Permit #2024020166

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00720-0130
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00720
Subdivision: 2211 - SECTION 59-SEMINOLE PARK
Job Phone: 386-283-2035
Location Address: 9 SLATINGTON PL
Type: DU - DUPLEX
Issue Date: 03/13/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: FLORIDA'S BEST BUILDERS INC

Address

101 PALM HARBOR PKWY UNIT 145

PALM COAST, FL 32137

Lot: 0130
Contracted Stated Job Value: ¤350,000.00
Job Description: Duplex
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 02/03/2025 APPROVED FSLADISH
Note: 2/3/25 CORRECTION MADE. PAVERS GLUED DOWN. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 1/27/2025 - PREVIOUS INSPECTION NOTES 1/27/25 UPON WALKING DRIVEWAY AS PREVIOUSLY NOTED ON THE LEFT SIDE OF DRIVEWAY APRON AT EDGE OF PAVEMENT THER ARE LOOSE PAVERS. THESE WILL NEED TO BE REGLUED AND SET. YOU ARE ALSO REQUIRED TO SEED AND STRAW BARE AREA ON THE REAR PROPERTY LINE/VACANT BEFORE ROW FINAL WILL PASS.
U-CROSS CONNECTION 01/28/2025 APPROVED BWRIGHT
BLD - BUILDING FINAL 01/27/2025 FINAL APPROVED BTAYLOR
ROW - FINAL APRON (AFTER POUR) 01/27/2025 APPROVED - AS NOTED FSLADISH
Note: 1/27/25 UPON WALKING DRIVEWAY AS PREVIOUSLY NOTED ON THE LEFT SIDE OF DRIVEWAY APRON AT EDGE OF PAVEMENT THER ARE LOOSE PAVERS. THESE WILL NEED TO BE REGLUED AND SET BEFORE ROW FINAL WILL PASS. NO OTHER CHIPPED CRACKED OR BROKEN PAVERS OBSERVED AT THE TIME OF THIS INSPECTION. APPROVING THIS AS NOTED THAT CORRECTIONS ARE REQUIRED BEFORE ROW FINAL PASSAGE. INSPECTORS NOTE. LEFT SIDE DRIVEWAY APRON PAVERS, A FEW ARE LOOSE AT EDGE OF ROAD AS OF TODAY 1/22
U -UTILITY RESIDENTIAL FINAL 01/27/2025 FINAL APPROVED BWRIGHT
ROW - FINAL INSPECTION 01/27/2025 Disapproved - NO FEE FSLADISH
Note: 1/27/25 UPON WALKING DRIVEWAY AS PREVIOUSLY NOTED ON THE LEFT SIDE OF DRIVEWAY APRON AT EDGE OF PAVEMENT THER ARE LOOSE PAVERS. THESE WILL NEED TO BE REGLUED AND SET. YOU ARE ALSO REQUIRED TO SEED AND STRAW BARE AREA ON THE REAR PROPERTY LINE/VACANT BEFORE ROW FINAL WILL PASS.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/22/2025 APPROVED FSLADISH
Note: 1/22/25 TREES MOVED. ELEVATIONS NOW SHOW POSITIVE REAR TO FRONT SWALE FLOW. DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED __________________________________________________________________________________________________________________________ 12/12/2024 - PREVIOUS INSPECTION NOTES 12/12/24 AS PREVIOUSLY INDICATED AND CONFIRMED IN THE FIELD, THERE ARE INDEED HIGH AREAS THAT NEED TO BE LOWERED TO ALLOW DRAINGE TO FLOW FROM REAR TO FRONT SWALE. YOU WILL ALSO NEED TO RELOCATE THE TWO TREES IN THE REAR BACK OUT OF THE DRAINAGE CONVETANCE. THEY WILL NOT ALLOW POSITIVE DRAINAGE. BOTH AREAS OF CORRECTION ARE OUTLINED IN WHITE PAINT. Inspector Notes from Inspection 9463 12/12/24 YOU HAVE TWO HIGH SPOTS BY THE REAR CORNERS SHOWING ON YOUR FINAL SURVEY. ON THE LEFT YOU ARE SHOWING 26.30 TO A 26.60 BACK TO 26.40. ON THE RIGHT YOU ARE SHOWING 26.40 TO A 26.70 TO A 26.20. I WILL SEE IF THIS IS THE CASE ON THE FIELD SURVEY. APPROVING THIS INSPECTION AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/22/2025 APPROVED FSLADISH
Note: 1/22/25 ELEVATION CORRECTIONS MADE AS OF THIS FINAL SURVEY. _______________________________________________________________________________________________________________________ 1/10/2025 - PREVIOUS INSPECTION NOTES 1/10/25 YOUR ELEVATIONS COMING AROUND THE LEFT SIDE FROM THE REAR AT 26.25 UP TO 26.35 TO A 26.10 AT STRUCTURE CORNER AT START OF INSIDE DRAINAGE CONVEYANCE THEN UPHILL TO A 26.35 TO A 26.30 TO A 26.10 WHICH IS FLAT FROM THE SHOT 60FT BACK. THIS WILL NOT ALLOW DRAINAGE TO HAVE POSITIVE FLOW. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Sec.300.01 C2 The tolerance on individual shots along the as-built flow line of the swale (depressions orhigh spots) is plus or minus 0.10 feet.Sec.300.01 C2 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 12/26/2024 - PREVIOUS INSPECTION NOTES 12/26/24=THE CULVERT PIPE IS OUT OF TOLERANCE ON BOTH ENDS. PLEASE REFER TO THE DETAILED SWALE PLAN FOR REFERENCE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/10/2025 Disapproved - NO FEE FSLADISH
Note: 1/10/25 YOUR ELEVATIONS COMING AROUND THE LEFT SIDE FROM THE REAR AT 26.25 UP TO 26.35 TO A 26.10 AT STRUCTURE CORNER AT START OF INSIDE DRAINAGE CONVEYANCE THEN UPHILL TO A 26.35 TO A 26.30 TO A 26.10 WHICH IS FLAT FROM THE SHOT 60FT BACK. THIS WILL NOT ALLOW DRAINAGE TO HAVE POSITIVE FLOW. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Sec.300.01 C2 The tolerance on individual shots along the as-built flow line of the swale (depressions orhigh spots) is plus or minus 0.10 feet.Sec.300.01 C2 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 12/26/2024 - PREVIOUS INSPECTION NOTES 12/26/24=THE CULVERT PIPE IS OUT OF TOLERANCE ON BOTH ENDS. PLEASE REFER TO THE DETAILED SWALE PLAN FOR REFERENCE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/26/2024 Disapproved - NO FEE GBERTOLA
