Permit #2024010965

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00460-0300
CONDITIONED SPACE: 1500 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2008 sqft
Block: 00460
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 202-494-2019
Location Address: 105 WHIPPOORWILL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/14/2024
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: INB BFR FUND 1 LLC

Address

3670 MAGUIRE BOULEVARD SUITE 220

ORLANDO, FL 32803

Lot: 0300
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/11/2024 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 09/10/2024 CANCELLED BY APPLICANT MKRASKI
Note: 9/10/24 Canceled via text from Frankie 9/9/2024 - PREVIOUS INSPECTION NOTES 1. GFCI protection required for dryer and range NEC 210.8 2. Surge protection required for electrical service NEC 230.67 3. Stucco damaged under meter main FBC R402.4.1.1
BLD - BUILDING FINAL 09/09/2024 Disapproved - NO FEE MKRASKI
Note: 1. GFCI protection required for dryer and range NEC 210.8 2. Surge protection required for electrical service NEC 230.67 3. Stucco damaged under meter main FBC R402.4.1.1
U -UTILITY RESIDENTIAL FINAL 09/09/2024 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 8/13/2024 9:44:02 AM *** no irr-no cross connection
ROW - STORMWATER FINAL 09/06/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/06/2024 APPROVED TPOLACEK
Note: 09/06/24 TPOLACEK*** 8/27/2024 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE ELEVATIONS RIGHT OF THE CULVERT SHOWS IT LOWER THAN THE LEFT SIDE ROADSIDE SWALE ELEVATIONS SO YOUR THE WATER IS GOING TO SIT IN THE SWALE. NEED TO GRADE THE SWALE SO IT WILL FLOW CORRECT. PLEASE SEE PHOTO ATTACHED TO THIS INSPECTION 9463 FOR CORRECT GRADING. ------------------------------------------------------------------ 8/14/2024 - PREVIOUS INSPECTION NOTES 08/14/24 TPOLACEK*** PLEASE READ ALL NOTES., FINAL SURVEY INDICATES BACK YARD WILL NEG IMPACT THE REAR ADJACENT PROPERTY. 30.00 - 30.00 - 29.00. LEFT SIDE PROPERTY LINE ALSO DOES NOT HAVE ENOUGH POSITIVE FLOW. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Inspector Notes from Inspection 9270 07/24/24 TPOLACEK** FRONT FORM BOARD ALONG ROADSIDE EDGE NEEDS TO BE MOVED OUT TOWARDS THE EXISTING ROAD EDGE. I WILL APPROVE AS NOTED BUT CORRECTIONS MUST BE MADE BEFORE POURING DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING Inspector Notes from Inspection 9470 06/20/24 TPOLACEK*** CORRECTIONS MADE BUILDER MUST KEEP SWALE OPEN DURING ENTIRE BUILD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/18/2024 - PREVIOUS INSPECTION NOTES 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
ROW FIELD SURVEY /GRADING CERTIFICATION 09/06/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 09/06/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/27/2024 Disapproved - NO FEE PFLANAGAN
Note: THE ROADSIDE SWALE ELEVATIONS RIGHT OF THE CULVERT SHOWS IT LOWER THAN THE LEFT SIDE ROADSIDE SWALE ELEVATIONS SO YOUR THE WATER IS GOING TO SIT IN THE SWALE. NEED TO GRADE THE SWALE SO IT WILL FLOW CORRECT. PLEASE SEE PHOTO ATTACHED TO THIS INSPECTION 9463 FOR CORRECT GRADING. ------------------------------------------------------------------ 8/14/2024 - PREVIOUS INSPECTION NOTES 08/14/24 TPOLACEK*** PLEASE READ ALL NOTES., FINAL SURVEY INDICATES BACK YARD WILL NEG IMPACT THE REAR ADJACENT PROPERTY. 30.00 - 30.00 - 29.00. LEFT SIDE PROPERTY LINE ALSO DOES NOT HAVE ENOUGH POSITIVE FLOW. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Inspector Notes from Inspection 9270 07/24/24 TPOLACEK** FRONT FORM BOARD ALONG ROADSIDE EDGE NEEDS TO BE MOVED OUT TOWARDS THE EXISTING ROAD EDGE. I WILL APPROVE AS NOTED BUT CORRECTIONS MUST BE MADE BEFORE POURING DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING Inspector Notes from Inspection 9470 06/20/24 TPOLACEK*** CORRECTIONS MADE BUILDER MUST KEEP SWALE OPEN DURING ENTIRE BUILD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/18/2024 - PREVIOUS INSPECTION NOTES 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
WINDOW NAILING 08/15/2024 APPROVED MKRASKI
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/14/2024 Disapproved - NO FEE TPOLACEK
