I want to search for...

Permit #2024030303

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00010-0100
CONDITIONED SPACE: 2526 sqft
GARAGE: 821 sqft
OPENED PORCH (WITH ROOF) : 368 sqft
Total Square Footage: 3715 sqft
Block: 00010
Subdivision: -
Job Phone: 386-931-5741
Location Address: 20 COLECHESTER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/09/2024
NOC: RECORDED
Applicant name: MICHAEL MARINO HANSEN
Owner: ALARCON BROOKE & ANDRES H&W

Address

1323 MILLBROOK TRAIL

ANN ARBOR, MI 48108

Lot: 0100
Contracted Stated Job Value: ¤348,588.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RBI HOMES
Status Location Address State License Number Phone
ACTIVE

PO BOX 1347

PALM COAST, FL 32137

RB29003877 (Exp: 08/31/2027) 386-585-4097

Sub Contractors

ARTHUR J PASCOE
Status Location Address State License Number Phone
ACTIVE

PO BOX 730007

ORMOND BEACH, FL 32174

EC13007168 (Exp: 08/31/2026) 386-547-6439
WILLIAM ROBERT BARRICK
Status Location Address Mailing Address State License Number Phone
CANCEL

50 LEANNI WAY

PALM COAST, FL 32137

STE E2

PALM COAST, FL 32137

RC29027799 (Exp: 08/31/2025) 229-375-9123
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/22/2025 FINAL APPROVED HCAMACHO
Note: 1/21/2025 - PREVIOUS INSPECTION NOTES 1. A/C Unit is flush with grade. FBCR M1403.2 2. Switch outlets in Guest Bedrooms are not working.FBC EC R404.1 3. Missing Surge protector on the outside Panel. NEC 230.67(B) SPD MUST BE LOCATED IN OR ADJACENT TO THE SERVICE EQUIPMENT NEC 230.67SURGE PROTECTOR INSTALLED (2024) 4. Outlets on the sides of the island can not be lower then 12" from the top. NEC 210.52 NO OUTLETS LOWER THEN 12” BELOW A COUNTERTOP AND SHALL NO BE INSTALLED IF A SURFACE EXTENDS MORE THEN 6”
BLD - BUILDING FINAL 01/21/2025 Disapproved - NO FEE HCAMACHO
Note: 1. A/C Unit is flush with grade. FBCR M1403.2 2. Switch outlets in Guest Bedrooms are not working.FBC EC R404.1 3. Missing Surge protector on the outside Panel. NEC 230.67(B) SPD MUST BE LOCATED IN OR ADJACENT TO THE SERVICE EQUIPMENT NEC 230.67SURGE PROTECTOR INSTALLED (2024) 4. Outlets on the sides of the island can not be lower then 12" from the top. NEC 210.52 NO OUTLETS LOWER THEN 12” BELOW A COUNTERTOP AND SHALL NO BE INSTALLED IF A SURFACE EXTENDS MORE THEN 6”
U-CROSS CONNECTION 01/21/2025 APPROVED - AS NOTED LFITZGERALD
Note: irrigation meter plus PVB-no cross connection
U -UTILITY RESIDENTIAL FINAL 01/21/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/17/2025 APPROVED GBERTOLA
Note: 1/17/25= CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 1/16/2025 - PREVIOUS INSPECTION NOTES ** 01/16/25 YOUR FINAL SURVEY SHOWS YOUR DRAINAGE IS STILL NEGATIVELY IMPACTING THE ADJACENT IMPROVED PROPERTY ON THE RIGHT ___________________________________________________________________________________________________________________ 1/10/2025 - PREVIOUS INSPECTION NOTES 1/10/25=We need to achieve a positive flow from the back to the front in the right-back corner and left side of the backyard. The elevations should range from 10.20 to 10.30 and 10.70. On the left side, we have a similar issue: the elevations also need to rise from 10.20 to 10.30 and then to 10.50. If you have any questions, please contact your Stormwater Inspector, Emadison. 12/26/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL FROM BACK TO THE FRONT. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. ----------------------------------------------------------------- 12/16/2024 - PREVIOUS INSPECTION NOTES ** 12/16/24 YOUR PROPOSED DRAINAGE ON YOUR SITE PLAN SHOWS IT FLOWING FROM THE REAR TO THE FRONT, YOU HAVE ALTERED YOUR DRAINAGE FROM WHAT WAS PROPOSED SEE ATTACHED NOTICE THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS ON APRIL 9, 2024 ** THERE NEEDS TO BE A MINIMUM OF .30 FROM THE BOTTOM OF YOUR INSIDE SWALE TO THE TOP OF THE BERM ALONG THE PROPERTY LINES ** RIGHT SIDE ROAD SIDE SWALE IS .50 LOWER NEED TO RAISE TO MATCH THE EXISTING PROPERTY LINE WHICH WILL HOLD WATER YOU NEED TO HAVE POSTIVE FLOW **"Sec 300.01(4,5,6) Positive fall is considered to be 0.10 feet in 20 feet. *** CONTRACTORS NEWSFLASH *** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/17/2025 APPROVED - AS NOTED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - STORMWATER FINAL 01/17/2025 APPROVED GBERTOLA
Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - FINAL APRON (AFTER POUR) 01/17/2025 APPROVED GBERTOLA
Note: Inspector Notes from Inspection 9465 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/16/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 01/16/25 YOUR FINAL SURVEY SHOWS YOUR DRAINAGE IS STILL NEGATIVELY IMPACTING THE ADJACENT IMPROVED PROPERTY ON THE RIGHT ___________________________________________________________________________________________________________________ 1/10/2025 - PREVIOUS INSPECTION NOTES 1/10/25=We need to achieve a positive flow from the back to the front in the right-back corner and left side of the backyard. The elevations should range from 10.20 to 10.30 and 10.70. On the left side, we have a similar issue: the elevations also need to rise from 10.20 to 10.30 and then to 10.50. If you have any questions, please contact your Stormwater Inspector, Emadison. 12/26/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL FROM BACK TO THE FRONT. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. ----------------------------------------------------------------- 12/16/2024 - PREVIOUS INSPECTION NOTES ** 12/16/24 YOUR PROPOSED DRAINAGE ON YOUR SITE PLAN SHOWS IT FLOWING FROM THE REAR TO THE FRONT, YOU HAVE ALTERED YOUR DRAINAGE FROM WHAT WAS PROPOSED SEE ATTACHED NOTICE THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS ON APRIL 9, 2024 ** THERE NEEDS TO BE A MINIMUM OF .30 FROM THE BOTTOM OF YOUR INSIDE SWALE TO THE TOP OF THE BERM ALONG THE PROPERTY LINES ** RIGHT SIDE ROAD SIDE SWALE IS .50 LOWER NEED TO RAISE TO MATCH THE EXISTING PROPERTY LINE WHICH WILL HOLD WATER YOU NEED TO HAVE POSTIVE FLOW **"Sec 300.01(4,5,6) Positive fall is considered to be 0.10 feet in 20 feet. *** CONTRACTORS NEWSFLASH *** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/10/2025 Disapproved -FEE REQUIRED GBERTOLA
Note: 1/10/25=We need to achieve a positive flow from the back to the front in the right-back corner and left side of the backyard. The elevations should range from 10.20 to 10.30 and 10.70. On the left side, we have a similar issue: the elevations also need to rise from 10.20 to 10.30 and then to 10.50. If you have any questions, please contact your Stormwater Inspector, Emadison. 12/26/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL FROM BACK TO THE FRONT. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. ----------------------------------------------------------------- 12/16/2024 - PREVIOUS INSPECTION NOTES ** 12/16/24 YOUR PROPOSED DRAINAGE ON YOUR SITE PLAN SHOWS IT FLOWING FROM THE REAR TO THE FRONT, YOU HAVE ALTERED YOUR DRAINAGE FROM WHAT WAS PROPOSED SEE ATTACHED NOTICE THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS ON APRIL 9, 2024 ** THERE NEEDS TO BE A MINIMUM OF .30 FROM THE BOTTOM OF YOUR INSIDE SWALE TO THE TOP OF THE BERM ALONG THE PROPERTY LINES ** RIGHT SIDE ROAD SIDE SWALE IS .50 LOWER NEED TO RAISE TO MATCH THE EXISTING PROPERTY LINE WHICH WILL HOLD WATER YOU NEED TO HAVE POSTIVE FLOW **"Sec 300.01(4,5,6) Positive fall is considered to be 0.10 feet in 20 feet. *** CONTRACTORS NEWSFLASH *** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/26/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL FROM BACK TO THE FRONT. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. ----------------------------------------------------------------- 12/16/2024 - PREVIOUS INSPECTION NOTES ** 12/16/24 YOUR PROPOSED DRAINAGE ON YOUR SITE PLAN SHOWS IT FLOWING FROM THE REAR TO THE FRONT, YOU HAVE ALTERED YOUR DRAINAGE FROM WHAT WAS PROPOSED SEE ATTACHED NOTICE THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS ON APRIL 9, 2024 ** THERE NEEDS TO BE A MINIMUM OF .30 FROM THE BOTTOM OF YOUR INSIDE SWALE TO THE TOP OF THE BERM ALONG THE PROPERTY LINES ** RIGHT SIDE ROAD SIDE SWALE IS .50 LOWER NEED TO RAISE TO MATCH THE EXISTING PROPERTY LINE WHICH WILL HOLD WATER YOU NEED TO HAVE POSTIVE FLOW **"Sec 300.01(4,5,6) Positive fall is considered to be 0.10 feet in 20 feet. *** CONTRACTORS NEWSFLASH *** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/16/2024 Disapproved - NO FEE EMADISON
