Permit #2024011145
Permit Details
Status: COED
| Parcel Id: 42-10-30-3210-00000-0230 |
| CONDITIONED SPACE: 2914 sqft |
| GARAGE: 716 sqft |
| OPENED PORCH (WITH ROOF) : 29 sqft |
| OPENED PORCH (WITH ROOF) : 387 sqft |
| Total Square Footage: 4046 sqft |
| Block: 00000 |
| Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH |
| Job Phone: 386-236-4133 |
| Location Address: 235 CONSERVATORY DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/29/2024 |
| NOC: RECORDED |
| Applicant name: LEONARDO CIRO SANCLEMENTE |
| Owner: FF FLORIDA LAND HOLDINGS LLC |
|
Address 2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤332,822.00 |
| Job Description: Single family residence |
| Type: CN |
Contractor
VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CBC1262114 (Exp: 08/31/2026) | 386-236-4133 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
HUGH MACDONALD
| Status | Location Address | State License Number |
| INACTIVE |
10825 TOM FOLSOM ROAD, SUITE A THONOTOSASSA, FL 33592 |
CCC1329562 (Exp: 08/31/2024) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/09/2024 | FINAL APPROVED | JSTEWART |
| Note: 8/8/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/8/2024 2:05:58 PM *** 1. Exterior future lights need weatherproof covers installed. (temp covers installed) 2. Condensation discharge needs to be 12" from foundation wall. FBCR 318.5 3. Dryer needs GFCI protection. NEC 210.8 4. refridgerator receptacle needs GFCI protection. NEC 210.8 5. Microwave needs GFCI protection. NEC 210.8 | |||
| BLD - BUILDING FINAL | 08/08/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 8/8/2024 2:05:58 PM *** 1. Exterior future lights need weatherproof covers installed. (temp covers installed) 2. Condensation discharge needs to be 12" from foundation wall. FBCR 318.5 3. Dryer needs GFCI protection. NEC 210.8 4. refridgerator receptacle needs GFCI protection. NEC 210.8 5. Microwave needs GFCI protection. NEC 210.8 | |||
| U -UTILITY RESIDENTIAL FINAL | 08/01/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/1/2024 11:23:39 AM *** raise sewer clean out so not to get grown over with sod-send pic when corrected | |||
| U-CROSS CONNECTION | 08/01/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/1/2024 11:22:20 AM *** reclaim master backflow-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 07/31/2024 | APPROVED | EMADISON |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/31/2024 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/31/2024 | APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 07/31/2024 | APPROVED | EMADISON |
| ELECTRIC - EARLY POWER | 07/25/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 7/25/2024 10:35:30 AM *** Note to Builder: the window wall of garage the exterior caps will need to be weatherproof caps before final, or lights installed. | |||
| ROW- PRE-APRON (PRE-POUR) | 07/03/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 07/03/24 READY TO SET PAVERS ___________________________________________________________________________________________________________________ 6/21/2024 - PREVIOUS INSPECTION NOTES 6/21/24= MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVER DETAIL. WHEN INSTALLING THE SUB-BASE OR PAVER BASE SAND, YOU NEED TO CALL FOR A NEW INSPECTION ONCE COMPACTION IS DONE. THE BASE CAN NO LONGER BE LEFT IN A PILE ON-SITE AND MUST BE SPREAD AND COMPACTED BEFORE THE SECOND PART OF A PRE-POUR FOR PAVERS CAN BE APPROVED | |||
| ROW- PAVER RESTRAINTS | 06/21/2024 | APPROVED | GBERTOLA |
| Note: READY TO POUR | |||
| ROW- PRE-APRON (PRE-POUR) | 06/21/2024 | PARTIALLY APPROVED | GBERTOLA |
| Note: 6/21/24= MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVER DETAIL. WHEN INSTALLING THE SUB-BASE OR PAVER BASE SAND, YOU NEED TO CALL FOR A NEW INSPECTION ONCE COMPACTION IS DONE. THE BASE CAN NO LONGER BE LEFT IN A PILE ON-SITE AND MUST BE SPREAD AND COMPACTED BEFORE THE SECOND PART OF A PRE-POUR FOR PAVERS CAN BE APPROVED | |||
| LATH/BRICK/ WATER BARRIER | 06/05/2024 | APPROVED | JWALKER |
| INSULATION | 06/04/2024 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2420 1. Rear slider being installed. 2. 5' head test is not holding water. 3. Seal the line set sleeve. 4. Tighten all wire clamps at the interior electical panels. Check for corrections at the insulation inspection. | |||
| ALL ROUGH | 05/31/2024 | APPROVED - AS NOTED | JWALKER |
| Note: 1. Rear slider being installed. 2. 5' head test is not holding water. 3. Seal the line set sleeve. 4. Tighten all wire clamps at the interior electical panels. Check for corrections at the insulation inspection. | |||
| ELECTRIC-TUG | 05/28/2024 | APPROVED | JWALKER |
| GRAVITY SEWER TEST | 05/23/2024 | APPROVED | MGIBSON |
| SEWER TIE IN | 05/23/2024 | APPROVED | MGIBSON |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/22/2024 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 05/13/2024 | APPROVED | JSTEWART |
| ROOF SHEATHING | 05/07/2024 | APPROVED | FWILLIS |
