I want to search for...

Permit #2024010833

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01530-0080
CONDITIONED SPACE: 1876 sqft
GARAGE: 414 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 2358 sqft
Block: 01530
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 904-268-7730
Location Address: 3 BIRCH HAVEN PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/27/2024
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FOCUS HOMES LLC

Address

5220 SHAD ROAD

JACKSONVILLE, FL 32257

Lot: 0080
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
DANIEL GREGORY PUGLISI
Status Location Address State License Number Phone
INACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13011195 (Exp: 08/31/2024) 407-302-7800
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
GARY CARMACK
Status State License Number
CANCEL CAC043900 (Exp: 08/31/2010)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/19/2024 FINAL APPROVED JSTEWART
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 9:24:40 AM *** 1. Please remove screen at dryer exhaust. FBC M1502.3 2. Please seal wall Penetration at power. (ground conduit) FBC R402.4 3. Please install surge protection per NEC ARTICLE 230.67 4. Please install GFCI Breaker for dryer Receptacle Per NEC ARTICLE 210.8
BLD - BUILDING FINAL 07/18/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 7/18/2024 9:24:40 AM *** 1. Please remove screen at dryer exhaust. FBC M1502.3 2. Please seal wall Penetration at power. (ground conduit) FBC R402.4 3. Please install surge protection per NEC ARTICLE 230.67 4. Please install GFCI Breaker for dryer Receptacle Per NEC ARTICLE 210.8
U -UTILITY RESIDENTIAL FINAL 07/17/2024 FINAL APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 07/16/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/16/2024 APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9270 ** 06/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ROW FIELD SURVEY /GRADING CERTIFICATION 07/16/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 07/16/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U-CROSS CONNECTION 07/03/2024 APPROVED DHANEY
ROW- PRE-APRON (PRE-POUR) 06/24/2024 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 06/18/2024 APPROVED - AS NOTED EMADISON
Note: ** 06/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 06/10/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 6/10/2024 11:54:13 AM *** NOTE: Please install surge protection per NEC ARTICLE 230.67 Please install GFCI breaker for locations of Range, Dryer, etc per NEC ARTICLE 210.8 Before Building Final inspection. Inspector Notes from Inspection 2200 4/18/24- Authorize release of email to FPL @ 9:18a
SEWER TIE IN 06/04/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 05/10/2024 APPROVED CBOWERMASTER
INSULATION 05/06/2024 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 05/02/2024 APPROVED FWILLIS
Note: 5/1/2024 - PREVIOUS INSPECTION NOTES ON SITE AT 1:17PM, 2 FPL TRUCKS WITH BOOMS EXTENDED WORKING ON WIRES. COULD NOT GET DOWN TO HOUSE. WALKING WAS CUT OFF TOO. RESCHEDULE FOR TOMORROW, THANKS.
ALL ROUGH 05/01/2024 APPROVED - AS NOTED JSTEWART
Note: 5/1/24- 1. Please install nail plates at the following water supply for exterior nailing protection. Laundry, refridgerator, and master toilet room.P2603.2.1… PROTECTION AGAINST PHYSICAL DAMAGE 2. Please install approved nail plate at the tp of laundry vent stack. P2603.2.1… PROTECTION AGAINST PHYSICAL DAMAGE… AND SHALL EXTEND NO LESS THAN 2 inches ABOVE SOLE PLATES AND BELOW TOP PLATES 3. Please install nail plates at island wall. WILL CHECK AT INSULATION
LATH/BRICK/ WATER BARRIER 05/01/2024 CANCELLED BY APPLICANT FWILLIS
Note: ON SITE AT 1:17PM, 2 FPL TRUCKS WITH BOOMS EXTENDED WORKING ON WIRES. COULD NOT GET DOWN TO HOUSE. WALKING WAS CUT OFF TOO. RESCHEDULE FOR TOMORROW, THANKS.
ROOF VALLEY & METAL 04/23/2024 APPROVED JSTEWART
ELECTRIC-TUG 04/18/2024 APPROVED - AS NOTED JSTEWART
Note: 4/18/24- Authorize release of email to FPL @ 9:18a
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/17/2024 APPROVED FWILLIS
ROOF SHEATHING 04/16/2024 APPROVED FWILLIS
WALL SHEATHING 04/16/2024 APPROVED FWILLIS
MONOLITHIC SLAB 04/02/2024 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 04/01/2024 APPROVED TBAKER
PLUMBING 1ST ROUGH UNDERGROUND 03/28/2024 APPROVED - AS NOTED MGIBSON
Note: NEED TO CHANGE PLUMBING SUB-CONTRACTOR
GRAVITY SEWER TEST 03/28/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/26/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 03/07/2024 APPROVED CBOWERMASTER
Note: 3/6/2024 7:27:30 AM- PREVIOUS INSPECTION NOTES STILL CLEARING
WATER METER INSTALLATION REQUEST 03/05/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: STILL CLEARING

