Permit #2024030071
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00530-0240 |
| CONDITIONED SPACE: 1200 sqft |
| SCREEN PORCH (SOLID ROOF) : 146 sqft |
| GARAGE: 283 sqft |
| CONDITIONED SPACE: 1200 sqft |
| GARAGE: 283 sqft |
| SCREEN PORCH (SOLID ROOF) : 146 sqft |
| PATIO/DECK (NO ROOF) : 29 sqft |
| PATIO/DECK (NO ROOF) : 29 sqft |
| Total Square Footage: 3316 sqft |
| Block: 00530 |
| Subdivision: - |
| Job Phone: 386-283-2035 |
| Location Address: 20 PROSPECT LN |
| Type: DU - DUPLEX |
| Issue Date: 08/16/2024 |
| NOC: RECORDED |
| Applicant name: OLEG BELINSKIY |
| Owner: OSHEROV SLAVA & ELIZABETH OSHEROV H&W |
|
Address 9 CHIDESTER ROAD RANDOLPH, NJ 07869 |
| Lot: 0240 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
FLORIDAS BEST BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE PALM COAST, FL 32164 |
CBC1264760 (Exp: 08/31/2026) | 386-283-2035 |
Sub Contractors
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/28/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/28/2025 8:14:28 AM *** 5/22/2025 - PREVIOUS INSPECTION NOTES 5/22/25: *** Previously noted items listed below remain unresolved. Unit A: New item 1 below. 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2). --->>> The lower wall outlet on the right wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. Unit B: Previous items 4 and 5 below. 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 Not resolved. 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) --->>> The lower wall outlet on the left wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. **______________________________________________________________________________________________________________________** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1 | |||
| U -UTILITY RESIDENTIAL FINAL | 05/28/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 no irr-no cc lower sewer clean out/remove soils from water meter pits | |||
| BLD - BUILDING FINAL | 05/22/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/22/2025 10:48:56 AM *** 5/22/25: *** Previously noted items listed below remain unresolved. Unit A: New item 1 below. 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2). --->>> The lower wall outlet on the right wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. Unit B: Previous items 4 and 5 below. 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 Not resolved. 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) --->>> The lower wall outlet on the left wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. **______________________________________________________________________________________________________________________** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1 | |||
| BLD - BUILDING FINAL | 05/20/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/20/2025 1:28:27 PM *** 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1 | |||
| BLD - BUILDING FINAL | 05/19/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/19/2025 9:34:13 AM *** 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1 | |||
| BLD - BUILDING FINAL | 05/14/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/14/2025 12:19:13 PM *** 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1 | |||
| U-CROSS CONNECTION | 05/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/21/2025 | APPROVED | TPOLACEK |
| Note: 04/21/25 TPOLACEK*** GRADING ISSUES IN FRONT LEFT HAVE BEEN CORRECTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** ALONG LEFT SIDE FROM SWALE TO FRONT OF STRUCTURE BUILDER MUST REMOVE THE BERM AND CREATE A COMMON SWALE WITH A 4-1 SLOPE UP ONTO PROPERTY. THE BERM IS UNMANAGEABLE AND EXCEEDS THE MINIMUM REQUIREMENT OF A 4-1 SLOPE AT PROPERTY LINE. Finished Floor Elevations (FFE): Section 300.01 C(8) V-16 "8)The proposed slopes on the property shall not exceed 4:1 and all slopes must adjoin existing property lines at no greater than a 4:1. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1 in expectation that the vacant lot will be graded to match the adjoining property elevation (Common Swale). • Where an adjacent developed lot does not have a clearly defined swale along the edge of the property, the new lot must utilize a “W” swale as part of their proposed grading plan." | |||
| ROW - FINAL INSPECTION | 04/21/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 04/21/2025 | APPROVED | TPOLACEK |
| Note: PAVERS ARE SET AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/11/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/11/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/11/25 TPOLACEK*** ALONG LEFT SIDE FROM SWALE TO FRONT OF STRUCTURE BUILDER MUST REMOVE THE BERM AND CREATE A COMMON SWALE WITH A 4-1 SLOPE UP ONTO PROPERTY. THE BERM IS UNMANAGEABLE AND EXCEEDS THE MINIMUM REQUIREMENT OF A 4-1 SLOPE AT PROPERTY LINE. Finished Floor Elevations (FFE): Section 300.01 C(8) V-16 "8)The proposed slopes on the property shall not exceed 4:1 and all slopes must adjoin existing property lines at no greater than a 4:1. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1 in expectation that the vacant lot will be graded to match the adjoining property elevation (Common Swale). • Where an adjacent developed lot does not have a clearly defined swale along the edge of the property, the new lot must utilize a “W” swale as part of their proposed grading plan." | |||
