I want to search for...

Permit #2024010897

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00300-0020
CONDITIONED SPACE: 1801 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 18 sqft
OPENED PORCH (WITH ROOF) : 70 sqft
Total Square Footage: 2299 sqft
Block: 00300
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 202-494-2019
Location Address: 3 PICKERING DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/12/2024
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: INB BFR FUND 1 LLC

Address

3670 MAGUIRE BOULEVARD STE 220

ORLANDO , FL 32803

Lot: 0020
Contracted Stated Job Value: ¤175,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/06/2024 FINAL APPROVED RSIMS
Note: 11/1/2024 - PREVIOUS INSPECTION NOTES 11/1/24 1. Pep Tank not hooked up 2. 2 outlets in garage, left side and for GDO, have no power 3. Several interior doors needs adjustments to close properly
ROW - FINAL APRON (AFTER POUR) 11/06/2024 APPROVED - AS NOTED FSLADISH
Note: 11/6/24 INSPECTOR REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. PASSING AS NOTED. __________________________________________________________________________________________________________________________ 11/1/2024 - PREVIOUS INSPECTION NOTES 11/01/24 TPLACEK** ALL SEDIMENT AND OVER POUR NEEDS TO BE CLEANED OUT OF CULVERT
U -UTILITY RESIDENTIAL FINAL 11/06/2024 FINAL APPROVED LFITZGERALD
Note: 11/1/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY DHANEY 11/1/2024 8:16:44 AM *** No sewer pump/floats in Pep Tank . advised sewer dept. . Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:04:23 PM *** no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 11/01/2024 Disapproved - NO FEE TPOLACEK
Note: 11/01/24 TPLACEK** ALL SEDIMENT AND OVER POUR NEEDS TO BE CLEANED OUT OF CULVERT
ROW - STORMWATER FINAL 11/01/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 11/01/2024 Disapproved - NO FEE DHANEY
Note: *** NOTES ADDED BY DHANEY 11/1/2024 8:16:44 AM *** No sewer pump/floats in Pep Tank . advised sewer dept. . Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:04:23 PM *** no irrigation-no cross connection
BLD - BUILDING FINAL 11/01/2024 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 11/1/24 1. Pep Tank not hooked up 2. 2 outlets in garage, left side and for GDO, have no power 3. Several interior doors needs adjustments to close properly
ELECTRIC 1ST ROUGH UNDERGROUND 11/01/2024 CANCELLED BY INSPECTOR MCONTRYMAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/30/2024 APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9270 10/16/24 TPOLACEK *** PLEASE MAKE SURE YOU HAVE 6" ACROSS ROAD AREA BEFORE POURING. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. New inspection due to canceled inspection 10/1/2024 - PREVIOUS INSPECTION NOTES 10/01/24 TPOLACEK*** RECIEVED TEXT FROM FRANK RRQUESTING TO CANCEL PRE POUR 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 THE RAINS FROM HELENE HAVE BEGUN. YOUR POUR AREA IS TO WET AND SOFT WITH WASHOUTS. PHOTO FOR REFERENCE.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/30/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 10/28/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:04:23 PM *** no irrigation-no cross connection
ROW- PRE-APRON (PRE-POUR) 10/16/2024 APPROVED - AS NOTED TPOLACEK
Note: 10/16/24 TPOLACEK *** PLEASE MAKE SURE YOU HAVE 6" ACROSS ROAD AREA BEFORE POURING. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. New inspection due to canceled inspection 10/1/2024 - PREVIOUS INSPECTION NOTES 10/01/24 TPOLACEK*** RECIEVED TEXT FROM FRANK RRQUESTING TO CANCEL PRE POUR 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 THE RAINS FROM HELENE HAVE BEGUN. YOUR POUR AREA IS TO WET AND SOFT WITH WASHOUTS. PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 10/07/2024 CANCELLED BY APPLICANT WEB
Note: 10/1/2024 - PREVIOUS INSPECTION NOTES 10/01/24 TPOLACEK*** RECIEVED TEXT FROM FRANK RRQUESTING TO CANCEL PRE POUR 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 THE RAINS FROM HELENE HAVE BEGUN. YOUR POUR AREA IS TO WET AND SOFT WITH WASHOUTS. PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 10/01/2024 CANCELLED BY APPLICANT TPOLACEK
Note: 10/01/24 TPOLACEK*** RECIEVED TEXT FROM FRANK RRQUESTING TO CANCEL PRE POUR 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 THE RAINS FROM HELENE HAVE BEGUN. YOUR POUR AREA IS TO WET AND SOFT WITH WASHOUTS. PHOTO FOR REFERENCE.