Note: 12/26/24=THE CULVERT PIPE IS OUT OF TOLERANCE ON BOTH ENDS. PLEASE REFER TO THE DETAILED SWALE PLAN FOR REFERENCE.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/12/2024 Disapproved - NO FEE FSLADISH
Note: 12/12/24 AS PREVIOUSLY INDICATED AND CONFIRMED IN THE FIELD, THERE ARE INDEED HIGH AREAS THAT NEED TO BE LOWERED TO ALLOW DRAINGE TO FLOW FROM REAR TO FRONT SWALE. YOU WILL ALSO NEED TO RELOCATE THE TWO TREES IN THE REAR BACK OUT OF THE DRAINAGE CONVETANCE. THEY WILL NOT ALLOW POSITIVE DRAINAGE. BOTH AREAS OF CORRECTION ARE OUTLINED IN WHITE PAINT. Inspector Notes from Inspection 9463 12/12/24 YOU HAVE TWO HIGH SPOTS BY THE REAR CORNERS SHOWING ON YOUR FINAL SURVEY. ON THE LEFT YOU ARE SHOWING 26.30 TO A 26.60 BACK TO 26.40. ON THE RIGHT YOU ARE SHOWING 26.40 TO A 26.70 TO A 26.20. I WILL SEE IF THIS IS THE CASE ON THE FIELD SURVEY. APPROVING THIS INSPECTION AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/12/2024 APPROVED - AS NOTED FSLADISH
Note: 12/12/24 YOU HAVE TWO HIGH SPOTS BY THE REAR CORNERS SHOWING ON YOUR FINAL SURVEY. ON THE LEFT YOU ARE SHOWING 26.30 TO A 26.60 BACK TO 26.40. ON THE RIGHT YOU ARE SHOWING 26.40 TO A 26.70 TO A 26.20. I WILL SEE IF THIS IS THE CASE ON THE FIELD SURVEY. APPROVING THIS INSPECTION AS NOTED.
ROW- PRE-APRON (PRE-POUR) 11/08/2024 APPROVED FSLADISH
Note: 11/8/24 YOU ARE APPROVED TO LAY PAVERS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9271 11/4/24 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 11/04/2024 APPROVED - AS NOTED FSLADISH
Note: 11/4/24 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 11/04/2024 PARTIALLY APPROVED FSLADISH
Note: 11/4/24 PIPE ELEVATION GOOD. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ELECTRIC - EARLY POWER 09/19/2024 APPROVED - AS NOTED BTAYLOR
Note: 9/18/2024 - PREVIOUS INSPECTION NOTES 9-18-24 1. House locked. 9-19-24 1. Emailed FPL at 1:10.
ELECTRIC - EARLY POWER 09/18/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 9-18-24 1. House locked.
GRAVITY SEWER TEST 09/03/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BEFORE SLAB INSPECTION
SEWER TIE IN 09/03/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BEFORE SLAB INSPECTION
PEP TANK INSTALLATION REQUEST 08/20/2024 APPROVED CBOWERMASTER
INSULATION 08/07/2024 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 08/07/2024 APPROVED BTAYLOR
Note: 7/31/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 7-30-24 1. Need two forms of connection for bathroom exhaust fans. 2. Side Aelectrical panel needs to be dropped down to 6'. 3. Island outlets on ends need to be moved down. 4. Roof penatrations need their covers and goose necks. 7-31-24 1. Nothing from above has been resolved.
LATH/BRICK/ WATER BARRIER 07/31/2024 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2420 7-30-24 1. Need two forms of connection for bathroom exhaust fans. 2. Side Aelectrical panel needs to be dropped down to 6'. 3. Island outlets on ends need to be moved down. 4. Roof penatrations need their covers and goose necks. 7-31-24 1. Nothing from above has been resolved.
ALL ROUGH 07/30/2024 APPROVED - AS NOTED BTAYLOR
Note: 7-30-24 1. Need two forms of connection for bathroom exhaust fans. 2. Side Aelectrical panel needs to be dropped down to 6'. 3. Island outlets on ends need to be moved down. 4. Roof penatrations need their covers and goose necks.
FIREWALL FINAL 07/16/2024 APPROVED BTAYLOR
FIREWALL DRYWALL NAILING 07/10/2024 APPROVED RSIMS
FIREWALL FRAMING 07/01/2024 APPROVED BTAYLOR
ROOF VALLEY & METAL 06/26/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/24/2024 APPROVED BTAYLOR
Note: 6/21/2024 - PREVIOUS INSPECTION NOTES 6/20/2024 - PREVIOUS INSPECTION NOTES 6-20-24 1. Overframing needs to be strapped at both ends of rafters. 2. Missing engineering on truss T17. Circled in plans. 6-21-24 1. Overframing needs to be strapped at both ends of rafters.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/21/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 6/20/2024 - PREVIOUS INSPECTION NOTES 6-20-24 1. Overframing needs to be strapped at both ends of rafters. 2. Missing engineering on truss T17. Circled in plans. 6-21-24 1. Overframing needs to be strapped at both ends of rafters.
WALL SHEATHING 06/20/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2024 Disapproved - NO FEE BTAYLOR
Note: 6-20-24 1. Overframing needs to be strapped at both ends of rafters. 2. Missing engineering on truss T17. Circled in plans.
TIE BEAM / LINTEL 05/24/2024 APPROVED AGAETANO
FOUND SURVEY APPROVED (OFFICE) 05/22/2024 APPROVED TBAKER
MONOLITHIC SLAB 05/14/2024 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 05/09/2024 APPROVED - AS NOTED MGIBSON
Note: 3307.1 PROTECTION OF PROPERTY, NEED SILT FENCE IN PLACE BEFORE SLAB INSPECTION
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/02/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 03/22/2024 APPROVED BVITALE

