I want to search for...

Permit #2024020882

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00230-0060
GARAGE: 455 sqft
CONDITIONED SPACE: 1721 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
Total Square Footage: 2459 sqft
Block: 00230
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 631-929-5500
Location Address: 3 POTOMAC DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/15/2024
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: ANDREW BLANCO AND DIANA M BARRY

Address

45 POPLAR DRIVE

PALM COAST, FL 32164

Lot: 0060
Contracted Stated Job Value: ¤205,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/16/2024 FINAL APPROVED KSANDOE
Note: 8/15/2024 - PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 08/15/2024 CANCELLED BY APPLICANT KSANDOE
ROW - FINAL APRON (AFTER POUR) 08/15/2024 APPROVED FSLADISH
Note: 8/15/24 PIPE ELVATION IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. Inspector Notes from Inspection 9465 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B)
ROW - STORMWATER FINAL 08/15/2024 APPROVED - AS NOTED FSLADISH
Note: 8/15/24 At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B)
U -UTILITY RESIDENTIAL FINAL 08/15/2024 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:34:44 PM *** no irr-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 08/12/2024 APPROVED - AS NOTED FSLADISH
Note: 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B)
ELECTRIC - EARLY POWER 08/07/2024 APPROVED RMARTIN
Note: Inspector Notes from Inspection 2200 5/30/24: FPL emailed at @ 13:45. Approved for TUG
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/01/2024 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/01/2024 Disapproved - NO FEE TPOLACEK
Note: 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B)
GRAVITY SEWER TEST 07/15/2024 APPROVED MGIBSON
Note: 4/25/2024 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET
SEWER TIE IN 07/15/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 06/24/2024 APPROVED CBOWERMASTER
Note: 6/21/2024 7:18:38 AM- PREVIOUS INSPECTION NOTES dumpster
PEP TANK INSTALLATION REQUEST 06/18/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster
INSULATION 06/18/2024 APPROVED KSANDOE
ROW- PRE-APRON (PRE-POUR) 06/18/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ALL ROUGH 06/17/2024 APPROVED KSANDOE
Note: 6/13/2024 - PREVIOUS INSPECTION NOTES 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). Great Room: Right side window is missing an anchor on the left jamb (from inside). 3). Master bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 4). Guest bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 5). Guest bathroom: Slab at bathtub drain needs to be fully repaired with cement to make it equal with finished slab surface. 6). Slab at Kitchen Island needs to be fully repaired with cement to make it equal with finished slab surface.
ALL ROUGH 06/13/2024 Disapproved - NO FEE RSIMS
Note: 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). Great Room: Right side window is missing an anchor on the left jamb (from inside). 3). Master bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 4). Guest bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 5). Guest bathroom: Slab at bathtub drain needs to be fully repaired with cement to make it equal with finished slab surface. 6). Slab at Kitchen Island needs to be fully repaired with cement to make it equal with finished slab surface.
ROOF VALLEY & METAL 06/12/2024 APPROVED KSANDOE
Note: 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: 1). Need a revision for the underlayment (Gecco) that does not match the modified bitumen underlayment submitted on the Roofing Worksheet. 2). Pallets of shingles need to be distributed more evenly so that they do not exceed the PSF rating on the trusses. 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 2nd request. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/10/2024 APPROVED KSANDOE
Note: 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: Previously listed item is not resolved. Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 1). 2-ply trusses A01, A17 and B03 are not connected as required by Manufacturer. Marked in Truss Packet. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
LATH/BRICK/ WATER BARRIER 06/10/2024 CANCELLED BY INSPECTOR KSANDOE
Note: Wall sheathing was not inspected prior to wire lath installation.
LATH/BRICK/ WATER BARRIER 06/10/2024 APPROVED KSANDOE
WALL SHEATHING 06/06/2024 APPROVED FWILLIS
Note: 6/6/24 - ITEM CORRECTED. LATH CAN BE REINSTALLED. 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection 2320 re-scheduled. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/05/2024 Disapproved -FEE REQUIRED RSIMS
Note: 6/5/24: Previously listed item is not resolved. Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 1). 2-ply trusses A01, A17 and B03 are not connected as required by Manufacturer. Marked in Truss Packet. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
WALL SHEATHING 06/05/2024 Disapproved - NO FEE RSIMS
Note: 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection 2320 re-scheduled. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
ROOF VALLEY & METAL 06/05/2024 Disapproved - NO FEE RSIMS
Note: 6/5/24: 1). Need a revision for the underlayment (Gecco) that does not match the modified bitumen underlayment submitted on the Roofing Worksheet. 2). Pallets of shingles need to be distributed more evenly so that they do not exceed the PSF rating on the trusses. 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 2nd request. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
U-CROSS CONNECTION 05/31/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:34:44 PM *** no irr-no cross connection
LATH/BRICK/ WATER BARRIER 05/30/2024 APPROVED - AS NOTED RSIMS
Note: 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved.
ELECTRIC-TUG 05/30/2024 APPROVED - AS NOTED RSIMS
Note: 5/30/24: FPL emailed at @ 13:45. Approved for TUG
TIE BEAM / LINTEL 05/09/2024 APPROVED RSIMS
Note: 5/8/2024 - PREVIOUS INSPECTION NOTES 5/7/2024 - PREVIOUS INSPECTION NOTES 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) 05-08-2024 S-1 Lintel D missing bottom rebar.
TIE BEAM / LINTEL 05/08/2024 Disapproved - NO FEE AGAETANO
Note: 5/7/2024 - PREVIOUS INSPECTION NOTES 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) 05-08-2024 1. S-1 Lintel D missing bottom rebar. 2. Dowel not proper clearance as noted on earlier inspection. 3. Please provide a large readable set of approved drawings for all inspections. Drawings are too blurry to read.
TIE BEAM / LINTEL 05/07/2024 Disapproved -FEE REQUIRED RSIMS
Note: 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides)
TIE BEAM / LINTEL 05/06/2024 Disapproved - NO FEE RSIMS
Note: 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides)
FOUND SURVEY APPROVED (OFFICE) 05/06/2024 APPROVED TBAKER
MONOLITHIC SLAB 04/29/2024 APPROVED BTAYLOR
Note: 4/26/2024 - PREVIOUS INSPECTION NOTES 4/26/24: 1). Drain protective sleeve is not fully through the footer. (Code corrected). 305.3 Pipes through foundation walls. Any pipe that passes through a foundation wall shall be provided with a relieving arch, or a pipe sleeve pipe shall be built into the foundation wall. The sleeve shall be two pipe sizes greater than the pipe passing through the wall.
MONOLITHIC SLAB 04/26/2024 Disapproved - NO FEE RSIMS
Note: 4/26/24: 1). Drain protective sleeve is not fully through the footer. (Code corrected from original result). 305.3 Pipes through foundation walls. Any pipe that passes through a foundation wall shall be provided with a relieving arch, or a pipe sleeve pipe shall be built into the foundation wall. The sleeve shall be two pipe sizes greater than the pipe passing through the wall.
PLUMBING 1ST ROUGH UNDERGROUND 04/25/2024 APPROVED MGIBSON
GRAVITY SEWER TEST 04/25/2024 Disapproved - NO FEE MGIBSON
Note: SEWER NOT RAN YET
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/24/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 04/22/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 06/13/2024 06/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2024 06/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/29/2024 06/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/24/2024 05/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 05/15/2024 05/21/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM Truss Packet needs to be digitally signed and sealed b the engineer of record.
ENGIN1 COMPLETE 05/06/2024 05/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/06/2024 05/06/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 04/22/2024 04/22/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please note for future- 1st submittal - TYPE- Geo Tech Report - FILE NAME - geo tech report 2nd submittal - TYPE - Geo Tech Certification - FILE NAME - geo tech certification
BLD COMPLETE 04/22/2024 04/24/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/19/2024 04/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/17/2024 04/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/16/2024 04/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
BLD COMPLETE 03/20/2024 03/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 03/15/2024 03/18/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD HOLD 03/15/2024 03/19/2024
Note: Held By: JPI 1. The provided product approvals include documentation from the 2020 Code cycle. Please remove from the product approvals. FL 16918-R3 notes 2020 Code version. 107.2.4
SWALE COMPLETE 02/21/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 02/20/2024 02/27/2024
Note: Held By: JPI 1. Provide correct revision numbers (i.e. R6) for ALL products listed. 107.2.4 2. Window in shower appears omitted from City of Palm Coast Product Approval Specification Sheet. 107.2.4 3. Provide correct Florida Product Approval Number for a specific product; vertical aluminum mullion appears INCORRECT. 107.2.4 4. Roofing Products: asphalt shingle and underlayment Florida Product Approval Numbers on the City of Palm Coast Product Approval Specification Sheet do not appear to match those numbers provided on the City of Palm Coast Roofing Worksheet. 107.2.4 5. Off-ridge Vent product approval number appears ommitted from the City of Palm Coast Product Approval Specification Sheet. 107.2.4 6. Structural Component Florida Product Approval Numbers appear omitted. Include Structural Components. 107.2.4
CUSVC COMPLETE 02/20/2024 02/22/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/20/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/20/2024 02/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 02/20/2024 02/26/2024
LOCATE COMPLETE 02/20/2024 02/26/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 02/20/2024 02/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/20/2024 02/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 02/20/2024 02/22/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Garage orientation on plans does not match site and landscape plans