Review History

Department Status Date In Date Out
MECH COMPLETE 05/09/2024 05/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/06/2024 05/08/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
ENGIN1 COMPLETE 03/28/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2024 03/28/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 03/25/2024 03/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 03/20/2024 03/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter must be accompanied by a signed and sealed inspection and certification letter by the geotechnical engineer of record. Engineer’s letter to confirm the following: Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4)
ELEC COMPLETE 02/22/2024 02/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 02/22/2024 02/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/22/2024 02/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/22/2024 02/23/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/13/2024 02/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 02/13/2024 02/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 02/13/2024 02/21/2024
Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM 1- Drainage from the structure is to be a 6 inch minimum slope for the first 10’ (from 24.50 points on the back of the structure to 24.20 point). Please revise your FFE and structure elevations or drainage design. 2- When adjacent to an improved lot, you must match the elevations. On the property line (adjacent to Lot 9 Block 153), there are some points that appear to be proposed elevations, please revise or clarify.
BADMIN COMPLETE 02/13/2024 02/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/13/2024 02/13/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/13/2024 02/13/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC HOLD 02/13/2024 02/15/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical load calculation are done by a electrician that is not listed on your permit.
BADMIN HOLD 01/23/2024 01/30/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. If report determines unsuitable sub-surface conditions or unsuitable soil conditions, then engineer shall provide a soils mitigation plan in order to ensure soils are suitable to receive the building's foundation. Report to include fill and compaction specifications and engineering inspection requirements. At conclusion of any soils mitigation work, engineer will be required to certify work was performed according to plans. Be advised, if the geotechnical report reveals any unsuitable soils and / or subsurface conditions, the first inspection for this permit (1st Rough / Underground Plumbing) will be HELD until such time as a report by the geotechnical engineer is submitted to the Building Division documenting that the soil mitigation work has been completed according to the engineer's plans and is now suitable for construction. Report must also include a record of all required compaction testing.
BLD HOLD 01/23/2024 01/25/2024
Note: Held By: JPI 1) The Geotechnical Report appears to be missing from the file directory. FBC 1603
CUSVC COMPLETE 01/23/2024 01/26/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 01/23/2024 01/23/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical load calculation are doen by a electrican that is not listed on your permit. 2. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 01/23/2024 01/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 01/23/2024 01/26/2024
LOCATE COMPLETE 01/23/2024 01/25/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 01/23/2024 01/26/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition
SW1 HOLD 01/23/2024 01/30/2024
Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM 1- Finished floor elevations should not exceed 10 inches higher than the lowest adjacent property finished floor elevation (Lot 9 block 153 = 24.87). Please revise your proposed finished floor elevation and grading accordingly. 2- Please include the inverts of adjacent improved property driveway culvert (Lot 9 Block 153)
ZON COMPLETE 01/23/2024 01/24/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 01/23/2024 03/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/19/2024
REINSPECTION RESIDENTIAL ¤40.00 07/19/2024
CONTRACTOR CHANGE ¤20.00 07/19/2024
CONTRACTOR CHANGE ¤20.00 07/19/2024
REINSPECTION FEE ¤40.00 07/19/2024
SURCHARGE FS 533.721 ¤6.19 02/27/2024
SURCHARGE - FS 468.631 ¤9.28 02/27/2024
SW ENG - FOUNDATION SURVEY ¤20.00 02/27/2024
SW ENG INSPECTION 80 ¤80.00 02/27/2024
SW ENG PRE APRON ¤30.00 02/27/2024
SW ENG - REVIEW 20 ¤20.00 02/27/2024
SW ENG RES REVIEW 200 ¤200.00 02/27/2024
SEWER CREDIT (¤850.00) 02/27/2024
SEWER INSPECTION ¤25.00 02/27/2024
SEWER CAPITAL FACILITY ¤5,441.03 02/27/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 02/27/2024
SITE PLAN 30 ¤30.00 02/27/2024
FC IMPACT FEE EMS ¤62.00 02/27/2024
IMPACT FEE FIRE ¤428.09 02/27/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/27/2024
FC IMPACT FEE LIBRARY ¤268.00 02/27/2024
IMPACT FEE PARKS ¤1,800.99 02/27/2024
IMPACT FEE SCHOOL ¤5,450.00 02/27/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 02/27/2024
WATER -IRRIGATION INSPECTION ¤25.00 02/27/2024
CONNECTION FEES ¤1,187.26 02/27/2024
CONTRACTOR CHANGE ¤20.00 02/27/2024
WATER- TURN ON ¤25.00 02/27/2024
ADJUSTMENT 50% (¤618.63) 02/27/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/27/2024
INSPECTION - RESIDENTIAL ¤940.50 02/27/2024
PLAN REVIEW - RESIDENTIAL ¤266.76 02/27/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,123.48