Permit #2024030840

Permit Details

Status: FINAL

Parcel Id: 05-11-31-4075-00060-0490
Block: 00060
Subdivision: -
Job Phone: 386-585-0958
Location Address: 49 RIVERS EDGE LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 04/08/2024
NOC: RECORDED
Applicant name: JEFFREY G SPRAGUE
Owner: FORD ALAN C & KATHARINE A H&W & VIVIAN B ELDERS JT

Address

49 RIVERS EDGE LANE

PALM COAST, FL 32137

Lot: 0490
Contracted Stated Job Value: ¤7,144.50
Job Description: PATIO ROOF - TO MATCH EXISTING
Type: CN

Contractor

JGS DESIGN ASSOCIATES, LLC
Status Location Address State License Number Phone
INACTIVE

8 INDIAN MOUND CT

FLAGLER BEACH, FL 32136

CBC1260630 (Exp: 08/31/2026) 386-585-0958

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/28/2024 FINAL APPROVED JWALKER
ALL ROUGH 05/08/2024 Disapproved -FEE REQUIRED LMILLER
Note: repair was not completed per approved engineers repair detail. (Flitch plarte was cut to allow the strong tie to remain) also check nailing pattern to be sure it complies with the approved repair detail
ALL ROUGH 05/08/2024 APPROVED LMILLER
Note: 5-8-24 second entry this was resulted in error as a failed roof sheathing braces ties downcell inspection a few monents ago the correct result is approved (the fee was removed from the failure notification) 5/8/2024 - PREVIOUS INSPECTION NOTES repair was not completed per approved engineers repair detail. (Flitch plarte was cut to allow the strong tie to remain) also check nailing pattern to be sure it complies with the approved repair detail
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2024 APPROVED BTAYLOR
Note: 4/19/2024 - PREVIOUS INSPECTION NOTES 1. Panel ends need to be fastened to new 2x8 wood valley plate per manufacturer specs for sheathing 2. New SYP PT sill plate missing .5 inch x 6 inch bolt w/washer per plans FBC 107.3 3. New SYP ledger needs 2 .5 inch x 5 inch Lag within 4 inches of each end and at 32 max OC thereafter 4. Rafters cannot be notched more than one fourth the rafter depth R802.7.1 Sawn lumber. Cuts, notches and holes in solid lumber joists, rafters, blocking and beams cannot be cut or notched more than one fourth the depth of the board and must bear on the heal portion of the cut per (FBC-R 802.7.1 and figure 802.7.1.1 and 802.7.1.2 ( please reconstruct per common practices or obtain an approved repair from the RDP).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/19/2024 Disapproved -FEE REQUIRED LMILLER
Note: 1. Panel ends need to be fastened to new 2x8 wood valley plate per manufacturer specs for sheathing 2. New SYP PT sill plate missing .5 inch x 6 inch bolt w/washer per plans FBC 107.3 3. New SYP ledger needs 2 .5 inch x 5 inch Lag within 4 inches of each end and at 32 max OC thereafter 4. Rafters cannot be notched more than one fourth the rafter depth R802.7.1 Sawn lumber. Cuts, notches and holes in solid lumber joists, rafters, blocking and beams cannot be cut or notched more than one fourth the depth of the board and must bear on the heal portion of the cut per (FBC-R 802.7.1 and figure 802.7.1.1 and 802.7.1.2 ( please reconstruct per common practices or obtain an approved repair from the RDP).

Review History

Department Status Date In Date Out
BLD COMPLETE 04/23/2024 04/30/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/23/2024 04/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/02/2024 04/08/2024
Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM REPEAT COMMENT 5. All Plans need to be from 2023 code cycle. Cover Sheet indicates 2020 FBC, Residential 6. OKAY. Plans revised - 12" soffit
BLD HOLD 03/27/2024 04/02/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All plan sheets must have a verifiable digital signature / seal. Seals are manual type and some plan sheets have no seal. 2. Plan sheets, especially the "S" plan sheets are ilegible. They appear to be photocopies and are unreadable. 3. Provide decimal points for all products on roofing worksheet and product approval worksheet. 4. Provide completed product approval worksheet. Include soffit material and structural components. provide decimal point for all products 5. All Plans need to be from 2023 code cycle 6. Soffits are over 12 inches. Provide midpoint span on detail per 1410.3 FBC Building 2023 8th edition 7. Roofing worksheet needs to be the most current one. 8. Roofing underlayment number needs to be updated to the most current code cycle.
BLD HOLD 03/19/2024 03/25/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. All plan sheets must have a verifiable digital signature / seal. Seals are manual type and some plan sheets have no seal. 2. Plan sheets, especially the "S" plan sheets are ilegible. They appear to be photocopies and are unreadable. 3. Provide decimal points for all products on roofing worksheet and product approval worksheet. 4. Provide completed product approval worksheet. Include soffit material and structural components. provide decimal point for all products 5. All Plans need to be from 2023 code cycle 6. Soffits are over 12 inches. Provide midpoint span on detail per 1410.3 FBC Building 2023 8th edition
ELEC CANCEL 03/19/2024 03/25/2024
MECH CANCEL 03/19/2024 03/22/2024
PLUM CANCEL 03/19/2024 03/20/2024
ZON COMPLETE 03/19/2024 03/19/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/30/2024
REINSPECTION RESIDENTIAL ¤40.00 04/30/2024
SURCHARGE FS 533.721 ¤2.00 04/08/2024
SURCHARGE - FS 468.631 ¤2.00 04/08/2024
SITE PLAN 30 ¤30.00 04/08/2024
ADJUSTMENT 50% (¤77.50) 04/08/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/08/2024
INSPECTION - RESIDENTIAL ¤60.00 04/08/2024
PLAN REVIEW - RESIDENTIAL ¤65.00 04/08/2024
Fees Total Due: ¤0.00 Total Paid: ¤184.00