Permit #2024020162

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00120-0260
CONDITIONED SPACE: 1851 sqft
GARAGE: 411 sqft
OPENED PORCH (WITH ROOF) : 39 sqft
OPENED PORCH (WITH ROOF) : 74 sqft
Total Square Footage: 2375 sqft
Block: 00120
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: 904-531-5923
Location Address: 85 FORSYTHE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/12/2024
NOC: RECORDED
Applicant name: TAVARIS JEROME DAVIS
Owner: BRIGHTLAND HOMES OF FLORIDA LLC

Address

1572 N DALLAS PARKWAY SUITE 300

ADDISON , TX 75001

Lot: 0260
Contracted Stated Job Value: ¤250,000.00
Job Description: Single Family Construction
Type: CN

Contractor

BRIGHTLAND HOMES OF FLORIDA, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

3505 EAST FRONTAGE RD

ADDISON, TX 75001

STE 145

TAMPA, FL 33607

CBC1267320 (Exp: 08/31/2026) 904-531-5923

Sub Contractors

LARRY LAVON TURNAGE
Status Location Address State License Number Phone
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

CMC1249777 (Exp: 08/31/2024) 407-333-2665
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
OLIN MARSHALL CANNON
Status Location Address State License Number Phone
INACTIVE

1794 ROGERO RD #2

JACKSONVILLE, FL 32211

CFC1426140 (Exp: 08/31/2026) 904-343-4344
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/31/2025 FINAL APPROVED HCAMACHO
Note: 1/30/2025 - PREVIOUS INSPECTION NOTES 1/28/2025 - PREVIOUS INSPECTION NOTES 1. There's material on the roof that's not supposed to be there at front Entrance. 2. Outlet in Hall between bedrooms next to hall bath needs to be GFCI, within 6' of sink. NEC 210.8 3. Power coming from ceiling in A/C closet needs to be sealed.R402.4.1.1 4. Please post Termite Certificate on Breaker Panel.FBC [A] 105.11
BLD - BUILDING FINAL 01/30/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 1/30/2025 8:38:06 AM *** 1/30/25: Cancelled by Applicant via text at @ 08:24. 1/28/2025 - PREVIOUS INSPECTION NOTES 1. There's material on the roof that's not supposed to be there at front Entrance. 2. Outlet in Hall between bedrooms next to hall bath needs to be GFCI, within 6' of sink. NEC 210.8 3. Power coming from ceiling in A/C closet needs to be sealed.R402.4.1.1 4. Please post Termite Certificate on Breaker Panel.FBC [A] 105.11
BLD - BUILDING FINAL 01/28/2025 Disapproved - NO FEE HCAMACHO
Note: 1. There's material on the roof that's not supposed to be there at front Entrance. 2. Outlet in Hall between bedrooms next to hall bath needs to be GFCI, within 6' of sink. NEC 210.8 3. Power coming from ceiling in A/C closet needs to be sealed.R402.4.1.1 4. Please post Termite Certificate on Breaker Panel.FBC [A] 105.11
U -UTILITY RESIDENTIAL FINAL 01/21/2025 FINAL APPROVED LFITZGERALD
Note: 1/15/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 1/15/2025 11:30:04 AM *** locatevsewervclean iut at tap
U -UTILITY RESIDENTIAL FINAL 01/15/2025 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/15/2025 11:30:04 AM *** locatevsewervclean iut at tap
BLD - BUILDING FINAL 01/15/2025 CANCELLED BY APPLICANT HCAMACHO
Note: Cancelled by applicant
U-CROSS CONNECTION 01/15/2025 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/15/2025 11:29:39 AM *** no irrigation-no cross connectin
ROW - FINAL APRON (AFTER POUR) 01/14/2025 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/14/2025 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 01/14/2025 APPROVED EMADISON
ROW - STORMWATER FINAL 01/14/2025 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/27/2024 CANCELLED BY APPLICANT EMADISON
Note: 10/21/2024 - PREVIOUS INSPECTION NOTES **10/21/24 Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ ** Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) (NOTE YOUR LEFT REAR WILL ALL FLOW ONTO THE ADJACENT PROPERTY ) ** LEFT SIDE NEED THE 10' OFFSET SHOTS ALL THE WAY TO THE REAR PROPERTY LINE