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2024 09/05/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/04/2024 09/04/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 09/03/2024 09/03/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide driveway apron width at edge of pavement COPC Techinical Manual, Section 300.01 (A)(1)(C)(1)
ZON HOLD 09/03/2024 09/03/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit original Right of Way Utilization Agreement for Paver Driveway.
ENGIN1 COMPLETE 05/21/2024 05/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/21/2024 05/21/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 05/07/2024 05/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/29/2024 05/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 04/24/2024 04/29/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter needs to include the density test reports.
BLD COMPLETE 04/03/2024 04/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 03/28/2024 04/02/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor
MECH COMPLETE 03/05/2024 03/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 03/03/2024 03/04/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs from current code cycle (Third Request)
MECH HOLD 02/20/2024 02/26/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy calcs from 2023 code cycle ( Second Request)
ZON COMPLETE 02/20/2024 02/20/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/20/2024 02/22/2024
Note: Released By: JPI
BADMIN COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 02/06/2024 03/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 02/05/2024 02/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) (YOU ARE MISSING (B) THE TRUSS LAYOUT AND (D) THE STAMP FROM THE ENGINEER OF RECORD. YOU CANNOT SUBMIT A LETTER. THE APPROVAL STAMP NEEDS TO BE ON THE FIRST PAGE OF THE TRUSS PACKET OR TRUSS LAYOUT.)
BLD HOLD 02/05/2024 02/09/2024
Note: Held By: JPI 1. Provide appropriate revision numbers (i.e. R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 107.2.4 2. Provide specific product numbers (i.e. 11473.# R6) for ALL products listed on Product Approval Specification Sheet; several have been OMITTED. 107.2.4 3. Provide correct Florida Product Approval (FPA) number for ALL products listed on Product Approval Specification Sheet; composite lumber number appears incorrect. 5. Florida Product Approval number for Roofing Underlayment does NOT match the one indicated on the Roofing Worksheet. 107.2.4 6. Provide roof ventilation calculations for required number and size of roof vents; identify size on plans and elevations. 107.2.4 7. Provide/indicate what elevation lines represent on ALL elevations; dimensions have been provided, however nothing indicates what they are dimensioning to. 107.3.5 8. Identify U.L. number for “upper tenant firewall detail” drawing on Sht. 2. Chapter 7 9. Provide U.L. Listing from ULC Online Directories for UL338; similar to U905 provided on Sht. 3. Chapter 7 10. Detail 4 on Sht. 3 identifies as a firewall detail but no U.L. Listing is provided. Chapter 7 11. Under “General” on Sht. 4 states, “all connectors shown in these drawings can be substituted with other suitable connectors”; substitutions shall have Florida Product Approval numbers. 107.2.4 12. “Common Wire To Gun Nail Conversion” table on Sht. 8 is difficult to read; numbers have been placed over numbers. 107.3.5
CUSVC COMPLETE 02/05/2024 02/08/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 02/05/2024 02/08/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in laundry and garage need to be GFCI protected. NEC 2020 210.8
ENGIN1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 02/05/2024 02/06/2024
LOCATE COMPLETE 02/05/2024 02/06/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 02/05/2024 02/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy calcs from 2023 code cycle
SW1 COMPLETE 02/05/2024 02/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 02/05/2024 02/06/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM This lot has two flood panel numbers both must be listed on survey/site plan Must have a minimum 16ft driveway for each one car garage. Total should be a minimum 32ft in width

