I want to search for...

Permit #2024020160

Permit Details

Status: COED

Parcel Id: 07-11-31-7013-00010-0150
CONDITIONED SPACE: 1574 sqft
GARAGE: 402 sqft
OPENED PORCH (WITH ROOF) : 31 sqft
PATIO/DECK (NO ROOF) : 54 sqft
Total Square Footage: 2061 sqft
Block: 00010
Subdivision: 2192 - SECTION 13-BELLE TERRE
Job Phone: 904-531-5923
Location Address: 48 BRADMORE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/05/2024
NOC: RECORDED
Applicant name: TAVARIS JEROME DAVIS
Owner: BRIGHTLAND HOMES OF FLORIDA LLC

Address

15725 N DALLAS PARKWAY SUITE 300

ADDISON , TX 75001

Lot: 0150
Contracted Stated Job Value: ¤250,000.00
Job Description: Single Family Residence
Type: CN

Contractor

BRIGHTLAND HOMES OF FLORIDA, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

3505 EAST FRONTAGE RD

ADDISON, TX 75001

STE 145

TAMPA, FL 33607

CBC1267320 (Exp: 08/31/2026) 904-531-5923

Sub Contractors

LARRY LAVON TURNAGE
Status Location Address State License Number Phone
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

CMC1249777 (Exp: 08/31/2024) 407-333-2665
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
OLIN MARSHALL CANNON
Status Location Address State License Number Phone
INACTIVE