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/21/2024 Disapproved - NO FEE EMADISON
Note: **10/21/24 Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ ** Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) (NOTE YOUR LEFT REAR WILL ALL FLOW ONTO THE ADJACENT PROPERTY ) ** LEFT SIDE NEED THE 10' OFFSET SHOTS ALL THE WAY TO THE REAR PROPERTY LINE
ROW- PRE-APRON (PRE-POUR) 09/13/2024 APPROVED - AS NOTED EMADISON
Note: ** 09/13/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ____________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES ** 09/10/24 RISERFOR SWERE CLEAN OUT IS STILL SET LOWER THAN YOUR FORMS ** NEED TO RE-DIG FOOTERS AT CUVERT ENDS ** NEED TO BACK FILL AROUND FORM BOARDS TO CONTAIN CONCRETE WITHIN POUR AREA ** NEED TO REMOVE FORM BOARD FROM EDGE OF ROADWAY AND PUT FACEBOARD ACROSS EDGE OF ROAD _________________________________________________________________________________________________________________ 9/5/2024 - PREVIOUS INSPECTION NOTES ** 09/05/24 SEWER CLEAN OUT NEEDS A RISER AS IT IS CURRENTLY BELOW FORM BOARDS IN POUR AREA
ROW- PRE-APRON (PRE-POUR) 09/10/2024 Disapproved - NO FEE EMADISON
Note: ** 09/10/24 RISERFOR SWERE CLEAN OUT IS STILL SET LOWER THAN YOUR FORMS ** NEED TO RE-DIG FOOTERS AT CUVERT ENDS ** NEED TO BACK FILL AROUND FORM BOARDS TO CONTAIN CONCRETE WITHIN POUR AREA ** NEED TO REMOVE FORM BOARD FROM EDGE OF ROADWAY AND PUT FACEBOARD ACROSS EDGE OF ROAD _________________________________________________________________________________________________________________ 9/5/2024 - PREVIOUS INSPECTION NOTES ** 09/05/24 SEWER CLEAN OUT NEEDS A RISER AS IT IS CURRENTLY BELOW FORM BOARDS IN POUR AREA
ROW- PRE-APRON (PRE-POUR) 09/05/2024 Disapproved - NO FEE EMADISON
Note: ** 09/05/24 SEWER CLEAN OUT NEEDS A RISER AS IT IS CURRENTLY BELOW FORM BOARDS IN POUR AREA
ELECTRIC - EARLY POWER 08/20/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/20/2024 9:51:12 AM *** Authorize release of email to FPL. Please remove portalet from swale area, before next inspection. FBC 3303.5 SWALE CLEAR Sec. 24-162 (c) of the Land Development Code ........Constructi.on and protection of swales—Roadside
GRAVITY SEWER TEST 08/12/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 08/12/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 07/08/2024 APPROVED JWALKER
ALL ROUGH 07/01/2024 APPROVED JSTEWART
Note: 6/28/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/28/2024 9:19:10 AM *** the following still needs cerrection 1. Please install mechanical fasteners at exhaust duct connection at fan assembly (was sealed as previously noted)FBC M1601.4.1 Joints, seams and connections 2. Please seal broken seal at exhaust duct roof penetration Master bath. 6/26/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 6/26/2024 9:59:15 AM *** Previous note no rectified....2. UFB wiring has not been installed at the kitchen island. (conduit under slab needs to be relocated into wall line, currently is in the middle of refridgerator floor space) In addition....1. Please install mechanical fasteners at exhaust duct connection at fan assembly (was sealed as previously noted)FBC M1601.4.1 Joints, seams and connections 2. Please seal broken seal at exhaust duct roof penetration Master bath. 6/12/2024 - PREVIOUS INSPECTION NOTES 6/12/24 1. Multiple nail plates needed through out the building at the eletrical wiring. 2. UFB wiring has not been installed at the kitchen island. 3. Rear slider has not been installed. 4. Phase out the 2 wire in the electrical sub panel. 5. Seal all flex duct where they connect to the distribution boxes. 6/10/2024 - PREVIOUS INSPECTION NOTES No electrical wiring installed. HVAC just getting started. Inspeciton stopped, Job site is not ready. Please walk your job site prior to scheduling for inspections.