| ROW- PRE-APRON (PRE-POUR) | 03/12/2025 | APPROVED | TPOLACEK |
| Note: 03/12/25 TPOLACEK**** YOU ARE APPROVED TO LAY PAVERS ***AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/10/2025 - PREVIOUS INSPECTION NOTES 03/10/25 TPOLACEK**** SPOKE WITH CONTRACTOR ABOUT CONCRETE IN APRON. THEY WILL REMOVE BASE AND POUR CONCRETE AS SELECTED IN PAVER DETAIL SHEET ATTCAHED TO PERMIT. CONTRACTOR WILL HAVE APRON POURED TO MATCH SELECTION AND RECALL FOR NEW INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 03/10/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 03/10/25 TPOLACEK**** SPOKE WITH CONTRACTOR ABOUT CONCRETE IN APRON. THEY WILL REMOVE BASE AND POUR CONCRETE AS SELECTED IN PAVER DETAIL SHEET ATTCAHED TO PERMIT. CONTRACTOR WILL HAVE APRON POURED TO MATCH SELECTION AND RECALL FOR NEW INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PAVER RESTRAINTS | 03/04/2025 | APPROVED | FSLADISH |
| Note: 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 03/04/2025 | PARTIALLY APPROVED | FSLADISH |
| Note: 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ELECTRIC - EARLY POWER | 02/04/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/4/2025 2:39:57 PM *** 2/4/25: FPL emailed to release power. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Both Units: 1). Cover plates missing on Master bathroom switches and outlets. Unit A: 2). Switch and cover plates missing from guest bathroom. 1/30/2025 - PREVIOUS INSPECTION NOTES 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off. | |||
| ELECTRIC - EARLY POWER | 01/31/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/31/2025 1:56:39 PM *** 1/31/25: Both Units: 1). Cover plates missing on Master bathroom switches and outlets. Unit A: 2). Switch and cover plates missing from guest bathroom. 1/30/2025 - PREVIOUS INSPECTION NOTES 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off. | |||
| ELECTRIC - EARLY POWER | 01/30/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/30/2025 2:38:34 PM *** 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off. | |||
| GRAVITY SEWER TEST | 01/03/2025 | APPROVED | CVANSTRAHLEN |
| SEWER TIE IN | 01/03/2025 | APPROVED | CVANSTRAHLEN |
| INSULATION | 12/18/2024 | APPROVED | RSIMS |
| FIREWALL FINAL | 12/13/2024 | APPROVED | RSIMS |
| Note: 12/11/2024 - PREVIOUS INSPECTION NOTES 12/11/24: Cancelled by Applicant via phone call at @ 12:10. Not ready. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4 | |||
| FIREWALL FINAL | 12/11/2024 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/11/2024 12:14:04 PM *** 12/11/24: Cancelled by Applicant via phone call at @ 12:10. Not ready. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4 | |||
| LATH/BRICK/ WATER BARRIER | 12/11/2024 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4 | |||
| ALL ROUGH | 12/09/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4 | |||
| FIREWALL FINAL | 12/09/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/9/2024 2:38:01 PM *** 12/9/24: 1). B side: Back area there is about a 1" x 1" opening where the plywood extends below framing that needs to be sealed. Showed Superintendent. | |||
| FIREWALL DRYWALL NAILING | 12/03/2024 | APPROVED | RSIMS |
| Note: 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24: 1). Firewall areas at the back of the garage at the top where the roof planes change direction will need to be covered with the 5/8" type X drywall also. Please call with questions. | |||
| FIREWALL DRYWALL NAILING | 11/27/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/27/2024 11:53:31 AM *** 11/27/24: 1). Firewall areas at the back of the garage at the top where the roof planes change direction will need to be covered with the 5/8" type X drywall also. Please call with questions. | |||
| ROOF VALLEY & METAL | 11/19/2024 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 11/14/2024 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/14/2024 | APPROVED | CVANSTRAHLEN |
| FIREWALL FRAMING | 11/14/2024 | APPROVED | CVANSTRAHLEN |
| TIE BEAM / LINTEL | 10/30/2024 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/3/2024 2:24:54 PM *** 10/3/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 1). Plans are slightly damaged and starting to come apart. Please provide a new full set of plans for the Inspector's use only. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/30/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 10/03/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/3/2024 2:24:54 PM *** 10/3/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 1). Plans are slightly damaged and starting to come apart. Please provide a new full set of plans for the Inspector's use only. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/01/2024 | APPROVED | MGIBSON |
