Permit #2024040045

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00150-0010
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
PATIO/DECK (NO ROOF) : 100 sqft
Total Square Footage: 2346 sqft
Block: 00150
Subdivision: 7022 -
Job Phone: 689-250-2429
Location Address: 2 WESTGRILL PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/13/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0010
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN
Original Permit #: 2023100344

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/07/2025 FINAL APPROVED MCONTRYMAN
Note: 5/1/2025 - PREVIOUS INSPECTION NOTES 5/1/25 1. E-cals do not match equipment installed please submitt a revision for what was installed and have it approved by the Building Dept. before calling in for re-inspection FBC (A)107.4 2. Cable ground block is not accesible NEC 250.94(A) 3. Patch drywall in laundry room behind water heater FBC R402.4.1.1 4/30/2025 - PREVIOUS INSPECTION NOTES 4/30/25 Make ALL repairs before calling in for re-inspection, Items 1,3,4,5 not repaired. ***E-cals must have Building Dept. stamp of approval as well*** 4/28/25 1. Full set of E-cals must be onsite, E-cals do not show equipment model numbers FBC 107.3.1 2. Microwave is still not GFCI protected NEC 210.8 3. Water heater drain pan is required plumbed outside of home FBCR P2801.6 4. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 5. T-stat wiring going into AHU is required to be sealed FBC (A)107.4 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25 1. No permit pack on site, including energy calcs, to verify FBC(A) 107.3.1 2. Dryer vent on roof needs to have screen removed FBCR M1502.3 3. Wall outlet in front of oanty needs to be GFCi protected (less than 6' from sink) NEC 210.8 4. Microwave not GFCi protected/won't trip
BLD - BUILDING FINAL 05/01/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 5/1/25 1. E-cals do not match equipment installed please submitt a revision for what was installed and have it approved by the Building Dept. before calling in for re-inspection FBC (A)107.4 2. Cable ground block is not accesible NEC 250.94(A) 3. Patch drywall in laundry room behind water heater FBC R402.4.1.1 4/30/2025 - PREVIOUS INSPECTION NOTES 4/30/25 Make ALL repairs before calling in for re-inspection, Items 1,3,4,5 not repaired. ***E-cals must have Building Dept. stamp of approval as well*** 4/28/25 1. Full set of E-cals must be onsite, E-cals do not show equipment model numbers FBC 107.3.1 2. Microwave is still not GFCI protected NEC 210.8 3. Water heater drain pan is required plumbed outside of home FBCR P2801.6 4. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 5. T-stat wiring going into AHU is required to be sealed FBC (A)107.4 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25 1. No permit pack on site, including energy calcs, to verify FBC(A) 107.3.1 2. Dryer vent on roof needs to have screen removed FBCR M1502.3 3. Wall outlet in front of oanty needs to be GFCi protected (less than 6' from sink) NEC 210.8 4. Microwave not GFCi protected/won't trip
BLD - BUILDING FINAL 04/30/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 4/30/25 Make ALL repairs before calling in for re-inspection, Items 1,3,4,5 not repaired. ***E-cals must have Building Dept. stamp of approval as well*** 4/28/25 1. Full set of E-cals must be onsite, E-cals do not show equipment model numbers FBC 107.3.1 2. Microwave is still not GFCI protected NEC 210.8 3. Water heater drain pan is required plumbed outside of home FBCR P2801.6 4. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 5. T-stat wiring going into AHU is required to be sealed FBC (A)107.4 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25 1. No permit pack on site, including energy calcs, to verify FBC(A) 107.3.1 2. Dryer vent on roof needs to have screen removed FBCR M1502.3 3. Wall outlet in front of oanty needs to be GFCi protected (less than 6' from sink) NEC 210.8 4. Microwave not GFCi protected/won't trip
ROW - STORMWATER FINAL 04/30/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** AS STATED IN AFTER POUR THERE IS A LARGE CHUNK OF OVER POUR CONCRETE IN MITERED END OF CULVERT. CULVERT SHALL BE FREE AND CLEAR OF DEBRIS AND SEDIMENT BEFORE FINAL ROW WILL BE APPROVED. 4 Concrete extending past the formboards DRAWING 300.G/14 DRAWING 300.G/14. Technical Manual, Drawing 300.E Concrete extending past the formboards, in the swale, must be removed.
