Permit #2024030071

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00530-0240
CONDITIONED SPACE: 1200 sqft
SCREEN PORCH (SOLID ROOF) : 146 sqft
GARAGE: 283 sqft
CONDITIONED SPACE: 1200 sqft
GARAGE: 283 sqft
SCREEN PORCH (SOLID ROOF) : 146 sqft
PATIO/DECK (NO ROOF) : 29 sqft
PATIO/DECK (NO ROOF) : 29 sqft
Total Square Footage: 3316 sqft
Block: 00530
Subdivision: -
Job Phone: 386-283-2035
Location Address: 20 PROSPECT LN
Type: DU - DUPLEX
Issue Date: 08/16/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: OSHEROV SLAVA & ELIZABETH OSHEROV H&W

Address

9 CHIDESTER ROAD

RANDOLPH, NJ 07869

Lot: 0240
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/28/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/28/2025 8:14:28 AM *** 5/22/2025 - PREVIOUS INSPECTION NOTES 5/22/25: *** Previously noted items listed below remain unresolved. Unit A: New item 1 below. 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2). --->>> The lower wall outlet on the right wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. Unit B: Previous items 4 and 5 below. 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 Not resolved. 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) --->>> The lower wall outlet on the left wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. **______________________________________________________________________________________________________________________** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1
U -UTILITY RESIDENTIAL FINAL 05/28/2025 APPROVED - AS NOTED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irr-no cc lower sewer clean out/remove soils from water meter pits
BLD - BUILDING FINAL 05/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/22/2025 10:48:56 AM *** 5/22/25: *** Previously noted items listed below remain unresolved. Unit A: New item 1 below. 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2). --->>> The lower wall outlet on the right wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. Unit B: Previous items 4 and 5 below. 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 Not resolved. 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) --->>> The lower wall outlet on the left wall (first lower wall outlet past kitchen counter) is still on the small appliance circuit. **______________________________________________________________________________________________________________________** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1
BLD - BUILDING FINAL 05/20/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/20/2025 1:28:27 PM *** 5/20/25: Unit A: Previously listed item 9 remains unresolved. 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 New: 1). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) Unit B: 2). Breakers at spots 14, 16 and 18 are shut off upon arrival (prior to any testing). Could not test Kitchen, garbage disposal, etc. FBC-[A]110.1 3). Guest bathroom: bathtub needs to be fully sealed along tub apron where it meets floor. FBC-P2705.1(3) (must be watertight). 4). Holes in garage CMU above garage door need to be sealed. FBC [A]107.4 5). Wall outlet adjacent counter cannot be on small appliance circuit. NEC-210.52(B)(2) 6). Excess material/debris and equipment in garage needs to be removed. FBC [A]107.4 5/19/2025 - PREVIOUS INSPECTION NOTES 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1
BLD - BUILDING FINAL 05/19/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/19/2025 9:34:13 AM *** 5/19/25: HOUSE IS LOCKED UP TIGHT! KEY CODE NOT WORKING TO OPEN LOCK BOX. 1). Need access for inspection. FBC[A] 110.5 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1
BLD - BUILDING FINAL 05/14/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/14/2025 12:19:13 PM *** 5/14/25: NOT READY! INCOMPLETE INSPECTION! COMPLETE RE-INSPECTION REQUIRED! DO NOT RE-SCHEDULE UNTIL YOU HAVE VISUALLY VERIFIED THAT THE HOUSES ARE CODE COMPLIANT AND READY FOR INSPECTION!!! PARTIAL LIST ONLY!!!!! UNIT A: 1). Kitchen outlets are not GFCI protected. IRC-E3902.6 2). Kitchen Island outlet needs to be moved down below 12" or be eleiminated. This outlet cannot be on the small appliance circuit once moved unless it is moved to the side wall of the island out from under the overhang. 