I want to search for...

Permit #2024030730

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00930-0230
CONDITIONED SPACE: 1555 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
GARAGE: 434 sqft
Total Square Footage: 2201 sqft
Block: 00930
Subdivision: -
Job Phone: 832-726-2202
Location Address: 20 BUFFALO BILL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/15/2024
NOC: RECORDED
Applicant name: JONATHON AMBAR
Owner: ZZMZ CASPIAN LLC

Address

1802 N ALAFAYA TRAIL 162

ORLANDO, FL 32826

Lot: 0230
Contracted Stated Job Value: ¤131,500.00
Job Description: Single Family Home
Type: CN

Contractor

CASPIAN HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

1802 N ALAFAYA TRAIL

ORLANDO, FL 32826

SUITE 162

ORLANDO, FL 32826

CBC1264918 (Exp: 08/31/2026) 832-726-2202

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
ALEKSANDRA LUSHI
Status Location Address Mailing Address State License Number Phone
INACTIVE

9360 CRAVEN RD

JACKSONVILLE, FL 32257

APT 401

JACKSONVILLE, FL 32257

CAC1820975 (Exp: 08/31/2026) 904-338-8522
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/17/2024 FINAL APPROVED JSTEWART
Note: 12/12/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 12/12/2024 11:12:49 AM *** 1. Need to install solid soffit at all 3 exhaust terminations, 36"each way from center of exhaust. M1502.3 2. 1 of the exhaust termination points is blocked. All 3 needs to be secured in place. 3. Please raise AC Pad min 3" above surrounding ground. FBCR M1305.1.4.1 4. Missing Fascia (Flashing) at garage overhang terminating at front entry. R402.4.1.1 5. Master shower Hot water direction is backwards. FPBC 607.4 6. Kitchen sink drain vent missing air admittance valve. P3112 7. Missing Nut at anchor for garage door Bucks. per plan 8. Dryer Receptacle requires GFCI Protection. NEC 210.8 12/10/2024 - PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 12/12/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 12/12/2024 11:12:49 AM *** 1. Need to install solid soffit at all 3 exhaust terminations, 36"each way from center of exhaust. M1502.3 2. 1 of the exhaust termination points is blocked. All 3 needs to be secured in place. 3. Please raise AC Pad min 3" above surrounding ground. FBCR M1305.1.4.1 4. Missing Fascia (Flashing) at garage overhang terminating at front entry. R402.4.1.1 5. Master shower Hot water direction is backwards. FPBC 607.4 6. Kitchen sink drain vent missing air admittance valve. P3112 7. Missing Nut at anchor for garage door Bucks. per plan 8. Dryer Receptacle requires GFCI Protection. NEC 210.8 12/10/2024 - PREVIOUS INSPECTION NOTES
U -UTILITY RESIDENTIAL FINAL 12/10/2024 FINAL APPROVED DHANEY
BLD - BUILDING FINAL 12/10/2024 CANCELLED BY APPLICANT JSTEWART
ROW - STORMWATER FINAL 12/09/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/09/2024 APPROVED EMADISON
Note: ** 12/09/24 ON SITE MEETING WITH BUILDER AND SITE DEVELOPMENT CONTRACTOR, THE FINAL WILL PASS AS POSITIVE FALL CONTINUES BEYOND THE 10 FT AREA. ____________________________________________________________________________________________________________ 12/6/2024 10:23:54 AM- PREVIOUS INSPECTION NOTES ** 12/06/24 YOUR FINAL SURVEY WAS INADVERTLY APPROVED WHEN IT SHOULD HAVE BEEN DISAPPROVED DUE TO THERE NOT BEING ADEQUATE FALL OF 6 INCHES IN THE FIRST 10 FT OFF THE REAR OF YOUR HOUSE ** Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’
ROW FIELD SURVEY /GRADING CERTIFICATION 12/09/2024 APPROVED EMADISON
Note:
ROW - FINAL APRON (AFTER POUR) 12/09/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/06/2024 Disapproved - NO FEE EMADISON
Note: ** 12/06/24 YOUR FINAL SURVEY WAS INADVERTLY APPROVED WHEN IT SHOULD HAVE BEEN DISAPPROVED DUE TO THERE NOT BEING ADEQUATE FALL OF 6 INCHES IN THE FIRST 10 FT OFF THE REAR OF YOUR HOUSE ** Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’
ROW FIELD SURVEY /GRADING CERTIFICATION 12/06/2024 Disapproved - NO FEE EMADISON