Note: 08/14/24 TPOLACEK*** PLEASE READ ALL NOTES., FINAL SURVEY INDICATES BACK YARD WILL NEG IMPACT THE REAR ADJACENT PROPERTY. 30.00 - 30.00 - 29.00. LEFT SIDE PROPERTY LINE ALSO DOES NOT HAVE ENOUGH POSITIVE FLOW. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Inspector Notes from Inspection 9270 07/24/24 TPOLACEK** FRONT FORM BOARD ALONG ROADSIDE EDGE NEEDS TO BE MOVED OUT TOWARDS THE EXISTING ROAD EDGE. I WILL APPROVE AS NOTED BUT CORRECTIONS MUST BE MADE BEFORE POURING DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING Inspector Notes from Inspection 9470 06/20/24 TPOLACEK*** CORRECTIONS MADE BUILDER MUST KEEP SWALE OPEN DURING ENTIRE BUILD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/18/2024 - PREVIOUS INSPECTION NOTES 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
U-CROSS CONNECTION 08/13/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 8/13/2024 9:44:02 AM *** no irr-no cross connection
WINDOW NAILING 08/13/2024 Disapproved - NO FEE MKRASKI
Note: 1. Trim must be removed for inspection to see that it is sealed 2. fasteners have been covered must remove to ensure fasteners have been installed properly
ELECTRIC - EARLY POWER 07/24/2024 APPROVED - AS NOTED MKRASKI
Note: Electrical plans call for 2 5/8'' ground rods 6' apart AND tied to building steel, make correction or have revision approved by Building Dept. Check @ final
ROW- PRE-APRON (PRE-POUR) 07/24/2024 APPROVED - AS NOTED TPOLACEK
Note: 07/24/24 TPOLACEK** FRONT FORM BOARD ALONG ROADSIDE EDGE NEEDS TO BE MOVED OUT TOWARDS THE EXISTING ROAD EDGE. I WILL APPROVE AS NOTED BUT CORRECTIONS MUST BE MADE BEFORE POURING DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING Inspector Notes from Inspection 9470 06/20/24 TPOLACEK*** CORRECTIONS MADE BUILDER MUST KEEP SWALE OPEN DURING ENTIRE BUILD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/18/2024 - PREVIOUS INSPECTION NOTES 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
GRAVITY SEWER TEST 07/22/2024 APPROVED MGIBSON
SEWER TIE IN 07/22/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 06/26/2024 APPROVED CBOWERMASTER
Note: 6/21/2024 7:16:00 AM- PREVIOUS INSPECTION NOTES dumpster
ROW - DRAINAGE 06/20/2024 APPROVED - AS NOTED TPOLACEK
Note: 06/20/24 TPOLACEK*** CORRECTIONS MADE BUILDER MUST KEEP SWALE OPEN DURING ENTIRE BUILD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/18/2024 - PREVIOUS INSPECTION NOTES 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
ROW - DRAINAGE 06/18/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 06/18/24 TPOLACEK NEED TO REMOVE PORTA POTTY FROM SWALE. INSTALL PROPER TEMP PIPE AND MAKE SURE THAT SWALE WILL NOT IMPACT SURROUNDING PROPERTIES DURING RAIN. WILL REINSPECT ON THURSDAY 06/20/24 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/11/2024 - PREVIOUS INSPECTION NOTES DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
INSULATION 06/18/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Move porta-jon and debris out of swale before next insoection Window nailing inspection added for garage entry door
INSULATION 06/17/2024 Disapproved - NO FEE MKRASKI
Note: 6/17/24 1. Garage entry door missing install door or seal opening Inspector Notes from Inspection 2420 1. Garage entry door missing, check on insulation if not installed a window/door nailing inspection will be added
PEP TANK INSTALLATION REQUEST 06/17/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster
ALL ROUGH 06/12/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Garage entry door missing, check on insulation if not installed a window/door nailing inspection will be added
ALL ROUGH 06/11/2024 Disapproved - NO FEE MKRASKI
Note: 1. Repair silt fence to its orginal condition 2. No E-cals on site to check duct layout 3. Garage entry door missing 4. Kitchen island chase needs to be sealed at slab
ROW - DRAINAGE 06/11/2024 Disapproved - NO FEE GBERTOLA
Note: DRAINAGE ACROSS THE FRONT SWALE IS BLOCKED; CORRECTION IS NEEDED DURING INSPECTION. CULVERT PIPE IS BENT. INSPECTOR BE BACK 6/18/24=
LATH/BRICK/ WATER BARRIER 06/10/2024 APPROVED MKRASKI
ELECTRIC-TUG 06/04/2024 APPROVED - AS NOTED MKRASKI
Note: Electrical plans call for 2 5/8'' ground rods 6' apart AND tied to building steel Check @ early power, Emailed FPL @ 2pm
ROOF VALLEY & METAL 06/04/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/04/2024 APPROVED FWILLIS