ELECTRIC - EARLY POWER 09/30/2024 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/30/2024 2:01:21 PM *** Inspector Notes from Inspection 2200 8/1/24: FPL emailed at @ 12:00 > approved for TUG 9/30/24: FPL emailed to release power. Inspector Notes from Inspection 2200 8/1/24: FPL emailed at @ 12:00 > approved for TUG Inspector Notes from Inspection 2200 8/1/24: FPL emailed at @ 12:00 > approved for TUG
ROW- PRE-APRON (PRE-POUR) 09/26/2024 Disapproved -FEE REQUIRED FSLADISH
Note: 9/26/24 THE RAINS FROM HELENE HAVE BEGUN. YOUR POUR AREA IS TO WET AND SOFT WITH WASHOUTS. PHOTO FOR REFERENCE.
GRAVITY SEWER TEST 09/06/2024 APPROVED MGIBSON
SEWER TIE IN 09/06/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 08/28/2024 APPROVED CBOWERMASTER
Note: 8/26/2024 7:15:45 AM- PREVIOUS INSPECTION NOTES dumpster in the way
INSULATION 08/28/2024 APPROVED LMILLER
Note: *** NOTES ADDED BY LMILLER 8/28/2024 4:34:44 PM *** prior notes resolved 8/27/2024 - PREVIOUS INSPECTION NOTES 8/27/24: Previous deficiency remains unresolved. 1). Missing fireblocking & firestop in garage on back and right side walls where ceiling level change occurs. FBC-R302.11 2). Insulating foam at top plate of dryer exhaust needs to be removed and replaced with fire rated foam. R302.11.1 Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/20/2024 3:52:46 PM *** Please pad the margins at the garage to house door to 1/4" shim space and install shims at each anchor. FBCR R609.1
INSULATION 08/27/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/27/2024 11:58:06 AM *** 8/27/24: Previous deficiency remains unresolved. 1). Missing fireblocking & firestop in garage on back and right side walls where ceiling level change occurs. FBC-R302.11 2). Insulating foam at top plate of dryer exhaust needs to be removed and replaced with fire rated foam. R302.11.1 Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/20/2024 3:52:46 PM *** Please pad the margins at the garage to house door to 1/4" shim space and install shims at each anchor. FBCR R609.1
PEP TANK INSTALLATION REQUEST 08/23/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster in the way
ALL ROUGH 08/20/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/20/2024 3:52:46 PM *** Please pad the margins at the garage to house door to 1/4" shim space and install shims at each anchor. FBCR R609.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/19/2024 APPROVED MKRASKI
Note: 7/26/2024 - PREVIOUS INSPECTION NOTES 7/26/24: Walked with Superintendent. Revision still required for missing Truss T107A where 2nd Truss T107 is installed. Also, 2nd Truss T107 (Towards front of house) needs the correct truss engineering installed. (Currently 2pcs of 3/4PT - Must be the same species, dimensions & length of web). 7/25/2024 - PREVIOUS INSPECTION NOTES 7/25/24: No Change from Previous Inspection. * Also, please print out Engineer's repair letter for damaged Truss T20 and include with Plan documents. 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24: 1). A revision will need to be submitted to & approved by the City for the truss layout that does not match the installed trusses. 2). Truss T02 web engineerring/bracing is installed on the wrong web. Marked on MiTek. 3). Truss T07 is missing web engineering/bracing as required on MiTek. 4). Truss T07A is missing. (a second Truss T07 is installed which does not match the configuration shown on MiTek).
