Permit #2024030492
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00760-0120 |
| CONDITIONED SPACE: 1546 sqft |
| GARAGE: 408 sqft |
| OPENED PORCH (WITH ROOF) : 42 sqft |
| Total Square Footage: 1996 sqft |
| Block: 00760 |
| Subdivision: - |
| Job Phone: 904-268-7730 |
| Location Address: 40 RYMSHAW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/22/2024 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES, LLC OF FLORIDA |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DANIEL GREGORY PUGLISI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13011195 (Exp: 08/31/2024) | 407-302-7800 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/02/2024 | FINAL APPROVED | AGAETANO |
| Note: 8/1/2024 - PREVIOUS INSPECTION NOTES 08-01-2024 Doors locked . Need access for inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 08/02/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/2/2024 10:19:56 AM *** just for clarification i ID'd the pep breaker,top one-dont know what 2nd 20 amp is for ,might want to label it ? 8/1/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 8/1/2024 9:58:03 AM *** please seperate the 20-20 breaker so only 1 20 is dedicated to pep tank(not septic by the way) Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:00:09 AM *** no irrigation-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 08/01/2024 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 08/01/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 08/01/2024 | Disapproved - NO FEE | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 8/1/2024 9:58:03 AM *** please seperate the 20-20 breaker so only 1 20 is dedicated to pep tank(not septic by the way) Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:00:09 AM *** no irrigation-no cross connection | |||
| BLD - BUILDING FINAL | 08/01/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 08-01-2024 Doods locked . Need access for inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/30/2024 | APPROVED | TPOLACEK |
| Note: Inspector Notes from Inspection 9270 7/16/24 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. PIPE ELEVATION IS GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 7/15/2024 - PREVIOUS INSPECTION NOTES 7/15/24 YOUR FORMS FOR THE DRIVEWAY APRON ARE IN THE ROAD WAY, THEY MUST BE MOVED BACK TO THE EDGE OF PAVEMENT. YOUR LEFT SIDE CULVERT PIPE NEEDS TO BE 8' TO CENTER OF BOTTOM OF CULVERT PIPE MITERED END IT IS OUT OF TOLERANCE. ON THE RIGHT SIDE YOUR CULVERT END FOOTER HAS WASHED IN, IT NEEDS TO BE 6" X 6" ACCORDING TO COPC STANDARDS. SEE PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9270 7/16/24 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. PIPE ELEVATION IS GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 7/15/2024 - PREVIOUS INSPECTION NOTES 7/15/24 YOUR FORMS FOR THE DRIVEWAY APRON ARE IN THE ROAD WAY, THEY MUST BE MOVED BACK TO THE EDGE OF PAVEMENT. YOUR LEFT SIDE CULVERT PIPE NEEDS TO BE 8' TO CENTER OF BOTTOM OF CULVERT PIPE MITERED END IT IS OUT OF TOLERANCE. ON THE RIGHT SIDE YOUR CULVERT END FOOTER HAS WASHED IN, IT NEEDS TO BE 6" X 6" ACCORDING TO COPC STANDARDS. SEE PHOTOS FOR REFERENCE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/30/2024 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U-CROSS CONNECTION | 07/29/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 7/29/2024 11:00:09 AM *** no irrigation-no cross connection | |||
| ROW- PRE-APRON (PRE-POUR) | 07/16/2024 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 07/16/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/16/24 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. PIPE ELEVATION IS GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 7/15/2024 - PREVIOUS INSPECTION NOTES 7/15/24 YOUR FORMS FOR THE DRIVEWAY APRON ARE IN THE ROAD WAY, THEY MUST BE MOVED BACK TO THE EDGE OF PAVEMENT. YOUR LEFT SIDE CULVERT PIPE NEEDS TO BE 8' TO CENTER OF BOTTOM OF CULVERT PIPE MITERED END IT IS OUT OF TOLERANCE. ON THE RIGHT SIDE YOUR CULVERT END FOOTER HAS WASHED IN, IT NEEDS TO BE 6" X 6" ACCORDING TO COPC STANDARDS. SEE PHOTOS FOR REFERENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 07/15/2024 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 7/15/24 YOUR FORMS FOR THE DRIVEWAY APRON ARE IN THE ROAD WAY, THEY MUST BE MOVED BACK TO THE EDGE OF PAVEMENT. YOUR LEFT SIDE CULVERT PIPE NEEDS TO BE 8' TO CENTER OF BOTTOM OF CULVERT PIPE MITERED END IT IS OUT OF TOLERANCE. ON THE RIGHT SIDE YOUR CULVERT END FOOTER HAS WASHED IN, IT NEEDS TO BE 6" X 6" ACCORDING TO COPC STANDARDS. SEE PHOTOS FOR REFERENCE. | |||
| ELECTRIC - EARLY POWER | 07/02/2024 | APPROVED | RMARTIN |
| SEWER TIE IN | 06/26/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 06/03/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 05/29/2024 | APPROVED | AGAETANO |
| ALL ROUGH | 05/24/2024 | APPROVED | KSANDOE |
| Note: 5/23/2024 - PREVIOUS INSPECTION NOTES 5/23/2024 - PREVIOUS INSPECTION NOTES 05-23-2024 1. Electrcial plans not on site. 2. Hole at the bottom plate of the SGD. 3. Wires in electrical panel not phased out. | |||
