Permit #2024020882
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00230-0060 |
| GARAGE: 455 sqft |
| CONDITIONED SPACE: 1721 sqft |
| OPENED PORCH (WITH ROOF) : 110 sqft |
| OPENED PORCH (WITH ROOF) : 173 sqft |
| Total Square Footage: 2459 sqft |
| Block: 00230 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 631-929-5500 |
| Location Address: 3 POTOMAC DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/15/2024 |
| NOC: RECORDED |
| Applicant name: NICHOLAS JOHN ZOUMAS |
| Owner: ANDREW BLANCO AND DIANA M BARRY |
|
Address 45 POPLAR DRIVE PALM COAST, FL 32164 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤205,000.00 |
| Job Description: Single Family Home |
| Type: CN |
Contractor
JNS CONTRACTING FLORIDA, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
256 ROUTE 25A WADING RIVER, NY 11792 |
CGC1527793 (Exp: 08/31/2026) | 631-929-5500 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/16/2024 | FINAL APPROVED | KSANDOE |
| Note: 8/15/2024 - PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 08/15/2024 | CANCELLED BY APPLICANT | KSANDOE |
| ROW - FINAL APRON (AFTER POUR) | 08/15/2024 | APPROVED | FSLADISH |
| Note: 8/15/24 PIPE ELVATION IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. Inspector Notes from Inspection 9465 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| ROW - STORMWATER FINAL | 08/15/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/15/24 At the time of the inspection all minimum city standards and requirements were met. Niether the Inspector nor the city is responsible if, for whatever reason, site conditions change over time after the Inspection. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| U -UTILITY RESIDENTIAL FINAL | 08/15/2024 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:34:44 PM *** no irr-no cross connection | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/12/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/12/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BARE AREA IN THE REAR AT PROPERTY LINE WILL NEED TO BE SODDED BEFORE ROW FINAL. APPROVING THIS FIELD SURVEY AS NOTED. ______________________________________________________________________________________________________________________ 8/1/2024 - PREVIOUS INSPECTION NOTES 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| ELECTRIC - EARLY POWER | 08/07/2024 | APPROVED | RMARTIN |
| Note: Inspector Notes from Inspection 2200 5/30/24: FPL emailed at @ 13:45. Approved for TUG | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/01/2024 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/01/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 08/01/24 TPOLACEK*** RIGHT SIDE ALONG FENCE LINE YOU MUST CREAT A 4-1 SLOPE. REAR PROPERTY LINE NEEDS TO BE RAISED TO PREVENT DRAINING INTO ADJACENT LOT TO THE REAR. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| GRAVITY SEWER TEST | 07/15/2024 | APPROVED | MGIBSON |
| Note: 4/25/2024 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET | |||
| SEWER TIE IN | 07/15/2024 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 06/24/2024 | APPROVED | CBOWERMASTER |
| Note: 6/21/2024 7:18:38 AM- PREVIOUS INSPECTION NOTES dumpster | |||
| PEP TANK INSTALLATION REQUEST | 06/18/2024 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: dumpster | |||
| INSULATION | 06/18/2024 | APPROVED | KSANDOE |
| ROW- PRE-APRON (PRE-POUR) | 06/18/2024 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ALL ROUGH | 06/17/2024 | APPROVED | KSANDOE |
| Note: 6/13/2024 - PREVIOUS INSPECTION NOTES 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). Great Room: Right side window is missing an anchor on the left jamb (from inside). 3). Master bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 4). Guest bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 5). Guest bathroom: Slab at bathtub drain needs to be fully repaired with cement to make it equal with finished slab surface. 6). Slab at Kitchen Island needs to be fully repaired with cement to make it equal with finished slab surface. | |||
| ALL ROUGH | 06/13/2024 | Disapproved - NO FEE | RSIMS |
| Note: 6/13/24: 1). Installed duct work does not match Energy Calcs submitted. Will need correction or a revision submitted to and approved by the City. 2). Great Room: Right side window is missing an anchor on the left jamb (from inside). 3). Master bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 4). Guest bathroom exhaust fan duct needs to be sealed fully at roof deck. (daylight showing through around duct). 5). Guest bathroom: Slab at bathtub drain needs to be fully repaired with cement to make it equal with finished slab surface. 6). Slab at Kitchen Island needs to be fully repaired with cement to make it equal with finished slab surface. | |||
| ROOF VALLEY & METAL | 06/12/2024 | APPROVED | KSANDOE |
| Note: 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: 1). Need a revision for the underlayment (Gecco) that does not match the modified bitumen underlayment submitted on the Roofing Worksheet. 2). Pallets of shingles need to be distributed more evenly so that they do not exceed the PSF rating on the trusses. 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 2nd request. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/10/2024 | APPROVED | KSANDOE |