LATH/BRICK/ WATER BARRIER 08/05/2024 APPROVED RSIMS
ELECTRIC-TUG 08/01/2024 APPROVED - AS NOTED RSIMS
Note: 8/1/24: FPL emailed at @ 12:00 > approved for TUG
ROOF VALLEY & METAL 07/29/2024 APPROVED LMILLER
Note: 7/23/2024 - PREVIOUS INSPECTION NOTES 7/23/24: 1). Drip edge/eave drip is incomplete at front of garage. 2). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/26/2024 Disapproved - NO FEE RSIMS
Note: 7/26/24: Walked with Superintendent. Revision still required for missing Truss T107A where 2nd Truss T107 is installed. Also, 2nd Truss T107 (Towards front of house) needs the correct truss engineering installed. (Currently 2pcs of 3/4PT - Must be the same species, dimensions & length of web). 7/25/2024 - PREVIOUS INSPECTION NOTES 7/25/24: No Change from Previous Inspection. * Also, please print out Engineer's repair letter for damaged Truss T20 and include with Plan documents. 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24: 1). A revision will need to be submitted to & approved by the City for the truss layout that does not match the installed trusses. 2). Truss T02 web engineerring/bracing is installed on the wrong web. Marked on MiTek. 3). Truss T07 is missing web engineering/bracing as required on MiTek. 4). Truss T07A is missing. (a second Truss T07 is installed which does not match the configuration shown on MiTek).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/25/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/25/24: No Change from Previous Inspection. * Also, please print out Engineer's repair lettewr for damaged Truss T20 and include with Plan documents. 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24: 1). A revision will need to be submitted to & approved by the City for the truss layout that does not match the installed trusses. 2). Truss T02 web engineerring/bracing is installed on the wrong web. Marked on MiTek. 3). Truss T07 is missing web engineering/bracing as required on MiTek. 4). Truss T07A is missing. (a second Truss T07 is installed which does not match the configuration shown on MiTek).
ROOF VALLEY & METAL 07/23/2024 Disapproved - NO FEE RSIMS
Note: 7/23/24: 1). Drip edge/eave drip is incomplete at front of garage. 2). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
WALL SHEATHING 07/22/2024 APPROVED RSIMS
Note: 7/15/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2340 Repair and maintain silt fence 07-15-2024 Right side of wall sheathing not fastened completely.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/22/2024 Disapproved - NO FEE RSIMS
Note: 7/22/24: 1). A revision will need to be submitted to & approved by the City for the truss layout that does not match the installed trusses. 2). Truss T02 web engineerring/bracing is installed on the wrong web. Marked on MiTek. 3). Truss T07 is missing web engineering/bracing as required on MiTek. 4). Truss T07A is missing. (a second Truss T07 is installed which does not match the configuration shown on MiTek).
WALL SHEATHING 07/15/2024 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2340 Repair and maintain silt fence 07-15-2024 Right side of wall sheathing not fastened completely.
ROOF SHEATHING 07/15/2024 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2340 Repair and maintain silt fence
TIE BEAM / LINTEL 07/02/2024 APPROVED - AS NOTED KSANDOE
Note: Repair and maintain silt fence
FOUND SURVEY APPROVED (OFFICE) 06/26/2024 APPROVED AMOBLEY
MONOLITHIC SLAB 06/20/2024 APPROVED KSANDOE
Note: 6/18/2024 - PREVIOUS INSPECTION NOTES Vapor barrier must be properly secured in place.
MONOLITHIC SLAB 06/18/2024 Disapproved -FEE REQUIRED KSANDOE
Note: Vapor barrier must be properly secured in place.
ELECTRIC 1ST ROUGH UNDERGROUND 06/12/2024 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 06/12/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/11/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/06/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 10/22/2024 10/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/12/2024 08/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/12/2024 08/13/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 07/16/2024 07/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/26/2024 06/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete
ZON COMPLETE 06/26/2024 06/26/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 HOLD 06/12/2024 06/12/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete
ZON COMPLETE 06/12/2024 06/12/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2024 06/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter must be accompanied by a signed and sealed inspection and certification letter by the geotechnical engineer of record. Engineer’s letter to confirm the following: Site clearing / over excavation was completed and inspected by engineer prior to the placement of fill and engineer confirms clearing and over excavation work is acceptable. Engineer to confirm fill materials were suitable and within specifications. Engineer to confirm the required number and location of field density tests were completed. Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4)
BLD HOLD 05/29/2024 06/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter must be accompanied by a signed and sealed inspection and certification letter by the geotechnical engineer of record. Engineer’s letter to confirm the following: Site clearing / over excavation was completed and inspected by engineer prior to the placement of fill and engineer confirms clearing and over excavation work is acceptable. Engineer to confirm fill materials were suitable and within specifications. Engineer to confirm the required number and location of field density tests were completed. Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4)
ELEC COMPLETE 04/02/2024 04/05/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
BLD COMPLETE 04/02/2024 04/05/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
ELEC COMPLETE 04/02/2024 04/05/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
ELEC HOLD 03/26/2024 04/01/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen need to be GFCI protected. NEC 2020 210.8
ENGIN1 COMPLETE 03/26/2024 03/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/26/2024 03/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/26/2024 03/26/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 03/26/2024 04/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/14/2024 03/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 03/14/2024 03/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen need to be GFCI protected. NEC 2020 210.8
MECH COMPLETE 03/14/2024 03/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 03/14/2024 03/15/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN COMPLETE 03/01/2024 03/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/01/2024 03/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2024 02/23/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 02/23/2024 02/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/23/2024 02/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH COMPLETE 02/23/2024 02/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN HOLD 02/23/2024 02/29/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Completion and Submittal of a Geotech Report and Identification of Subsurface Conditions Geotech reports are intended to identify subsurface conditions typically including classification of soils, soil compressibility or expansiveness, the elevation of the ground water table, evaluation of soil strength and adequacy of the soils and other whether other unsuitable subsurface conditions exist that must be mitigated in order for the soil to support the structure. The geotech engineer will determine the methods used to complete this process. 2. Foundation Engineer to provide presumptive load bearing value used for foundation design per R401.4.1 3. Geotechnical Report Not Accepted. Report submitted indicates root fibers and silt should be cleared to 24 inches. Provide amended geotechnical report to include the information below.