Note: ** 12/16/24 YOUR PROPOSED DRAINAGE ON YOUR SITE PLAN SHOWS IT FLOWING FROM THE REAR TO THE FRONT, YOU HAVE ALTERED YOUR DRAINAGE FROM WHAT WAS PROPOSED SEE ATTACHED NOTICE THAT WAS SENT TO ALL BUILDERS AND CONTRACTORS ON APRIL 9, 2024 ** THERE NEEDS TO BE A MINIMUM OF .30 FROM THE BOTTOM OF YOUR INSIDE SWALE TO THE TOP OF THE BERM ALONG THE PROPERTY LINES ** RIGHT SIDE ROAD SIDE SWALE IS .50 LOWER NEED TO RAISE TO MATCH THE EXISTING PROPERTY LINE WHICH WILL HOLD WATER YOU NEED TO HAVE POSTIVE FLOW **"Sec 300.01(4,5,6) Positive fall is considered to be 0.10 feet in 20 feet. *** CONTRACTORS NEWSFLASH *** Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW- PROJECT STATUS 11/25/2024 Status Check EMADISON
Note: MEETING WITH THE BUILDER
ROW- PRE-APRON (PRE-POUR) 11/19/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ELECTRIC - EARLY POWER 10/14/2024 APPROVED HCAMACHO
GRAVITY SEWER TEST 09/19/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/19/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 08/28/2024 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 08/23/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 8/16/2024 10:25:55 AM *** Need nail plates at bottom plates where underground is in kitchen NEC 300.4
ALL ROUGH 08/16/2024 APPROVED - AS NOTED LMILLER
Note: *** NOTES ADDED BY LMILLER 8/16/2024 10:25:55 AM *** Need nail plates at bottom plates where underground is in kitchen NEC 300.4
ROOF VALLEY & METAL 07/16/2024 APPROVED JWALKER
WALL SHEATHING 07/12/2024 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2024 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 05/29/2024 APPROVED TBAKER
TIE BEAM / LINTEL 05/23/2024 APPROVED JWALKER
MONOLITHIC SLAB 05/16/2024 APPROVED LMILLER
Note: 5/15/2024 - PREVIOUS INSPECTION NOTES5-16-24 notes below resolved 1. Left side slab area needs to be tamped due to soil over throw during pipe install. 2. Right side of the the slab is not meeting the required 4" minium slab depth shown on the plan. Remove excess soil and tamp. See detail 1 on the foundation plan. Please install test string lines for reinspection. 3. Lap and seal all plastic. Multilple areas.
MONOLITHIC SLAB 05/15/2024 Disapproved - NO FEE JWALKER
Note: 1. Left side slab area needs to be tamped due to soil over throw during pipe install. 2. Right side of the the slab is not meeting the required 4" minium slab depth shown on the plan. Remove excess soil and tamp. See detail 1 on the foundation plan. Please install test string lines for reinspection. 3. Lap and seal all plastic. Multilple areas.
PLUMBING 1ST ROUGH UNDERGROUND 05/10/2024 APPROVED MGIBSON
Note: 5/9/2024 - PREVIOUS INSPECTION NOTES 5/7/2024 - PREVIOUS INSPECTION NOTES MISSED INSPECTION, REMOVE ALL DIRT FROM ''DWV'' WATER DISTRIBUTION LINES REMOVE ALL STEEL FROM SLAB AREA AND FOOTER AREAS FOR INSPECTION.. SEE FIRST ROUGH NOTE FROM 5/7/24
PLUMBING 1ST ROUGH UNDERGROUND 05/09/2024 Disapproved -FEE REQUIRED MGIBSON
Note: 5/7/2024 - PREVIOUS INSPECTION NOTES MISSED INSPECTION, REMOVE ALL DIRT FROM ''DWV'' WATER DISTRIBUTION LINES REMOVE ALL STEEL FROM SLAB AREA AND FOOTER AREAS FOR INSPECTION.. SEE FIRST ROUGH NOTE FROM 5/7/24
PLUMBING 1ST ROUGH UNDERGROUND 05/07/2024 Disapproved -FEE REQUIRED MGIBSON
Note: MISSED INSPECTION, REMOVE ALL DIRT FROM ''DWV'' WATER DISTRIBUTION LINES REMOVE ALL STEEL FROM SLAB AREA AND FOOTER AREAS FOR INSPECTION
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/06/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 04/24/2024 APPROVED CBOWERMASTER
Note: 4/23/2024 7:20:46 AM- PREVIOUS INSPECTION NOTES clearing
WATER METER INSTALLATION REQUEST 04/22/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: clearing