BLD - BUILDING FINAL 04/28/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 4/28/25 1. Full set of E-cals must be onsite, E-cals do not show equipment model numbers FBC 107.3.1 2. Microwave is still not GFCI protected NEC 210.8 3. Water heater drain pan is required plumbed outside of home FBCR P2801.6 4. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 5. T-stat wiring going into AHU is required to be sealed FBC (A)107.4 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25 1. No permit pack on site, including energy calcs, to verify FBC(A) 107.3.1 2. Dryer vent on roof needs to have screen removed FBCR M1502.3 3. Wall outlet in front of oanty needs to be GFCi protected (less than 6' from sink) NEC 210.8 4. Microwave not GFCi protected/won't trip
BLD - BUILDING FINAL 04/24/2025 Disapproved - NO FEE MCONTRYMAN
Note: 4/24/25 1. No permit pack on site, including energy calcs, to verify FBC(A) 107.3.1 2. Dryer vent on roof needs to have screen removed FBCR M1502.3 3. Wall outlet in front of oanty needs to be GFCi protected (less than 6' from sink) NEC 210.8
ROW - FINAL APRON (AFTER POUR) 04/24/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/24/25 TPOLACEK** LEFT SIDE CULVERT HAS LARGE CHUNK OF CONCRETE THAT MUST BE REMOVED AND CULVERT MUST BE FREE AND CLEAR OF SEDIMENT. I AM APPROVING THE AFTER POUR AND HOLDING THE FINAL ROW AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 04/24/2025 Disapproved - NO FEE TPOLACEK
Note: 04/24/25 TPOLACEK*** AS STATED IN AFTER POUR THERE IS A LARGE CHUNK OF OVER POUR CONCRETE IN MITERED END OF CULVERT. CULVERT SHALL BE FREE AND CLEAR OF DEBRIS AND SEDIMENT BEFORE FINAL ROW WILL BE APPROVED. 4 Concrete extending past the formboards DRAWING 300.G/14 DRAWING 300.G/14. Technical Manual, Drawing 300.E Concrete extending past the formboards, in the swale, must be removed.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/23/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/22/2025 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIELD SURVEY CAN BE CONDUCTED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/23/2025 APPROVED TPOLACEK
Note: 4/17/2025 - PREVIOUS INSPECTION NOTES 04/17/25 TPOLACEK** FINAL SURVEY DOES NOT MATCH SITE PLAN. THE LEFT REAR CORNER IS .40 LOWER THAN THE FLOW LINE THAT WILL HOLD WATER. THE ENTIRE BACK YARD IS FLAT Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ROW FIELD SURVEY /GRADING CERTIFICATION 04/22/2025 Disapproved - NO FEE TPOLACEK
Note: FINAL SURVEY MUST BE APPROVED BEFORE FIELD SURVEY CAN BE CONDUCTED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/17/2025 Disapproved - NO FEE TPOLACEK
Note: 04/17/25 TPOLACEK** FINAL SURVEY DOES NOT MATCH SITE PLAN. THE LEFT REAR CORNER IS .40 LOWER THAN THE FLOW LINE THAT WILL HOLD WATER. THE ENTIRE BACK YARD IS FLAT Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ROW- PRE-APRON (PRE-POUR) 03/11/2025 APPROVED - AS NOTED TPOLACEK
Note: 03/11/25 TPOLACEK*** LEFT SIDE APRON WING NEEDS TO BO MOVED TO 36" FROM DRIVEWAY EDGE. STRINGLINE FROM BEHOND MITER CULVERT TO FRONT OF CULVERT AND OUTTO THE ROAD THEN MEASURE 36" TO THE LEFT AND THAT IS WHERE BOARD SHOULD BE PLACED. YOU WILL ALSO NEED TO REESTABLISH FOOTERS AFTER RAIN AS THEY ARE WASHED IN. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 2/26/2025 - PREVIOUS INSPECTION NOTES ** 02/26/25 BUILDER ON SITE AT TIME OF INSPECTION CULVERT NEEDS TO BE A STRAIGHT PIPE NOT WITH AN ELBOW SENIOR INSPECTORS P. FLANAGEN AND E. MADISON DETERMINED TO CENTER CULVERT WITHIN THE PROPOSED DRIVEWAY. (LEFT) SIDE CULVERT END WILL BE SET 5 FT FROM EDGE OF ROAD AND THE (RIGHT) SIDE WILL BE SET AT 8 FT FROM EDGE OF ROADWAY. IN INSTANCES WHERE QUESTIONS ARISE AS TO WHERE CULVERT SHOULD BE SET BUILDER SHOULD CONTACT AN INSPECTOR TO ASSIST AND LESSEN THE DELAY IN INSPECTION PROCESS
ROW- PRE-APRON (PRE-POUR) 02/26/2025 CANCELLED BY APPLICANT EMADISON
Note: ** 02/26/25 BUILDER ON SITE AT TIME OF INSPECTION CULVERT NEEDS TO BE A STRAIGHT PIPE NOT WITH AN ELBOW SENIOR INSPECTORS P. FLANAGEN AND E. MADISON DETERMINED TO CENTER CULVERT WITHIN THE PROPOSED DRIVEWAY. (LEFT) SIDE CULVERT END WILL BE SET 5 FT FROM EDGE OF ROAD AND THE (RIGHT) SIDE WILL BE SET AT 8 FT FROM EDGE OF ROADWAY. IN INSTANCES WHERE QUESTIONS ARISE AS TO WHERE CULVERT SHOULD BE SET BUILDER SHOULD CONTACT AN INSPECTOR TO ASSIST AND LESSEN THE DELAY IN INSPECTION PROCESS
