Permit #2024010851

Permit Details

Status: COED

Parcel Id: 35-11-31-4075-00000-1040
CONDITIONED SPACE: 2169 sqft
GARAGE: 436 sqft
SCREEN PORCH (SOLID ROOF) : 351 sqft
OPENED PORCH (WITH ROOF) : 169 sqft
Total Square Footage: 3125 sqft
Block: 00000
Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION
Job Phone: 863-647-5815
Location Address: 73 DEL PALMA DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/27/2024
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: THOMPSON ROBERT & MAUREEN H&W

Address

7 CAMBRIDGE ROAD

FREEHOLD, NJ 07728

Lot: 1040
Contracted Stated Job Value: ¤455,000.00
Job Description: Single Family Residence
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

MOISES MERINO DIAZ
Status Location Address State License Number Phone
ACTIVE

3104 ORANOLE ROAD

ORLANDO, FL 32810

CAC1820980 (Exp: 08/31/2026) 407-225-3149
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
IAN ALAN BRENNER
Status Location Address Mailing Address State License Number Phone
ACTIVE

691 GARDEN COMMERCE PKWY

WINTER GARDEN, FL 34787

STE 170

WINTER GARDEN, FL 34787

CCC1331270 (Exp: 08/31/2026) 407-649-1333

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/18/2024 FINAL APPROVED KSANDOE
Note: 11/15/2024 - PREVIOUS INSPECTION NOTES Updated energy calcs required 11/12/2024 - PREVIOUS INSPECTION NOTES 11/8/2024 - PREVIOUS INSPECTION NOTES 11/6/2024 - PREVIOUS INSPECTION NOTES 11-8-24 1. No energy cals. 2. Hole in attic from garage to house needs to be repaired. 3. No hot water in guest shower. 11-12-24 1. Nothing has been fixed from above.
BLD - BUILDING FINAL 11/15/2024 Disapproved - NO FEE KSANDOE
Note: Updated energy calcs required 11/12/2024 - PREVIOUS INSPECTION NOTES 11/8/2024 - PREVIOUS INSPECTION NOTES 11/6/2024 - PREVIOUS INSPECTION NOTES 11-8-24 1. No energy cals. 2. Hole in attic from garage to house needs to be repaired. 3. No hot water in guest shower. 11-12-24 1. Nothing has been fixed from above.
BLD - BUILDING FINAL 11/12/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 11/8/2024 - PREVIOUS INSPECTION NOTES 11/6/2024 - PREVIOUS INSPECTION NOTES 11-8-24 1. No energy cals. 2. Hole in attic from garage to house needs to be repaired. 3. No hot water in guest shower. 11-12-24 1. Nothing has been fixed from above.
BLD - BUILDING FINAL 11/08/2024 Disapproved - NO FEE BTAYLOR
Note: 11/6/2024 - PREVIOUS INSPECTION NOTES 11-8-24 1. No energy cals. 2. Hole in attic from garage to house needs to be repaired. 3. No hot water in guest shower.
U -UTILITY RESIDENTIAL FINAL 11/07/2024 FINAL APPROVED LFITZGERALD
Note: 11/6/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 IRR with potable water. PVB in place. No CC
U -UTILITY RESIDENTIAL FINAL 11/06/2024 CANCELLED BY APPLICANT LFITZGERALD
Note: Inspector Notes from Inspection 9035 IRR with potable water. PVB in place. No CC
BLD - BUILDING FINAL 11/06/2024 CANCELLED BY APPLICANT BTAYLOR
ROW - FINAL APRON (AFTER POUR) 10/22/2024 APPROVED FSLADISH
Note: 10/22/24 BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/22/2024 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 10/22/2024 APPROVED FSLADISH
Note: 10/22/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 10/22/2024 APPROVED FSLADISH
Note: 10/22/24 BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U-CROSS CONNECTION 10/18/2024 APPROVED - AS NOTED BWRIGHT
Note: IRR with potable water. PVB in place. No CC
ELECTRIC - EARLY POWER 09/16/2024 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2200 4-12-24 1. Emailed FPL at 9:05. 9-16-24 1. Emailed FPL at 9:04.
ROW- PRE-APRON (PRE-POUR) 09/11/2024 APPROVED FSLADISH
Note: 9/11/24 You are ready to lay pavers at the time of this inspection.
ROW- PAVER RESTRAINTS 09/11/2024 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9270 8/27/24 READY TO POUR AT THE TIME OF THIS INSPECTION. , BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection.
ROW- PRE-APRON (PRE-POUR) 08/27/2024 APPROVED - AS NOTED FSLADISH
Note: 8/27/24 READY TO POUR AT THE TIME OF THIS INSPECTION. , BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection.
LATH/BRICK/ WATER BARRIER 06/18/2024 APPROVED BTAYLOR