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/05/2024
RECORDING FEE REIMBURSE DOC ¤44.00 09/03/2024
REINSPECTION RESIDENTIAL ¤40.00 06/21/2024
WATER- TURN ON ¤50.00 03/13/2024
ADJUSTMENT 50% (¤821.61) 03/13/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/13/2024
INSPECTION - RESIDENTIAL ¤1,256.75 03/13/2024
PLAN REVIEW - RESIDENTIAL ¤356.46 03/13/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 03/13/2024
WATER -IRRIGATION INSPECTION ¤50.00 03/13/2024
SURCHARGE FS 533.721 ¤8.22 03/13/2024
SURCHARGE - FS 468.631 ¤12.32 03/13/2024
SW ENG - FOUNDATION SURVEY ¤20.00 03/13/2024
SW ENG INSPECTION 80 ¤80.00 03/13/2024
SW ENG PRE APRON ¤30.00 03/13/2024
SW ENG - REVIEW 20 ¤20.00 03/13/2024
SW ENG RES REVIEW 200 ¤200.00 03/13/2024
SEWER INSPECTION ¤25.00 03/13/2024
SEWER CAPITAL FACILITY ¤10,882.06 03/13/2024
WATER CAPITAL FACILITY FEE ¤7,989.02 03/13/2024
SITE PLAN 30 ¤30.00 03/13/2024
CONNECTION FEES ¤2,374.52 03/13/2024
FC IMPACT FEE EMS ¤124.00 03/13/2024
IMPACT FEE FIRE ¤856.18 03/13/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 03/13/2024
FC IMPACT FEE LIBRARY ¤536.00 03/13/2024
IMPACT FEE PARKS ¤3,600.18 03/13/2024
IMPACT FEE SCHOOL ¤10,900.00 03/13/2024
Fees Total Due: ¤0.00 Total Paid: ¤42,059.10