Note: ** 12/06/24 YOUR FINAL SURVEY WAS INADVERTLY APPROVED WHEN IT SHOULD HAVE BEEN DISAPPROVED DUE TO THERE NOT BEING ADEQUATE FALL OF 6 INCHES IN THE FIRST 10 FT OFF THE REAR OF YOUR HOUSE ** Sec 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’
ROW- PRE-APRON (PRE-POUR) 11/14/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
U-CROSS CONNECTION 11/04/2024 APPROVED DHANEY
GRAVITY SEWER TEST 11/04/2024 APPROVED MGIBSON
SEWER TIE IN 11/04/2024 APPROVED MGIBSON
ELECTRIC - EARLY POWER 10/25/2024 APPROVED JSTEWART
Note: 10/24/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 10/24/2024 11:56:58 AM *** Please install the following into closed holding boxes. AC condensor, AHU, and HW power. NEC 230.62 / 110.27 Live parts guarded against accidental contact. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:44:47 AM *** Authorize release of email to FPL.
ELECTRIC - EARLY POWER 10/24/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 10/24/2024 11:56:58 AM *** Please install the following into closed holding boxes. AC condensor, AHU, and HW power. NEC 230.62 / 110.27 Live parts guarded against accidental contact. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:44:47 AM *** Authorize release of email to FPL.
PEP TANK INSTALLATION REQUEST 09/17/2024 APPROVED CBOWERMASTER
Note: 9/4/2024 7:31:48 AM- PREVIOUS INSPECTION NOTES dumpster
ROW - DRAINAGE 09/09/2024 APPROVED - AS NOTED EMADISON
Note: ** 09/10/24 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE AND SEDIMENT, AND EROSION CONTROL OF THEIR CONSTRUCTION SITE _________________________________________________________________________________________________________________ 9/6/2024 - PREVIOUS INSPECTION NOTES Builder needs to open swale ends to allow drainage to flow through swale, need to reset temp pipe as it is clogged and not functioning.
ROW - DRAINAGE 09/06/2024 Disapproved - NO FEE TPOLACEK
Note: Builder needs to open swale ends to allow drainage to flow through swale, need to reset temp pipe as it is clogged and not functioning. next inspection monday 09/09
PEP TANK INSTALLATION REQUEST 08/29/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster
ELECTRIC-TUG 08/20/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/20/2024 10:44:47 AM *** Authorize release of email to FPL.
INSULATION 08/20/2024 APPROVED JSTEWART
Note: 8/14/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/14/2024 9:45:33 AM *** front bedroom where batton insulation is installed, Please install Air Baffles for ventilation of attic space. R402.2.3 Eave baffle......R806.3 Vent and insulation clearance
INSULATION 08/14/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/14/2024 9:45:33 AM *** front bedroom where batton insulation is installed, Please install Air Baffles for ventilation of attic space. R402.2.3 Eave baffle......R806.3 Vent and insulation clearance
ALL ROUGH 08/09/2024 APPROVED JSTEWART
Note: 8/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/6/2024 9:54:34 AM *** 1. No energy clacs, or Product approval onsite, FBC [A]107.3.1 2. Please fasten SER cable within 12" of entrance to panel box. NEC 230.51(A) 3. Master bath exhaust duct not connected to fan Assembly. FBCR M1501.1 4. Please install Mechanical fasteners to all exhaust duct connections to fan assembly. FBCR M1601.4.1 5. Please strap all exhaust duct to the top chord of trusses routing to have no flat spots, for condensation build up and for Insulation coverage. FBCR M1601.4.46. 6. Please install Missing gaskets on multiple register boots. FBC EC TABLE 402.4.1.1 7. Water preassure to Low. FBCR P2503.5
ALL ROUGH 08/06/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/6/2024 9:54:34 AM *** 1. No energy clacs, or Product approval onsite, FBC [A]107.3.1 2. Please fasten SER cable within 12" of entrance to panel box. NEC 230.51(A) 3. Master bath exhaust duct not connected to fan Assembly. FBCR M1501.1 4. Please install Mechanical fasteners to all exhaust duct connections to fan assembly. FBCR M1601.4.1 5. Please strap all exhaust duct to the top chord of trusses routing to have no flat spots, for condensation build up and for Insulation coverage. FBCR M1601.4.46. 6. Please install Missing gaskets on multiple register boots. FBC EC TABLE 402.4.1.1 7. Water preassure to Low. FBCR P2503.5