Note: 6/13/2024 - PREVIOUS INSPECTION NOTES 6-13-24 1. Need to have stucco approved outlet boxes installed for outside electric. 2. Need wire lath over holes on rear porch and right side of house. 3. Silt fence needs to be repaired before next inspection.
LATH/BRICK/ WATER BARRIER 06/13/2024 Disapproved - NO FEE BTAYLOR
Note: 6-13-24 1. Need to have stucco approved outlet boxes installed for outside electric. 2. Need wire lath over holes on rear porch and right side of house. 3. Silt fence needs to be repaired before next inspection.
INSULATION 06/11/2024 APPROVED BTAYLOR
Note: 6/7/2024 - PREVIOUS INSPECTION NOTES 6/7/24: Incomplete Inspection. Please walk your site for complete code compliance. * Missing firestop at 2 locations in garage. Marked with FS on studs below. * Missing Firestop at all Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Too many areas to identify.
INSULATION 06/07/2024 Disapproved -FEE REQUIRED RSIMS
Note: 6/7/24: Incomplete Inspection. Please walk your site for complete code compliance. * Missing firestop at 2 locations in garage. Marked with FS on studs below. * Missing Firestop at all Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Too many areas to identify.
GRAVITY SEWER TEST 06/04/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 06/04/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ALL ROUGH 05/28/2024 APPROVED BTAYLOR
ROOF VALLEY & METAL 05/24/2024 APPROVED KSANDOE
Note: 5/17/2024 - PREVIOUS INSPECTION NOTES 5-17-24 1. Can not pass this inspection without roof sheeting, braces and tie downs not being approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/20/2024 APPROVED BTAYLOR
Note: 5/17/2024 - PREVIOUS INSPECTION NOTES 4/19/2024 - PREVIOUS INSPECTION NOTES 4/19/24: 1). Still missing address 2). Plans in box are incomplete and damaged.. New set needed. 3). Truss layout on plan (and found laying on the ground) does not match MiTek. 4). No silt fence along right sie of property. 4/18/2024 - PREVIOUS INSPECTION NOTES 4-18-24 1. Address needs to be posted. 2. No plans or mitek book in box. 5-17-24 1. Address needs to be posted. 2. No plans or mitek book in box.
ROOF VALLEY & METAL 05/17/2024 Disapproved - NO FEE BTAYLOR
Note: 5-17-24 1. Can not pass this inspection without roof sheeting, braces and tie downs not being approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/17/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 4/19/2024 - PREVIOUS INSPECTION NOTES 4/19/24: 1). Still missing address 2). Plans in box are incomplete and damaged.. New set needed. 3). Truss layout on plan (and found laying on the ground) does not match MiTek. 4). No silt fence along right sie of property. 4/18/2024 - PREVIOUS INSPECTION NOTES 4-18-24 1. Address needs to be posted. 2. No plans or mitek book in box. 5-17-24 1. Address needs to be posted. 2. No plans or mitek book in box.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/19/2024 Disapproved -FEE REQUIRED RSIMS
Note: 4/19/24: 1). Still missing address 2). Plans in box are incomplete and damaged.. New set needed. 3). Truss layout on plan (and found laying on the ground) does not match MiTek. 4). No silt fence along right sie of property. 4/18/2024 - PREVIOUS INSPECTION NOTES 4-18-24 1. Address needs to be posted. 2. No plans or mitek book in box.
WALL SHEATHING 04/18/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/18/2024 Disapproved - NO FEE BTAYLOR
Note: 4-18-24 1. Address needs to be posted. 2. No plans or mitek book in box.
ELECTRIC-TUG 04/12/2024 APPROVED - AS NOTED BTAYLOR
Note: 4-12-24 1. Emailed FPL at 9:05.
TIE BEAM / LINTEL 04/09/2024 APPROVED BTAYLOR
Note: 4/8/2024 - PREVIOUS INSPECTION NOTES 4-8-24 1. Dowel not drilled correctly. 2. Dowel is to close to block. 3. Dowel is outside block. All are circled on plans.
TIE BEAM / LINTEL 04/08/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 4-8-24 1. Dowel not drilled correctly. 2. Dowel is to close to block. 3. Dowel is outside block. All are circled on plans.
FOUND SURVEY APPROVED (OFFICE) 04/08/2024 APPROVED TBAKER
MONOLITHIC SLAB 03/20/2024 APPROVED BTAYLOR
Note: 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/2024 - PREVIOUS INSPECTION NOTES 03-18-2024 1. Soil has washed into the footing area. Back left and right areas. Check all. 2. Slab not proper thickness (2 1/2") as per plan and code. Check all areas. Please have multiple lines set for next inspection.
