I want to search for...
Permit #2024040020
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7027-00360-0100 |
| Block: 00360 |
| Subdivision: 7027 - |
| Job Phone: 904-236-5859 |
| Location Address: 11 WOODGATE PL |
| Type: ME - MECHANICAL |
| Issue Date: 04/05/2024 |
| NOC: Unknown |
| Applicant name: ROBERT E GRANT JR |
| Owner: HANNAS DONALD P & KAREN VALCOURT-HANNAS H&W |
|
Address 11 WOODGATE PLACE PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤7,814.00 |
| Job Description: Air Duct Replacement |
| Type: CN |
Contractor
ELITE AC LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10150 BELLE RIVE BLVD JACKSONVILLE, FL 32256 |
#1407 JACKSONVILLE, FL 32256 |
CAC1818659 (Exp: 08/31/2026) | 904-236-5859 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 10/25/2024 | FINAL APPROVED | MKRASKI |
| Note: 9/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 9/27/2024 1:51:51 PM *** Work is in complete not ready. missing register covers, and seal at boot to drywall. as previously noted. FBC [A]107.4 7/26/2024 - PREVIOUS INSPECTION NOTES 7/26/24: 1). New boots installed are not securely mounted between the trusses/joists as required. M1601.4 / M1601.4.4 1a). Please make sure that any new boots have the approved seal from boot flange to drywall as required. 2). Registers re-installed with drywall screws. Screws need to be aluminum or other moisture resistent material. M1601.4.4 7/19/2024 - PREVIOUS INSPECTION NOTES 7/19/24 Via text 7/12/2024 - PREVIOUS INSPECTION NOTES 7/12/24: Cancelled by Applicant via text at @ 08:43. | |||
| HVAC FINAL | 09/27/2024 | Disapproved - NO FEE | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 9/27/2024 1:51:51 PM *** Work is in complete not ready. missing register covers, and seal at boot to drywall. as previously noted. FBC [A]107.4 7/26/2024 - PREVIOUS INSPECTION NOTES 7/26/24: 1). New boots installed are not securely mounted between the trusses/joists as required. M1601.4 / M1601.4.4 1a). Please make sure that any new boots have the approved seal from boot flange to drywall as required. 2). Registers re-installed with drywall screws. Screws need to be aluminum or other moisture resistent material. M1601.4.4 7/19/2024 - PREVIOUS INSPECTION NOTES 7/19/24 Via text 7/12/2024 - PREVIOUS INSPECTION NOTES 7/12/24: Cancelled by Applicant via text at @ 08:43. | |||
| HVAC FINAL | 07/26/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/26/24: 1). New boots installed are not securely mounted between the trusses/joists as required. M1601.4 / M1601.4.4 1a). Please make sure that any new boots have the approved seal from boot flange to drywall as required. 2). Registers re-installed with drywall screws. Screws need to be aluminum or other moisture resitent material. M1601.4.4 7/19/2024 - PREVIOUS INSPECTION NOTES 7/19/24 Via text 7/12/2024 - PREVIOUS INSPECTION NOTES 7/12/24: Cancelled by Applicant via text at @ 08:43. | |||
| HVAC FINAL | 07/19/2024 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 7/19/24 Via text 7/12/2024 - PREVIOUS INSPECTION NOTES 7/12/24: Cancelled by Applicant via text at @ 08:43. | |||
| HVAC FINAL | 07/12/2024 | CANCELLED BY APPLICANT | RSIMS |
| Note: 7/12/24: Cancelled by Applicant via text at @ 08:43. | |||
| HVAC FINAL | 04/19/2024 | CANCELLED BY APPLICANT | WEB |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE - EXTENSION | ¤40.00 | 10/07/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/02/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/05/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/05/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/05/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 04/05/2024 |
| ADJUSTMENT 50% | (¤45.00) | 04/05/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤129.00 |