ALL ROUGH 06/28/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 6/28/2024 9:19:10 AM *** the following still needs cerrection 1. Please install mechanical fasteners at exhaust duct connection at fan assembly (was sealed as previously noted)FBC M1601.4.1 Joints, seams and connections 2. Please seal broken seal at exhaust duct roof penetration Master bath. 6/26/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 6/26/2024 9:59:15 AM *** Previous note no rectified....2. UFB wiring has not been installed at the kitchen island. (conduit under slab needs to be relocated into wall line, currently is in the middle of refridgerator floor space) In addition....1. Please install mechanical fasteners at exhaust duct connection at fan assembly (was sealed as previously noted)FBC M1601.4.1 Joints, seams and connections 2. Please seal broken seal at exhaust duct roof penetration Master bath. 6/12/2024 - PREVIOUS INSPECTION NOTES 6/12/24 1. Multiple nail plates needed through out the building at the eletrical wiring. 2. UFB wiring has not been installed at the kitchen island. 3. Rear slider has not been installed. 4. Phase out the 2 wire in the electrical sub panel. 5. Seal all flex duct where they connect to the distribution boxes. 6/10/2024 - PREVIOUS INSPECTION NOTES No electrical wiring installed. HVAC just getting started. Inspeciton stopped, Job site is not ready. Please walk your job site prior to scheduling for inspections.
LATH/BRICK/ WATER BARRIER 06/28/2024 APPROVED LMILLER
Note: 6/13/2024 - PREVIOUS INSPECTION NOTES
ALL ROUGH 06/26/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 6/26/2024 9:59:15 AM *** Previous note no rectified....2. UFB wiring has not been installed at the kitchen island. (conduit under slab needs to be relocated into wall line, currently is in the middle of refridgerator floor space) In addition....1. Please install mechanical fasteners at exhaust duct connection at fan assembly (was sealed as previously noted)FBC M1601.4.1 Joints, seams and connections 2. Please seal broken seal at exhaust duct roof penetration Master bath. 6/12/2024 - PREVIOUS INSPECTION NOTES 6/12/24 1. Multiple nail plates needed through out the building at the eletrical wiring. 2. UFB wiring has not been installed at the kitchen island. 3. Rear slider has not been installed. 4. Phase out the 2 wire in the electrical sub panel. 5. Seal all flex duct where they connect to the distribution boxes. 6/10/2024 - PREVIOUS INSPECTION NOTES No electrical wiring installed. HVAC just getting started. Inspeciton stopped, Job site is not ready. Please walk your job site prior to scheduling for inspections.
LATH/BRICK/ WATER BARRIER 06/13/2024 CANCELLED BY APPLICANT JWALKER
ALL ROUGH 06/12/2024 Disapproved -FEE REQUIRED JWALKER
Note: 6/12/24 1. Multiple nail plates needed through out the building at the eletrical wiring. 2. UFB wiring has not been installed at the kitchen island. 3. Rear slider has not been installed. 4. Phase out the 2 wire in the electrical sub panel. 5. Seal all flex duct where they connect to the distribution boxes. 6/10/2024 - PREVIOUS INSPECTION NOTES No electrical wiring installed. HVAC just getting started. Inspeciton stopped, Job site is not ready. Please walk your job site prior to scheduling for inspections.
ALL ROUGH 06/10/2024 Disapproved -FEE REQUIRED JWALKER
Note: No electrical wiring installed. HVAC just getting started. Inspeciton stopped, Job site is not ready. Please walk your job site prior to scheduling for inspections.
ROOF VALLEY & METAL 06/06/2024 APPROVED JWALKER
WALL SHEATHING 05/30/2024 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/30/2024 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 05/29/2024 APPROVED TBAKER
MONOLITHIC SLAB 05/13/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 05/08/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/07/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 03/28/2024 APPROVED CBOWERMASTER
WILDLIFE CHECK - ENVIRONMENTAL 02/08/2024 APPROVED DRODRIGUEZ

