I want to search for...

Permit #2024040053

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00490-0020
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 30 sqft
CONDITIONED SPACE: 1211 sqft
Total Square Footage: 1661 sqft
Block: 00490
Subdivision: 7030 -
Job Phone: 844-885-8913
Location Address: 66 RAE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/17/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0020
Contracted Stated Job Value: ¤197,705.46
Job Description: New Single Family Residence
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/23/2024 APPROVED CVANSTRAHLEN
U-CROSS CONNECTION 10/23/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 10/23/2024 11:04:04 AM *** HAS IRR METER with PVB -NO cross connection
ROW - FINAL APRON (AFTER POUR) 10/23/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 10/23/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 10/23/2024 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/22/2024 APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9270 09/26/24 TPOLACEK*** SPOKE WITH PHIL AND EXPLAINED THEY NEED RAISE THE ROADSIDE FORM BOARD TO ACHIEVE LESS THAN 8% SLOPE ON DRIVEWAY APRON. ALSO NEEDS TO GET 5" OVER RIGHT SIDE MITER EDGE OF DRIVEWAY APPROVINF AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. Inspector Notes from Inspection 9270 09/26/24 TPOLACEK*** SPOKE WITH PHIL AND EXPLAINED THEY NEED RAISE THE ROADSIDE FORM BOARD TO ACHIEVE LESS THAN 8% SLOPE ON DRIVEWAY APRON. ALSO NEEDS TO GET 5" OVER RIGHT SIDE MITER EDGE OF DRIVEWAY APPROVINF AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/22/2024 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ELECTRIC - EARLY POWER 09/27/2024 APPROVED CVANSTRAHLEN
Note: 9/27/24 Approved (CV) 8-6-24 1. Emailed FPL at 1:41.
ROW- PRE-APRON (PRE-POUR) 09/26/2024 APPROVED - AS NOTED TPOLACEK
Note: 09/26/24 TPOLACEK*** SPOKE WITH PHIL AND EXPLAINED THEY NEED RAISE THE ROADSIDE FORM BOARD TO ACHIEVE LESS THAN 8% SLOPE ON DRIVEWAY APRON. ALSO NEEDS TO GET 5" OVER RIGHT SIDE MITER EDGE OF DRIVEWAY APPROVINF AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
GRAVITY SEWER TEST 09/04/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/04/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 08/23/2024 APPROVED CBOWERMASTER
INSULATION 08/22/2024 APPROVED AGAETANO
LATH/BRICK/ WATER BARRIER 08/20/2024 APPROVED AGAETANO
ALL ROUGH 08/20/2024 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/06/2024 APPROVED BTAYLOR
ELECTRIC-TUG 08/06/2024 APPROVED - AS NOTED BTAYLOR
Note: 8-6-24 1. Emailed FPL at 1:41.
ROOF VALLEY & METAL 08/02/2024 APPROVED AGAETANO
WALL SHEATHING 08/02/2024 APPROVED AGAETANO
WALL SHEATHING 07/30/2024 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 07/23/2024 APPROVED TBAKER
MONOLITHIC SLAB 07/19/2024 APPROVED AGAETANO
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES 07-18-2024 1. Multiple areas need to be tamped. Check all. 2. Soil has fallen into the footing. Front garage area.
MONOLITHIC SLAB 07/18/2024 Disapproved - NO FEE AGAETANO
Note: 07-18-2024 1. Multiple areas need to be tamped. Check all. 2. Soil has fallen into the footing. Front garage area.
PLUMBING 1ST ROUGH UNDERGROUND 07/16/2024 APPROVED MGIBSON
Note: 7/15/2024 - PREVIOUS INSPECTION NOTES HEAD TEST NOT HOLDING 5', WATER METER IS INSTALLED BUT CHECK GUAGE FOR PRESSURE
PLUMBING 1ST ROUGH UNDERGROUND 07/15/2024 Disapproved -FEE REQUIRED MGIBSON
Note: HEAD TEST NOT HOLDING 5', WATER METER IS INSTALLED BUT CHECK GUAGE FOR PRESSURE
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/11/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/03/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 07/23/2024 07/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/23/2024 07/23/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 07/03/2024 07/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN COMPLETE 04/08/2024 04/12/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 04/08/2024 04/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/08/2024 04/12/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN HOLD 04/01/2024 04/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Geotechnical Report Not Accepted. Provide amended geotechnical report to include the information below. • Specifications for the preparation of the site prior to placement of compacted fill material. • Specifications for material to be used as compacted fill. • Test methods to be used to determine the maximum dry density and optimum moisture content of the material used as compacted fill. • The maximum allowable thickness of each lift of compacted fill material. • Field test method for determining the in-place dry density of the compacted fill. • Minimum acceptable in-place dry density expressed as a percentage of the maximum dry density determine in accordance with the third bullet above. • Number and frequency of field tests required to determine compliance with the sixth bullet above.
BLD COMPLETE 04/01/2024 04/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 04/01/2024 04/04/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/01/2024 04/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/01/2024 04/05/2024
LOCATE COMPLETE 04/01/2024 04/08/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/01/2024 04/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor
SW1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/01/2024 04/02/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 04/01/2024 06/25/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 10/23/2024
CONNECTION FEES ¤1,187.26 04/17/2024
FC IMPACT FEE EMS ¤62.00 04/17/2024
IMPACT FEE FIRE ¤428.09 04/17/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/17/2024
FC IMPACT FEE LIBRARY ¤268.00 04/17/2024
IMPACT FEE PARKS ¤1,800.99 04/17/2024
IMPACT FEE SCHOOL ¤5,450.00 04/17/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/17/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/17/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/17/2024
SURCHARGE FS 533.721 ¤4.21 04/17/2024
SURCHARGE - FS 468.631 ¤6.32 04/17/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/17/2024
SW ENG INSPECTION 80 ¤80.00 04/17/2024
SW ENG PRE APRON ¤30.00 04/17/2024
SW ENG - REVIEW 20 ¤20.00 04/17/2024
SW ENG RES REVIEW 200 ¤200.00 04/17/2024
SEWER CREDIT (¤1,147.00) 04/17/2024
SEWER INSPECTION ¤25.00 04/17/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/17/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/17/2024
SITE PLAN 30 ¤30.00 04/17/2024
WATER-METER ¤514.49 04/17/2024
WATER- TURN ON ¤25.00 04/17/2024
WATER- TURN ON ¤25.00 04/17/2024
ADJUSTMENT 50% (¤420.95) 04/17/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/17/2024
INSPECTION - RESIDENTIAL ¤632.50 04/17/2024
PLAN REVIEW - RESIDENTIAL ¤179.40 04/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,055.85