I want to search for...
Permit #2024020032
Permit Details
Status: FINAL
| Parcel Id: 34-10-30-5860-00000-00D0 |
| Subdivision: 5860 - |
| Job Phone: 877-906-1113 |
| Location Address: 126 REDBUD RD |
| Type: CE - COMMERCIAL ELECTRIC |
| Issue Date: 02/07/2024 |
| NOC: Unknown |
| Applicant name: JOSEPH HORATIO STRADA JR |
| Owner: TRAILS OF PALM COAST HOMEOWNERS ASSOCIATION INC |
|
Address 2695 DOBBS ROAD ST. AUGUSTINE, FL 32086 |
| Contracted Stated Job Value: ¤1,200.00 |
| Job Description: 200amp irrigation service pedestal |
| Type: CN |
Contractor
STRADA SERVICES LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 06/14/2024 | FINAL APPROVED | RMARTIN |
| Note: 6/7/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JMUNSON 6/7/2024 9:38:41 AM *** Pump calls for a max breaker of 30 amps not 40. 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24 Power release emailed FPL @ 10am. Call in final once meter is set 5/13/2024 - PREVIOUS INSPECTION NOTES 5/13/24 Make ALL repairs before calling in re-inspection 3/27/2024 - PREVIOUS INSPECTION NOTES 3/27/24 3/27/24 1. No approved plans on site FBC 107.3.1 2. Breakers are required to be labeled NEC 210.5 3. Ground wire must be protected NEC 250.64 Liquid tight is not approved for protection 4. Liquid tight can not be in areas subjust to physical damaage NEC 356.12 5. Still can not see ground rod connections to verify (j-jrs not approved for connection) 6. Address is wrong on permit address 194 is a residential home, 194 is the lot number not address 3/21/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE | |||
| ELECTRIC FINAL | 06/07/2024 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: *** NOTES ADDED BY JMUNSON 6/7/2024 9:38:41 AM *** Pump calls for a max breaker of 30 amps not 40. 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24 Power release emailed FPL @ 10am. Call in final once meter is set 5/13/2024 - PREVIOUS INSPECTION NOTES 5/13/24 Make ALL repairs before calling in re-inspection 3/27/2024 - PREVIOUS INSPECTION NOTES 3/27/24 3/27/24 1. No approved plans on site FBC 107.3.1 2. Breakers are required to be labeled NEC 210.5 3. Ground wire must be protected NEC 250.64 Liquid tight is not approved for protection 4. Liquid tight can not be in areas subjust to physical damaage NEC 356.12 5. Still can not see ground rod connections to verify (j-jrs not approved for connection) 6. Address is wrong on permit address 194 is a residential home, 194 is the lot number not address 3/21/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE | |||
| ELECTRIC FINAL | 05/15/2024 | PARTIALLY APPROVED | MKRASKI |
| Note: 5/15/24 Power release emailed FPL @ 10am. Call in final once meter is set 5/13/2024 - PREVIOUS INSPECTION NOTES 5/13/24 Make ALL repairs before calling in re-inspection 3/27/2024 - PREVIOUS INSPECTION NOTES 3/27/24 3/27/24 1. No approved plans on site FBC 107.3.1 2. Breakers are required to be labeled NEC 210.5 3. Ground wire must be protected NEC 250.64 Liquid tight is not approved for protection 4. Liquid tight can not be in areas subjust to physical damaage NEC 356.12 5. Still can not see ground rod connections to verify (j-jrs not approved for connection) 6. Address is wrong on permit address 194 is a residential home, 194 is the lot number not address 3/21/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE | |||
| ELECTRIC FINAL | 05/13/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 5/13/24 Make ALL repairs before calling in re-inspection 3/27/2024 - PREVIOUS INSPECTION NOTES 3/27/24 3/27/24 1. No approved plans on site FBC 107.3.1 2. Breakers are required to be labeled NEC 210.5 3. Ground wire must be protected NEC 250.64 Liquid tight is not approved for protection 4. Liquid tight can not be in areas subjust to physical damaage NEC 356.12 5. Still can not see ground rod connections to verify (j-jrs not approved for connection) 6. Address is wrong on permit address 194 is a residential home, 194 is the lot number not address 3/21/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE | |||
| ELECTRIC FINAL | 03/27/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/27/24 3/27/24 1. No approved plans on site FBC 107.3.1 2. Breakers are required to be labeled NEC 210.5 3. Ground wire must be protected NEC 250.64 Liquid tight is approved for protection 4. Liquid tight can not be in areas subjust to physical damaage NEC 356.12 5. Still can not see ground rod connections to verify (j-jrs not approved for connection) 6. Address is wrong on permit address 194 is a residential home, 194 is the lot number not address 3/21/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE | |||
| ELECTRIC FINAL | 03/21/2024 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: NEED TO HAVE SCH. 80 PVC WHERE SUBJECT TO PHYSICAL DAMAGE NEC 300.5, NEED TO UN-COVER GROUND RODS TO BE INSPECTED, NEED TO PROVIDE SITE STICKS FOR SERVICE CONDUIT DEPTH, NEED APPROVED PLANS ON SITE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 02/02/2024 | 02/05/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/01/2024 | 02/01/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to apply for a commercial electrical permit. 2. You always need to submit a electrical riser diagram that includes all wire sizes, breaker sizes and GFCI protection. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 06/11/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 05/13/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 03/29/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 03/21/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/07/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/07/2024 |
| ADJUSTMENT 50% | (¤83.75) | 02/07/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 02/07/2024 |
| INSPECTION- ELECTRICAL | ¤60.00 | 02/07/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 02/07/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤327.75 |