3). Exterior outlets are not GFCI and not Weather rated as required. IRC-E3902.3 / NEC-406.9 4). Range outlet needs to be GFCI protected as it is within 6ft of water. NEC 210.8(A)(7) 5). MC cable in AHU closet needs the required fitting into a blank plate/box. NEC 330.40 6). Missing deadbolt on front door and door handle on lanai door. FBC [A]107.4 7). Holes in garage at water heater feed and low voltage wire need to be sealed with the approved material. FBC-R302.11(4) 8). Surge protector needs to be replaced per the Manufacturer (if abscence of a green light exists). FBC [A]107.4 9). Interior Dryer exhaust needs to capped or plugged (or taped at a minimum). FBC-M1502.4.7 10). Attic access panel needs screws removed from rough framing so it can sit flush with ceiling drywall. FBC-302.11 / FBC [A]107.4 11). Dishwasher not hooked up (but installed in place). Coiuld not test. FBC-[A]110.1 12). Downspouts need to terminate minimum 12" away from building foundation. FBC-R318.5 UNIT B: NO POWER! COULD NOT PERFORM INSPECTION. FBC-[A]110.1
U-CROSS CONNECTION 05/14/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
ROW FIELD SURVEY /GRADING CERTIFICATION 04/21/2025 APPROVED TPOLACEK
Note: 04/21/25 TPOLACEK*** GRADING ISSUES IN FRONT LEFT HAVE BEEN CORRECTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** ALONG LEFT SIDE FROM SWALE TO FRONT OF STRUCTURE BUILDER MUST REMOVE THE BERM AND CREATE A COMMON SWALE WITH A 4-1 SLOPE UP ONTO PROPERTY. THE BERM IS UNMANAGEABLE AND EXCEEDS THE MINIMUM REQUIREMENT OF A 4-1 SLOPE AT PROPERTY LINE. Finished Floor Elevations (FFE): Section 300.01 C(8) V-16 "8)The proposed slopes on the property shall not exceed 4:1 and all slopes must adjoin existing property lines at no greater than a 4:1. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1 in expectation that the vacant lot will be graded to match the adjoining property elevation (Common Swale). • Where an adjacent developed lot does not have a clearly defined swale along the edge of the property, the new lot must utilize a “W” swale as part of their proposed grading plan."
ROW - FINAL INSPECTION 04/21/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 04/21/2025 APPROVED TPOLACEK
Note: PAVERS ARE SET AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/11/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 04/11/2025 Disapproved - NO FEE TPOLACEK
Note: 04/11/25 TPOLACEK*** ALONG LEFT SIDE FROM SWALE TO FRONT OF STRUCTURE BUILDER MUST REMOVE THE BERM AND CREATE A COMMON SWALE WITH A 4-1 SLOPE UP ONTO PROPERTY. THE BERM IS UNMANAGEABLE AND EXCEEDS THE MINIMUM REQUIREMENT OF A 4-1 SLOPE AT PROPERTY LINE. Finished Floor Elevations (FFE): Section 300.01 C(8) V-16 "8)The proposed slopes on the property shall not exceed 4:1 and all slopes must adjoin existing property lines at no greater than a 4:1. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1 in expectation that the vacant lot will be graded to match the adjoining property elevation (Common Swale). • Where an adjacent developed lot does not have a clearly defined swale along the edge of the property, the new lot must utilize a “W” swale as part of their proposed grading plan."
ROW- PRE-APRON (PRE-POUR) 03/12/2025 APPROVED TPOLACEK
Note: 03/12/25 TPOLACEK**** YOU ARE APPROVED TO LAY PAVERS ***AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/10/2025 - PREVIOUS INSPECTION NOTES 03/10/25 TPOLACEK**** SPOKE WITH CONTRACTOR ABOUT CONCRETE IN APRON. THEY WILL REMOVE BASE AND POUR CONCRETE AS SELECTED IN PAVER DETAIL SHEET ATTCAHED TO PERMIT. CONTRACTOR WILL HAVE APRON POURED TO MATCH SELECTION AND RECALL FOR NEW INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 03/10/2025 Disapproved - NO FEE TPOLACEK
Note: 03/10/25 TPOLACEK**** SPOKE WITH CONTRACTOR ABOUT CONCRETE IN APRON. THEY WILL REMOVE BASE AND POUR CONCRETE AS SELECTED IN PAVER DETAIL SHEET ATTCAHED TO PERMIT. CONTRACTOR WILL HAVE APRON POURED TO MATCH SELECTION AND RECALL FOR NEW INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 03/04/2025 APPROVED FSLADISH
Note: 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 03/04/2025 PARTIALLY APPROVED FSLADISH
Note: 3/4/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ELECTRIC - EARLY POWER 02/04/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/4/2025 2:39:57 PM *** 2/4/25: FPL emailed to release power. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Both Units: 1). Cover plates missing on Master bathroom switches and outlets. Unit A: 2). Switch and cover plates missing from guest bathroom. 1/30/2025 - PREVIOUS INSPECTION NOTES 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off.
