I want to search for...

Permit #2024020073

Permit Details

Status: CANCEL

CONDITIONED SPACE: 1847 sqft
GARAGE: 462 sqft
OPENED PORCH (WITH ROOF) : 41 sqft
OPENED PORCH (WITH ROOF) : 125 sqft
Total Square Footage: 2475 sqft
Subdivision: -
Job Phone: 844-885-8913
Location Address: 123 MASTER PERMIT
Type: MASTRE - MASTER RESIDENTIAL
NOC: NO DOCUMENTATION
Applicant name: SIMON DALE VANWAGENEN
Owner: THIS IS A TEST RECORD
Contracted Stated Job Value: ¤239,124.37
Job Description: SINGLE FAMILY RESIDENCE - HILLCREST MODEL
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
FOUND SURVEY APPROVED (OFFICE)
PLUMBING 1ST ROUGH UNDERGROUND
GRAVITY SEWER TEST
ELECTRIC - EARLY POWER
MONOLITHIC SLAB
LATH/BRICK/ WATER BARRIER
TIE BEAM / LINTEL
ALL ROUGH
WALL SHEATHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL
ROOF VALLEY & METAL
INSULATION
BLD - BUILDING FINAL
WATER METER INSTALLATION REQUEST
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
U - SEWER TIE IN
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - STORMWATER FINAL

Review History

Department Status Date In Date Out
BLD HOLD 02/02/2024 02/09/2024
Note: Held By: JIM WALKER - - JWALKER@PALMCOASTGOV.COM Product approval work sheet. 1. Mi window 17676 R21 not a prduct approval number 2. Please revise all product approval tnumbers to current code cycle.
ELEC HOLD 02/02/2024 02/02/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 3. Need correct outlet spacing in bed 4 NEC 2020 210.52 4. Need correct outlet spacing in master bed room. NEC2020 210.52 5. Need GFCI service outlet for AHU in attic. NEC 2020 210.63 6. Electrical load calcs need to be updated to the NEC 2020
MECH HOLD 02/02/2024 02/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans show R38 Insulation in attic. Energy Calcs say R30. Revise to match
ELEC CANCEL
MECH CANCEL
BLD CANCEL