I want to search for...

Permit #2024020129

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00520-0140
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00520
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 386-283-2035
Location Address: 11 PROSPECT LN
Type: DU - DUPLEX
Issue Date: 03/13/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: TARASOVA ANNA & ALEXANDER SHPERLING

Address

578 DUNHILL DRIVE

LAKE ZURICH, IL 60047

Lot: 0140
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/17/2024 FINAL APPROVED RSIMS
Note: 12/13/2024 - PREVIOUS INSPECTION NOTES 12/13/24: 1). Draft stop wall is not fully sealed at the top on the B side. FBC [A]107.4 2). B-side Master bathroom sink has a partially clogged overflow drain. (allows sink to overflow the edge). FBC-P405.8 Both Units: 3). Outdoor unit needs to be 3" above finished grade. FBCR M1305.1.4.1 4). Outdoor Condensing unit - Titeseal raceway from disconnect needs to be anchored at 12" max from disconnect. NEC-334.30 5). Door locksets and handles along with door seals have been removed for painting in process. FBC [A]107.4 6). Kitchen island wall outlet below counter cannot be on the small appliance circuit [NEC-210.52(B)(2)] & cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]
U-CROSS CONNECTION 12/13/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 12/13/2024 11:42:33 AM *** no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 12/13/2024 APPROVED TPOLACEK
Note: 12/13/24 TPOLACEK*** PAVERS ARE SET. PIPE ELEVATION IS GOOD CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 12/13/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 12/13/2024 FINAL APPROVED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 12/13/2024 12:00:52 PM *** contact city for new water metrr bix and get bth also,raised as discussed with ALX- BUILDER
BLD - BUILDING FINAL 12/13/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/13/2024 1:56:17 PM *** 12/13/24: 1). Draft stop wall is not fully sealed at the top on the B side. FBC [A]107.4 2). B-side Master bathroom sink has a partially clogged overflow drain. (allows sink to overflow the edge). FBC-P405.8 Both Units: 3). Outdoor unit needs to be 3" above finished grade. FBCR M1305.1.4.1 4). Outdoor Condensing unit - Titeseal raceway from disconnect needs to be anchored at 12" max from disconnect. NEC-334.30 5). Door locksets and handles along with door seals have been removed for painting in process. FBC [A]107.4 6). Kitchen island wall outlet below counter cannot be on the small appliance circuit [NEC-210.52(B)(2)] & cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/12/2024 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 12/12/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- PRE-APRON (PRE-POUR) 10/25/2024 APPROVED TPOLACEK
Note: 10/25/24 TPOLACEK** YOU ARE APPROVED TO LAY PAVERS. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2024 - PREVIOUS INSPECTION NOTES 10/23/24 TPOLACEK*** SPOKE WITH MITCH ABOUT FORM BOARD ACROSS THE ROW TO CONTAIN THE POUR TO JUST THE APRON/ROW. APPROVING AS NOTED . AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/21/2024 - PREVIOUS INSPECTION NOTES 10/21/24 TPOLACEK*** BUILDER NEEDS TO SUBMIT THE PAVER DETAIL THEY HAVE CHOSEN. THERE IS NO DETAIL SHEET ATTACHED TO PERMIT.
ROW- PAVER RESTRAINTS 10/23/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 10/23/2024 PARTIALLY APPROVED TPOLACEK
Note: 10/23/24 TPOLACEK*** SPOKE WITH MITCH ABOUT FORM BOARD ACROSS THE ROW TO CONTAIN THE POUR TO JUST THE APRON/ROW. APPROVING AS NOTED . AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/21/2024 - PREVIOUS INSPECTION NOTES 10/21/24 TPOLACEK*** BUILDER NEEDS TO SUBMIT THE PAVER DETAIL THEY HAVE CHOSEN. THERE IS NO DETAIL SHEET ATTACHED TO PERMIT.
ROW- PRE-APRON (PRE-POUR) 10/21/2024 Disapproved - NO FEE TPOLACEK
Note: 10/21/24 TPOLACEK*** BUILDER NEEDS TO SUBMIT THE PAVER DETAIL THEY HAVE CHOSEN. THERE IS NO DETAIL SHEET ATTACHED TO PERMIT.
ELECTRIC - EARLY POWER 09/23/2024 APPROVED RSIMS
Note: 9/23/24: FPL emailed to release power.
FIREWALL FINAL 09/06/2024 APPROVED RSIMS
Note: 9/4/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2443 9/4/24: Prfevious notes remain unresolved. *** NOTES ADDED BY RSIMS 9/3/2024 12:05:17 PM *** 9/3/24: Please complete prior to next inspection. 1). Please repair silt fence and have completed along the back of site. FBC 3307.1 2). Please clean up piles of trash/debris to make site safe for inspections.