Note: 6/3/2024 - PREVIOUS INSPECTION NOTES 6/3/24: Cancelled by Applicant via text at @ 11:57. 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24 No repairs made 5/30/2024 - PREVIOUS INSPECTION NOTES 1. Must have full set of stamped plans on site for inspection, Set on site missing detail page(s) 2. Garage door bucks not per detail Not able to complete inspection with out plans, truss straps and roof decking ok, Unless plans call for differnt straps in differnt areas but again unable to know with out plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/03/2024 CANCELLED BY APPLICANT RSIMS
Note: 6/3/24: Cancelled by Applicant via text at @ 11:57. 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24 No repairs made 5/30/2024 - PREVIOUS INSPECTION NOTES 1. Must have full set of stamped plans on site for inspection, Set on site missing detail page(s) 2. Garage door bucks not per detail Not able to complete inspection with out plans, truss straps and roof decking ok, Unless plans call for differnt straps in differnt areas but again unable to know with out plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/31/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 5/31/24 No repairs made 5/30/2024 - PREVIOUS INSPECTION NOTES 1. Must have full set of stamped plans on site for inspection, Set on site missing detail page(s) 2. Garage door bucks not per detail Not able to complete inspection with out plans, truss straps and roof decking ok, Unless plans call for differnt straps in differnt areas but again unable to know with out plans
WALL SHEATHING 05/30/2024 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/30/2024 Disapproved - NO FEE MKRASKI
Note: 1. Must have full set of stamped plans on site for inspection, Set on site missing detail page(s) 2. Garage door bucks not per detail Not able to complete inspection with out plans, truss straps and roof decking ok, Unless plans call for differnt straps in differnt areas but again unable to know with out plans
ROOF SHEATHING 05/29/2024 APPROVED MKRASKI
Note:
ROOF SHEATHING 05/28/2024 Disapproved - NO FEE FWILLIS
Note: 5/28/24 - TRUSS T09, AT THE REAR BACK PATIO, SHINERS. PLEASE REMOVE. Inspector Notes from Inspection 2340 Inspector Notes from Inspection 2250 5/6/24 Have clean set of plans for next inspection per FBC 107.3.1 5/3/2024 - PREVIOUS INSPECTION NOTES 1. No intent to treat in box 2. Silt fence need to be in orginal order 3. Slab height is required per plans to be a min of 4'' 4. No ufer ground Stopped inspection not ready, Full re-inspection needed 05-17-2024 Have clean set of plans for next inspection per FBC 107.3.1
TIE BEAM / LINTEL 05/17/2024 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2250 5/6/24 Have clean set of plans for next inspection per FBC 107.3.1 5/3/2024 - PREVIOUS INSPECTION NOTES 1. No intent to treat in box 2. Silt fence need to be in orginal order 3. Slab height is required per plans to be a min of 4'' 4. No ufer ground Stopped inspection not ready, Full re-inspection needed 05-17-2024 Have clean set of plans for next inspection per FBC 107.3.1
FOUND SURVEY APPROVED (OFFICE) 05/15/2024 APPROVED TBAKER
MONOLITHIC SLAB 05/06/2024 APPROVED - AS NOTED MKRASKI
Note: 5/6/24 Have clean set of plans for next inspection per FBC 107.3.1 5/3/2024 - PREVIOUS INSPECTION NOTES 1. No intent to treat in box 2. Silt fence need to be in orginal order 3. Slab height is required per plans to be a min of 4'' 4. No ufer ground Stopped inspection not ready, Full re-inspection needed
MONOLITHIC SLAB 05/03/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. No intent to treat in box 2. Silt fence need to be in orginal order 3. Slab height is required per plans to be a min of 4'' 4. No ufer ground Stopped inspection not ready, Full re-inspection needed
PLUMBING 1ST ROUGH UNDERGROUND 04/30/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/29/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 04/09/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 07/29/2024 07/31/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/14/2024 05/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/14/2024 05/14/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 HOLD 05/01/2024 05/01/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete slab.