| Note: 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: Previously listed item is not resolved. Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 1). 2-ply trusses A01, A17 and B03 are not connected as required by Manufacturer. Marked in Truss Packet. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| LATH/BRICK/ WATER BARRIER | 06/10/2024 | CANCELLED BY INSPECTOR | KSANDOE |
| Note: Wall sheathing was not inspected prior to wire lath installation. | |||
| LATH/BRICK/ WATER BARRIER | 06/10/2024 | APPROVED | KSANDOE |
| WALL SHEATHING | 06/06/2024 | APPROVED | FWILLIS |
| Note: 6/6/24 - ITEM CORRECTED. LATH CAN BE REINSTALLED. 6/5/2024 - PREVIOUS INSPECTION NOTES 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection 2320 re-scheduled. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/05/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 6/5/24: Previously listed item is not resolved. Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 1). 2-ply trusses A01, A17 and B03 are not connected as required by Manufacturer. Marked in Truss Packet. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| WALL SHEATHING | 06/05/2024 | Disapproved - NO FEE | RSIMS |
| Note: 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection 2320 re-scheduled. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspection Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. 6/5/24: Wall sheathing inspection was not completed prior to wire lath being installed. You will need to remove the wire lath so that the wall sheathing can be inspected and then have Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| ROOF VALLEY & METAL | 06/05/2024 | Disapproved - NO FEE | RSIMS |
| Note: 6/5/24: 1). Need a revision for the underlayment (Gecco) that does not match the modified bitumen underlayment submitted on the Roofing Worksheet. 2). Pallets of shingles need to be distributed more evenly so that they do not exceed the PSF rating on the trusses. 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations.) 2nd request. Inspector Notes from Inspection 2320 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| U-CROSS CONNECTION | 05/31/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 5/31/2024 2:34:44 PM *** no irr-no cross connection | |||
| LATH/BRICK/ WATER BARRIER | 05/30/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 5/30/24: Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. | |||
| ELECTRIC-TUG | 05/30/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 5/30/24: FPL emailed at @ 13:45. Approved for TUG | |||
| TIE BEAM / LINTEL | 05/09/2024 | APPROVED | RSIMS |
| Note: 5/8/2024 - PREVIOUS INSPECTION NOTES 5/7/2024 - PREVIOUS INSPECTION NOTES 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) 05-08-2024 S-1 Lintel D missing bottom rebar. | |||
| TIE BEAM / LINTEL | 05/08/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 5/7/2024 - PREVIOUS INSPECTION NOTES 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) 05-08-2024 1. S-1 Lintel D missing bottom rebar. 2. Dowel not proper clearance as noted on earlier inspection. 3. Please provide a large readable set of approved drawings for all inspections. Drawings are too blurry to read. | |||
| TIE BEAM / LINTEL | 05/07/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/7/24: Previously listed item 3 remains unresolved. Drilled rod is not installed properly. 6" minimum embedment with full EPOXY adhesive. Many down cells now have loose debris in them. Cells must be clean of loose debris. R606.3.4 Trash & debris piles still need to be cleaned up and put in dumpster on site. 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) | |||
| TIE BEAM / LINTEL | 05/06/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/6/24: Please have piles of trash & debris cleaned up to make site safe for inspections. Marked on plans. 1). Windows sills exceed maximum thickness of 1/2" per FBC-R606.3.1 (highlighted). 1 missing also. 2). Back left corner: missing tie wire. 3). Left side: Dowel does not have the required spacing for Mortar. (R606.3.4). (3/4" minimum from the inside surface of the CMU on all sides) | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/06/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 04/29/2024 | APPROVED | BTAYLOR |
| Note: 4/26/2024 - PREVIOUS INSPECTION NOTES 4/26/24: 1). Drain protective sleeve is not fully through the footer. (Code corrected). 305.3 Pipes through foundation walls. Any pipe that passes through a foundation wall shall be provided with a relieving arch, or a pipe sleeve pipe shall be built into the foundation wall. The sleeve shall be two pipe sizes greater than the pipe passing through the wall. | |||
| MONOLITHIC SLAB | 04/26/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/26/24: 1). Drain protective sleeve is not fully through the footer. (Code corrected from original result). 305.3 Pipes through foundation walls. Any pipe that passes through a foundation wall shall be provided with a relieving arch, or a pipe sleeve pipe shall be built into the foundation wall. The sleeve shall be two pipe sizes greater than the pipe passing through the wall. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/25/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 04/25/2024 | Disapproved - NO FEE | MGIBSON |