ROOF VALLEY & METAL 06/28/2024 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 06/28/2024 APPROVED FWILLIS
WALL SHEATHING 06/25/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/25/2024 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 06/24/2024 APPROVED TBAKER
TIE BEAM / LINTEL 06/11/2024 APPROVED JSTEWART
MONOLITHIC SLAB 05/29/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 05/24/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/23/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 05/03/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 06/20/2024 06/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/20/2024 06/20/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 05/16/2024 05/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 05/02/2024 05/07/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Letter must be accompanied by a signed and sealed inspection and certification letter by the geotechnical engineer of record. Engineer’s letter to confirm the following: Site clearing / over excavation was completed and inspected by engineer prior to the placement of fill and engineer confirms clearing and over excavation work is acceptable. Engineer to confirm fill materials were suitable and within specifications. Engineer to confirm the required number and location of field density tests were completed. Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4) Field dentisty Test Must be digiutally signed and sealed.
BLD COMPLETE 03/22/2024 03/22/2024
Note: Released By: JPI
SWALE COMPLETE 03/18/2024 05/29/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 03/15/2024 03/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 03/15/2024 03/19/2024
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 03/15/2024 03/18/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 03/15/2024 03/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/15/2024 03/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 03/15/2024 03/20/2024
LOCATE COMPLETE 03/15/2024 03/19/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/15/2024 03/20/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/15/2024 03/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/15/2024 03/18/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 01/02/2025
REINSPECTION RESIDENTIAL ¤40.00 01/02/2025
REINSPECTION RESIDENTIAL ¤40.00 01/02/2025
REINSPECTION RESIDENTIAL ¤40.00 01/02/2025
SW ENG - INSPECTION 20 ¤20.00 01/02/2025
SW ENG - INSPECTION 20 ¤20.00 01/02/2025
UTILITY PEP REINSPECTION ¤40.00 01/02/2025
SEWER CREDIT (¤850.00) 04/15/2024
SEWER INSPECTION ¤25.00 04/15/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/15/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/15/2024
SITE PLAN 30 ¤30.00 04/15/2024
SW ENG INSPECTION 80 ¤80.00 04/15/2024
SW ENG PRE APRON ¤30.00 04/15/2024
SW ENG - REVIEW 20 ¤20.00 04/15/2024
SW ENG RES REVIEW 200 ¤200.00 04/15/2024
WATER- TURN ON ¤25.00 04/15/2024
ADJUSTMENT 50% (¤544.50) 04/15/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/15/2024
INSPECTION - RESIDENTIAL ¤825.00 04/15/2024
PLAN REVIEW - RESIDENTIAL ¤234.00 04/15/2024
CONNECTION FEES ¤1,187.26 04/15/2024
FC IMPACT FEE EMS ¤62.00 04/15/2024
IMPACT FEE FIRE ¤428.09 04/15/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/15/2024
FC IMPACT FEE LIBRARY ¤268.00 04/15/2024
IMPACT FEE PARKS ¤1,800.99 04/15/2024
IMPACT FEE SCHOOL ¤5,450.00 04/15/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/15/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/15/2024
SURCHARGE FS 533.721 ¤5.45 04/15/2024
SURCHARGE - FS 468.631 ¤8.17 04/15/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/15/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,115.00