ZON COMPLETE 05/01/2024 05/01/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 04/24/2024 04/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 04/19/2024 04/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/14/2024 03/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 03/08/2024 03/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/08/2024 03/13/2024
Note: Released By: JPI
ELEC HOLD 03/01/2024 03/04/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen need to be GFCI protected. NEC 2020 210.8
ELEC HOLD 02/23/2024 02/29/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8
MECH COMPLETE 02/23/2024 02/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 02/23/2024 02/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/23/2024 02/26/2024
Note: Released By: JPI
SWALE COMPLETE 01/25/2024 03/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 01/24/2024 01/30/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Geotechnical report to include soil load bearing values. In lieu of this, the Foundation Engineer can provide presumptive load bearing value used for foundation design per R401.4.1 Geotechnical Report Not Accepted. Report submitted indicates root fibers and silt should be cleared to 24 inches. Provide amended geotechnical report to include the information below. • Specifications for the preparation of the site prior to placement of compacted fill material. • Specifications for material to be used as compacted fill. • Test methods to be used to determine the maximum dry density and optimum moisture content of the material used as compacted fill. • The maximum allowable thickness of each lift of compacted fill material. • Field test method for determining the in-place dry density of the compacted fill. • Minimum acceptable in-place dry density expressed as a percentage of the maximum dry density determine in accordance with the third bullet above. • Number and frequency of field tests required to determine compliance with the sixth bullet above. After the geotechnical report is approved by the City of Palm Coast, then the engineer must provide a signed and sealed letter certifying the entire process was completed in accordance with the engineer’s specifications. The engineer’s letter must include a certification statement in accordance with the Florida Administrative Code 61G15-18.011 (4).
BLD COMPLETE 01/24/2024 01/25/2024
Note: Released By: JPI
CUSVC COMPLETE 01/24/2024 01/29/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 01/24/2024 01/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 01/24/2024 01/25/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 01/24/2024 01/29/2024
LOCATE COMPLETE 01/24/2024 01/25/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 01/24/2024 01/29/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs from 2023 code cycle
SW1 COMPLETE 01/24/2024 01/25/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/24/2024 01/25/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/09/2024
REINSPECTION RESIDENTIAL ¤40.00 09/09/2024
REINSPECTION RESIDENTIAL ¤40.00 09/09/2024
SW ENG - INSPECTION 20 ¤20.00 09/09/2024
SW ENG - INSPECTION 20 ¤20.00 09/09/2024
SW ENG - INSPECTION 20 ¤20.00 09/09/2024
UTILITY PEP REINSPECTION ¤40.00 09/09/2024
SEWER CREDIT (¤3,512.73) 03/14/2024
SEWER INSPECTION ¤25.00 03/14/2024
SEWER CAPITAL FACILITY ¤5,441.03 03/14/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 03/14/2024
SITE PLAN 30 ¤30.00 03/14/2024
SW ENG INSPECTION 80 ¤80.00 03/14/2024
SW ENG PRE APRON ¤30.00 03/14/2024
SW ENG - REVIEW 20 ¤20.00 03/14/2024
SW ENG RES REVIEW 200 ¤200.00 03/14/2024
WATER- TURN ON ¤25.00 03/14/2024
ADJUSTMENT 50% (¤512.73) 03/14/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/14/2024
INSPECTION - RESIDENTIAL ¤775.50 03/14/2024
PLAN REVIEW - RESIDENTIAL ¤219.96 03/14/2024
CONNECTION FEES ¤1,187.26 03/14/2024
FC IMPACT FEE EMS ¤62.00 03/14/2024
IMPACT FEE FIRE ¤428.09 03/14/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/14/2024
FC IMPACT FEE LIBRARY ¤268.00 03/14/2024
IMPACT FEE PARKS ¤1,800.99 03/14/2024
IMPACT FEE SCHOOL ¤5,450.00 03/14/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 03/14/2024
WATER -IRRIGATION INSPECTION ¤25.00 03/14/2024
SURCHARGE FS 533.721 ¤5.13 03/14/2024
SURCHARGE - FS 468.631 ¤7.69 03/14/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/14/2024
Fees Total Due: ¤0.00 Total Paid: ¤18,392.20