| LATH/BRICK/ WATER BARRIER | 05/23/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 05-23-2024 1. Electrcial plans not on site. 2. Hole at the bottom plate of the SGD. 3. Wires in electrical panel not phased out. | |||
| LATH/BRICK/ WATER BARRIER | 05/23/2024 | APPROVED | AGAETANO |
| Note: | |||
| ALL ROUGH | 05/23/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 5/23/2024 - PREVIOUS INSPECTION NOTES 05-23-2024 1. Electrcial plans not on site. 2. Hole at the bottom plate of the SGD. 3. Wires in electrical panel not phased out. | |||
| ROOF VALLEY & METAL | 05/15/2024 | APPROVED | AGAETANO |
| ELECTRIC-TUG | 05/10/2024 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/09/2024 | APPROVED | AGAETANO |
| ROOF SHEATHING | 05/08/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: 05-8-2024 Please leave all anchors visible for Brace/Tie Down inspection. | |||
| WALL SHEATHING | 05/08/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: 05-8-2024 Please leave all anchors visible for Brace/Tie Down inspection. | |||
| MONOLITHIC SLAB | 04/24/2024 | APPROVED | AGAETANO |
| Note: 4/23/2024 - PREVIOUS INSPECTION NOTES 04-23-2024 Termite bond not posted. | |||
| MONOLITHIC SLAB | 04/23/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 04-23-2024 Termite bond not posted. | |||
| MONOLITHIC SLAB | 04/22/2024 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 04/22/2024 | CANCELLED BY INSPECTOR | RSIMS |
| Note: 4/22/24: Wood framed house. Not required. | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/19/2024 | APPROVED | TBAKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/19/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 04/19/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/16/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 04/05/2024 | APPROVED | BVITALE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/29/2024 | 06/03/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/16/2024 | 04/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/16/2024 | 04/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/16/2024 | 04/16/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/15/2024 | 04/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter seems to be a copy or someone opened and broke the sea. Resubmit letter. | |||
| BLD | HOLD | 04/12/2024 | 04/15/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter seems to be a copy or someone opened and broke the sea. Resubmit letter. | |||
| BADMIN | COMPLETE | 04/05/2024 | 04/05/2024 |
| Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 04/02/2024 | 04/02/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT PERMIT APPLICATION WITH NEW OWNER INFO | |||
| ELEC | COMPLETE | 03/20/2024 | 03/20/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/12/2024 | 03/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/12/2024 | 03/19/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 03/12/2024 | 03/13/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/12/2024 | 03/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electric load calcs are done by a contractor thats not listed on your permit. | |||
| ENGIN1 | COMPLETE | 03/12/2024 | 03/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/12/2024 | 03/13/2024 |
| LOCATE | COMPLETE | 03/12/2024 | 03/14/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/12/2024 | 03/14/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/12/2024 | 03/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/12/2024 | 03/12/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/12/2024 | 05/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 08/02/2024 |
| SW ENG REINSPECTION 30 | ¤30.00 | 08/02/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/22/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/22/2024 |
| SEWER CREDIT | (¤1,466.00) | 03/22/2024 |
| SEWER INSPECTION | ¤25.00 | 03/22/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 03/22/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 03/22/2024 |
| SITE PLAN 30 | ¤30.00 | 03/22/2024 |
| WATER- TURN ON | ¤25.00 | 03/22/2024 |
| ADJUSTMENT 50% | (¤519.79) | 03/22/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/22/2024 |
| INSPECTION - RESIDENTIAL | ¤786.50 | 03/22/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤223.08 | 03/22/2024 |
| CONNECTION FEES | ¤1,187.26 | 03/22/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 03/22/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 03/22/2024 |
| IMPACT FEE FIRE | ¤428.09 | 03/22/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/22/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/22/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 03/22/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/22/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 03/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/22/2024 |
| SURCHARGE FS 533.721 | ¤5.20 | 03/22/2024 |
| SURCHARGE - FS 468.631 | ¤7.80 | 03/22/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/22/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/22/2024 |
| SW ENG PRE APRON | ¤30.00 | 03/22/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,316.17 |