FIREWALL FINAL 09/04/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/4/2024 1:44:23 PM *** Inspector Notes from Inspection 2443 9/4/24: Prfevious notes remain unresolved. *** NOTES ADDED BY RSIMS 9/3/2024 12:05:17 PM *** 9/3/24: Please complete prior to next inspection. 1). Please repair silt fence and have completed along the back of site. FBC 3307.1 2). Please clean up piles of trash/debris to make site safe for inspections.
FIREWALL DRYWALL NAILING 09/03/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/3/2024 12:05:17 PM *** 9/3/24: Please complete prior to next inspection. 1). Please repair silt fence and have completed along the back of site. FBC 3307.1 2). Please clean up piles of trash/debris to make site safe for inspections.
FIREWALL FINAL 08/29/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 8/29/2024 12:33:07 PM *** 8/29/24: 1). Drywall at back lanai ceiling appears to be 1/2" moisture rated sheetrock and not the 5/8" X rated as required by the 1hr rating on the plans. (sheetrock is not labeled for firecode & did not see any scrap pieces on site or in dumpster for comparison). 7/24/24: Firewall framing inspection was for the draft stop above the ceiling only. A Partial Firewall final inspection will be required before ceiling drywall is applied.
GRAVITY SEWER TEST 08/29/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 protection of property. need silt fence in place before next inspection
SEWER TIE IN 08/29/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 protection of property. need silt fence in place before next inspection
FIREWALL DRYWALL NAILING 08/26/2024 APPROVED KSANDOE
Note: 8/22/2024 - PREVIOUS INSPECTION NOTES 8/22/24: 1). Screw distance does not match fire code requirements (3" OC end and 7"OC in field). 7/31/2024 - PREVIOUS INSPECTION NOTES 7/31/24: This partial inspection is for the draft stop above the ceiling to view that it is sealed with joint compound, etc. properly. The Ceiling drywall will still need to be inspected for Nailing before finishing with joint compound. 7/24/24: Firewall framing inspection was for the draft stop above the ceiling only. A Partial Firewall final inspection will be required before ceiling drywall is applied. 7/2/2024 - PREVIOUS INSPECTION NOTES Revise detail to reflect change to draftstop in lieu of firewall. Trusses landed on CMU are inside the required space for 5/8 type X drywall as required by UL338. 6/28/2024 - PREVIOUS INSPECTION NOTES Must have building plans on site forr inspection.
FIREWALL DRYWALL NAILING 08/22/2024 Disapproved - NO FEE RSIMS
Note: 8/22/24: 1). Screw distance does not match fire code requirements (3" OC end and 7"OC in field). 7/31/2024 - PREVIOUS INSPECTION NOTES 7/31/24: This partial inspection is for the draft stop above the ceiling to view that it is sealed with joint compound, etc. properly. The Ceiling drywall will still need to be inspected for Nailing before finishing with joint compound. 7/24/24: Firewall framing inspection was for the draft stop above the ceiling only. A Partial Firewall final inspection will be required before ceiling drywall is applied. 7/2/2024 - PREVIOUS INSPECTION NOTES Revise detail to reflect change to draftstop in lieu of firewall. Trusses landed on CMU are inside the required space for 5/8 type X drywall as required by UL338. 6/28/2024 - PREVIOUS INSPECTION NOTES Must have building plans on site forr inspection.
INSULATION 08/13/2024 APPROVED RSIMS
Note: 8/9/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 8/9/2024 1:39:45 PM *** still missing fire stop at wires into top plates R302.11 8/7/2024 - PREVIOUS INSPECTION NOTES 8/7/24: * Unit B: (right side)(FBC-R302.11). 1). Missing firestop at garage electrical penetrations into CMU wall. 2). Missing firestop at top plate penetrations into attic space. Marked with FS below.
INSULATION 08/09/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 8/9/2024 1:39:45 PM *** still missing fire stop at wires into top plates R302.11 8/7/2024 - PREVIOUS INSPECTION NOTES 8/7/24: * Unit B: (right side)(FBC-R302.11). 1). Missing firestop at garage electrical penetrations into CMU wall. 2). Missing firestop at top plate penetrations into attic space. Marked with FS below.
INSULATION 08/07/2024 Disapproved - NO FEE RSIMS
Note: 8/7/24: * Unit B: (right side)(FBC-R302.11). 1). Missing firestop at garage electrical penetrations into CMU wall. 2). Missing firestop at top plate penetrations into attic space. Marked with FS below.