1794 ROGERO RD #2

JACKSONVILLE, FL 32211

CFC1426140 (Exp: 08/31/2026) 904-343-4344
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/12/2024 FINAL APPROVED JSTEWART
Note: New inspection due to canceled inspection 9/10/2024 - PREVIOUS INSPECTION NOTES Please raise ODU Pad for 3" clearence from surrounding ground. FBCM 304.10 Faucet in guest bath is loose 9/5/2024 - PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 09/11/2024 CANCELLED BY APPLICANT WEB
Note: 9/10/2024 - PREVIOUS INSPECTION NOTES Please raise ODU Pad for 3" clearence from surrounding ground. FBCM 304.10 Faucet in guest bath is loose 9/5/2024 - PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 09/10/2024 Disapproved - NO FEE KSANDOE
Note: Please raise ODU Pad for 3" clearence from surrounding ground. FBCM 304.10 Faucet in guest bath is loose 9/5/2024 - PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 09/05/2024 CANCELLED BY APPLICANT AWATERS
U -UTILITY RESIDENTIAL FINAL 09/05/2024 FINAL APPROVED DHANEY
U-CROSS CONNECTION 09/04/2024 APPROVED DHANEY
ROW - FINAL APRON (AFTER POUR) 09/04/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/04/2024 APPROVED TPOLACEK
Note: 09/04/24 TPOLACEK** CORRECTION TO LEFT SIDE DRAINAGE COMPLETED. 8/28/2024 - PREVIOUS INSPECTION NOTES THE LEFT SIDE DRAINAGE PATTERN IS HOLDING WATER BETWEEN THE HOUSES. IT IS NOT ABLE TO MAKE IT TO THE FRON ROADSIDE SWALE. I KNOW THIS BECAUSE IT IS DRY CLOSER TO THE SWALE AND WET BEHIND IT. NEED TO MAKE ALL WATER FLOW TO ROADSIDE SWALE
ROW - STORMWATER FINAL 09/04/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/28/2024 Disapproved - NO FEE PFLANAGAN
Note: THE LEFT SIDE DRAINAGE PATTERN IS HOLDING WATER BETWEEN THE HOUSES. IT IS NOT ABLE TO MAKE IT TO THE FRON ROADSIDE SWALE. I KNOW THIS BECAUSE IT IS DRY CLOSER TO THE SWALE AND WET BEHIND IT. NEED TO MAKE ALL WATER FLOW TO ROADSIDE SWALE
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/28/2024 APPROVED PFLANAGAN
Note: THIS SHOULD HAVE BEEN PASSED DISAPPROVING THE FIELD ------------------------------------------------------------------- 8/28/2024 - PREVIOUS INSPECTION NOTES THE LEFT SIDE DRAINAGE PATTERN IS HOLDING WATER BETWEEN THE HOUSES. IT IS NOT ABLE TO MAKE IT TO THE FRON ROADSIDE SWALE. I KNOW THIS BECAUSE IT IS DRY CLOSER TO THE SWALE AND WET BEHIND IT. NEED TO MAKE ALL WATER FLOW TO ROADSIDE SWALE
ROW FIELD SURVEY /GRADING CERTIFICATION 08/28/2024 Disapproved - NO FEE PFLANAGAN
Note: THE LEFT SIDE DRAINAGE PATTERN IS HOLDING WATER BETWEEN THE HOUSES. IT IS NOT ABLE TO MAKE IT TO THE FRON ROADSIDE SWALE. I KNOW THIS BECAUSE IT IS DRY CLOSER TO THE SWALE AND WET BEHIND IT. NEED TO MAKE ALL WATER FLOW TO ROADSIDE SWALE
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/21/2024 Disapproved - NO FEE EMADISON
Note: ** 08/21/24 CUVERT PIPE IS OUT OF TOLERANCE IN ACCORDANCE WITH THE CITY OF PALM COASTS SWALE PLAN DIAGRAM ** Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ELECTRIC - EARLY POWER 07/09/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 7/9/2024 8:59:33 AM *** Authorize release of email to FPL 6/28/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 6/28/2024 11:38:42 AM *** 1. Please enclose wires dfor Hot water tank into a closed holding box. 2. Please safe of pantry Light. 3. Please safe off pantry light switch. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 5/8/2024 2:11:57 PM *** 5/8/24- Authorize release of email to FPL @ 2:11p
ROW- PRE-APRON (PRE-POUR) 07/09/2024 APPROVED - AS NOTED TPOLACEK
Note: 07/09/24 TPOLACEK*** FORM BOARDS IN ALL POUR AREA MUST MEET THE GROUND OR BE BACKFILLED TO PREVENT OVERPOUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 7/8/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 07/08/2024 CANCELLED BY APPLICANT EMADISON
ELECTRIC - EARLY POWER 06/28/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 6/28/2024 11:38:42 AM *** 1. Please enclose wires dfor Hot water tank into a closed holding box. 2. Please safe of pantry Light. 3. Please safe off pantry light switch. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 5/8/2024 2:11:57 PM *** 5/8/24- Authorize release of email to FPL @ 2:11p
GRAVITY SEWER TEST 05/22/2024 APPROVED MGIBSON
SEWER TIE IN 05/22/2024 APPROVED MGIBSON
INSULATION 05/21/2024 APPROVED FWILLIS
Note: 5/13/2024 - PREVIOUS INSPECTION NOTES NO INSULATION ON SITE. FIRE CAULKING BEING INSTALLED.
INSULATION 05/13/2024 Disapproved -FEE REQUIRED FWILLIS
Note: NO INSULATION ON SITE. FIRE CAULKING BEING INSTALLED.
INSULATION 05/10/2024 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 05/08/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 5/8/2024 2:11:57 PM *** 5/8/24- Authorize release of email to FPL @ 2:11p
LATH/BRICK/ WATER BARRIER 05/08/2024 APPROVED JSTEWART
Note: 4/23/2024 - PREVIOUS INSPECTION NOTES
ALL ROUGH 05/08/2024 APPROVED JSTEWART
LATH/BRICK/ WATER BARRIER 04/23/2024 CANCELLED BY APPLICANT JSTEWART
ROOF VALLEY & METAL 04/22/2024 APPROVED FWILLIS
WALL SHEATHING 04/18/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/18/2024 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 04/17/2024 APPROVED AMOBLEY
MONOLITHIC SLAB 04/04/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 04/03/2024 APPROVED MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 04/01/2024 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 04/01/2024 Disapproved - NO FEE KSANDOE
Note: Contact CBO Patrick Buckley
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/28/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 03/18/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 08/14/2024 08/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 07/24/2024 07/24/2024
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT 2023 FBC BLOWER DOOR TEST https://copc-strapi-production.s3.amazonaws.com/Blower_Door_test_Form_8_TH_EDITION_9529e9c414.pdf
ENGIN1 COMPLETE 04/16/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/16/2024 04/16/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 04/02/2024 04/02/2024