Review History

Department Status Date In Date Out
BLD COMPLETE 07/31/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/28/2024 05/29/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/28/2024 05/28/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 05/02/2024 05/06/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 04/04/2024 04/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 04/04/2024 04/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 03/26/2024 04/01/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 2. Electrical riser diagram needs to include the surge protector and show outside disconnect. NEC 2020 230.67, 230.85
SW1 COMPLETE 03/26/2024 04/04/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
BLD HOLD 03/26/2024 03/30/2024
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
ELEC HOLD 03/20/2024 03/25/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 2. Electrical riser diagram needs to include the surge protector and show outside disconnect. NEC 2020 230.67, 230.85 3rd REQUEST
BLD HOLD 03/20/2024 03/21/2024
Note: Held By: JPI 1. We apologize if we missed something. The following comment still appears to apply: Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
SW1 HOLD 03/20/2024 03/26/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please submit an updated approved site plan for SW1 review. Previous SW1 comments not addressed - missing all proposed elevations
SW1 HOLD 03/13/2024 03/20/2024
Note: Held By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM Please show all proposed site elv's, flow arrows , FF and Garage proposed elv's
ZON COMPLETE 03/13/2024 03/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 03/13/2024 03/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 03/13/2024 03/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector and show outside disconnect. NEC 2020 230.67, 230.85 2nd REQUEST
BADMIN COMPLETE 03/13/2024 03/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 03/13/2024 03/19/2024
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
SWALE COMPLETE 03/08/2024 05/10/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 03/07/2024 03/12/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Geo Tech report needs to be digitally signed and sealed. 2. Truss packet or truss layout must have shop drawing approval stamp by engineer of record who designed the house.
BLD HOLD 03/07/2024 03/12/2024
Note: Held By: JPI 1. Please provide current product approval numbers. 19309.2 does not appear to be an active number. 107.2.4 2. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 03/07/2024 03/08/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 03/07/2024 03/12/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector and show outside disconnect. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 03/07/2024 03/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 03/07/2024 03/12/2024
LOCATE COMPLETE 03/07/2024 03/13/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 03/07/2024 03/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs from listed subcontractor
SW1 HOLD 03/07/2024 03/08/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site plan does not show proposed slab elevation, proposed spot grades, flow arrows, etc.
ZON HOLD 03/07/2024 03/08/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM MISSING TREES ON LANDSCAPE PLAN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 01/17/2025
REINSPECTION FEE ¤40.00 01/17/2025
SW ENG REINSPECTION 20 ¤20.00 01/17/2025
REINSPECTION RESIDENTIAL ¤40.00 01/17/2025
REINSPECTION RESIDENTIAL ¤40.00 01/17/2025
CONNECTION FEES ¤1,187.26 04/09/2024
SW ENG - REVIEW 20 ¤20.00 04/09/2024
SW ENG RES REVIEW 200 ¤200.00 04/09/2024
SEWER CREDIT (¤1,147.00) 04/09/2024
SEWER INSPECTION ¤25.00 04/09/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/09/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/09/2024
SITE PLAN 30 ¤30.00 04/09/2024
SURCHARGE FS 533.721 ¤8.89 04/09/2024
SURCHARGE - FS 468.631 ¤13.33 04/09/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/09/2024
SW ENG INSPECTION 80 ¤80.00 04/09/2024
SW ENG PRE APRON ¤30.00 04/09/2024
WATER-METER ¤514.49 04/09/2024
WATER- TURN ON ¤25.00 04/09/2024
WATER- TURN ON ¤25.00 04/09/2024
ADJUSTMENT 50% (¤888.68) 04/09/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/09/2024
INSPECTION - RESIDENTIAL ¤1,361.25 04/09/2024
PLAN REVIEW - RESIDENTIAL ¤386.10 04/09/2024
FC IMPACT FEE EMS ¤62.00 04/09/2024
IMPACT FEE FIRE ¤428.09 04/09/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/09/2024
FC IMPACT FEE LIBRARY ¤268.00 04/09/2024
IMPACT FEE PARKS ¤1,800.99 04/09/2024
IMPACT FEE SCHOOL ¤5,450.00 04/09/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/09/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/09/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/09/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,655.26