FIREWALL DRYWALL NAILING 07/31/2024 PARTIALLY APPROVED RSIMS
Note: 7/31/24: This partial inspection is for the draft stop above the ceiling to view that it is sealed with joint compound, etc. properly. The Ceiling drywall will still need to be inspected for Nailing before finishing with joint compound. 7/24/24: Firewall framing inspection was for the draft stop above the ceiling only. A Partial Firewall final inspection will be required before ceiling drywall is applied. 7/2/2024 - PREVIOUS INSPECTION NOTES Revise detail to reflect change to draftstop in lieu of firewall. Trusses landed on CMU are inside the required space for 5/8 type X drywall as required by UL338. 6/28/2024 - PREVIOUS INSPECTION NOTES Must have building plans on site forr inspection.
ALL ROUGH 07/30/2024 APPROVED RSIMS
Note: 7/24/2024 - PREVIOUS INSPECTION NOTES 7/24/24: Both Units: 1). Lineset is not run through the sleeve & sealed as required. (Will not be visible on Building Final). 2). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 3). Kitchen exhaust:> FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. Unit B (Right Side). 4). Master bedroom window is missing anchors on the right side jamb.
ALL ROUGH 07/24/2024 Disapproved - NO FEE RSIMS
Note: 7/24/24: Both Units: 1). Lineset is not run through the sleeve & sealed as required. (Will not be visible on Building Final). 2). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 3). Kitchen exhaust:> FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. Unit B (Right Side). 4). Master bedroom window is missing anchors on the right side jamb.
LATH/BRICK/ WATER BARRIER 07/24/2024 APPROVED RSIMS
Note: 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24: 1). Hole in CMU on the rear wall at the romex wire needs wire lath. 2). Overgrowth around entire site needs to be removed to make site safe for inspections.
FIREWALL FRAMING 07/24/2024 APPROVED - AS NOTED RSIMS
Note: 7/24/24: This inspection is for the draft stop above the ceiling only. A Firewall final partial inspection will be required before ceiling drywall is applied. 7/2/2024 - PREVIOUS INSPECTION NOTES Revise detail to reflect change to draftstop in lieu of firewall. Trusses landed on CMU are inside the required space for 5/8 type X drywall as required by UL338. 6/28/2024 - PREVIOUS INSPECTION NOTES Framing is covered by drywall. Unable to inspect. Framing members, truss ties, ridge poles and truss blocking cannot penetrate firewall.
ALL ROUGH 07/23/2024 CANCELLED BY APPLICANT WEB
ALL ROUGH 07/22/2024 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 07/22/2024 Disapproved - NO FEE RSIMS
Note: 7/22/24: 1). Hole in CMU on the rear wall at the romex wire needs wire lath. 2). Overgrowth around entire site needs to be removed to make site safe for inspections.
FIREWALL FRAMING 07/02/2024 Disapproved - NO FEE KSANDOE
Note: Revise detail to reflect change to draftstop in lieu of firewall. Trusses landed on CMU are inside the required space for 5/8 type X drywall as required by UL338. 6/28/2024 - PREVIOUS INSPECTION NOTES Framing is covered by drywall. Unable to inspect. Framing members, truss ties, ridge poles and truss blocking cannot penetrate firewall.
FIREWALL DRYWALL NAILING 06/28/2024 Disapproved - NO FEE KSANDOE
Note: Must have building plans on site forr inspection.
FIREWALL FRAMING 06/28/2024 Disapproved - NO FEE KSANDOE
Note: Framing is covered by drywall. Unable to inspect. Framing members, truss ties, ridge poles and truss blocking cannot penetrate firewall.
ROOF VALLEY & METAL 06/21/2024 APPROVED KSANDOE
WALL SHEATHING 06/17/2024 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/17/2024 APPROVED AGAETANO
TIE BEAM / LINTEL 05/21/2024 APPROVED KSANDOE
Note: 5/20/2024 - PREVIOUS INSPECTION NOTES 5/20/24: Met Superintendent upon arrival. Requested to cancel.
TIE BEAM / LINTEL 05/20/2024 CANCELLED BY APPLICANT RSIMS
Note: 5/20/24: Met Superintendent upon arrival. Requested to cancel.
FOUND SURVEY APPROVED (OFFICE) 05/17/2024 APPROVED TDOAK
MONOLITHIC SLAB 05/09/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 05/06/2024 APPROVED - AS NOTED MGIBSON
Note: 3307.1 protection of property. need silt fence in place before next inspection
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/03/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 03/20/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/21/2024 10/23/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
SW1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2024 09/05/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/04/2024 09/04/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 09/03/2024 09/03/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide driveway apron width at edge of pavement COPC Techinical Manual, Section 300.01 (A)(1)(C)(1)
ZON HOLD 09/03/2024 09/03/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit original Right of Way Utilization Agreement for Paver Driveway.
