I want to search for...
Permit #2024031056
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00690-0010 |
| Block: 00690 |
| Subdivision: 7025 - |
| Job Phone: 386-585-0958 |
| Location Address: 2 PALMWOOD DR |
| Type: STUC - STUCCO / LATH |
| Issue Date: 03/27/2024 |
| NOC: RECORDED |
| Applicant name: JEFFREY G SPRAGUE |
| Owner: ONEAL PAMELA K |
|
Address 2 PALMWOOD DRIVE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤7,200.00 |
| Job Description: REPAIR STUCCO - FRONT |
| Type: CN |
Contractor
JGS DESIGN ASSOCIATES, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 INDIAN MOUND CT FLAGLER BEACH, FL 32136 |
CBC1260630 (Exp: 08/31/2026) | 386-585-0958 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 05/24/2024 | APPROVED | KSANDOE |
| LATH/BRICK/ WATER BARRIER | 05/17/2024 | APPROVED | RSIMS |
| Note: 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24: Spoke to contractor. They will apply a fiber mesh joint in a 'Z' style fashion to make the connection between existing stucco & new scratch coat. Partial approval to visually verify the fiber mesh application at the 2nd inspection. 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24: 1). Existing stucco to new wire lath connection is not complete. You will need to cut back old stucco to expose wire and the overlap from existing wire lath to new wire lath needs to be 3" minimum as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22 | |||
| LATH/BRICK/ WATER BARRIER | 05/15/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/15/24: 1). Existing stucco to new wire lath connection is not complete. You will need to cut back old stucco to expose wire and the overlap from existing wire lath to new wire lath needs to be 3" minimum as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22 | |||
| LATH/BRICK/ WATER BARRIER | 05/15/2024 | PARTIALLY APPROVED | RSIMS |
| Note: 5/15/24: Spoke to contractor. They will apply a fiber mesh joint in a 'Z' style fashion to make the connection between existing stucco & new scratch coat. Partial approval to visually verify the fiber mesh application at the 2nd inspection. 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24: 1). Existing stucco to new wire lath connection is not complete. You will need to cut back old stucco to expose wire and the overlap from existing wire lath to new wire lath needs to be 3" minimum as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22 |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/22/2024 | 03/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/22/2024 | 03/25/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤61.25) | 03/27/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/27/2024 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 03/27/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 03/27/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/27/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/27/2024 |
| SITE PLAN 15 | ¤15.00 | 03/27/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤80.25 |