ELECTRIC - EARLY POWER 02/24/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 2/24/25 Okay to release e-mail to FPL
GRAVITY SEWER TEST 02/21/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U-CROSS CONNECTION 02/21/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
U - SEWER TIE IN 02/21/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 12/23/2024 APPROVED MKRASKI
Note: 12/20/2024 - PREVIOUS INSPECTION NOTES 12/20/24 1. Multiple unused and used openings missing firestop FBCR 302.11 12/13/2024 - PREVIOUS INSPECTION NOTES 1. E-cals show R5.1 insualtion on CMU walls, 4.1 installed 2. To the right of garage entry door is missing insulation
INSULATION 12/20/2024 Disapproved - NO FEE MCONTRYMAN
Note: 12/20/24 1. Multiple unused and used openings missing firestop FBCR 302.11 12/13/2024 - PREVIOUS INSPECTION NOTES 1. E-cals show R5.1 insualtion on CMU walls, 4.1 installed 2. To the right of garage entry door is missing insulation
INSULATION 12/13/2024 Disapproved - NO FEE MKRASKI
Note: 1. E-cals show R5.1 insualtion on CMU walls, 4.1 installed 2. To the right of garage entry door is missing insulation
LATH/BRICK/ WATER BARRIER 12/10/2024 APPROVED - AS NOTED MKRASKI
Note: 12/4/24 1. Garage entry door exceeds 1/4'' solid blocking is required FBCR 609.1 Check @ insulation
ALL ROUGH 12/04/2024 APPROVED - AS NOTED MKRASKI
Note: 12/4/24 1. Garage entry door exceeds 1/4'' solid blocking is required FBCR 609.1 Check @ insulation 12/3/2024 - PREVIOUS INSPECTION NOTES 12/3/24 1. Missing multiple nail plates NEC 300.4 2. Failed 5' Head test FBC-P2503.5.1 Inspector Notes from Inspection 2450 Inspection not needed
ALL ROUGH 12/03/2024 Disapproved - NO FEE MCONTRYMAN
Note: 12/3/24 1. Missing multiple nail plates NEC 300.4 2. Failed 5' Head test FBC-P2503.5.1 Inspector Notes from Inspection 2450 Inspection not needed
WALL SHEATHING 12/02/2024 APPROVED - AS NOTED MKRASKI
Note: Inspection not needed
ROOF VALLEY & METAL 11/07/2024 APPROVED MKRASKI
ROOF VALLEY & METAL 11/04/2024 Disapproved - NO FEE MKRASKI
Note: 1. Drip edge not nailed off per manufacter specks
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/23/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 12/23/24 Please repair silt fence by next inspection Inspector Notes from Inspection 2340 1. Truss package was delivered on 7/26/24, Trusses will have to have an approved engineered letter and any repairs made, ***Note from mono inspection on 9/16/24***
TIE BEAM / LINTEL 09/30/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Truss package was delivered on 7/26/24, Trusses will have to have an approved engineered letter and any repairs made, ***Note from mono inspection on 9/16/24***
FOUND SURVEY APPROVED (OFFICE) 09/30/2024 APPROVED JMYERS
MONOLITHIC SLAB 09/16/2024 APPROVED - AS NOTED MKRASKI
Note: 1. Truss package was delivered on 7/26/24, Trusses will have to have an approved engineered letter and any repairs made, ***Note from mono inspection on 9/16/24***
MONOLITHIC SLAB 09/12/2024 Disapproved - NO FEE MKRASKI
Note: 9/12/24 1. Not ready, footings filled with water FBC R404.1.3.3.7.4 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 Multiple wash outs in footings FBC R404.1.3.3.7.4 9/3/2024 - PREVIOUS INSPECTION NOTES 1. REQUIRES 6 MIL VAPOR BARRIER FBC R506.2.3 ***At this time truss pack has already been delived, delivery date says 8/27/24 Must protect truss pack from weather per MitTek enginneering packet***
MONOLITHIC SLAB 09/10/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 9/10/24 Multiple wash outs in footings FBC R404.1.3.3.7.4 9/3/2024 - PREVIOUS INSPECTION NOTES 1. REQUIRES 6 MIL VAPOR BARRIER FBC R506.2.3 ***At this time truss pack has already been delived, delivery date says 8/27/24 Must protect truss pack from weather per MitTek enginneering packet***
MONOLITHIC SLAB 09/03/2024 Disapproved - NO FEE MKRASKI
