I want to search for...

Permit #2024040051

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00100-0050
GARAGE: 398 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
CONDITIONED SPACE: 1461 sqft
Total Square Footage: 1901 sqft
Block: 00100
Subdivision: 7024 -
Job Phone: 844-885-8913
Location Address: 5 PRINCE MANFRED PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/16/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0050
Contracted Stated Job Value: ¤210,765.37
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/27/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 9/26/2024 1:51:23 PM *** 9/26/24: 1). Outlet on the back of the kitchen counter is not permitted per NEC-210.52(C)(3)(3). 2). Alarm box enclosure has an unused opening into the pull sleeve that is not capped/plugged off or firestopped (NEC 408.7). 3). Dryer exhaust needs to be closed off as required by FBC-M1502.4.7 -- Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked "future use"
BLD - BUILDING FINAL 09/27/2024 FINAL APPROVED KSANDOE
Note: 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24: 1). Outlet on the back of the kitchen counter is not permitted per NEC-210.52(C)(3)(3). 2). Alarm box enclosure has an unused opening into the pull sleeve that is not capped/plugged off or firestopped (NEC 408.7). 3). Dryer exhaust needs to be closed off as required by FBC-M1502.4.7 -- Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked "future use"
U-CROSS CONNECTION 09/27/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/26/2024 2:25:17 PM *** has irr meter with PVB-no cross connection
ROW - FINAL APRON (AFTER POUR) 09/27/2024 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 9/26/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. YOU ARE REQUIRED TO LAY SIDE IN THE REAR ON ALL BARE AREAS TO THE BOTTOM OF THE DITCH LINE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED THAT YOU WILL NEED TO SOD AND STABILIZE BARE AREA AT THE REAR OF PROPERTY.
ROW - STORMWATER FINAL 09/27/2024 APPROVED TPOLACEK
Note: 09/27/24 TPOLACEK*** FRONT SWALE IS NOT MATCHING GRADE AND HOLDING BACK DRAINAGE FROM UPSTREAM. SPOKE WITH CM AND EXPLAINED THEY NEED TO LOWER ELEVATION TO MATCH GRADE OF LEFT AND RIGHT PROPERTIEA TO ALLOW PROPER FLOW. LANDSCAPERS ON SITE DOING WORK NOW WILL APPROVE AS NOTED. Inspector Notes from Inspection 9465 9/26/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. YOU ARE REQUIRED TO LAY SIDE IN THE REAR ON ALL BARE AREAS TO THE BOTTOM OF THE DITCH LINE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED THAT YOU WILL NEED TO SOD AND STABILIZE BARE AREA AT THE REAR OF PROPERTY.
U -UTILITY RESIDENTIAL FINAL 09/27/2024 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/26/2024 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 09/26/2024 APPROVED - AS NOTED FSLADISH
Note: 9/26/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. YOU ARE REQUIRED TO LAY SIDE IN THE REAR ON ALL BARE AREAS TO THE BOTTOM OF THE DITCH LINE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED THAT YOU WILL NEED TO SOD AND STABILIZE BARE AREA AT THE REAR OF PROPERTY.
ROW- PRE-APRON (PRE-POUR) 09/10/2024 APPROVED TPOLACEK
Note: 09/10/24 TPOLACEK** BUILDER ADDED STONE TO POUR AREA. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 9/9/2024 - PREVIOUS INSPECTION NOTES 9/6/2024 - PREVIOUS INSPECTION NOTES THE LEFT INVERT ELEVATION ON THE CULVERT PIPE IS OUT OF TOLERANCE WITH THE PLAN DETAIL. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan
ROW- PRE-APRON (PRE-POUR) 09/09/2024 CANCELLED BY APPLICANT FSLADISH
Note: 9/6/2024 - PREVIOUS INSPECTION NOTES THE LEFT INVERT ELEVATION ON THE CULVERT PIPE IS OUT OF TOLERANCE WITH THE PLAN DETAIL. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan
ROW- PRE-APRON (PRE-POUR) 09/06/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE LEFT INVERT ELEVATION ON THE CULVERT PIPE IS OUT OF TOLERANCE WITH THE PLAN DETAIL. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan
ELECTRIC - EARLY POWER 09/03/2024 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/3/2024 11:57:02 AM *** 9/3/24: FPL emailerd to release power.
