I want to search for...
Permit #2024020343
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7024-00170-0280 |
| CONDITIONED SPACE: 2000 sqft |
| GARAGE: 700 sqft |
| OPENED PORCH (WITH ROOF) : 197 sqft |
| OPENED PORCH (WITH ROOF) : 144 sqft |
| Total Square Footage: 3041 sqft |
| Block: 00170 |
| Subdivision: 2167 - SECTION 24-PINE GROVE |
| Job Phone: 912-258-2201 |
| Location Address: 26 PRINCE KAAREL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| NOC: Unknown |
| Applicant name: JAMES FUCETOLA III |
| Owner: PALM COAST COMMUNITIES LLC |
|
Address PO BOX 22547 ST SIMONS ISLAND, GA 31522 |
| Lot: 0280 |
| Contracted Stated Job Value: ¤260,000.00 |
| Job Description: Single Family Home |
| Type: CN |
Contractor
PALM COAST COMMUNITIES LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 22547 PALM COAST, FL 32164 |
CBC1262878 (Exp: 08/31/2026) | 321-501-4617 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
Inspection History
| Type | Request Date | Result | Inspector |
| FOUND SURVEY APPROVED (OFFICE) | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/26/2024 | 02/29/2024 |
| Note: Released By: JPI | |||
| ELEC | COMPLETE | 02/20/2024 | 02/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/20/2024 | 02/22/2024 |
| Note: Held By: JPI ½ hour not approved palm coast resubmittal 1. Repeating comment. Provide appropriate revision numbers (i.e. R6) for ALL products listed on Product Approval Specification Sheet; 107.2.4 2. Repeating comment. FPA for roofing underlayment appears incorrect. 107.2.4 3. Repeating comment. Include ALL wood connectors and anchors’ Florida Product Approval numbers on Product Approval Specification Sheet that are being used on the project; use additional sheet if necessary. 107.2.4 4. Repeating comment. Windows Mullion Florida Product Approval Number has been OMITTED from the Florida Product Approval Specification Sheet. 107.2.4 5. Repeating comment. Front entry door side lite FPAs appear to be OMITTED from the Florida Product Approval Specification Sheet.107.2.4 6. Repeating comment. Roofing Products Off-ridge Vent has been OMITTED from the Florida Product Approval Specification Sheet. 107.2.4 | |||
| MECH | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/08/2024 | 02/13/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need shop drawing approval stamp on truss layout or truss package. | |||
| BLD | HOLD | 02/08/2024 | 02/13/2024 |
| Note: Held By: JPI 1. Provide appropriate revision numbers (i.e. R6) for ALL products listed on Product Approval Specification Sheet; 107.2.4 2. FPA for roofing underlayment appears incorrect. 107.2.4 3. Include ALL wood connectors and anchors’ Florida Product Approval numbers on Product Approval Specification Sheet that are being used on the project; use additional sheet if necessary. 107.2.4 4. Windows Mullion Florida Product Approval Number has been OMITTED from the Florida Product Approval Specification Sheet. 107.2.4 5. Front entry door side lite FPAs appear to be OMITTED from the Florida Product Approval Specification Sheet.107.2.4 6. Roofing Products Off-ridge Vent has been OMITTED from the Florida Product Approval Specification Sheet. 107.2.4 7. Architectural and electrical drawings are NOT signed and sealed by a licensed professional Architect or Engineer. 107.3.5 8. Notes (call-outs) on the Elevations, Sht. A-2 do NOT appear to match those on the Floor Plan, Sht. A-1 (i.e. 12” x 12” conc. Column…..12” x 12” cmu column); ALL drawing shall be coordinated and correspond with one another. 107.3.5 9. Wall Section provided does not represent the construction and materials of this specific project; ALL drawings shall be coordinated and correspond with one another. 107.3.5 10. CMU Sill Attachment Detail on Sht. A-3 does NOT appear to correspond with the Elevations, Sht. A-2. 107.3.5 | |||
| CUSVC | COMPLETE | 02/08/2024 | 02/12/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/08/2024 | 02/09/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85 | |||
| ENGIN1 | COMPLETE | 02/08/2024 | 02/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/08/2024 | 02/14/2024 |
| LOCATE | COMPLETE | 02/08/2024 | 02/09/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/08/2024 | 02/14/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| SW1 | COMPLETE | 02/08/2024 | 02/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/08/2024 | 02/08/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/08/2024 | 03/26/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | |
| ADJUSTMENT 50% | (¤719.24) | |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | |
| INSPECTION - RESIDENTIAL | ¤1,097.25 | |
| PLAN REVIEW - RESIDENTIAL | ¤311.22 | |
| CONNECTION FEES | ¤1,187.26 | |
| FC IMPACT FEE EMS | ¤62.00 | |
| IMPACT FEE FIRE | ¤428.09 | |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | |
| FC IMPACT FEE LIBRARY | ¤268.00 | |
| IMPACT FEE PARKS | ¤1,800.99 | |
| IMPACT FEE SCHOOL | ¤5,450.00 | |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | |
| WATER -IRRIGATION INSPECTION | ¤25.00 | |
| SURCHARGE FS 533.721 | ¤7.19 | |
| SURCHARGE - FS 468.631 | ¤10.79 | |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | |
| SW ENG INSPECTION 80 | ¤80.00 | |
| SW ENG PRE APRON | ¤30.00 | |
| SW ENG - REVIEW 20 | ¤20.00 | |
| SW ENG RES REVIEW 200 | ¤200.00 | |
| SEWER CREDIT | (¤1,466.00) | |
| SEWER INSPECTION | ¤25.00 | |
| SEWER CAPITAL FACILITY | ¤5,441.03 | |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | |
| SITE PLAN 30 | ¤30.00 | |
| Fees | Total Due: ¤20,438.09 | Total Paid: ¤0.00 |