| Note: SEWER NOT RAN YET | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/24/2024 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 04/22/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/13/2024 | 06/14/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/05/2024 | 06/11/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/29/2024 | 06/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/24/2024 | 05/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/15/2024 | 05/21/2024 |
| Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM Truss Packet needs to be digitally signed and sealed b the engineer of record. | |||
| ENGIN1 | COMPLETE | 05/06/2024 | 05/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/06/2024 | 05/06/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 04/22/2024 | 04/22/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please note for future- 1st submittal - TYPE- Geo Tech Report - FILE NAME - geo tech report 2nd submittal - TYPE - Geo Tech Certification - FILE NAME - geo tech certification | |||
| BLD | COMPLETE | 04/22/2024 | 04/24/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/19/2024 | 04/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/17/2024 | 04/18/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/16/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| BLD | COMPLETE | 03/20/2024 | 03/21/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/15/2024 | 03/18/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/15/2024 | 03/19/2024 |
| Note: Held By: JPI 1. The provided product approvals include documentation from the 2020 Code cycle. Please remove from the product approvals. FL 16918-R3 notes 2020 Code version. 107.2.4 | |||
| SWALE | COMPLETE | 02/21/2024 | 04/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/20/2024 | 02/27/2024 |
| Note: Held By: JPI 1. Provide correct revision numbers (i.e. R6) for ALL products listed. 107.2.4 2. Window in shower appears omitted from City of Palm Coast Product Approval Specification Sheet. 107.2.4 3. Provide correct Florida Product Approval Number for a specific product; vertical aluminum mullion appears INCORRECT. 107.2.4 4. Roofing Products: asphalt shingle and underlayment Florida Product Approval Numbers on the City of Palm Coast Product Approval Specification Sheet do not appear to match those numbers provided on the City of Palm Coast Roofing Worksheet. 107.2.4 5. Off-ridge Vent product approval number appears ommitted from the City of Palm Coast Product Approval Specification Sheet. 107.2.4 6. Structural Component Florida Product Approval Numbers appear omitted. Include Structural Components. 107.2.4 | |||
| CUSVC | COMPLETE | 02/20/2024 | 02/22/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/20/2024 | 02/21/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/20/2024 | 02/26/2024 |
| LOCATE | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/20/2024 | 02/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/20/2024 | 02/21/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/20/2024 | 02/22/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Garage orientation on plans does not match site and landscape plans |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 08/16/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 08/16/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/16/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/16/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/16/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/16/2024 |
| UTILITY PEP REINSPECTION | ¤40.00 | 08/16/2024 |
| SEWER CREDIT | (¤650.00) | 04/15/2024 |
| SEWER INSPECTION | ¤25.00 | 04/15/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 04/15/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 04/15/2024 |
| WORK WITHOUT PERMIT | ¤602.74 | 04/15/2024 |
| SITE PLAN 30 | ¤30.00 | 04/15/2024 |
| CONNECTION FEES | ¤1,187.26 | 04/15/2024 |
| WATER- TURN ON | ¤25.00 | 04/15/2024 |
| ADJUSTMENT 50% | (¤602.75) | 04/15/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/15/2024 |
| INSPECTION - RESIDENTIAL | ¤915.75 | 04/15/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤259.74 | 04/15/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 04/15/2024 |
| IMPACT FEE FIRE | ¤428.09 | 04/15/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/15/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/15/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 04/15/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/15/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 04/15/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/15/2024 |
| SURCHARGE FS 533.721 | ¤12.05 | 04/15/2024 |
| SURCHARGE - FS 468.631 | ¤18.08 | 04/15/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/15/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/15/2024 |
| SW ENG PRE APRON | ¤30.00 | 04/15/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/15/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/15/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,977.49 |