Permit #2024010967

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7009-00210-0500
PATIO/DECK (NO ROOF) : 1365 sqft
Total Square Footage: 1365 sqft
Block: 00210
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: 386-225-1722
Location Address: 45 FAIRCASTLE LN
Type: PO - POOL
Issue Date: 02/15/2024
NOC: RECORDED
Applicant name: MICHAEL MARINO HANSEN
Owner: JMR III

Address

PO BOX 1347

FLAGLER BEACH, FL 32136

Lot: 0500
Contracted Stated Job Value: ¤86,500.00
Job Description: POOL AND ENCLOSURE
Type: CN

Contractor

PALM COAST POOLS, LLC
Status Location Address State License Number Phone
ACTIVE

29 COLUMBUS CT

PALM COAST, FL 32137

RP252555609 (Exp: 08/31/2027) 386-225-1722

Sub Contractors

BENJAMIN D DEWITT
Status Location Address State License Number Phone
ACTIVE

356 UNDERWOOD TRAIL

PALM COAST, FL 32164

ER13016065 (Exp: 08/31/2026) 321-262-4104
JOSEPH DEREK CARTWRIGHT
Status Location Address State License Number Phone Fax
ACTIVE

151 RODEO ROAD

ORMOND BEACH, FL 32174

SCC131150000 (Exp: 08/31/2026) 386-310-7962 (386)615-3713

Inspection History

Type Request Date Result Inspector
POOL FINAL 11/19/2024 FINAL APPROVED HCAMACHO
U -UTILITY RESIDENTIAL FINAL 11/08/2024 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/07/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE ------------------------------------------------------------- 9/25/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY NEEDS TO HAVE ELEVATIONS EVERY 20' AND CAPTURE ALL DRIANAGE PATTERNS. 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. 4) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns. 5) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 6) FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.
ROW FIELD SURVEY /GRADING CERTIFICATION 11/07/2024 APPROVED PFLANAGAN
Note: FIELD MATCHES THE FINAL SURVEY
ROW - FINAL INSPECTION 11/07/2024 APPROVED PFLANAGAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/25/2024 Disapproved - NO FEE PFLANAGAN
Note: THE FINAL SURVEY NEEDS TO HAVE ELEVATIONS EVERY 20' AND CAPTURE ALL DRIANAGE PATTERNS. 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. 4) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns. 5) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 6) FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.
ELECTRIC AND ALARM 07/19/2024 APPROVED - AS NOTED JWALKER
Note: 1. The control sub panel has not been bonded. See pool plan page 3 of 4. 2. The bonding screw on the pool pump needs to tightened down.
POOL DECK 06/06/2024 APPROVED JWALKER
STEEL AND GROUND 05/21/2024 APPROVED FWILLIS
ELECTRIC TEMP POLE 05/09/2024 Disapproved - NO FEE RMARTIN
Note: *** NOTES ADDED BY RMARTIN 5/9/2024 10:06:07 AM *** GROUND NOT CONNECTED TO GROUND ROD, OUTLET NEEDS TO BE SECURED

Review History

Department Status Date In Date Out
BLD COMPLETE 01/30/2024 01/30/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 01/30/2024 01/30/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 01/24/2024 01/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Screen engineering code years need to be updated
ELEC COMPLETE 01/24/2024 01/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/24/2024 01/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/24/2024 01/25/2024
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 01/24/2024 01/25/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤129.32) 02/15/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/15/2024
INSPECTION- POOL ¤160.00 02/15/2024
PLAN REVIEW - RESIDENTIAL ¤68.64 02/15/2024
SURCHARGE FS 533.721 ¤2.00 02/15/2024
SURCHARGE - FS 468.631 ¤2.00 02/15/2024
SW ENG INSPECTION 40 ¤40.00 02/15/2024
SW ENG - REVIEW 20 ¤20.00 02/15/2024
SITE PLAN 30 ¤30.00 02/15/2024
Fees Total Due: ¤0.00 Total Paid: ¤223.32