Disapproved - NO FEE FSLADISH
Note: 9/18/24 You must submit a new final survey now that you have submitted a revised site plan. Your revised site plan was approved on 9/16/24 Your latest final survey was submitted on 9/13/24. Inspector Notes from Inspection 9270 8/19/24 PIPE ELEVATION IS GOOD. SPOKE WITH DAN CM AND LET HIM KNOW WE WOULD NEED A REVISED SITE PLAN SHOWING THE NEW DRIVEWAY CONFIGURATION. LAYOUT WILL WORK AND CONFORMS TO COPC DRIVEWAY STANDARDS AT THE TIME OF THIS INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ELECTRIC - EARLY POWER 09/11/2024 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2200 Release Power 9-11-24 1. Emailed FPL at 12:37.
FLOOR / WALL PENETRATION 09/11/2024 APPROVED BTAYLOR
ROW- PRE-APRON (PRE-POUR) 08/19/2024 APPROVED - AS NOTED FSLADISH
Note: 8/19/24 PIPE ELEVATION IS GOOD. SPOKE WITH DAN CM AND LET HIM KNOW WE WOULD NEED A REVISED SITE PLAN SHOWING THE NEW DRIVEWAY CONFIGURATION. LAYOUT WILL WORK AND CONFORMS TO COPC DRIVEWAY STANDARDS AT THE TIME OF THIS INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
GRAVITY SEWER TEST 08/15/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 08/15/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 08/01/2024 APPROVED CBOWERMASTER
INSULATION 07/26/2024 APPROVED KSANDOE
Note: 7/25/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 7-15-24 1. No windows installed. Windows are on back order. 7-25-24 1. Windows are not insulated.
LATH/BRICK/ WATER BARRIER 07/26/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2420 7-15-24 1. No windows installed. Windows are on back order.
INSULATION 07/25/2024 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2420 7-15-24 1. No windows installed. Windows are on back order. 7-25-24 1. Windows are not insulated.
ALL ROUGH 07/15/2024 APPROVED - AS NOTED BTAYLOR
Note: 7-15-24 1. No windows installed. Windows are on back order.
ROOF VALLEY & METAL 07/11/2024 APPROVED BTAYLOR
Note: 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: 1). Piles of trash & debris at front of property need to be cleaned up and placed in dumpster. 2). 5" x 5" flashing needs to be sealed to CMU along top leg as required.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/09/2024 APPROVED RSIMS
Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/2/24: 1). 3Ply truss T01T is not connected as required on MiTek. Marked on MiTek. 2). 2ply Trusses T24 & T25 are not connected as required on MiTek. Marked on MiTek. 3). Overvalley framing straps: some are too short and all are not connected at bottom as required.
ROOF VALLEY & METAL 07/09/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/9/24: 1). Piles of trash & debris at front of property need to be cleaned up and placed in dumpster. 2). 5" x 5" flashing needs to be sealed to CMU along top leg as required.
WALL SHEATHING 07/02/2024 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/02/2024 Disapproved - NO FEE RSIMS
Note: 7/2/24: 1). 3Ply truss T01T is not connected as required on MiTek. Marked on MiTek. 2). 2ply Trusses T24 & T25 are not connected as required on MiTek. Marked on MiTek. 3). Overvalley framing straps: some are too short and all are not connected at bottom as required.
ELECTRIC-TUG 06/27/2024 APPROVED - AS NOTED KSANDOE
Note: Release Power
FOUND SURVEY APPROVED (OFFICE) 06/27/2024 APPROVED TBAKER
TIE BEAM / LINTEL 06/21/2024 APPROVED BTAYLOR
MONOLITHIC SLAB 06/12/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 06/07/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 05/30/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 09/17/2024 09/17/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/17/2024 09/17/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON COMPLETE 09/17/2024 09/17/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/10/2024 07/10/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2024 07/10/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/27/2024 06/27/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/27/2024 06/27/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 05/03/2024 05/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/19/2024 04/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
ENGIN1 COMPLETE 04/08/2024 04/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/08/2024 04/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/08/2024 04/08/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 04/08/2024 05/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2023 12/28/2023
Note: Released By: JPI
CUSVC COMPLETE 12/27/2023 12/28/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 12/27/2023 12/28/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 HOLD 12/27/2023 12/28/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No benchmark on survey
GAS CANCEL 12/27/2023 12/28/2023
LOCATE COMPLETE 12/27/2023 12/31/2023
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/27/2023 01/04/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 HOLD 12/27/2023 01/04/2024
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please show and I D site Bench Mark, Drainage from structure to be minimum 6" slope for the first 10' (i e rear of house)
ZON COMPLETE 12/27/2023 12/28/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 12/27/2023 12/28/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 09/26/2024
PLAN REVIEW - REVISION ¤32.50 09/26/2024
REINSPECTION RESIDENTIAL ¤40.00 09/26/2024
CONNECTION FEES ¤1,187.26 04/16/2024
WATER-METER ¤514.49 04/16/2024
WATER- TURN ON ¤25.00 04/16/2024
WATER- TURN ON ¤25.00 04/16/2024
ADJUSTMENT 50% (¤761.60) 04/16/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/16/2024
INSPECTION - RESIDENTIAL ¤1,163.25 04/16/2024
PLAN REVIEW - RESIDENTIAL ¤329.94 04/16/2024
FC IMPACT FEE EMS ¤62.00 04/16/2024
IMPACT FEE FIRE ¤428.09 04/16/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/16/2024
FC IMPACT FEE LIBRARY ¤268.00 04/16/2024
IMPACT FEE PARKS ¤1,800.99 04/16/2024
IMPACT FEE SCHOOL ¤5,450.00 04/16/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/16/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/16/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/16/2024
SURCHARGE FS 533.721 ¤7.62 04/16/2024
SURCHARGE - FS 468.631 ¤11.42 04/16/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/16/2024
SW ENG INSPECTION 80 ¤80.00 04/16/2024
SW ENG PRE APRON ¤30.00 04/16/2024
SW ENG - REVIEW 20 ¤20.00 04/16/2024
SW ENG RES REVIEW 200 ¤200.00 04/16/2024
SEWER INSPECTION ¤25.00 04/16/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/16/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/16/2024
SITE PLAN 30 ¤30.00 04/16/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,604.50