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM The notice to use a private provider was not submitted as requried by Florida Statute prior to the first inspection. The 1st rough plumbing will need to be re-requested for inspection by a city building inspector. The priviate provider inspection report will not be accepted.
BADMIN INFORMATION 04/01/2024 04/01/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The notice to use a private provider was not submitted as requried by Florida Statute prior to the first inspection. The 1st rough plumbing will need to be re-requested for inspection by a city building inspector. The priviate provider inspection report will not be accepted.
BLD COMPLETE 03/26/2024 03/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 03/22/2024 03/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Letter must be accompanied by a signed and sealed inspection and certification letter by the geotechnical engineer of record. Engineer’s letter to confirm the following: Site clearing / over excavation was completed and inspected by engineer prior to the placement of fill and engineer confirms clearing and over excavation work is acceptable. Engineer to confirm fill materials were suitable and within specifications. Engineer to confirm the required number and location of field density tests were completed. Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4) Field dentisty Test Must be digiutally signed and sealed.
BLD COMPLETE 02/29/2024 03/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 02/23/2024 02/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2024 02/23/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 02/23/2024 02/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 02/23/2024 02/25/2024
Note: Held By: JPI 1. Provide specific product numbers including current revisions (i.e. 11473.# R6) for ALL products listed on Product Approval Specification Sheet. 2. Provide roof underlayment and shingle revision number on Florida Product Approval Specification Sheet that corresponds with the Roofing Worksheet; underlayment Florida Product Approval. The number on Roofing Worksheet does not include revision number. 107.2.4. Repeating comment. 3. Provide Florida Product Approval number for shutters. 107.2.4. Repeating comment.
BADMIN COMPLETE 02/23/2024 02/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 02/06/2024 03/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 02/05/2024 02/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) (YOU ARE MISSING (D) THE STAMP FROM THE ENGINEER OF RECORD. YOU CANNOT SUBMIT A LETTER. THE APPROVAL STAMP NEEDS TO BE ON THE FIRST PAGE OF THE TRUSS PACKET OR TRUSS LAYOUT.)
BLD HOLD 02/05/2024 02/09/2024
Note: Held By: JPI 1. City of Palm Coast Color and Material Sheet (form) appears OMITTED from submission. FBC 105 2. Provide specific product numbers including current revisions (i.e. 11473.# R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 3. Provide roof underlayment and shingle revision number on Florida Product Approval Specification Sheet that corresponds with the Roofing Worksheet; underlayment Florida Product Approval number on Roofing Worksheet does not include revision number. 107.2.4 4. Provide Florida Product Approval number for shutters. 107.2.4 5. Architectural drawings do NOT have a signed seal by the Architect of Record/Engineer of Record. 6. Reference to 2023 Florida Residential Code, Section R302.3. 7. Provide elevation (height) for Second Floor on ALL Elevations. 107.3.5 8. Provide pitch/slopes of ALL roofs on the Elevations.. R802
CUSVC COMPLETE 02/05/2024 02/12/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 02/05/2024 02/06/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 02/05/2024 02/06/2024
LOCATE COMPLETE 02/05/2024 02/06/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 02/05/2024 02/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans 2x4 walls. Energy Calcs say R19. Revise to correct insulation
SW1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 02/05/2024 02/06/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan: To recieve credit for the tree located in the front it must be on the with in the property lines front tree is not . Mechanical equiptment must be screened with 7 gallons per LDC. Elevation page is missing the roof pitch, please provide.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/24/2024
REINSPECTION RESIDENTIAL ¤40.00 10/24/2024
REINSPECTION RESIDENTIAL ¤40.00 10/24/2024
CONNECTION FEES ¤1,187.26 03/05/2024
CONNECTION FEES (¤750.00) 03/05/2024
CONTRACTOR CHANGE ¤20.00 03/05/2024
CONTRACTOR CHANGE ¤20.00 03/05/2024
FC IMPACT FEE EMS ¤62.00 03/05/2024
IMPACT FEE FIRE ¤428.09 03/05/2024
IMPACT FEE FIRE ¤428.09 03/05/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/05/2024
FC IMPACT FEE LIBRARY ¤268.00 03/05/2024
IMPACT FEE PARKS ¤1,800.99 03/05/2024
IMPACT FEE PARKS ¤1,800.99 03/05/2024
IMPACT FEE SCHOOL ¤5,450.00 03/05/2024
IMPACT FEE SCHOOL ¤5,450.00 03/05/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 03/05/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 03/05/2024
WATER -IRRIGATION INSPECTION ¤25.00 03/05/2024
SURCHARGE FS 533.721 ¤5.32 03/05/2024
SURCHARGE - FS 468.631 ¤7.98 03/05/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/05/2024
SW ENG INSPECTION 80 ¤80.00 03/05/2024
SW ENG PRE APRON ¤30.00 03/05/2024
SW ENG - REVIEW 20 ¤20.00 03/05/2024
SW ENG RES REVIEW 200 ¤200.00 03/05/2024
SEWER INSPECTION ¤25.00 03/05/2024
SEWER INSPECTION (¤25.00) 03/05/2024
SEWER CAPITAL FACILITY ¤5,441.03 03/05/2024
SEWER CAPITAL FACILITY (¤3,030.00) 03/05/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 03/05/2024
WATER CAPITAL FACILITY FEE (¤2,160.00) 03/05/2024
SITE PLAN 30 ¤30.00 03/05/2024
WATER- TURN ON ¤25.00 03/05/2024
WATER- TURN ON (¤25.00) 03/05/2024
ADJUSTMENT 50% (¤532.15) 03/05/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/05/2024
INSPECTION - RESIDENTIAL ¤805.75 03/05/2024
PLAN REVIEW - RESIDENTIAL ¤228.54 03/05/2024
Fees Total Due: ¤0.00 Total Paid: ¤25,415.90