ELECTRIC - EARLY POWER 01/31/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/31/2025 1:56:39 PM *** 1/31/25: Both Units: 1). Cover plates missing on Master bathroom switches and outlets. Unit A: 2). Switch and cover plates missing from guest bathroom. 1/30/2025 - PREVIOUS INSPECTION NOTES 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off.
ELECTRIC - EARLY POWER 01/30/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/30/2025 2:38:34 PM *** 1/30/25: NOT READY! Contractors working in both units. Both Units: 1). Need surge protectors at Meter Main Panels. NEC-230.67 2). Attic lights are not safed off. NEC-210.70(2)(C) 3). Bathroom switches and outlets are pulled out of the boxes exposing contacts. NEC 110.27 Side B: 4). kitchen cabinet outlet is not safed off.
GRAVITY SEWER TEST 01/03/2025 APPROVED CVANSTRAHLEN
SEWER TIE IN 01/03/2025 APPROVED CVANSTRAHLEN
INSULATION 12/18/2024 APPROVED RSIMS
FIREWALL FINAL 12/13/2024 APPROVED RSIMS
Note: 12/11/2024 - PREVIOUS INSPECTION NOTES 12/11/24: Cancelled by Applicant via phone call at @ 12:10. Not ready. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4
FIREWALL FINAL 12/11/2024 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 12/11/2024 12:14:04 PM *** 12/11/24: Cancelled by Applicant via phone call at @ 12:10. Not ready. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4
LATH/BRICK/ WATER BARRIER 12/11/2024 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4
ALL ROUGH 12/09/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 2:41:32 PM *** 12/9/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). A side: no water pressure. (appears that main water line underground is broken). FBCR P2503.5 2). Both sides: Missing window stickers on all windows. FBC [A]107.4 3). Both sides: Bedroom 2 and 3 windows are missing anchors in center. FBC [A]107.4
FIREWALL FINAL 12/09/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 2:38:01 PM *** 12/9/24: 1). B side: Back area there is about a 1" x 1" opening where the plywood extends below framing that needs to be sealed. Showed Superintendent.
FIREWALL DRYWALL NAILING 12/03/2024 APPROVED RSIMS
Note: 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24: 1). Firewall areas at the back of the garage at the top where the roof planes change direction will need to be covered with the 5/8" type X drywall also. Please call with questions.
FIREWALL DRYWALL NAILING 11/27/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/27/2024 11:53:31 AM *** 11/27/24: 1). Firewall areas at the back of the garage at the top where the roof planes change direction will need to be covered with the 5/8" type X drywall also. Please call with questions.
ROOF VALLEY & METAL 11/19/2024 APPROVED CVANSTRAHLEN
WALL SHEATHING 11/14/2024 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2024 APPROVED CVANSTRAHLEN
FIREWALL FRAMING 11/14/2024 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 10/30/2024 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/3/2024 2:24:54 PM *** 10/3/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 1). Plans are slightly damaged and starting to come apart. Please provide a new full set of plans for the Inspector's use only.
FOUND SURVEY APPROVED (OFFICE) 10/30/2024 APPROVED TBAKER
MONOLITHIC SLAB 10/03/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/3/2024 2:24:54 PM *** 10/3/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 1). Plans are slightly damaged and starting to come apart. Please provide a new full set of plans for the Inspector's use only.
PLUMBING 1ST ROUGH UNDERGROUND 10/01/2024 APPROVED MGIBSON
Note: 9/30/2024 - PREVIOUS INSPECTION NOTES FBC [A] 107.3.1 NEED STAMPED APPROVED PLANS ON SITE, WATER SERVICE NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 09/30/2024 Disapproved -FEE REQUIRED MGIBSON
Note: FBC [A] 107.3.1 NEED STAMPED APPROVED PLANS ON SITE, WATER SERVICE NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 09/26/2024 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 09/25/2024 CANCELLED BY APPLICANT WEB
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/24/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 08/26/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please keep in mind that the FFE is proposed almost exactly 10" above the neighbor on the left. This leaves less than half an inch of tolerance for the foundation to be poured higher than proposed. The maximum FFE is 28.73', anything higher than this will be put on HOLD and risk removal. I would recommend lowering the proposed FFE, even if only by 0.1' or 0.2', to allow for a larger tolerance at the foundation. This is only my recommendation and you may keep the FFE at its current proposed elevation if you choose.