BLD COMPLETE 02/23/2024 02/26/2024
Note: Released By: JPI
ENGIN1 HOLD 01/29/2024 01/29/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Benchmark elevation is off by 1' +/-
BADMIN HOLD 01/24/2024 01/30/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. If report determines unsuitable sub-surface conditions or unsuitable soil conditions, then engineer shall provide a soils mitigation plan in order to ensure soils are suitable to receive the building's foundation. Report to include fill and compaction specifications and engineering inspection requirements. At conclusion of any soils mitigation work, engineer will be required to certify work was performed according to plans. Be advised, if the geotechnical report reveals any unsuitable soils and / or subsurface conditions, the first inspection for this permit (1st Rough / Underground Plumbing) will be HELD until such time as a report by the geotechnical engineer is submitted to the Building Division documenting that the soil mitigation work has been completed according to the engineer's plans and is now suitable for construction. Report must also include a record of all required compaction testing.
BLD COMPLETE 01/24/2024 01/29/2024
Note: Released By: JPI
CUSVC COMPLETE 01/24/2024 01/26/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 01/24/2024 01/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 01/24/2024 01/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS COMPLETE 01/24/2024 01/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 01/24/2024 01/25/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 01/24/2024 01/29/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs from 2023 code cycle
SW1 COMPLETE 01/24/2024 01/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 01/24/2024 01/24/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation: Right side window is missing banding
SWALE COMPLETE 01/24/2024 03/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 11/06/2024
REINSPECTION RESIDENTIAL ¤40.00 11/06/2024
REINSPECTION RESIDENTIAL ¤40.00 11/06/2024
REINSPECTION RESIDENTIAL ¤40.00 11/06/2024
REINSPECTION RESIDENTIAL ¤40.00 11/06/2024
UTILITY PEP REINSPECTION ¤40.00 11/06/2024
SW ENG REINSPECTION 30 ¤30.00 11/06/2024
SW ENG - REVIEW 20 ¤20.00 03/12/2024
SW ENG RES REVIEW 200 ¤200.00 03/12/2024
SEWER CREDIT (¤319.00) 03/12/2024
SEWER INSPECTION ¤25.00 03/12/2024
SEWER CAPITAL FACILITY ¤5,441.03 03/12/2024
WATER CREDIT (¤166.67) 03/12/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 03/12/2024
SITE PLAN 30 ¤30.00 03/12/2024
WATER- TURN ON ¤25.00 03/12/2024
ADJUSTMENT 50% (¤599.22) 03/12/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/12/2024
INSPECTION - RESIDENTIAL ¤910.25 03/12/2024
PLAN REVIEW - RESIDENTIAL ¤258.18 03/12/2024
CONNECTION FEES ¤1,187.26 03/12/2024
FC IMPACT FEE EMS ¤62.00 03/12/2024
IMPACT FEE FIRE ¤428.09 03/12/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/12/2024
FC IMPACT FEE LIBRARY ¤268.00 03/12/2024
IMPACT FEE PARKS ¤1,800.99 03/12/2024
IMPACT FEE SCHOOL ¤5,450.00 03/12/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 03/12/2024
WATER -IRRIGATION INSPECTION ¤25.00 03/12/2024
SURCHARGE FS 533.721 ¤5.99 03/12/2024
SURCHARGE - FS 468.631 ¤8.99 03/12/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/12/2024
SW ENG INSPECTION 80 ¤80.00 03/12/2024
SW ENG PRE APRON ¤30.00 03/12/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,557.90