| Note: 9/30/2024 - PREVIOUS INSPECTION NOTES FBC [A] 107.3.1 NEED STAMPED APPROVED PLANS ON SITE, WATER SERVICE NOT RAN YET | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/30/2024 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: FBC [A] 107.3.1 NEED STAMPED APPROVED PLANS ON SITE, WATER SERVICE NOT RAN YET | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/26/2024 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/25/2024 | CANCELLED BY APPLICANT | WEB |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/24/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 08/26/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please keep in mind that the FFE is proposed almost exactly 10" above the neighbor on the left. This leaves less than half an inch of tolerance for the foundation to be poured higher than proposed. The maximum FFE is 28.73', anything higher than this will be put on HOLD and risk removal. I would recommend lowering the proposed FFE, even if only by 0.1' or 0.2', to allow for a larger tolerance at the foundation. This is only my recommendation and you may keep the FFE at its current proposed elevation if you choose. | |||
| SW1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please keep in mind that the FFE is proposed almost exactly 10" above the neighbor on the left. This leaves less than half an inch of tolerance for the foundation to be poured higher than proposed. The maximum FFE is 28.73', anything higher than this will be put on HOLD and risk removal. I would recommend lowering the proposed FFE, even if only by 0.1' or 0.2', to allow for a larger tolerance at the foundation. This is only my recommendation and you may keep the FFE at its current proposed elevation if you choose. | |||
| ZON | HOLD | 01/14/2025 | 01/14/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring original signatures in to our office for processing | |||
| ZON | COMPLETE | 01/14/2025 | 01/14/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/29/2024 | 10/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/29/2024 | 10/29/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/20/2024 | 09/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/05/2024 | 09/05/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/05/2024 | 09/05/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/05/2024 | 09/05/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ENGIN1 | HOLD | 09/04/2024 | 09/05/2024 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM 2 Revised Site Plans were submitted - neither one is for this address. One is for 11 Prospect and the other os for 9 Slatington. | |||
| SW1 | HOLD | 09/04/2024 | 09/05/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Revised site plan is for wrong house | |||
| ZON | HOLD | 09/04/2024 | 09/05/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Right of way agreement not for this address. Please provide the correct agreement signed by all owners. Once approved we will ask for original Revised site plan submitted not for this address. Please upload correct one showing paver driveway | |||
| BADMIN | INFORMATION | 09/03/2024 | 09/03/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The documents don't match this permit | |||
| BLD | COMPLETE | 08/19/2024 | 08/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/19/2024 | 08/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/07/2024 | 03/07/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/04/2024 | 03/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/04/2024 | 03/06/2024 |
| Note: Held By: JPI 1. Identify U.L. number for “upper tenant firewall detail” drawing on Sht. 2. Chapter 7 2. Detail 4 on Sht. 3 identifies as a firewall detail but no U.L. Listing is provided. Chapter 7 | |||
| ELEC | COMPLETE | 03/04/2024 | 03/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/04/2024 | 03/05/2024 |
| LOCATE | COMPLETE | 03/04/2024 | 03/06/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/04/2024 | 03/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/04/2024 | 04/30/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/31/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 01/31/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/28/2024 |
| WATER- TURN ON | ¤50.00 | 08/16/2024 |
| ADJUSTMENT 50% | (¤821.61) | 08/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/16/2024 |
| INSPECTION - RESIDENTIAL | ¤1,256.75 | 08/16/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤356.46 | 08/16/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 08/16/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 08/16/2024 |
| SURCHARGE FS 533.721 | ¤8.22 | 08/16/2024 |
| SURCHARGE - FS 468.631 | ¤12.32 | 08/16/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/16/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/16/2024 |
| SW ENG PRE APRON | ¤30.00 | 08/16/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/16/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/16/2024 |
| SEWER CREDIT | (¤1,806.00) | 08/16/2024 |
| SEWER INSPECTION | ¤25.00 | 08/16/2024 |
| SEWER CAPITAL FACILITY | ¤10,882.06 | 08/16/2024 |
| WATER CAPITAL FACILITY FEE | ¤7,989.02 | 08/16/2024 |
| SITE PLAN 30 | ¤30.00 | 08/16/2024 |
| CONNECTION FEES | ¤2,374.52 | 08/16/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 08/16/2024 |
| IMPACT FEE FIRE | ¤856.18 | 08/16/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 08/16/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 08/16/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 08/16/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 08/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤40,413.10 |