GRAVITY SEWER TEST 08/28/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 08/28/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PROJECT STATUS 08/23/2024 APPROVED - AS NOTED TPOLACEK
Note: 08/26/24 TPOLACEK*** SPOT GRDE REQUEST HAS BEEN SUBMITTED FOR PRINCE MANFRED PL BUILDER WILL NEED TO OPEN SWALE TO PREVENT HOLDING UP SWALE DRAINAGE. NEIGHBOR AT 3 SAYS THE NEW HOME BEING CONSTRUCTED IS OBSTRUCTING WATER FROM MOVING IN THE SWALE. NEW HOME WAS ALSO RECENTLY BUILT AT 1. PLS PERFORM SWALE INSPECTION WHILE YOU ARE THERE MH
INSULATION 08/02/2024 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 7/30/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All supply & return boots are missing the perimeter seals. 2). Bathroom exhausts are missing the second connection point at fan/duct connection.
LATH/BRICK/ WATER BARRIER 07/30/2024 APPROVED RSIMS
ALL ROUGH 07/30/2024 APPROVED - AS NOTED RSIMS
Note: 7/30/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). All supply & return boots are missing the perimeter seals. 2). Bathroom exhausts are missing the second connection point at fan/duct connection.
ELECTRIC-TUG 07/15/2024 APPROVED RMARTIN
WALL SHEATHING 07/08/2024 APPROVED LMILLER
Note: *** NOTES ADDED BY LMILLER 7/8/2024 10:38:52 AM *** prior note resolved 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: 1). Need to remove the many shiners and re-nail as required. Nails are required to be fully embedded into studs.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/08/2024 APPROVED - AS NOTED LMILLER
Note: *** NOTES ADDED BY LMILLER 7/8/2024 10:40:42 AM *** Gables not braced as per detail on sheet SD-9 (called out on plans)
ROOF VALLEY & METAL 07/08/2024 APPROVED LMILLER
WALL SHEATHING 07/03/2024 Disapproved - NO FEE RSIMS
Note: 7/3/24: 1). Need to remove the many shiners and re-nail as required. Nails are required to be fully embedded into studs.
FOUND SURVEY APPROVED (OFFICE) 07/02/2024 APPROVED TBAKER
MONOLITHIC SLAB 06/17/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 06/13/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/11/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/20/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 06/24/2024 07/02/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/24/2024 06/24/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 06/11/2024 06/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/06/2024 06/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 04/15/2024 04/15/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/10/2024 04/10/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Flood panel number missing on site plan/survey
MECH COMPLETE 04/10/2024 04/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 04/10/2024 04/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/10/2024 04/10/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/10/2024 04/10/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/10/2024 04/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN HOLD 04/01/2024 04/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. If report determines unsuitable sub-surface conditions or unsuitable soil conditions, then engineer shall provide a soils mitigation plan in order to ensure soils are suitable to receive the building's foundation. Report to include fill and compaction specifications and engineering inspection requirements. At conclusion of any soils mitigation work, engineer will be required to certify work was performed according to plans.
BLD COMPLETE 04/01/2024 04/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 04/01/2024 04/04/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/01/2024 04/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/01/2024 04/05/2024
LOCATE COMPLETE 04/01/2024 04/04/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/01/2024 04/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor
SW1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/01/2024 04/02/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Flood panel number missing on site plan/survey Please show front setback from left side of garage to front property line
SWALE COMPLETE 04/01/2024 06/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 09/24/2024
SW ENG REINSPECTION 30 ¤30.00 09/24/2024
SW ENG - REVIEW 20 ¤20.00 04/16/2024
SW ENG RES REVIEW 200 ¤200.00 04/16/2024
SEWER CREDIT (¤1,147.00) 04/16/2024
SEWER INSPECTION ¤25.00 04/16/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/16/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/16/2024
SITE PLAN 30 ¤30.00 04/16/2024
WATER-METER ¤514.49 04/16/2024
WATER- TURN ON ¤25.00 04/16/2024
WATER- TURN ON ¤25.00 04/16/2024
ADJUSTMENT 50% (¤493.32) 04/16/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/16/2024
INSPECTION - RESIDENTIAL ¤745.25 04/16/2024
PLAN REVIEW - RESIDENTIAL ¤211.38 04/16/2024
CONNECTION FEES ¤1,187.26 04/16/2024
FC IMPACT FEE EMS ¤62.00 04/16/2024
IMPACT FEE FIRE ¤428.09 04/16/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/16/2024
FC IMPACT FEE LIBRARY ¤268.00 04/16/2024
IMPACT FEE PARKS ¤1,800.99 04/16/2024
IMPACT FEE SCHOOL ¤5,450.00 04/16/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/16/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/16/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/16/2024
SURCHARGE FS 533.721 ¤4.93 04/16/2024
SURCHARGE - FS 468.631 ¤7.40 04/16/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/16/2024
SW ENG INSPECTION 80 ¤80.00 04/16/2024
SW ENG PRE APRON ¤30.00 04/16/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,140.01