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 08/16/2024
CONTRACTOR CHANGE ¤20.00 08/16/2024
PLAN REVIEW - REVISION ¤32.50 08/16/2024
PLAN REVIEW - REVISION ¤32.50 08/16/2024
REINSPECTION RESIDENTIAL ¤40.00 08/16/2024
REINSPECTION RESIDENTIAL ¤40.00 08/16/2024
UTILITY PEP REINSPECTION ¤40.00 08/16/2024
SEWER CREDIT (¤650.00) 04/15/2024
SEWER INSPECTION ¤25.00 04/15/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/15/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/15/2024
WORK WITHOUT PERMIT ¤602.74 04/15/2024
SITE PLAN 30 ¤30.00 04/15/2024
CONNECTION FEES ¤1,187.26 04/15/2024
WATER- TURN ON ¤25.00 04/15/2024
ADJUSTMENT 50% (¤602.75) 04/15/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/15/2024
INSPECTION - RESIDENTIAL ¤915.75 04/15/2024
PLAN REVIEW - RESIDENTIAL ¤259.74 04/15/2024
FC IMPACT FEE EMS ¤62.00 04/15/2024
IMPACT FEE FIRE ¤428.09 04/15/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/15/2024
FC IMPACT FEE LIBRARY ¤268.00 04/15/2024
IMPACT FEE PARKS ¤1,800.99 04/15/2024
IMPACT FEE SCHOOL ¤5,450.00 04/15/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/15/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/15/2024
SURCHARGE FS 533.721 ¤12.05 04/15/2024
SURCHARGE - FS 468.631 ¤18.08 04/15/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/15/2024
SW ENG INSPECTION 80 ¤80.00 04/15/2024
SW ENG PRE APRON ¤30.00 04/15/2024
SW ENG - REVIEW 20 ¤20.00 04/15/2024
SW ENG RES REVIEW 200 ¤200.00 04/15/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,977.49