BLD COMPLETE 07/16/2024 07/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/17/2024 05/17/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/17/2024 05/17/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 05/07/2024 05/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/30/2024 05/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 04/03/2024 04/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 03/28/2024 04/02/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor
MECH COMPLETE 03/05/2024 03/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 03/03/2024 03/04/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 2023 Energy calcs need to be signed. 2022 Energy calcs were uploaded
ELEC COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 02/20/2024 02/21/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH HOLD 02/20/2024 02/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
BLD COMPLETE 02/20/2024 02/22/2024
Note: Released By: JPI
BADMIN COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/20/2024 02/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 02/05/2024 02/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) (YOU ARE MISSING (B) THE TRUSS LAYOUT AND (D) THE STAMP FROM THE ENGINEER OF RECORD. YOU CANNOT SUBMIT A LETTER. THE APPROVAL STAMP NEEDS TO BE ON THE FIRST PAGE OF THE TRUSS PACKET OR TRUSS LAYOUT.)
BLD HOLD 02/05/2024 02/09/2024
Note: Held By: JPI 1. Provide appropriate revision numbers (i.e. R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 107.2.4 2. Provide specific product numbers (i.e. 11473.# R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 107.2.4 3. Provide correct Florida Product Approval (FPA) number for ALL products listed on Product Approval Specification Sheet; composite lumber number appears incorrect. 5. Florida Product Approval number for Roofing Underlayment does NOT match the one indicated on the Roofing Worksheet. 107.2.4 6. Provide roof ventilation calculations for required number and size of roof vents; identify size on plans and elevations. 107.2.4 7. Provide/indicate what elevation lines represent on ALL elevations; dimensions have been provided, however nothing indicates what they are dimensioning to. 107.3.5 8. Identify U.L. number for “upper tenant firewall detail” drawing on Sht. 2. Chapter 7 9. Provide U.L. Listing from ULC Online Directories for UL338; similar to U905 provided on Sht. 3. Chapter 7 10. Detail 4 on Sht. 3 identifies as a firewall detail but no U.L. Listing is provided. Chapter 7 11. Under “General” on Sht. 4 states, “all connectors shown in these drawings can be substituted with other suitable connectors”; substitutions shall have Florida Product Approval numbers. 107.2.4 12. “Common Wire To Gun Nail Conversion” table on Sht. 8 is difficult to read; numbers have been placed over numbers. 107.3.5
CUSVC COMPLETE 02/05/2024 02/07/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 02/05/2024 02/05/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8
ENGIN1 COMPLETE 02/05/2024 02/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 02/05/2024 02/06/2024
MECH HOLD 02/05/2024 02/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy calcs from the 2023 code cycle
SW1 COMPLETE 02/05/2024 02/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 02/05/2024 02/05/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan:Map panel number incorrect should be 0138E. Driveway in 16' per side 16 ft min: 2.Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet.
SWALE COMPLETE 02/05/2024 03/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/13/2024
REINSPECTION RESIDENTIAL ¤40.00 12/10/2024
RECORDING FEE REIMBURSE DOC ¤44.00 09/03/2024
REINSPECTION RESIDENTIAL ¤40.00 08/28/2024
WATER- TURN ON ¤50.00 03/13/2024
ADJUSTMENT 50% (¤821.61) 03/13/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/13/2024
INSPECTION - RESIDENTIAL ¤1,256.75 03/13/2024
PLAN REVIEW - RESIDENTIAL ¤356.46 03/13/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 03/13/2024
WATER -IRRIGATION INSPECTION ¤50.00 03/13/2024
SURCHARGE FS 533.721 ¤8.22 03/13/2024
SURCHARGE - FS 468.631 ¤12.32 03/13/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/13/2024
SW ENG INSPECTION 80 ¤80.00 03/13/2024
SW ENG PRE APRON ¤30.00 03/13/2024
SW ENG - REVIEW 20 ¤20.00 03/13/2024
SW ENG RES REVIEW 200 ¤200.00 03/13/2024
SEWER INSPECTION ¤25.00 03/13/2024
SEWER CAPITAL FACILITY ¤10,882.06 03/13/2024
WATER CAPITAL FACILITY FEE ¤7,989.02 03/13/2024
SITE PLAN 30 ¤30.00 03/13/2024
CONNECTION FEES ¤2,374.52 03/13/2024
FC IMPACT FEE EMS ¤124.00 03/13/2024
IMPACT FEE FIRE ¤856.18 03/13/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 03/13/2024
FC IMPACT FEE LIBRARY ¤536.00 03/13/2024
IMPACT FEE PARKS ¤3,600.18 03/13/2024
IMPACT FEE SCHOOL ¤10,900.00 03/13/2024
Fees Total Due: ¤0.00 Total Paid: ¤42,099.10