SW1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please keep in mind that the FFE is proposed almost exactly 10" above the neighbor on the left. This leaves less than half an inch of tolerance for the foundation to be poured higher than proposed. The maximum FFE is 28.73', anything higher than this will be put on HOLD and risk removal. I would recommend lowering the proposed FFE, even if only by 0.1' or 0.2', to allow for a larger tolerance at the foundation. This is only my recommendation and you may keep the FFE at its current proposed elevation if you choose.
ZON HOLD 01/14/2025 01/14/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring original signatures in to our office for processing
ZON COMPLETE 01/14/2025 01/14/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/29/2024 10/30/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/29/2024 10/29/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/20/2024 09/24/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2024 09/05/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 HOLD 09/04/2024 09/05/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM 2 Revised Site Plans were submitted - neither one is for this address. One is for 11 Prospect and the other os for 9 Slatington.
SW1 HOLD 09/04/2024 09/05/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Revised site plan is for wrong house
ZON HOLD 09/04/2024 09/05/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Right of way agreement not for this address. Please provide the correct agreement signed by all owners. Once approved we will ask for original Revised site plan submitted not for this address. Please upload correct one showing paver driveway
BADMIN INFORMATION 09/03/2024 09/03/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The documents don't match this permit
BLD COMPLETE 08/19/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 08/19/2024 08/21/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/07/2024 03/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 03/04/2024 03/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 03/04/2024 03/06/2024
Note: Held By: JPI 1. Identify U.L. number for “upper tenant firewall detail” drawing on Sht. 2. Chapter 7 2. Detail 4 on Sht. 3 identifies as a firewall detail but no U.L. Listing is provided. Chapter 7
ELEC COMPLETE 03/04/2024 03/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/04/2024 03/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 03/04/2024 03/05/2024
LOCATE COMPLETE 03/04/2024 03/06/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/04/2024 03/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/04/2024 03/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/04/2024 03/04/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SWALE COMPLETE 03/04/2024 04/30/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/28/2025
REINSPECTION RESIDENTIAL ¤40.00 05/28/2025
REINSPECTION RESIDENTIAL ¤40.00 05/28/2025
REINSPECTION RESIDENTIAL ¤40.00 04/10/2025
REINSPECTION RESIDENTIAL ¤40.00 01/31/2025
RECORDING FEE REIMBURSE DOC ¤44.00 01/31/2025
REINSPECTION RESIDENTIAL ¤40.00 10/28/2024
WATER- TURN ON ¤50.00 08/16/2024
ADJUSTMENT 50% (¤821.61) 08/16/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/16/2024
INSPECTION - RESIDENTIAL ¤1,256.75 08/16/2024
PLAN REVIEW - RESIDENTIAL ¤356.46 08/16/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 08/16/2024
WATER -IRRIGATION INSPECTION ¤50.00 08/16/2024
SURCHARGE FS 533.721 ¤8.22 08/16/2024
SURCHARGE - FS 468.631 ¤12.32 08/16/2024
SW ENG - FOUNDATION SURVEY ¤20.00 08/16/2024
SW ENG INSPECTION 80 ¤80.00 08/16/2024
SW ENG PRE APRON ¤30.00 08/16/2024
SW ENG - REVIEW 20 ¤20.00 08/16/2024
SW ENG RES REVIEW 200 ¤200.00 08/16/2024
SEWER CREDIT (¤1,806.00) 08/16/2024
SEWER INSPECTION ¤25.00 08/16/2024
SEWER CAPITAL FACILITY ¤10,882.06 08/16/2024
WATER CAPITAL FACILITY FEE ¤7,989.02 08/16/2024
SITE PLAN 30 ¤30.00 08/16/2024
CONNECTION FEES ¤2,374.52 08/16/2024
FC IMPACT FEE EMS ¤124.00 08/16/2024
IMPACT FEE FIRE ¤856.18 08/16/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 08/16/2024
FC IMPACT FEE LIBRARY ¤536.00 08/16/2024
IMPACT FEE PARKS ¤3,600.18 08/16/2024
IMPACT FEE SCHOOL ¤10,900.00 08/16/2024
Fees Total Due: ¤0.00 Total Paid: ¤40,413.10