MONOLITHIC SLAB 03/18/2024 Disapproved - NO FEE AGAETANO
Note: 03-18-2024 GEOTECH REPORT NOT SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT Inspection stopped.
MONOLITHIC SLAB 03/18/2024 Disapproved - NO FEE AGAETANO
Note: 3/18/2024 - PREVIOUS INSPECTION NOTES 03-18-2024 1. Soil has washed into the footing area. Back left and right areas. Check all. 2. Slab not proper thickness (2 1/2") as per plan and code. Check all areas. Please have multiple lines set for next inspection.
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2024 APPROVED BTAYLOR
WATER METER INSTALLATION REQUEST 03/07/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 11/15/2024 11/18/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/15/2024 04/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/09/2024 04/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/07/2024 04/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/07/2024 04/08/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 02/22/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 02/22/2024 02/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 02/08/2024 02/09/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC HOLD 02/08/2024 02/09/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85
MECH HOLD 02/08/2024 02/13/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Chosen equipment exceeds the 80% design allowance for sensible load. Unit is too small. 2. Square footage on energy calcs does not match the house
SW1 COMPLETE 02/08/2024 02/15/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
URB COMPLETE 01/24/2024 01/25/2024
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BADMIN COMPLETE 01/23/2024 01/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2024 01/24/2024
Note: Released By: JPI
CUSVC COMPLETE 01/23/2024 01/26/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 01/23/2024 01/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 01/23/2024 01/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 01/23/2024 01/26/2024
LOCATE COMPLETE 01/23/2024 01/25/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 01/23/2024 01/26/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs from 2023 code cycle
SW1 HOLD 01/23/2024 01/30/2024
Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM According to the platted subdivision plan, the drainage of the property should be directed to the back. Could you please clarify if you are using the same document?
ZON HOLD 01/23/2024 01/24/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Missing the width of the walkway. Landscape provided is not the same home provide the correct site plan. Banding wrapping corners: Banding must wrap corners at least two feet. Please extend on both side of the home.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 11/15/2024
REINSPECTION RESIDENTIAL ¤40.00 11/15/2024
REINSPECTION RESIDENTIAL ¤40.00 11/15/2024
REINSPECTION RESIDENTIAL ¤40.00 11/15/2024
REINSPECTION RESIDENTIAL ¤40.00 11/15/2024
REINSPECTION RESIDENTIAL ¤40.00 11/15/2024
CONNECTION FEES ¤25.00 02/27/2024
WATER-METER ¤514.49 02/27/2024
ADJUSTMENT 50% (¤818.08) 02/27/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/27/2024
INSPECTION - RESIDENTIAL ¤1,251.25 02/27/2024
PLAN REVIEW - RESIDENTIAL ¤354.90 02/27/2024
FC IMPACT FEE EMS ¤62.00 02/27/2024
IMPACT FEE FIRE ¤428.09 02/27/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/27/2024
FC IMPACT FEE LIBRARY ¤268.00 02/27/2024
IMPACT FEE PARKS ¤1,800.99 02/27/2024
IMPACT FEE SCHOOL ¤5,450.00 02/27/2024
IMPACT FEE TRANSPORTATION ¤3,404.00 02/27/2024
SURCHARGE FS 533.721 ¤8.18 02/27/2024
SURCHARGE - FS 468.631 ¤12.27 02/27/2024
SW ENG - FOUNDATION SURVEY ¤20.00 02/27/2024
SW ENG INSPECTION 80 ¤80.00 02/27/2024
SW ENG PRE APRON ¤30.00 02/27/2024
SW ENG - REVIEW 20 ¤20.00 02/27/2024
SW ENG RES REVIEW 200 ¤200.00 02/27/2024
SEWER INSPECTION ¤25.00 02/27/2024
SEWER CAPITAL FACILITY ¤2,924.57 02/27/2024
WATER CAPITAL FACILITY FEE ¤2,731.83 02/27/2024
SITE PLAN 30 ¤30.00 02/27/2024
Fees Total Due: ¤0.00 Total Paid: ¤19,290.49