Review History

Department Status Date In Date Out
MECH COMPLETE 06/05/2024 06/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/29/2024 05/29/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/29/2024 05/29/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 05/03/2024 05/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 03/05/2024 03/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 03/05/2024 03/05/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 03/05/2024 03/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/05/2024 03/06/2024
Note: Released By: JPI
BADMIN COMPLETE 03/05/2024 03/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 03/05/2024 03/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 03/05/2024 03/12/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
SWALE COMPLETE 02/06/2024 03/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLENV COMPLETE 02/06/2024 02/08/2024
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 02/08/24 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
BADMIN HOLD 02/05/2024 02/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) (YOU ARE MISSING (D) THE STAMP FROM THE ENGINEER OF RECORD. YOU CANNOT SUBMIT A LETTER. THE APPROVAL STAMP NEEDS TO BE ON THE FIRST PAGE OF THE TRUSS PACKET OR TRUSS LAYOUT.)
BLD HOLD 02/05/2024 02/09/2024
Note: Held By: JPI 1. City of Palm Coast Color and Material Sheet (form) appears OMITTED from submission. FBC 105 2. Provide specific product numbers including current revisions (i.e. 11473.# R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 3. Provide roof underlayment and shingle revision number on Florida Product Approval Specification Sheet that corresponds with the Roofing Worksheet; underlayment Florida Product Approval number on Roofing Worksheet does not include revision number. 107.2.4 4. Provide Florida Product Approval number for shutters. 107.2.4 5. Architectural drawings do NOT have a signed seal by the Architect of Record/Engineer of Record. 6. Reference to 2023 Florida Residential Code, Section R302.3. 7. Provide elevation (height) for Second Floor on ALL Elevations. 107.3.5 8. Provide pitch/slopes of ALL roofs on the Elevations.. R802
CUSVC COMPLETE 02/05/2024 02/08/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 02/05/2024 02/08/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electric load calcs are done by a different contractor thats listed on your permit. 4. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 02/05/2024 02/06/2024
LOCATE COMPLETE 02/05/2024 02/06/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 02/05/2024 02/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to be Daytona Beach 2. Square footage on the Energy calcs does not match the house plans
SW1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 02/05/2024 02/06/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Survey/ site plan:missing square footage of lot, missing Map Panel number should be 0129E. Missing walkway, materials and width also. Landscape plan: provide the correct plan as the plan provided is for a different home. Please make sure the trees are within the property lines for credit. AC needs a minimum of 7 gallons Elevation is missing the roof pitch.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/04/2025
REINSPECTION RESIDENTIAL ¤40.00 02/04/2025
REINSPECTION RESIDENTIAL ¤40.00 02/04/2025
REINSPECTION RESIDENTIAL ¤40.00 02/04/2025
CONTRACTOR CHANGE ¤20.00 02/04/2025
REINSPECTION FEE ¤40.00 02/04/2025
SURCHARGE FS 533.721 ¤6.17 03/12/2024
SURCHARGE - FS 468.631 ¤9.25 03/12/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/12/2024
SW ENG INSPECTION 80 ¤80.00 03/12/2024
SW ENG PRE APRON ¤30.00 03/12/2024
SW ENG - REVIEW 20 ¤20.00 03/12/2024
SW ENG RES REVIEW 200 ¤200.00 03/12/2024
SEWER CREDIT (¤850.00) 03/12/2024
SEWER INSPECTION ¤25.00 03/12/2024
SEWER CAPITAL FACILITY ¤5,441.03 03/12/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 03/12/2024
SITE PLAN 30 ¤30.00 03/12/2024
FC IMPACT FEE EMS ¤62.00 03/12/2024
IMPACT FEE FIRE ¤428.09 03/12/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/12/2024
FC IMPACT FEE LIBRARY ¤268.00 03/12/2024
IMPACT FEE PARKS ¤1,800.99 03/12/2024
IMPACT FEE SCHOOL ¤5,450.00 03/12/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 03/12/2024
WATER -IRRIGATION INSPECTION ¤25.00 03/12/2024
CONNECTION FEES ¤1,187.26 03/12/2024
CONTRACTOR CHANGE ¤20.00 03/12/2024
CONTRACTOR CHANGE ¤20.00 03/12/2024
WATER- TURN ON ¤25.00 03/12/2024
ADJUSTMENT 50% (¤616.87) 03/12/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/12/2024
INSPECTION - RESIDENTIAL ¤937.75 03/12/2024
PLAN REVIEW - RESIDENTIAL ¤265.98 03/12/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,201.66