Note: 1. REQUIRES 6 MIL VAPOR BARRIER FBC R506.2.3 ***At this time truss pack has already been delived, delivery date says 8/27/24 Must protect truss pack from weather per MitTek enginneering packet***
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/29/2024 APPROVED CPISCITELLI
PLUMBING 1ST ROUGH UNDERGROUND 08/23/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 07/30/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/01/2025 05/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 12/16/2024 12/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 11/15/2024 11/20/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/05/2024 11/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 11/05/2024 11/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a master permit. Provide only heatload if that is what is changing otherwise if you want to change energy calcs it has to be on the master permit
BLD COMPLETE 10/18/2024 10/24/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/27/2024 09/30/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 09/27/2024 09/27/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 08/28/2024 08/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/18/2024 07/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 07/15/2024 07/15/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM rename your file to geotech report
ZON COMPLETE 04/26/2024 04/26/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 04/22/2024 04/23/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM this is a corner lot the right side should have 6 shrubs (3 gallon) the right side needs banding all around windows
ZON HOLD 04/16/2024 04/17/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM landscape plan: each corner should have 4 3 gallon shrubs your only showing three.
MECH COMPLETE 04/16/2024 04/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/16/2024 04/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 04/01/2024 04/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 04/01/2024 04/05/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/01/2024 04/04/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/01/2024 04/03/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Submit heatload only. remove duct layout and Energy calc pages from file
SW1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/01/2024 04/02/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM landscape plan: each corner should have 4 3 gallon shrubs your only showing three. A/C requires 7 gallon shrubs. Provide proposed sod Color sheet: please provide the manufacturer of the paint for exterior and garage door please add one more form of articulation. Every Fifity feet requires one form
SWALE COMPLETE 04/01/2024 06/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/08/2025
REINSPECTION RESIDENTIAL ¤40.00 05/08/2025
REINSPECTION RESIDENTIAL ¤40.00 05/08/2025
REINSPECTION RESIDENTIAL ¤40.00 05/08/2025
REINSPECTION RESIDENTIAL ¤40.00 11/25/2024
PLAN REVIEW - REVISION ¤32.50 11/25/2024
WATER- TURN ON ¤25.00 05/13/2024
ADJUSTMENT 50% (¤604.51) 05/13/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/13/2024
INSPECTION - RESIDENTIAL ¤918.50 05/13/2024
PLAN REVIEW - RESIDENTIAL ¤260.52 05/13/2024
CONNECTION FEES ¤1,187.26 05/13/2024
FC IMPACT FEE EMS ¤62.00 05/13/2024
IMPACT FEE FIRE ¤428.09 05/13/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/13/2024
FC IMPACT FEE LIBRARY ¤268.00 05/13/2024
IMPACT FEE PARKS ¤1,800.99 05/13/2024
IMPACT FEE SCHOOL ¤5,450.00 05/13/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 05/13/2024
WATER -IRRIGATION INSPECTION ¤25.00 05/13/2024
SURCHARGE FS 533.721 ¤6.05 05/13/2024
SURCHARGE - FS 468.631 ¤9.07 05/13/2024
SW ENG - FOUNDATION SURVEY ¤20.00 05/13/2024
SW ENG INSPECTION 80 ¤80.00 05/13/2024
SW ENG PRE APRON ¤30.00 05/13/2024
SW ENG - REVIEW 20 ¤20.00 05/13/2024
SW ENG RES REVIEW 200 ¤200.00 05/13/2024
SEWER CREDIT (¤957.92) 05/13/2024
SEWER INSPECTION ¤25.00 05/13/2024
SEWER CAPITAL FACILITY ¤5,441.03 05/13/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 05/13/2024
SITE PLAN 30 ¤30.00 05/13/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,053.59