Permit #2024030840
Permit Details
Status: FINAL
| Parcel Id: 05-11-31-4075-00060-0490 |
| Block: 00060 |
| Subdivision: - |
| Job Phone: 386-585-0958 |
| Location Address: 49 RIVERS EDGE LN |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 04/08/2024 |
| NOC: RECORDED |
| Applicant name: JEFFREY G SPRAGUE |
| Owner: FORD ALAN C & KATHARINE A H&W & VIVIAN B ELDERS JT |
|
Address 49 RIVERS EDGE LANE PALM COAST, FL 32137 |
| Lot: 0490 |
| Contracted Stated Job Value: ¤7,144.50 |
| Job Description: PATIO ROOF - TO MATCH EXISTING |
| Type: CN |
Contractor
JGS DESIGN ASSOCIATES, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 INDIAN MOUND CT FLAGLER BEACH, FL 32136 |
CBC1260630 (Exp: 08/31/2026) | 386-585-0958 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/28/2024 | FINAL APPROVED | JWALKER |
| ALL ROUGH | 05/08/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: repair was not completed per approved engineers repair detail. (Flitch plarte was cut to allow the strong tie to remain) also check nailing pattern to be sure it complies with the approved repair detail | |||
| ALL ROUGH | 05/08/2024 | APPROVED | LMILLER |
| Note: 5-8-24 second entry this was resulted in error as a failed roof sheathing braces ties downcell inspection a few monents ago the correct result is approved (the fee was removed from the failure notification) 5/8/2024 - PREVIOUS INSPECTION NOTES repair was not completed per approved engineers repair detail. (Flitch plarte was cut to allow the strong tie to remain) also check nailing pattern to be sure it complies with the approved repair detail | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2024 | APPROVED | BTAYLOR |
| Note: 4/19/2024 - PREVIOUS INSPECTION NOTES 1. Panel ends need to be fastened to new 2x8 wood valley plate per manufacturer specs for sheathing 2. New SYP PT sill plate missing .5 inch x 6 inch bolt w/washer per plans FBC 107.3 3. New SYP ledger needs 2 .5 inch x 5 inch Lag within 4 inches of each end and at 32 max OC thereafter 4. Rafters cannot be notched more than one fourth the rafter depth R802.7.1 Sawn lumber. Cuts, notches and holes in solid lumber joists, rafters, blocking and beams cannot be cut or notched more than one fourth the depth of the board and must bear on the heal portion of the cut per (FBC-R 802.7.1 and figure 802.7.1.1 and 802.7.1.2 ( please reconstruct per common practices or obtain an approved repair from the RDP). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/19/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. Panel ends need to be fastened to new 2x8 wood valley plate per manufacturer specs for sheathing 2. New SYP PT sill plate missing .5 inch x 6 inch bolt w/washer per plans FBC 107.3 3. New SYP ledger needs 2 .5 inch x 5 inch Lag within 4 inches of each end and at 32 max OC thereafter 4. Rafters cannot be notched more than one fourth the rafter depth R802.7.1 Sawn lumber. Cuts, notches and holes in solid lumber joists, rafters, blocking and beams cannot be cut or notched more than one fourth the depth of the board and must bear on the heal portion of the cut per (FBC-R 802.7.1 and figure 802.7.1.1 and 802.7.1.2 ( please reconstruct per common practices or obtain an approved repair from the RDP). |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/23/2024 | 04/30/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/23/2024 | 04/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/02/2024 | 04/08/2024 |
| Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM REPEAT COMMENT 5. All Plans need to be from 2023 code cycle. Cover Sheet indicates 2020 FBC, Residential 6. OKAY. Plans revised - 12" soffit | |||
| BLD | HOLD | 03/27/2024 | 04/02/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All plan sheets must have a verifiable digital signature / seal. Seals are manual type and some plan sheets have no seal. 2. Plan sheets, especially the "S" plan sheets are ilegible. They appear to be photocopies and are unreadable. 3. Provide decimal points for all products on roofing worksheet and product approval worksheet. 4. Provide completed product approval worksheet. Include soffit material and structural components. provide decimal point for all products 5. All Plans need to be from 2023 code cycle 6. Soffits are over 12 inches. Provide midpoint span on detail per 1410.3 FBC Building 2023 8th edition 7. Roofing worksheet needs to be the most current one. 8. Roofing underlayment number needs to be updated to the most current code cycle. | |||
| BLD | HOLD | 03/19/2024 | 03/25/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. All plan sheets must have a verifiable digital signature / seal. Seals are manual type and some plan sheets have no seal. 2. Plan sheets, especially the "S" plan sheets are ilegible. They appear to be photocopies and are unreadable. 3. Provide decimal points for all products on roofing worksheet and product approval worksheet. 4. Provide completed product approval worksheet. Include soffit material and structural components. provide decimal point for all products 5. All Plans need to be from 2023 code cycle 6. Soffits are over 12 inches. Provide midpoint span on detail per 1410.3 FBC Building 2023 8th edition | |||
| ELEC | CANCEL | 03/19/2024 | 03/25/2024 |
| MECH | CANCEL | 03/19/2024 | 03/22/2024 |
| PLUM | CANCEL | 03/19/2024 | 03/20/2024 |
| ZON | COMPLETE | 03/19/2024 | 03/19/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/30/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/30/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/08/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/08/2024 |
| SITE PLAN 30 | ¤30.00 | 04/08/2024 |
| ADJUSTMENT 50% | (¤77.50) | 04/08/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/08/2024 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 04/08/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 04/08/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤184.00 |