| Note: 5/6/2024 - PREVIOUS INSPECTION NOTES | |||
| ROOF SHEATHING | 05/06/2024 | CANCELLED BY APPLICANT | FWILLIS |
| WALL SHEATHING | 05/06/2024 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 04/23/2024 | APPROVED | JWALKER |
| Note: 4/9/2024 - PREVIOUS INSPECTION NOTES Missing multiple down cells. The dowel layout shown on page FD1 of the approved drawings has not been followed contractor is missing multiple dowel throught out the building. | |||
| TIE BEAM / LINTEL | 04/09/2024 | Disapproved - NO FEE | JWALKER |
| Note: Missing multiple down cells. The dowel layout shown on page FD1 of the approved drawings has not been followed contractor is missing multiple dowel throught out the building. | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/08/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 03/27/2024 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 03/27/2024 | APPROVED | CBOWERMASTER |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/12/2024 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/13/2024 | 05/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/19/2024 | 04/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/09/2024 | 04/10/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM Foundation Plan S101. A minimum of (1) # 4 rebar is required at each side of a opening Equal to or greater that 2'. Dowels missing at multiple openings. R608.8.1.2 | |||
| ENGIN1 | COMPLETE | 04/08/2024 | 04/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/08/2024 | 04/08/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/20/2024 | 02/23/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/20/2024 | 02/23/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/06/2024 | 02/06/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/06/2024 | 02/08/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector and outside disconnects. NEC 2020 230.67, 230.85 4. Need correct outlet spacing on wall by slider and switches. NEC 2020 210.52 | |||
| MECH | COMPLETE | 02/06/2024 | 02/07/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/06/2024 | 02/12/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Truss packet or truss plan needs to have shop drawing approval by engineer of record who designed the house. (Second Request) | |||
| CUSVC | COMPLETE | 02/06/2024 | 02/07/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/06/2024 | 02/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/06/2024 | 02/07/2024 |
| LOCATE | COMPLETE | 02/06/2024 | 02/09/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/06/2024 | 02/14/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 02/06/2024 | 02/07/2024 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 01/29/2024 | 02/01/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss plan needs to have shop drawing approval by engineer of record who designed the house. | |||
| BLD | COMPLETE | 01/29/2024 | 01/30/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 01/29/2024 | 02/02/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 01/29/2024 | 01/30/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical plan and electrical riser diagram. | |||
| ENGIN1 | COMPLETE | 01/29/2024 | 01/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 01/29/2024 | 01/31/2024 |
| LOCATE | COMPLETE | 01/29/2024 | 02/01/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/29/2024 | 01/31/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide floor plan. One submitted is roof framing plan | |||
| SW1 | COMPLETE | 01/29/2024 | 02/05/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/29/2024 | 01/30/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Can not fully review this permit as there is no floor plan or elevation plan provided. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/09/2024 |
| CONNECTION FEES | ¤25.00 | 02/29/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 02/29/2024 |
| IMPACT FEE FIRE | ¤428.09 | 02/29/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/29/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/29/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 02/29/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 02/29/2024 |
| IMPACT FEE TRANSPORTATION | ¤3,404.00 | 02/29/2024 |
| SURCHARGE FS 533.721 | ¤9.96 | 02/29/2024 |
| SURCHARGE - FS 468.631 | ¤14.95 | 02/29/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/29/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/29/2024 |
| SW ENG PRE APRON | ¤30.00 | 02/29/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/29/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/29/2024 |
| SEWER INSPECTION | ¤25.00 | 02/29/2024 |
| SITE PLAN 30 | ¤30.00 | 02/29/2024 |
| WATER-METER | ¤514.49 | 02/29/2024 |
| ADJUSTMENT 50% | (¤996.34) | 02/29/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/29/2024 |
| INSPECTION - RESIDENTIAL | ¤1,529.00 | 02/29/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤433.68 | 02/29/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,636.82 |